Roeder BE06603C Electric Heated Bain Marie Minima Range Instruction Manual
- June 17, 2024
- Roeder
Table of Contents
Roeder BE06603C Electric Heated Bain Marie Minima Range
GENERAL REMARKS
- Carefully read the instructions contained in the present booklet as they supply important information relating to safe installation, use and maintenance.
- Keep this booklet with care, for any further consultation by the various operators.
- Having removed the packing, make sure the unit is in good order and in case of doubt, do not use the unit, but call on skilled personnel.
- Before connecting the unit, make sure the data appearing on the serial plate correspond to those of the main electric supply.
- The unit must be used only by a person trained for its operation.
- For any repairs, please call exclusively an authorized technical service center, and ask for original spare parts only.
- Non compliance with the above may compromise the unit’s safety.
- Do not wash the unit with direct or high-pressure water jets.
- Do not obstruct openings or draft grids or heat vents.
- All units are supplied with a 200cm long cable having the characteristics shown in Tab. 3.
- The hook-up wire for the power supply connection should not have characteristics below the type with rubber insulation H07RN-F.
This equipment is to be used with dedicated containers, supplied by the manufacturer. Use of noncompliant pans or other containers is not recommended as they might drop on the tank bottom and damage it as well as not obtaining the required effect from the equipment. The amount of usable space between tank bottom and accessory bottom shall be at least 2 centimeter’s. Use of these machinery always requires presence of water in the tank during operation. We cannot be held liable for any event caused by usage of the machine without water in the tank.
In case of non-compliance with the indications contained in the present manual, both on the user’s part and on the installing technician’s part, the Manufacturer declines any responsibility, and any possible accident or fault caused by the above mentioned non-compliances will not be imputable to the Manufacturer.
The Manufacturer declines any responsibility for any imprecisions appearing on the present booklet, ascribable to transcription or printing errors. Furthermore, the Manufacturer reserves the right to make any modifications to the product deemed useful or necessary, without prejudicing its essential characteristics.
TECHNICAL DATA
TABLE I: TECHNICAL DATA OF ELECTRIC HEATED BAIN-MARIES MINIMA SERIES
MODEL| DIMENSIONS IN mm.| *ABSORBED ELECTRIC POWER kw|
NET WEIGHT kg.
---|---|---|---
EXTERNAL W x D x H/H max.| TANK
Ltr.| L x P x A
EBM46| 400 x 600 x 270/420| 2,5| 305 x 425 x 170|
1,53| 22
EBM 66| 600 x 600 x 270/420| 3,5| 510 x 470 x 170|
3,06| 30**
*Feeding Power: 1N 240 V 50/60 HZ
N.B.: the absorbed power with 1N 220 V 50/60 HZ is around 16% lower.
INSTALLATION INSTRUCTIONS
Installation must be performed by qualified technicians according to the law in force.
WARNINGS:
Should the unit be installed against a wall, the latter must be heat-resistant
to temperatures of 100°C and must be fireproof; otherwise, the application of
a lagging material shall be absolutely necessary.
Before proceeding with the installation, remove the protective plastic film
from the relevant parts, eliminating any adhesive
residues with an appropriate cleaning product suitable for stainless steel.
Install the unit in a horizontal position; its correct levelling will be
achieved by rotating the adjustable feet.
The equipment can be separately installed or joined to other equipment
belonging to the same range.
This equipment is not suitable for embedding.
DATA PLATE FOR ELECTRIC HEATED BAIN-MARIES MINIMA SERIES
The technical data plate is located on the back of the equipment.
LAWS, REGULATIONS AND TECHNICAL DIRECTIVES
The following indications should be observed during installation:
- Accident and fire regulations in force
- The regulations of the electric power supply company.
- Hygienic regulations.
- The rules for electrical systems.
ELECTRICAL CONNECTION
Electrical connection should be performed in compliance with the IEC regulations, only by authorized and competent personnel. In the first instance, examine the data shown on the technical data table of this manual, on the serial plate and on the electrical diagram.
The envisaged connection is of the fixed type.
IMPORTANT: Ahead of each unit it is necessary to install an omni polar main breaker, having a spacing among contacts of at least 3mm; example:
- manual breaker of appropriate capacity, complete with fuse valves
- automatic breaker with respective magnetothermal relays..
EARTHING
It is essential to earth the unit.
To this purpose, it is necessary to connect to an efficient earthing system
the terminals marked with the symbols ( ) placed on the line-receiving
terminal box. The earthing system should comply with the law in force.
The Manufacturer cannot be deemed responsible for any damages caused by the
lack of unit earthing.
ATTENTION: NEVER INTERRUPT THE EARTH WIRE (Yellow-Green).
EQUIPOTENTIAL
The unit should be included within an equipotential system whose efficiency must be tested according to the law in force. The screw marked with the label “Equipotential” is located on the back.
POWER SUPPLY CABLE
The unit is supplied fitted for the following voltages: 1N AC 220…240V 50/60 Hz.
The flexible cable for power supply connection should not have characteristics lower than the rubber insulation type H07RN-F. The cable should be inserted through the cable clamp and firmly fastened. Furthermore, the supply voltage with the unit functioning should not go outside the value of the nominal tension ±10%.
This equipment is provided with a cable having the characteristics specified in Table 3 (page 8); to have access to the terminal board or to replace it, proceed as follows:
- remove the front panel
- connect the cable to the terminal box according to need, and following the instructions shown on the provided label near the terminal board and on the present booklet.
CONNECTIONS TO VARIOUS MAIN POWER SUPPLIES
POWER CORD
MODEL | EBM46 | EBM66 |
---|---|---|
TYPE OF TENSION | Max. A/f | N° cables mm2 |
1N AC 220…240 V 50/60 Hz | 6,4 | 3 x 1,5 |
INSTRUCTIONS FOR THE USER
HOW TO USE THE BAIN-MARIE
Please remember that this equipment has to operate when water has reached the
appropriate level in the tank; it cannot be used without water.
In order to turn the bain-marie equipment on, turn handle (see figure 1) from
position “0” to position “1” and the green led will switch on .
Turn the handle of the thermostat (see Figure 2) and bring it to the required
temperature level; the yellow led will automatically switch on (indication of
the heating).
When reaching the pre-set temperature level, the yellow led will then switch
off.
In order to switch the bain-marie equipment off, just turn the handle “Figure
1” until the “0”reaches the index.
DRAINING THE TANK
To perform this operation you need to insert the supplied relevant extension into the drain tap, with the click-on connection. Place beneath it a tray for collecting the water, then open the tap by pulling the knob to the right.
Warning: It is advisable this operation be performed when the water is not too hot.
MAINTENANCE AND CLEANING
STAINLESS STEEL PARTS
- Clean the stainless steel parts with soapy lukewarm water, then rinse well and dry thoroughly.
- Brilliance is kept using liquid POLISH periodically, (Polish is a product easy to be found).
- Absolutely avoid to clean the stainless steel with common steel-wool, or common steel brushes and scrapers, as they may discard ferrous particles which, on depositing, cause rust spots. You may, if you like, use stainless steel wool passed on following the butter finish direction.
- Should the unit remain unused for long periods, heavily rub all the steel surfaces with a cloth slightly wetted with Vaseline oil, in order to cover them with a protective film. Periodically ventilate the premises.
INSTALLATION DIAGRAM
Equipotential
Supply
cable inlet
ELECTRIC DIAGRAMS
SHORTNAME| N° CODICE
CODE n°
N° CODE
Nr. CODEX
N° CODICO|
---|---|---
CA| | POWER SUPPLY CABLE
M| RTBF 900045| TERMINAL BLOCK
CO1| RTCU 700212| SWITCH
T1| RTBF 800152| THERMOSTAT
R1| RTCU 700280| HEATING ELEMENT
L1| RTCU 900290| GREEN LAMP
L2| RTCU 900072| ORANGE LAMP
SHORTNAME| N° CODICE
CODE n°
N° CODE
Nr. CODEX
N° CODICO|
---|---|---
CA| | POWER SUPPLY CABLE
M| RTBF 900045| TERMINAL BLOCK
CO1| RTCU 700212| SWITCH
T1| RTBF 800152| THERMOSTAT
R1| RTCU 700280| HEATING ELEMENT
L1| RTCU 900290| GREEN LAMP
L2| RTCU 900072| ORANGE LAMP
USER INFORMATION
Pursuant to the 2002/95/CE, 2002/96/CE and 2003/108/CE Directives concerning
the reduction in the utilization of dangerous substances in electric and
electronic equipment, as well as waste disposal.
The symbol of the crossed rubbish skip on the equipment or on the package
indicates that the product must be separated from other waste at the end of
its useful life.
The differentiated collection of this equipment is organized and managed by
the producer. The user who intends to get rid of this equipment shall contact
the producer and follow the system that the latter has used in order to
collect the equipment separately at the end of its life.
The proper differentiated collection in order to start the following
recycling, treatment and disposal of the disused equipment in compliance with
the environment helps to avoid possible negative effects on the environment
and on health, and favor’s the reutilization and/or recycling of the materials
forming the equipment.
The unauthorized disposal of the product by the holder implies applying
administrative penalties provided by the regulations in force.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>