iProven OXI-27 Finger Pulse Oximeter Instruction Manual

June 1, 2024
iProven

iProven OXI-27 Finger Pulse Oximeter

What’s in the box?

  • Oximeter iProven OXI-27
  • Two AAA-batteries
  • Lanyard
  • Oximeter case

iProven-OXI-27-Finger-Pulse-Oximeter-fig- \(1\)

Intended use

  • The iProven Fingertip Pulse Oximeter is a digital monitor that measures the level of oxygen saturation of hemoglobin in the arterial blood. The monitor detects signs of low levels of oxygen in the body.
  • It measures the pulse rate in beats per minute and also displays a bar graph that illustrates the strength of the pulse signal.
  • The OXI-27 is intended for use on children above four years old and adults whose weight is between 15kg and 110kg.
  • The device should be used in the home/domestic setting only and is not intended for continuous monitoring.
  • This device is intended for non-invasive measuring and monitoring of the oxygen saturation of hemoglobin in arterial blood and the pulse rate in beats per minute.

How to increase oxygen saturation in a natural way?

  1. Try to breathe more slowly and more deeply. In through the nose, out through the mouth. Guess you heard that before. But being aware of your respiration can already improve its quality!
  2. Add green to your world! Consider buying some (extra) plants. Open your window more often. Take a walk in the park. Being in the green can improve your oxygen levels. It will also help you to feel more relaxed. Which will help you to breathe more deeply, and as said, that can also improve your oxygen levels!
  3. Stay hydrated! The O in H20 stands for the oxygen molecules in water. So drinking water will help to keep your oxygen levels up. Hydrating yourself has quite a few extra benefits. It can help to fight fatigue. It may keep a headache away. And it can even help you to lose weight

How to take a measurement

  1. Open the clip and place your finger inside the oximeter. Make sure your nail touches the upper part of the clip, see the image
  2. Press the button and wait for 10 seconds
  3. Read your saturation level and heart rate from the display

iProven-OXI-27-Finger-Pulse-Oximeter-fig- \(4\)

Components of the device

iProven OXI-27WH Manual ver 1.1 US

Troubleshooting FAQ

How do I clean the device?

  • You can use medical alcohol to disinfect it. Please use a soft cloth to clean the whole unit. Don’t use any abrasive or volatile cleaners.

How can I replace the batteries?

  • Open the battery cover. Insert the batteries according to the polarity indications. Close the battery cover

When do I replace the batteries?

  • A low battery sign shows on the display.
    • The LED display dims.
    • When powering on the monitor, the LED display doesn’t light up.

How do l attach the lanyard?

  • Put the thin end of the rope through the hole. Then put the thick end of the rope through the loop, and pull the end to secure it.

Please note

  • Measurements may be inaccurate in the following situations:
  • When you’re moving your fingers
  • In a very cold environment
  • When your finger isn’t placed properly into the device (see above)
  • Excessive ambient light, such as a fluorescent lamp or direct sunlight, may affect the result
  • Enamel or acrylic fingernail polish or other fingernail applications may give inaccurate readings
  • For sports and aviation use only

oxygen saturation

  • Oxygen saturation indicates how much oxygen the blood is carrying as a percentage of the maximum it can carry.
  • Red blood cells contain the iron-containing protein hemoglobin.
  • Haemoglobin (Hb) attaches oxygen to the red blood cell and carries it through the body.
  • 1 hemoglobin molecule can attach up to 4 oxygen molecules.
  • If all the hemoglobin molecules are carrying 4 oxygen molecules, it is said that you have a saturation of 100%.
  • A healthy person with healthy lungs, breathing air at sea level, will have an oxygen saturation of between 95% and 100%.

Measurement principle

  • The fingertip pulse oximeter contains a microprocessor and a display.
  • The display shows the oxygen saturation, the pulse rate, and the intensity of your heartbeat.
  • The display continuously gives information about the level of oxygen in your body and your pulse rate per minute. The monitor updates its calculations regularly during use to show immediate readings. The monitor starts to beep if the value of the oxygen saturation 94% or lower. It will also beep when your heartbeat is below 50 or above 130.

Extra notes on the device

  • This device is not intended for use on extremities other than the fingertip.
  • Do not confuse self-monitoring with self-diagnosis. Do not begin or end medical treatment without asking a physician for treatment advice.
  • If you are taking medication, consult your physician to determine the most appropriate time to measure the oxygen levels in your body and pulse rate. Never change a prescribed medication without consulting your physician.
  • The user must check that the equipment functions safely and see that it is in proper working order before use.
  • Avoid shaking and collisions.
  • If you have any problems with this device, such as setup, maintenance, or use, please contact customer support. Don’t open or repair the device by yourself.
  • Please report to iProven if any unexpected operations or events occur.
  • Place the device in a dry environment. Avoid sunlight and do not immerse in water. Also, avoid dusty environments and unstable temperatures. All of these factors can impact and reduce the performance and lifetime of the device.
  • Make sure children do not use the device unsupervised.

EMC Guidance

Guidance and manufacturer’s declaration — electromagnetic emission

The iProven OXI-27 is intended for use in the electromagnetic environment specified below. The customer of the user of the iProven OXI-27 should ensure that it is used in such an environment.

Emission test Compliance Electromagnetic environment — guidance

RF emissions CISPR 11: Group 1

  • The OXI-27 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.

RF emission CISPR 11: Class B

  • The OXI-27 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.

Error messages

Problem Possible reason Solution
The SpO2 and Pulse Rate cannot be displayed normally 1) The finger is not

positioned properly 2) The user’s SpO2 is too low to be detected 3) Poor blood circulation in the fingers| 1) Place the finger properly and try again 2) Try again; consult your doctor if you are sure the device works correctly 3) Move your fingers to stimulate blood circulation
The SpO2 and Pulse Rate are not displayed constantly| 1) The finger is not placed inside deep enough 2) The finger is shaking or the user is moving| 1) Place the finger properly and try again 2) Try to calm down and stop moving your finger
The device cannot be turned on| 1) The batteries are low, or there are no batteries in the device 2) The batteries are not inserted properly 3) The device does not work properly| 1) Change batteries 2) Reinstall batteries 3) Contact customer support via www.iproven.com
The display is off suddenly| 1) The device powers off automatically when there is no signal within 16 seconds 2) The batteries are low| 1) This is normal

CAUTION

  1. Remove batteries if the device is not likely to be used for some time.
  2. Worn batteries are harmful to the environment. Do not dispose of daily garbage.
  3. Remove the old batteries from the device following your local recycling guidelines.
  4. Do not dispose of batteries in a fire. Batteries may explode or leak.
  5. The operator should not touch the output of the batteries /adapter and the user simultaneously. To avoid measurement errors, please avoid strong electromagnetic fields, radiated interference signals, or electrical fast transient/ burst signals.

Symbols Description

  • Type BF applied part
  • Attention must be paid
  • %SpO2 The Pulse Oxygen saturation (%)
  • Pulse rate (beats per minute)
  • The battery voltage indication is deficient (change the battery in time to avoid inexact measurements)
  • No finger inserted
    • An indicator of signal inadequacy
  • Waste electrical materials should be sent to a dedicated collection point for recycling anti-dust and anti-water class

Warranty

  • This device is subject to a Limited Warranty. This covers any defects in materials or workmanship under normal use during the Warranty Period. iProven will either replace the product or repair the product at no charge, using new or refurbished replacement parts. The Warranty Period of this proven product is 2 years from the date of purchase. A replacement product or product part assumes the remaining warranty of the original product purchase. This Limited Warranty does not cover batteries and packaging, nor any problem that is caused by conditions, malfunctions, or damage not resulting from defects in material or workmanship.
  • To obtain warranty service, contact our customer support at www.iproven.com to determine the problem and the most appropriate solution for your situation.
  • iProven owns and reserves the rights comprised in the copyright of this document. No part of this document may be changed, copied, reproduced, or imitated in any form or by any means without the prior written consent of iProvèn.
  • All statements, information, and recommendations in this document are provided “AS IS” without warranties, guarantees, or representations of any kind, either express or implied. The information in this document is subject to change without notice. iProven reserves the right to the final interpretation of this document.

Technical Specifications

Display information

  • Display format: LED display
  • The Pulse Oxygen Saturation (SpO2): Digital
  • Pulse Rate (PR): Digital
  • Pulse intensity (bar-graph): Digital bar-graph display

SpO2 Parameter Specification

  • Measuring range: 35%-100% (resolution is 1%)
  • Accuracy:
    • 70%-100%; +/-2%
    • Below 70%; unspecified

Pulse Parameter Specification

  • Measuring range: 25bpm-250bpm (resolution is 1bpm)
  • Accuracy: +/-2bpm

Pulse Intensity

  • Range: Continuous bar-graph display; the higher the bar on the display, the stronger the pulse

Battery requirement

  • 2x 1.5V (AAA size) alkaline battery

Power Consumption

  • Smaller than 35 mA

Battery Life

  • Two batteries can work continuously for 24 hours

Power off

  • The fingertip pulse oximeter can be powered off in case no finger is placed within the device for 16 seconds.

Optical Sensor

  • Red light (wavelength is 660nm)
  • Infrared (wavelength is 905nm)

Dimensions and Weight

  • Dimensions: 62 (L) x 37 (W) x 32 (H) mm
  • Weight: About 50 grams with the batteries

FREQUENTLY ASKED QUESTIONS

What is the brand and model of the finger pulse oximeter described?

The brand is iProvèn and the model is OXI-27.

What are the package dimensions and weight of the iProven OXI-27 Finger Pulse Oximeter?

The iProven OXI-27 Finger Pulse Oximeter has package dimensions of 4.02 x 2.01 x 1.97 inches and weighs 3 ounces.

What type of batteries does the iProven OXI-27 Finger Pulse Oximeter require?

The iProven OXI-27 Finger Pulse Oximeter requires 2 AAA batteries.

What is the battery life of the iProven OXI-27 Finger Pulse Oximeter?

The battery life of the iProven OXI-27 Finger Pulse Oximeter is approximately 2 years.

What is the price of the iProven OXI-27 Finger Pulse Oximeter?

The price of the iProven OXI-27 Finger Pulse Oximeter is $12.96.

What warranty period is offered for the iProven OXI-27 Finger Pulse Oximeter?

The iProven OXI-27 Finger Pulse Oximeter comes with a 2-year warranty.

How does the iProven OXI-27 Finger Pulse Oximeter measure oxygen saturation and pulse rate?

The iProven OXI-27 Finger Pulse Oximeter measures oxygen saturation and pulse rate by emitting light through the fingertip and detecting the amount of oxygen in the blood based on light absorption.

Why is my iProven OXI-27 Finger Pulse Oximeter not turning on?

If your iProven OXI-27 Finger Pulse Oximeter is not turning on, first ensure that the batteries are inserted correctly and have sufficient charge. Try replacing the batteries with fresh ones.

How can I address inaccurate readings on my iProven OXI-27 Finger Pulse Oximeter?

Inaccurate readings on the iProven OXI-27 Finger Pulse Oximeter can sometimes be caused by improper positioning of the device on the fingertip or interference from external factors. Ensure that the device is securely attached to the fingertip and that there are no obstructions.

What should I do if my iProven OXI-27 Finger Pulse Oximeter displays error messages?

Error messages on the iProven OXI-27 Finger Pulse Oximeter may indicate issues such as low battery, improper finger placement, or sensor malfunction. Refer to the user manual to identify the meaning of the error message displayed and follow the troubleshooting steps provided.

How do I troubleshoot if my iProven OXI-27 Finger Pulse Oximeter is not holding its position on the fingertip?

If your iProven OXI-27 Finger Pulse Oximeter is not staying securely on the fingertip, ensure that the device is properly positioned and that the finger is clean and dry. Adjust the position of the oximeter and gently press it onto the fingertip to ensure a snug fit.

What steps should I take if my iProven OXI-27 Finger Pulse Oximeter is not displaying any readings?

If your iProven OXI-27 Finger Pulse Oximeter is not displaying any readings, first check the battery level to ensure it is not depleted. Replace the batteries with fresh ones if necessary. Ensure that the device is properly attached to the fingertip and securely turned on.

How can I troubleshoot if my iProven OXI-27 Finger Pulse Oximeter is displaying inconsistent readings?

Inconsistent readings on the iProven OXI-27 Finger Pulse Oximeter may be caused by movement during measurement or poor blood flow to the fingertip. Ensure that the finger is still and that there is good blood flow. Check for any obstructions or interference around the sensor area.

What should I do if my iProven OXI-27 Finger Pulse Oximeter is emitting unusual sounds or vibrations?

If your iProven OXI-27 Finger Pulse Oximeter is emitting unusual sounds or vibrations, immediately stop using the device and turn it off. Unusual sounds or vibrations may indicate a mechanical or internal issue with the device.

How do I troubleshoot if my iProven OXI-27 Finger Pulse Oximeter is experiencing a slow response time?

A slow response time on the iProven OXI-27 Finger Pulse Oximeter may be due to low battery, poor finger placement, or sensor malfunction. Ensure that the battery is sufficiently charged and that the device is properly attached to the fingertip.