FEATURES

  • Combining AC/DC charger, DC/AC Inverter, AC by-pass & support external MPPT solar charger

  • AC utility charger up to 4520W

  • UPS function (AC by-pass) without interruption, transfer time <10ms

  • True sine wave output (TH 0<3%)

  • High surge power up to 1 0KW

  • Parallel synohronized operation up to 30KW (5+ 1 unit)

  • Temperature controlled cooling fan

  • AC output voltage and frequency selectable by DIP S.W

  • Protections :
    Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage Output : Short circuit / Overload / Over temp.

  • Battery over discharge protection (low voltage disconnect)

  • -30°C ~+70°C wide operating temperature

  • Suitable for lead-acid or Ii-ion batteries

  • Support MODBus-RTU(RS-485) communication

  • Conformal coating

  • 5 years warranty

Accessory List

※Terminal protector mating along with NTN-5K (Standard accessory)

Accessory

Accessory

Accessory

Applications

Applications

  • Home and office appliance
  • Power tools
  • Portable equipment
  • Vehicle
  • Yacht
  • Off-grid solar power system
  • Wireless network
  • Telecom or data com system

Description

NTN-5K is a 5000W highly reliable off-grid true sine wave DC-AC power inverter wi th built-in AC charger and UPS function(AC by-pass). Its key features include: di gi tal design wi th MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality ° fan wi th low acoustic noise, 1 0KW peak power, adjustable AC output voltage and frequency, -30~+ 70 C wide operating temperature range, comple te protection features, and etc. Combined wi th batteries, the NTN-5K is suitable for use in residential, commercial, marine, automobile, mine, construction si te, and remo te areas wi th no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC /laptop, ligh ting, inducti on stove, air condi tioner, electromechanical tool, communication equipment, power distributi on cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.

Model Encoding

Encoding

SPECIFICATION

SPECIFICATION

SPECIFICATION

MODEL NO. NTN-5K-224 NTN-5K-248 NTN-5K-2380
AC OUTPUT RATED POWER(Continuous) 5000W
OVER RATED POWER(3 Min.) 5750W
PEAK POWER(10 Sec.) 7000W 7500W
SURGE POWER(30 Cycles) 8000W 10000W
AC VOLTAGE Default setting set at 230VAC

200 / 220 / 230 / 240Vac  selectable by DIP S.W
FREQUENCY| Default setting set at 50±0.1Hz
50/60Hz selectable by DIP S.W
WAVEFORM                        Note.1| True sine wave (THD<3%)
AC REGULATION| ±3.0% at rated input voltage
DC INPUT| DC VOLTAGE| 24Vdc| 48Vdc| 380Vdc
VOLTAGE RANGE (Typ.)| 20 ~ 33Vdc| 40 ~ 66Vdc| 280 ~ 430Vdc
DC CURRENT (Typ.)| 240A| 120A| 16A
NO LOAD DISSPATION
(Typ.)| NON-SAVING MODE| 2.5A| 1.4A| 0.2A
SAVING MODE| Default disable, auto detect AC output load≦10W will be changed to saving mode
<25W
OFF MODE CURRENT DRAW| ≦1mA
EFFICIENCY (Typ.)          Note.1| 91%| 93%| 94.5%
BATTERY TYPES| Lead Acid or li-ion
PROTECTION| DC  INPUT| LOW| ALARM| 22±0.5Vdc| 44±1Vdc| 300±5Vdc
SHUTDOWN| 20±0.5Vdc| 40±1Vdc| 280±5Vdc
RESTART| 25±0.5Vdc| 50±1Vdc| 335±5Vdc
HIGH| ALARM| 31±0.5Vdc| 62±1Vdc| 420±5Vdc
SHUTDOWN| 33±0.5Vdc| 66±1Vdc| 430±5Vdc
RESTART| 30±0.5Vdc| 60±1Vdc| 400±5Vdc
BAT. POLARITY| No indication. after power on
AC  OUTPUT| OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
OUTPUT SHORT| Shut down o/p voltage, re-power on to recover
OVER LOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 140% load for 10 sec.| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER| 35A
FUNCTION| REMOTE CONTROL| Power ON-OFF remote control by front panel dry contact connector(by RELAY), Open : Remote off ; Short : Normal work
COMMUNICATION| MODBus-RTU (RS-485)
AC UPS MODE| AC INPUT RANGE| 200/220/230/240Vac±16%, recover±13%
FREQUENCY  RANGE| 45 ~ 65Hz
TRASFER TIME(Typ.)| 10ms inverter             AC by pass
AC CHARGER| BOOST CHARGE VOLTAGE| Default 28.8Vdc| Default 57.6Vdc| Default 400Vdc
FLOAT CHARGE VOLTAGE| Default 27.6Vdc| Default 55.2Vdc| Default 385Vdc
CHARGE VOLTAGE RANGE| 21 ~ 30Vdc| 42 ~ 60Vdc| 300 ~ 400Vdc
CONSTANT CURRENT| 135A| 70A| 11.3A
MAX. CHARGE POWER| 4050W| 4200W| 4520W
TEMPERATURE COMPENSATION| By external NTC
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY
& EMC
(Note.4)| SAFETY STANDARDS| CB IEC62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| DC I/P – AC:3.0KVAC           AC – FG:1.5KVAC
ISOLATION RESISTANCE| DC I/P – AC  O/P,  DC I/P – FG,  AC O/P – FG: 100M ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Radiated| BS EN/EN55032(CISPR32)| Class A
Conducted| BS EN/EN55032(CISPR32)| Class A
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55024, BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 1
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

95% interruptions 250 periods
OTHERS| MTBF| 200.9K hrs min.       Telcordia TR/SR-332 (Bellcore) ; 17.8K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 46021183.5mm (LWH)
PACKING| 10.5Kg; 1pcs/ 10.5Kg/ 1.25CUFT
NOTE| 1.Efficiency, AC regulation and THD are tested by 75% load, linear load at 25Vdc/50Vdc/400Vdc input voltage.
2.All parameters not specified above are measured at 25Vdc/50Vdc/400Vdc input and 25℃ of ambient temperature and set to factory setting.
3.The tolerance of each voltage value by models is: 224→±1V; 248→±2V; 2380→±5V.
4.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
)

MODEL NO. NTN-5K-124 NTN-5K-148
AC OUTPUT RATED POWER(Continuous) 4000W
OVER RATED POWER(3 Min.) 4600W
PEAK POWER(10 Sec.) 6000W
SURGE POWER(30 Cycles) 8000W
AC VOLTAGE Default setting set at 110VAC

100 / 110 / 115 / 120Vac  selectable by DIP S.W
FREQUENCY| Default setting set at 60±0.1Hz
50/60Hz selectable by DIP S.W
WAVEFORM                        Note.1| True sine wave (THD<3%)
AC REGULATION| ±3.0% at rated input voltage
DC INPUT| DC VOLTAGE| 24Vdc| 48Vdc
VOLTAGE RANGE (Typ.)| 20 ~ 33Vdc| 40 ~ 66Vdc
DC CURRENT (Typ.)| 200A| 100A
NO LOAD DISSPATION
(Typ.)| NON-SAVING MODE| 2.5A| 1.4A
SAVING MODE| Default disable, auto detect AC output load≦10W will be changed to saving mode
<25W
OFF MODE CURRENT DRAW| ≦1mA
EFFICIENCY (Typ.)          Note.1| 89%| 91%
BATTERY TYPES| Lead Acid or li-ion
PROTECTION| DC  INPUT| LOW| ALARM| 22±0.5Vdc| 44±1Vdc
SHUTDOWN| 20±0.5Vdc| 40±1Vdc
RESTART| 25±0.5Vdc| 50±1Vdc
HIGH| ALARM| 31±0.5Vdc| 62±1Vdc
SHUTDOWN| 33±0.5Vdc| 66±1Vdc
RESTART| 30±0.5Vdc| 60±1Vdc
BAT. POLARITY| No indication. after power on
AC  OUTPUT| OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
OUTPUT SHORT| Shut down o/p voltage, re-power on to recover
OVER LOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER| 50A
FUNCTION| REMOTE CONTROL| Power ON-OFF remote control by front panel dry contact connector(by RELAY), Open : Remote off ; Short : Normal work
COMMUNICATION| MODBus-RTU (RS-485)
AC UPS MODE| AC INPUT RANGE| 100/110/115/120Vac±16%, recover±13%
FREQUENCY  RANGE| 45 ~ 65Hz
TRASFER TIME(Typ.)| 10ms inverter             AC by pass
AC CHARGER| BOOST CHARGE VOLTAGE| Default 28.8Vdc| Default 57.6Vdc
FLOAT CHARGE VOLTAGE| Default 27.6Vdc| Default 55.2Vdc
CHARGE VOLTAGE RANGE| 21 ~ 30Vdc| 42 ~ 60Vdc
CONSTANT CURRENT| 120A| 60A
MAX. CHARGE POWER| 4050W| 4200W
TEMPERATURE COMPENSATION| By external NTC
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY
& EMC
(Note.4)| SAFETY STANDARDS| CB IEC62368-1, TUV BS EN/EN62368-1 approved
WITHSTAND VOLTAGE| DC I/P – AC  I/P:3.0KVAC      DC I/P – AC  O/P:3.0KVAC AC O/P – FG:1.5KVAC
ISOLATION RESISTANCE| DC I/P – AC  O/P,  DC I/P – FG,  AC O/P – FG: 100M ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Radiated| FCC| Class A
Conducted| FCC| Class A
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55024, BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 1
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

95% interruptions 250 periods
OTHERS| MTBF| 200.9K hrs min.       Telcordia TR/SR-332 (Bellcore) ; 17.8K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 46021183.5mm (LWH)
PACKING| 10.5Kg; 1pcs/ 10.5Kg/ 1.25CUFT
NOTE| 1.Efficiency, AC regulation and THD are tested by 75% load, linear load at 25Vdc/50Vdc input voltage.
2.All parameters not specified above are measured at 25Vdc/50Vdc/400Vdc input and 25℃ of ambient temperature and set to factory setting.
3.The tolerance of each voltage value by models is: 124→±1V; 148→±2V.
4.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
)

DERATING CURVE

CURVE

CHARGING CURVE

Default 3 stage charging curve 3 Stage
Embedded 3 stage charging curves
MODEL Vboost Vfloat C.C Adjustable by MODBus
24Vdc Default 28.8Vdc 27.6Vdc 135A max. 21~30Vdc
48Vdc Default 57.6Vdc 55.2Vdc 70A max. 42~60Vdc
380Vdc Default 400Vdc 385Vdc 11.3A max. 300~400Vdc
Suitable for lead-acid batteries (flooded, Gel and AGM) or li-ion

BLOCK DIAGRAM

DIAGRAM

Function Manual

1. Support RS-485 Communication

Communication

※Please refer to for more detail: http://www.meanwell.com/manual.html

2. Remote ON-OFF Control

PAR1/PAR2 Remote ON-OFF AC Output Status
Pin1:3 Short Power inverter ON
Pin1:3 Open Power inverter OFF

3. AC Output Voltage、Frequency、Power saving mode selectable by DIP SW

AC Output

AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW

S1| S2| | S3| S4
OFF| OFF :| 100Vac  or  200Vac| ON  : 50Hz| ON  : Saving mode
OFF| ON   :| 110Vac  or  220Vac
ON| OFF :| 115Vac  or  230Vac| OFF: 60Hz| OFF: Non-Saving mode
ON| ON   :| 120Vac  or  240Vac

4. 3Ø 4W AC output Voltage connection selectable by DIP SW

DIP SW

3Ø 4-wire / Y

◎3Ø 4-wire / Y

5. Temperature compensation(3 stage only)

Temperature compensation function to prolong battery life for lead-acid batteries. Temperature compensation range is 0 ~ 40℃.
The battery temperature sensor comes along with the charger can be connected to the unit to allow temperature compensation of the charging voltage.

If the sensor is not used, the charger works normally.

Temperature

6. AC Output Parallel Function

NTN-5K has the built-in active current sharing function and can be connected in parallel, up to 6 units, to provide higher AC output power as exhibited below :

※The inverter should be paralleled using short and large diameter wiring and then connected to the load.
※The total output current must not exceed the value determined by the following equation:

Maximum output current at parallel operation = (Rated current per unit) x (Number of unit) x 95%;when parallel unit less than 6.

※PAR1/PAR2, PRL Function pin connection

PAR1/PAR2,

PAR1/PAR2,

LED STATUS

LED STATUS

MECHANICAL SPECIFICATION

MECHANICAL

TYPICAL APPLICATION

1. Battery Bank
2. Off-Grid DC/AC Inverter (NTN series)
3. AC Outlet

Shore\)

1. Utility Input
2. Battery Bank
3. Off-Grid DC/AC Inverter (NTN series)
4. AC Outlet

Utility Inlet

1. Utility Inlet
2. Battery Bank
3. Off-Grid DC/AC Inverter
4. AC
5. MPPT Charger (External)
6. Solar Panel (External)

SYSTEM CONFIGURATION

SYSTEM CONFIGURATION

1. Battery Bank
2. Off-Grid DC/AC Solar Inverter (NTN series)
3. AC Outlet

Specifications

  • Model: NTN-5K series
  • Power Output: 5KW True Sine Wave
  • Charger Type: AC Charger / UPS
  • Compliance: IEC62368-1, BS EN/EN62368-1, TPTC004, AS/NZS 62368.1
  • Features: Combining AC/DC charger, DC/AC Inverter, AC by-pass, UPS function, supports external MPPT solar charger

Frequently Asked Questions (FAQ)

Q: Can the inverter be used with solar panels?

A: Yes, the inverter supports external MPPT solar charger for added flexibility and renewable energy usage.

Q: What is the maximum power output of the AC utility charger?

A: The AC utility charger can provide up to 4520W of power output.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals