iProvèn DTR-1835-US-2 Digital Oral Thermometer User Manual

October 30, 2023
iProven

iProvèn DTR-1835-US-2 Digital Oral Thermometer

iProvèn_-DTR-1835-US-2-Digital-Oral-Thermometer-
product

Digital Thermometer Model DTR-1835BLU

iProvèn®-DTR-1835-US-2-Digital-Oral-Thermometer-fig-1

Congratulations on your purchase of this product. Please read the instructions carefully before using the thermometer for the first time and keep these instructions In a safe place. This product is intended for the measurement of human body temperature.

Operating Instructions

  1. Please disinfect the probe before use.
  2. Press the button to activate the thermometer.
    • A short beep will sound and the thermometer runs a check showing all the digital segments on the LCD.
    • After the check, the last measurement result is shown for 2 seconds.
    • As soon as – -.- – appears on the LCD the thermometer is ready.
  3. Put the thermometer sensor in the desired measurement position (oral or rectal).
  4. Wait for the beep to sound and the CC or °F icon to stop flashing. The measurement is now completed.
  5. Read the result from the display.

This Is a maximum thermometer and the displayed temperature can slightly increase if you leave the thermometer In the measurement position after the beeps. Please follow the instructions described In the ‘Methods of measuring temperature section.

Fever Alarm

If the detected body temperature exceeds 100.0°F/37.8 <>C the thermometer will sound an alarm:

“bl-bl-bl—bl-bl-bl-“.The alarm indicates a fever may be approaching.

Fever Indication

  • Over 100.00F/37. SoC; elevated temperature – fever may be approaching!
  • 99.1-99.9″F/37.3-37.7<>C; slightly elevated temperature
  • <99.00F/<37.2<>C; normal temperature

Functions

  • Auto-Off Function
    When the measurement is completed, switch the thermometer off by pressing the ON/OFF button. If not switched off, the thermometer will switch off automatically after 10 minutes.

  • Memory Function
    When the thermometer is switched on, the last measurement will be shown for 2 seconds. Press the button again to tum the thermometer off. When the thermometer will remain turned on, the result will be overwritten by the new measurement.

Methods Of Measuring Temperature

It is important to remember that the accuracy of the body temperature reading depends on the measurement position. When keeping track of the results, the measurement position must always be specified in order to ensure that a correct temperature reading Is recorded.

Rectal Measurement
From a medical point of view, this Is the most accurate method because the temperature at this measurement position is closest to the core body temperature. The thermometer tip is inserted carefully Into the rectum for a maximum of 2 cm (1”). The usual measuring time Is approximately 20 seconds.

Oral Measurement
There are different heat zones in the mouth. As a general rule, the oral temperature Is 0.3-0.8°C (0.5-1.4°FJ lower than the rectal temperature. To ensure that the reading is as accurate as possible, place the thermometer tip to the left or right of the root of the tongue. The thermometer tip should remain in constant contact with the tissue under the tongue during the reading. The mouth should remain closed during the reading. The usual measuring time is approximately 20 seconds.

Important! As eating, drinking, and breathing through the mouth influence the temperature of the mouth tissue, we highly recommend not eating, drinking, or breathing through the mouth within 3 minutes before taking an oral measurement.

Axillary Measurement is NOT recommended
It is NOT recommended to use this device for taking axillary (underarm) temperature measurements. This quick-reading thermometer will not accurately measure the axillary temperature.

Switching The Temperature Scale ( 0C Or 0F)
First, make sure the thermometer is switched off. If it is still switched on, press the button once to switch off. When the thermometer is off, press and hold the button for 3 seconds to switch the measuring scale. The new scale 0C or 0F is now saved.

Cleaning And Disinfection

The best way to clean the thermometer tip is by applying a disinfectant (e.g., 70% ethyl alcohol) with a damp cloth. This waterproof thermometer can be immersed in lukewarm water for thorough cleaning and disinfection.

Safety Precautions

  • Do not expose the thermometer to hot water over 50 0C (122 0F).
  • Do not expose the thermometer to high temperatures or direct sunlight.
  • Do not drop the thermometer. It is neither shockproof nor impact-resistant.
  • Do not open the device except the battery compartment.
  • Do not bend the device except for the flexible tip.
  • Avoid bending the tip by more than 45 degrees.
  • Do not clean with thinners, petrol, or benzene. Only clean the thermometer with water or disinfectant.
  • Do not immerse the thermometer under water deeper than 15cm(6″) for longer than 5 minutes.
  • The thermometer contains small parts (including a battery) which can be swallowed by children.
  • For this reason, do not leave the thermometer unattended in the hands of children.
  • If the ambient temperature is over 35 0C (95°F) dip the thermometer tip in cold water for 10 seconds prior to taking a measurement.
  • Persistent fever, in particular in children, has to be treated by a doctor. If this occurs, please get in touch with your doctor!

Battery Replacement

The battery is empty and needs replacing when the battery symbol appears on the right of the LCD.

To replace the battery: Lay the thermometer with the button downwards on a flat surface.

Remove the screw: Pull off the battery cover. Gently slide out the circuit board with the battery chamber, up to 1 cm (0,5″). Replace the battery with one of the same types (preferably non-mercury) with the “+” polarity facing up. After replacing the battery, reposition the circuit board, the battery cover, and the screw.

To protect the environment, please do not dispose of batteries as normal waste. Instead, please hand them in at a collection point or municipal recyclable material center as special waste.

Technical Data

  • Type: maximum thermometer
  • Measurement Range: 32.0~43.00C (89.6~ 109.4°FJ
  • Measurement Accuracy:
    • ±0.1oC at 35.5~42.0oC at ambient temperature 18~28oC
    • ±0.2oC at 32.0~35.5oC at other ambient temperatures.
    • (±0.2°F at 95.9~ 107.6°F at ambient temp. 64.4~82.4°F
    • ±0.4°F at 89.6~95.9°F at other ambient temperatures.)
  • Storage/Transport Conditions:- 20~55oC, 15%~95% RH
  • Ambient Operating Conditions: 5~35 ac, 15%~95%RH
  • Min Scale: 0.1oC/0. 1°F
  • Battery Type: Alkaline manganese battery, type LR41, 1.5V.
  • Weight: Approximately 12g
  • This thermometer is latex free.

Explanation Of LCD Symbols

  • The battery is empty
  • Lo 0C/ Lo °F The temperature is under 32 °C or 89.6 °F
  • Hi 0C/ Hi °F The temperature is over 43 0C or 109.4 °F
  • Explanation of symbols on the label

The battery in this product complies with the requirements stated in the European Directives 2006/66/EEC.

Type BF equipment.

Consumed electronic products must not be mixed with conventional domestic waste. Take this product to an appropriate waste collection point for correct handling and recycling.

Calibration Check

This thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the operation instruction, periodic re- adjustment is not required. However, if there are indications that the product does not maintain the defined error limits or if the calibration could have been affected by an external factor or by any other means a calibration check should be carried out immediately. For calibration, please observe any national statutory or administrative regulations. The calibration check can be carried out by any competent authority or by authorized service providers. Test instructions for a calibration check can be provided to the relevant authorities and authorized service providers on request.

Warranty

This Limited Warranty covers any defects in material or workmanship under normal use during the Warranty Period of 365 days after purchase. iProven will either replace the product or repair the Product at no charge, using new or refurbished replacement parts. A replacement product or product part assumes the remaining warranty of the original product purchase. This Limited Warranty does not cover batteries and packaging. It also does not include any problem that is caused by: conditions, malfunctions, or damage not resulting from defects in material or workmanship.

Customer Support

For obtaining warranty service and for any other inquiries or suggestions please contact iProven customer support at www.iproven.com

Manufactured for: iProven USA LLC 9450 SW Gemini Dr #48879 Beaverton – OR 97008-7105 Call us toll-free if you have any questions or concerns +1 855-700-1668

  • Model: DTR-1835BLU
  • Manual version: 1.1

Frequently Asked Questions

How do I turn on the thermometer?

Press the power button located on the device to turn it on. The thermometer will display the last recorded temperature.

How do I take a temperature reading?

Place the thermometer tip under the tongue, close the mouth, and wait for the beep signal. The display will show the measured temperature.

Can I use this thermometer for other measurement methods?

This thermometer is specifically designed for oral temperature measurement. It is not recommended for other methods such as rectal or axillary measurements.

Is the thermometer waterproof?

No, the thermometer is not waterproof. Do not immerse it in water or any other liquid. Clean it with a soft, dry cloth.

How accurate is the thermometer?

The thermometer is designed to provide accurate temperature readings within a certain range. Refer to the product documentation for information on accuracy and precision.

Can I use this thermometer for infants or young children?

This thermometer is suitable for adults and children aged three years and above. For infants and young children, it is recommended to use a specialized thermometer designed for their age group.

Does the thermometer have a fever indicator?

Yes, the thermometer has a fever indicator that displays a different color or symbol when the measured temperature exceeds a certain threshold, indicating a fever.

How do I change the temperature scale (Celsius/Fahrenheit)?

Refer to the product instructions to learn how to switch between Celsius and Fahrenheit scales. It usually involves pressing a combination of buttons or accessing a setting on the device.

Does the thermometer have a memory function to store previous readings?

Yes, the thermometer typically has a memory function that allows you to recall and view previous temperature readings. Consult the product documentation for instructions on accessing and using the memory function.

How do I replace the battery?

The process of replacing the battery may vary depending on the specific model of the thermometer. Refer to the product instructions for guidance on how to safely replace the battery.

Video – How to Use

Download this PDF Link:iProvèn DTR-1835-US-2 Digital Oral Thermometer User Manual

Read User Manual Online (PDF format)

Loading......