Roeder BE04603005 Frites Warmhoud Unit Instruction Manual
- June 1, 2024
- Roeder
Table of Contents
Roeder BE04603005 Frites Warmhoud Unit
Specifications
- Model: ECC 46
- Dimensions:
- External: 400x600x270/420mm
- Tank: 400x600x270/420 mm
- Power Consumption: 1 kW
- Net Weight: 24kg
FAQ
Q: Can I use the appliance without professional training?
A: The appliance should only be used by trained personnel as indicated in the instructions.
Q: What should I do if there is a need for repairs?
A: Repairs should only be carried out by an authorized technical service center recommended by the manufacturer.
GENERAL NOTICES
- Read the instructions contained in this manual carefully as they provide important information on safe installation, operation and maintenance procedures.
- Store this manual carefully for future reference by the operators.
- After removing the packing, check the integrity of the unit and, if in doubt, do not operate the unit, call professionally qualified personnel.
- Before connecting the unit, make sure that the data on the plate correspond to those of the electric mains.
- The unit must only be used by a specifically trained person.
- For any repairs, call solely a technical service centre authorized by the manufacturer and ask for genuine parts.
- Failure to comply with the above may jeopardize the safety of the unit.
- Never wash the unit with direct or high-pressure jets of water.
- Do not obstruct air vents or heat dissipation openings.
- All units are supplied with a cable 2 m long having the characteristics stated in Tab. 3.
- In the event of the user or the installation technician failing to observe the instructions given in this manual, the Firm disclaims all responsibility thereof and cannot be held liable for any accidents or trouble caused by such nonobservance.
In the event of the user or the installation technician failing to observe the
instructions given in this manual, the Firm disclaims all responsibility
thereof and cannot be held liable for any accidents or trouble caused by such
non-observance.
THE MANUFACTURER DISCLAIMS ALL RESPONSIBILITY FOR ANY INACCURACIES IN THIS
BOOKLET THAT MAY BE DUE TO TYPING OR PRINTING MISTAKES. THE MANUFACTURER,
MOREOVER, RESERVES THE RIGHT TO MAKE THE MODIFICATIONS TO THE PRODUCT IT
CONSIDERS USEFUL OR NECESSARY, WITHOUT AFFECTING ITS BASIC FEATURES.
TECHNICAL DATA
MINIMA SERIES POTATO HEATER HOT CONTAINER
MODEL| DIMENSIONS in mm| INPUT POWER
kW
| NET WEIGHT
kg
---|---|---|---
outside
LxDxH/H max
| tank
LxDxH
ECC 46| 400x600x270/420| 400x600x270/420| 1| 24
- SUPPLY VOLAGE: 1N 230 V 50/60 Hz
- N.B.: the input power with 1N 220 V 50/60 Hz is approximately 9% lower than the figures given the input power with 1N 240 V 50/60 Hz p circa del 9% higher than the figures given
INSTALLATION INSTRUCTIONS
Installation must be performed by qualified persons in accordance with current
regulations.
WARNINGS
- If the unit is installed against a wall, the wall needs to withstand temperatures of 100°C and must be fireproof; if not, it is essential to install thermal insulation.
- Before proceeding with the installation, remove the protective plastic film and eliminate any adhesive residues by means of a suitable product for cleaning stainless steel.
- Install the unit horizontally, correct positioning is obtained by turning the levelling feet.
- The various units may be installed separately or combined with other units in the MINIMA range.
- This unit is not suitable for encasing.
MINIMA SERIES POTATO HEATER HOT CONTAINER DATA PLATE
The technical data plate is on the back of the unit.
LAWS, REGULATIONS AND TECHNICAL DIRECTIVES
The following regulations must be observed during installation:
- Current accident and fire regulations.
- The regulations of the electricity supply company.
- Health regulations.
- Electrical systems standards.
ELECTRICAL CONNECTION
- The electrical connection must be made in compliance with CEI standards, only by authorized and skilled personnel.
- Firstly, check the data given in the technical data table of this manual, on the data plate and in the wiring diagram. The envisaged connection is of the fixed type.
- IMPORTANT: A multi-polar mains cut-off device must be provided upstream from each unit, with a contact gap of at least 3 mm., for example:
- a manual switch of suitable capacity, equipped with fuses
- circuit breaker with relevant miniature circuit breakers.
EARTHING
It is vital to earth the unit. Connect the terminals marked by the symbols ( )
positioned on the line-in terminal block to an efficient grounding complying
with the regulations in force.
The manufacturer cannot be considered responsible for any damage caused by
failure to earth the system.
CAUTION: NEVER CUT THE GROUNDING CABLE (yellow-green)
EQUIPOTENTIAL SYSTEM
The unit must be included in an equipotential system whose efficiency must be
checked according to the standards in force.
The screw marked with the ”Equipotential” label is on the back.
POWER CABLE
- The unit is delivered fitted for the following power: 1N AC 220…240 V 50/60 Hz.
- The specifications of the power supply connection flexible cable must match or be superior to those of the cable with rubber insulation H07RN-F. Introduce the cable through the cable clamp and secure it firmly. During operation, the power supply voltage should not differ from the voltage rating by +/-10%.
- The unit is supplied with a cable with the specifications given in Tab. 3 (page 7); to access the terminal block or replace it, it is necessary to:
- remove the front panel
- connect the supply cable to the terminal block according to need, following the instructions given on the label located near the terminal block and in this handbook.
CONNECTIONS TO VARIOUS MAIN POWER SUPPLIES
POWER SUPPLY CABLE
USER INSTRUCTIONS
USING THE POTATO HEATER HOT CONTAINER
To switch on the potato heater, turn the knob (Fig. 1) from “0” to “1”: the
green indicator light will automatically come on to show it is working. To
switch it off, just turn the knob back onto “0”.
MAINTENANCE AND CLEANING
STAINLESS STEEL PARTS
- Clean the stainless steel parts with warm soapy water, then rinse and dry with a soft cloth.
- You can keep it shining brightly by periodically wiping it over with liquid POLISH (an easily available product).
- You must never clean the stainless steel with steel wool, wire brushes or common steel scrapers since they can deposit ferrous particles that on oxidizing cause points of rust. It is possible to use stainless steel wool applied in the direction of the satin finish.
- If the unit is not to be used for a long time, give all the steel surfaces a good wipeover with a cloth lightly soaked in Vaseline oil in order to apply a protective film. Periodically ventilate the premises.
INSTALLATION DIAGRAM
ECC46
- Electrical connection
- Equipotential
- O) = Resistenza elettrica a raggi infrarossi
- Infrared electric heating element
- Q) = Manopola comando resistenza
- Heating element control knob
- Z ) = Fondo forato
- Perforated base
ELECTRICAL DIAGRAM
USER INFORMATION
- Under the 2002/95/CE, 2002/96/CE and 2003/108/CE Directives concerning the reduction in the utilisation of dangerous substances in electric and electronic equipment, as well as waste disposal.
- The symbol of the crossed rubbish skip on the equipment or on the package indicates that the product must be separated from other waste at the end of its useful life.
- The differentiated collection of this equipment is organised and managed by the producer. The user who intends to get rid of this equipment shall contact the producer and follow the system that the latter has used in order to collect the equipment separately at the end of its life.
- The proper differentiated collection to start the following recycling, treatment and disposal of the disused equipment in compliance with the environment helps to avoid possible negative effects on the environment and on health, and favours the utilisation and/or recycling of the materials forming the equipment.
- The unauthorised disposal of the product by the holder implies applying administrative penalties provided by the regulations in force.