Aideepen STC-3028 Temperature Humidity Controller User Manual
- June 9, 2024
- Aideepen
Table of Contents
Aideepen STC-3028 Temperature Humidity Controller
Overview
- With a clear LED display for better readability.
- Temperature and humidity control output
- Very easy to set temperature and humidity
- All parameters set can be saved after a short circuit.
Specifications
- Power Supply: 110V-220VAC
- Temperature controlrange:- 20℃~80℃
- Humidity control range: 1~99%RH
- Control accuracy: 1°C/1%RH
- Sensor: temperature humidity sensor
- Output: Max10A
Wiring Diagram
Key Instruction
- increase the value of the start temperature
- decrease the value of the stop temperature
- increase the value of start humidity
- decrease the value of stop humidity
Key Operation Instruction
Temperature setting:
- In normal working status, the left led displays the real-time temperature. Press the key once. Red led display start temperature. Press the key once. Red led display stop temperature.
- Hold the key for 3s. led flash. Press the or to change the start temperature.
- Hold the key for 3s. led flash, press, or change stop temperature.
Humidity setting:
- In normal working status, the right blue screen displays real-time humidity. Press the key once. The Red led display starts humidity. Press the key once. Blue led display stops humidity.
- Hold the key for 3s. led flash, press, or change the start temperature.
- Hold the key for 3s. led flash, press, or change stop temperature.
Operation Instruction
Cooling mode:
When the set start temperature stops temperature, the controller will work
in cooling mode. You can use the cooler as a load. For example, set the start
temperature to 35 C, and the stop temperature to 32 C. Cooler works when the
temperature is 35 C, and Cooler stops when the temperature is 32 C.
Heating mode:
When set start temperature and stop temperature are, the controller will work
in heating mode. You can use the heater as a load. For example, set the start
temperature to 45 C, and stop the temperature to 60 C. Heater stops when the
temperature 60’Cheater works when the temperature 45C.
Dehumidification mode:
When set start humidity stop humidity, the controller will work in
dehumidification mode. You can use a dehumidifier as a load. For example, set
the start humidity 35%RH, and stop humidity to 156RH. Dehumidifier work when
humidity is 35%RH, Dehumiditifier stops when humidity is 15%RH.
Humidification mode:
When set start humidity stop humidity, the controller will work in
humidification mode. You can use a humidifier as a load. For example, set the
start humidity 45%RH, and stop humidity 60%RH. Humidifier stops when the
humidity 60’C and Humidifier works when the humidity 45C.
Reset:
In normal working status, hold and, the two screens will display 888 to reset
the controller.
Temperature and Humidity Calibration:
- In normal working status, hold and for 2S to enter calibration mode of temperature. Presslorto value between -30-30
- In normal working status, hold and for 2S to enter calibration mode of humidity. The Press or set a value between -30-30
- For example, the tested temperature display 25C, but the real temperature is 30 C, If we set the value 5, the tested temperature will change to display 30 C(25C+5 C). If we set the value to -5, the tested temperature will change to display 20C(25C-5C).
Read User Manual Online (PDF format)