WARNING (To reduce the risk of fire, electric shock, or personal injury):
-
We suggest installation by a licensed electrician.
-
Please read the instruction carefully and save it as you may need it at a later time.
-
Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
Place the wall switch in the “OFF” position. -
Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
-
Make sure that the ceiling or wall can stand the weight of the lamp before installation.
-
Make sure the voltage you are using is 120V. The maximum wattage is Type B, Max 40W per bulb.
-
Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
-
When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
-
The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:
ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture canbe ordered from the place of purchase. Be sure to useexact wording from illustration when ordering parts.
CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner
(such as mild and non-abrasive soap). Do not use abrasive materials such as
scouring pads or powders, steel wool or abrasive paper.
TOOLS REQUIRED(NOT INCLUDED):
Before starting assembly and installation please prepare the needed tools
as below picture
PARTS TYPE & QTY INCLUDED:
(D) Mounting plate (1)
(E) Green ground screw (1)
(G) Canopy (1)
(H) Lock nut (4)
(I) Strain relief (1)
(J) Ball knob (2)
(K) Cable (1)
(L) Steel wire (4)
(M) Crystal screw (90)
(N) Frame (1)
(O) Crystal (45)
(P) Crystal nut (90)
(Q) Gasket (180)
(R) Quick link (1)
(S) Insurance wire (1)
(T) Insurance buckle (4)
ACCESSORIES & QTY ENCLOSED:
(A) Plastic Wire Connector (3)
(B) Anchor (2)
(C) Anchor screw (2)
(F) Mounting screw (2)
(U) Allen wrench (1)
(M) Crystal screw (8) (spare part)
(O) Crystal (1) (spare part)
(P) Crystal nut (8) (spare part)
(Q) Gasket (5) (spare part)
ASSEMBLY & INSTALLATION INSTRUCTIONS:
-
Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
-
Turn off power
Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position. -
Unscrew ball knobs (J) from mounting plate (D).
-
- Align holes of crystals (O) and holes of frame (N), and then screw crystal screws (M) into holes through gaskets (Q) as shown in the illustration.
• The sequence of installing a crystal screw
(M):gasket (Q), crystal (O), and gasket (Q).
- Align holes of crystals (O) and holes of frame (N), and then screw crystal screws (M) into holes through gaskets (Q) as shown in the illustration.
- Screw crystal nuts (P) to crystal screws (M) to secure crystals (O)
-
- To adjust the hanging height of the fixture:
● Press down and hold lock nuts (H) by hand.
● Pull or push steel wires (L) in and out of canopy (G) to increase or decrease the hanging height.
- To adjust the hanging height of the fixture:
- To adjust the length of cable (K):
● Use Allen wrench (U) to unscrew the screw in one of strain relief (H) as shown in the illustration.
● Carefully pull and push cable (K), then tighten the screw till snug. - After adjusting the height of the fixture, to adjust insurance buckles (T):
● Use a wrench to loosen insurance buckles (T), and then pull insurance buckles (T) to the bottom of canopy by hand.
● Tighten insurance buckles (T) with a wrench to prevent body from sliding off as shown in the illustration.
- Carefully pass the supply wires from the outlet box through mounting plate (D).
● NOTE:To drill the holes in the wall for anchors (B), attach mounting plate (D) to wall with screws ( C & F )
- Attach mounting plate (D) to outlet box and then mark the position of holes in the wall with a pen as shown in the illustration.
- Drill holes and gently knock anchors (B) into the marked holesuntil anchors (B) are level with the wall.
- Secure mounting plate (D) to the wall with screwing anchor screws (C) into
anchors (B) and ,mounting screws (F) into holes of mounting plate (D).
NOTE: the side of mounting plate (D) marked “GND” must face out.
- Make wire connections
Connect wires as shown in the charts below. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect ground wires according to the chart belowConnect wires according to the chart below
Connect Black or Red Supply Wire to:| Connect
White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without tracer| Clear, Brown, Gold or Black with
tracer
Insulated wire(other than green) with copper conductor| Insulated wire(other
than green) with silver conductor
-
Note: When parallel wires (SPT I&SPT ll) are used. The neutral wire issquare shaped or ridged and the other wire will be round in shape or smooth (see illus.)• Twist wires together with plastic wire connector until tightly joined.
• Wrap each connector with approved electrical tape for a more secure connection.
• Carefully tuck all wires into the outlet box.-
- Open quick link (R), and then hang insurance wire (S) to quick link.Close the quick link as shown in the illustration.
-
- Position canopy (G) in place.
- Carefully thread ball knobs (J) through the holes in canopy (G) and
mounting plate (D) and then secure them by tightening ball knobs (J). Note:
canopy (G) should be snug against the ceiling and ball knobs (J). If not,
adjust the threaded length of the preassembled mounting screws on mounting
plate (D):
• first, unscrew the pre-assembled hex nuts;
• then, screw the pre-assembled mounting screws in or out of mounting plate (D);
• when the secure length is achieved, tighten the pre-assembled hex nuts and back to step 8.
- Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the socket.)