iProven NCT-978 Infrared Forehead Thermometer Instruction Manual

June 1, 2024
iProven

iProven NCT-978 Infrared Forehead Thermometer

iProven-NCT-978-Infrared-Forehead-Thermometer-PRODUCT

Notice

Purchase or possession of this device does not carry any express or implied license to use with replacement parts which would, alone or in combination with this device, fall within the scope of one of the related patents.

Safety Information

  • This device may only be used for the purposes described in these instructions.
  • The manufacturer cannot be held liable for damage caused by incorrect application.
  • The Non-Contact Infrared Body Thermometer is designed to minimize the possibility of hazards from errors in the software program by following Sound and light Engineering Design Processes, Risk Analysis, and Software Validation.

Introduction

  • Thank you for choosing the iProven Non-Contact Body Infrared Thermometer. The NCT-978 can be used to measure your body temperature via the forehead. It can also be used to measure the room or object temperature.
  • Please read the instructions carefully in order to accurately utilize this equipment. Temperature measurements may not be valid or accurate if they are not performed in accordance with the instructions provided in this manual. Please keep these instructions handy for future reference.
  • You can also find the latest digital version of this manual at www.iproven.com.
  • It is our passion to develop high-quality products for home use. Our products are manufactured at the highest technical standards of professional quality, durability, and consistency. They are also designed with elegant simplicity in mind, making them easy to use at home.
  • To help you get the most from our products, we provide clear instructions for each device. The manual also includes helpful information that contributes to your overall health awareness.
  • In order to make sure that our products are tailored to your needs, we welcome your feedback. If you have any issues, questions, or recommendations, please share your thoughts with us at www.iproven.com

iProven – Professional Care Brought Home

Warning

Warnings are identified by the WARNING symbol shown above.

  • The Non-Contact Infrared Body Thermometer is to be operated by consumers in the home setting and primary care setting as a screening tool. This manual, accessories, directions for Use, all precautionary information, and specifications should be read before use.
  • This product is designed to measure human body temperature on the forehead. Do not use it for any other purpose.
  • This product is intended in the home setting and primary care setting as a screening tool.
  • Do not use the thermometer if it malfunctions or has been damaged in any matter.
  • When the ambient temperature of the thermometer changes too much, such as moving the Thermometer from one place of lower temperature to another place of higher temperature, allow the thermometer to remain in a room for 30 minutes where the temperature is between 15 C to 35 C (59 F – 95 F).
  • Remove primary batteries if the equipment is not likely to be used for a long time.
  • This product is not waterproof, do not be immersed in water or other liquid; If cleaning and disinfection, please follow the “Care and Storage” section requirements.
  • Do not touch the sensor of infrared detection with your fingers.
  • If a cold compress on the forehead of fever patients, or other measures to cool down, the temperature data will be low, which should be avoided in this case to measure body temperature.
  • If measuring human forehead temperature, please select “body” mode; for measuring other objects, liquids, food, and other temperature please select “surface” mode.
  • This product must be operated in a stable environment, if the ambient environment is mutations, please note whether there is fog on the sensor, if any, before using accordance with the “Care and Storage” section to remove the fog.
  • Do not near strong electrostatic fields or strong magnetic fields, thus avoiding the impact on the accuracy of the measurement data.
  • Do not mix the old and new batteries to avoid damage to the product.
  • It may affect the accuracy of measurements when the forehead is covered by hair; perspiration, cap, or scarf.
  • The measuring result of this product is only for your reference. If you have any doubts, please measure the temperature in other methods.
  • The device should be kept out of the reach of children/pets. When not in use, store the device in a dry room and protect it against extreme moisture, heat, lint, dust, and direct sunlight. Never place any heavy objects on the storage case.
  • Do not throw batteries into the fire.
  • Only use recommended batteries. Do not use rechargeable batteries.
  • This thermometer irreplaceable diagnostic in hospitals.
  • Do not fall, disassemble, or modify the device.
  • Do not use this device if you think it is damaged or notice anything unusual.
  • This device comprises sensitive components and must be treated with caution. Observe the storage and operating conditions described in the ‘Technical Specifications’ section.
  • Not servicing/maintenance while the Thermometer is in use.
  • When using, shall not touch the battery and the patient simultaneously.
  • Do not use the device if it is damaged /degraded /lost in any way. The continuous use of a damaged unit may cause injury, improper results, or serious danger:
  • Based on the current science and technology, other potential allergic reactions are unknown.
  • This equipment needs to be installed and put into service in accordance with the information provided in the ACCOMPANYING DOCUMENTS.

OVERVIEW

Intended Use

The Non Contact Infrared Body Thermometer are designed to be used for intermittent measurement and monitoring of human body temperature by consumers in the home setting and primary care setting as a screening tool.

Description of Non Contact Infrared Body Thermometer

Device principle and introduction

  • The Noncontact Thermometers are hand-held, reusable, battery-operated devices, which can measure human body temperature on the forehead, and the skin temperature on one’s forehead.
  • The operation principle is based on Infrared Sensor technology. The IR sensor can out put different signals when measuring different object temperatures or in different ambient temperatures, and the ASIC can turn the signal from the IR Sensor to a digital value and display it on the LCD.

Description of Controls, Indicators, and Symbols

  1. LCD Display
  2. Battery Cover
  3. ON/ Scan Button
  4. Set Button
  5. MEMO Button
  6. MODE Button
  7. IR Sensor

iProven-NCT-978-Infrared-Forehead-Thermometer-fig-
\(1\)

Figure 1: iProven NCT-978 Infrared body thermometer

  1. Surface Mode
  2. Body Mode
  3. Digital Display
  4. Smile or Cry Indicator
  5.  Battery Indicator
  6. Buzzer on/ off Indicator
  7. Memory number
  8. °F
  9. °C
  10. Memory

Thermometer Applications

iProven-NCT-978-Infrared-Forehead-Thermometer-fig- 28

Equipment Symbols

|

Warning

| |

Compliance with WEEE Standard

---|---|---|---
|

Non sterile Packaging

| | DO NOT THROW AWAY Intended for multiple use
|

Refer to Operating instructions

| iProven-NCT-978-Infrared-Forehead-Thermometer-fig-
\(10\)|

Operating atmospheric pressure

iProven-NCT-978-Infrared-Forehead-Thermometer-fig-
\(10\)

|

Operating Temperature

| |

serial number

|

Operating Humidity

| |

recyclable

****|

manufacturer

| | This device compiles with Part 15 of FCC

( Federal Communications Commission) Rules.

| IP22: The first number 2: Protected against solid foreign objects of 12.5 mm Φ and greater. Thesecondnumber:Protectedagainstverticallyfallingwaterdropswhenenclosuretitled up to 1s .

Technical Specifications

Measurement Unit C/ T
Operating mode Adjustcdmodc(Bodymode) Directmode{surfacemode)
Measuring site Forehead
Reference Body Site Axillary
Rated output range Bodymode 35.0C· 42.0 C/95.0 °F -107.6°F Surface mode: 0.0

C -100.0 C / 32.0°F-212.0°F
Extendedoutputrange| Body mode: 34.0C – 34.9 C/ 93.2°F-94.8°F, 42.l C· 42.9 C /107.8-109.2 °F
Range| Body mode:34.0 C ·42.9 C / 93.2°F-1 09.2°F

Surface mode: 0.0 C -100.0 C / 32-212°F

Accuracy| Bodymode

34.0C-34.9 C :.t0.3 C / 93.2°F-94.8°F::t0.5°F;

35.0C – 42.0 C:.t0.2C /9S.0°F-107 .6°F:t0.4°F;

42.1 C· 42.9 C:±0.3C /107.8°F-109.2°F:±0.5 ° F:

Surface mode: :t2.0 C/ :t3.6°E
Display Resolution| 0.I C/0.l “f
Three-colorBacklight

(Color Alarm)

| 35.5 ‘ C•37.3°C/ 95.9°F-99.1 °F: Green (Norma l Temperature);

37.4 ‘C-38.U°C(.”-larm point) / 99.3°F-1U0.4°F: Yellow (Slig ht Fever)

38.1 °C.4 2.9°C / I00.6°F-lll9.2 ‘ F: Rcd(H igh l’cver)

Note: I.Surface mcxle is always with Green backlight.

2. In body mcxle 34.0″c-35.4 c is with green backlight.

Auto PowcrOffTime| :St8s
Measuring Time|
Measuring Distance| ICM -S CM( 0.4-Zi n)
Memories| 50
Power Supply Requirements

Batteries| l.SV (AAA) alkaline batteryX2 (IEC Type LR03)
Adaptable Range| 2.6V~3.6V
Environmental
Operating Condition| Operating Temperature:15.0″C ~3 S.O”C (S9.0°F~95.0°F), Relative Humidity:S85 % atmosphericpressure:70Kpa-106Kpa
Transport and Storage Condition| Storage Temperatu re: -20°C-+S S°C / ·4 l31 °E Relative llumid itys 93% atmosphericpressure:70-l06Kpa
Dimension and Weighting

Weight{withoutbatteries]| 90g
 | L:138mm X W:9Smm X H:40mm
Compliance
Item| Compliant with
Equipment classification| Safety Standards: EN6060 J-l: 2006+Al: 2013,E N6 0601-t-2:20 07
Type of protection| Internally powered equipment {on battery power]
Degreeofprotection| Non Applied part
Frontpanelandcaselabeling| ENIS015223·1:2012
Temperature| ENIS080601-2-56:2012
Home hea lthcare environment| EN60601-t-11:2010

Calculated values of the indicators according to ISO 80601-2-56

iProven-NCT-978-Infrared-Forehead-Thermometer-fig- 29

Note: the above value is calculated from clinical data of HTD8818D.

Safety classification of ME EQUIPMENT

iProven-NCT-978-Infrared-Forehead-Thermometer-fig-
\(15\)

Note: Not intended to be sterilized. Not for use in an OXYGEN RICH ENVIRONMENT

OPERATION

Battery installation

Caution: The Non Contact Infrared Body Thermometer does not operate with dead batteries and does not input outer power. Install new batteries.

  1. Pull the battery downward, toward the bottom of the Non Contact Infrared Body Thermometer, and remove the battery access door;
  2. Insert two pieces AAA size batteries according to the “+” and “-“;
  3. Close the battery cover:

How to Operate

Before Applying the Thermometer Be sure to read and understand all Warnings listed of the instructions before use.

  1. The thermometer is aligned with the middle of the forehead to measure body temperature (between the eyebrows above) and keep the vertical distance, press the On/Scan button, temperature display immediately, see figure 2.iProven-NCT-978-Infrared-Forehead-Thermometer-fig- \(16\)
  2. When the ambient temperature of the thermometer changes too much, such as moving the Thermometer from one place of lower temperature to another place of higher temperature, Allow the thermometer to remain in a room for 30 minutes where the temperature is between 59°F – 95°F or 15°C – 35°C.
  3. The ambient temperature around the test person should be stable, should keep away from the larger flow fan, air-conditioning vents and so on.
  4. When people moving from one place of lower temperature to another place of higher temperature, should at least remain in the test environment more than 5 minutes, to be consistent with the ambient temperature after the re-measurement.
  5. Wait at least 1 second for the next measurement. If the continuous measurement of five times, it is recommended to wait at least 30 seconds and then continue measurement.
  6. You cannot use the thermometer in place where the sun is strong.
  7. If for some reason the low forehead temperature measurement can try to align behind the ears. See figure 3.iProven-NCT-978-Infrared-Forehead-Thermometer-fig- \(17\)

General Setup and Use

Start measuring

  1. Turn on the thermometer by pressing the On/Scan button. The thermometer will perform self-test with all segments displayed for 2 seconds.
  2. Align staff forehead to keep the distance, and then press the On/Scan button to start the measurement, read the data.

Note:

  1. After full display over, you will hear a rattle or “beep beep beep” three times, which means that the measurements have been completed, while the target value of the measured temperature is displayed on the LCD, while backlit display according to the appropriate setting among the three colors red, green, yellow one of. And the Green means ready for next measurement. When 99’F – 100.4’F, it’s yellow ,means slight fever warning. Please pay attention to body temperature. When the body temperature is above 100.5 F, it’s red, means high fever. Please take action to cool down or go for a doctor:
  2. To ensure the accuracy of the measurement, wait at least 30 seconds after 5 consecutive measurements.

Mode conversion

  • When the device is running, press the MODE button to cycle conversion between “body” mode and “surface” mode.
  • “body” mode is used for measuring human body temperature, the “surface” mode is used to measure the surface temperature. (The factory default is “body” mode).

Recalling and Erasing Memory Data

  • The last temperature taken before the thermometer powers off is stored in memory, up to 50.

NCT-978 as below step:

  1. In the boot or shutdown state, short press the MEMO button to view the history of measured values.
  2. An empty memory cell shows “…. C” or “….. F”.
  3. Temperature readings can be stored in memory. Up to 50 temperature readings can be stored into the memory cells and automatically overwrite historical data.
  4. In boot mode, press the MEMO button until the LCD display “CLr”, which means that all stored data is cleared completely.

Parameter settings

This product can be set according to the subjects of different colors and different
environments data to meet the different characteristics of populations or individuals.
Long press the MODE button to modify the measurement parameters.

  1. Unit Set-F1
    Under the boot mode Long press SET button to enter F1, press the “MODE” or “MEMO” button to switch Celsius and Fahrenheit temperature units, press the SET button to confirm the unit settings (factory default is Fahrenheit ).

  2. Fever alert set-F2
    Under F1 state, press SET button to enter the F2, press the “MODE” button to decrease 0.1 C, press the “MEMO” button plus 0.1 C, long press to accelerate the speed of temperature regulation, and finally press the SET button to save. (The factory default is 38.1 C)

  3. Prompt sound settings-F3
    Under F2 state, short press SET button to enter F3, press MODE button or MEMO button to set voice switch, and press the SET button to confirm the settings. (The factory default is the voice Prompt to open).

  4. Overall temperature offset value-F4

    • To meet the different colors, different characteristics of the population, or the environment caused by seasonal temperature change is large that need for temperature detection and debugging.
    • Under F3 state, short press the SET button to enter F4, press the MEMO button to plus 0.1 ‘C, press the MODE button decrease 0.1 ‘C, long press fast subtraction temperature, and then SET button to confirm the parameter setting.
    • Parameter adjustment range: -5’C (23*Fand +5°C (41’F) (factory default is 0).
  5. Exit setting mode
    In the F4 mode, press the SET button will automatically turn off the screen, exit setting.

TROUBLESHOOTING

MESSAGE SITUATION SOLUTION

Temperature taken in not within Typical human temperature range.

(34.0C·42.9C or93.2’F – 109.Z’F ).

|

Make sure the forehead thennometer is for forehead measurement. not other human oodyslte.

| Measured over the distance 1-5crn(0.4-2 in)| Optimum measurement distance is 1cm(.0.4”)
Incorrect test position.| See figurc2 Measuringpo sitionanddi stance.
Sub jects forehead hair, Anti pyretic stickers. head with sweat.etc.| SubjectssitquietlyS-lOminutesbeforethe test
Some people’s body temperature is lower than the general population.| The main concern fever temperature
F4 overall temperature offset is set incorrectly| Adjustthetemperatureoffsetvalue
|

Operating temperature exceeds the range of specified temperature.

|

Move to a room within the operating range wait 30 minutes before taking temperature.

|

The screen flicker, automatic turn off.

|

Replace battery or the product has been damaged.needs repairs.

|

Battery capacity is too low. Taking Temperature is not allowed.

| Install a new battery
|

Ambient temperature changes too fast

|

Wait until the ambient temperature is stable.

| (l)Powerisoff.

(Z) lmproper battery installation.

(3)The battery is exhausted. (4}Display remains blank.

| (!)Press On/Scam button again. (2)Check the battery polarity. (3)Replacewithanewbattery. (4)Contact the retailer or service center.

REPLACING THE BATTERY

  • Open and release battery cover following indicator on the surface of battery cover. Before changing the battery be sure the system is already power off.
  • Remove the battery and replace with 2 new one, type AAA, Make sure align properly as indicated inside the battery cover .
  • Slide the battery cover back in until it snaps in place.
  • Do not dispose of used batteries in household waste. Take them to special local collection sites.
  • In case, if system is latched up after changing battery. You may not follow up the process of rule one. Just take off battery, waiting 30 sec, then load battery again.

Warning

  • Do not recharge, disassemble or dispose of in fire.
  • The typical service life of the new and unused batteries is 2000 measurements for the operation time is 18s.
  • Only use the recommended batteries, do not recharge non-rechargeable batteries, and do not burn them.
  • Remove the batteries if the thermometer is not to be used for a long period.

CLEANING, CARE AND STORAGE

  • The lens is very delicate.
  • It is very important to protect the lens from dirt and damage.
  • Use a clean, soft cloth to clean the surface of the device and LCD. Do not use solvents or immerse the device into water or other liquids.
  • Always keep the thermometer a within the storage temperature and humidity range as specified.
  • It is recommended to store the thermometer in a dry location free from dust.
  • Always keep the thermometer within the storage temperature range (- 20 C to 55 Cor – 4 F to 131 F) and humidity range (≤93% non-condensing).
  • It is recommended to store the thermometer in a dry location free from dust. Do not expose the thermometer to direct sunlight, high temperature/ humidity or any extreme environment, otherwise the function will be reduced.
  • When the ambient temperature of the thermometer changes too much, such as moving the thermometer from one place of lower temperature to another place of higher temperature, allow the thermometer to remain in a room for 30 minutes where the temperature is between 15 C to 35 C (59 F – 95°F).

DISPOSAL

  • Used batteries should not be disposed of in the household rubbish. Used Batteries should be deposited at a collection point.
  • At the end of its life, the appliance should not be disposed of in household rubbish. Enquire about the options for environment-friendly and appropriate disposal. Take local regulations into account.

WARRANTY

Our company warrants Non Contact Infrared Body Thermometer at the time of its original purchase and for the subsequence time period of one year.

The warranty does not cover the followings:

  • The device series number label is torn off or cannot be recognized.
  • Damage to the device resulting from misconnection with other devices.
  • Damage to the device resulting from accidents.
  • Changes performed by users without the prior written authorization of the company.

Batteries and packaging are not covered under warranty

When asked to provide warranty service, you must have a purchase date and purchase stamp dealers (including dealers name and address) of the warranty card. Be sure to ask the dealer to purchase this product signature on the warranty card. When asked to provide warranty service, please put the product to get our distribution points for repair. Products outside the warranty expires, will be charged accordingly.

Note:

  • If you have any problems with this device, such as setting up, maintaining or using, please contact with SERVICE PERSONNEL of us. Don’t open or repair the device by yourself.
  • Please report to us if any unexpected operation or events occur:
  • Calibration needed to ensure proper function for every two years or after device impact.
  • The patient is an intended operator. The patient can measure and change battery. Under normal circumstances and maintain the device and its accessories according to the user manual.

EMC Declaration

  • This equipment needs to be installed and put into service in accordance with the information provided in the ACCOMPANYING DOCUMENTS; This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided, and this unit can be affected by portable and mobile RF communications equipment.
  • Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
  • Caution: this unit has been thoroughly tested and inspected to assure proper performance and operation!
  • Caution: this machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used.

iProven-NCT-978-Infrared-Forehead-Thermometer-fig- 30

iProven-NCT-978-Infrared-Forehead-Thermometer-fig- 31

iProven-NCT-978-Infrared-Forehead-Thermometer-fig-
\(26\)

iProven-NCT-978-Infrared-Forehead-Thermometer-fig-
\(27\)

FREQUENTLY ASKED QUESTIONS

How does the iProven NCT-978 Infrared Forehead Thermometer measure temperature?

The iProven NCT-978 Infrared Forehead Thermometer utilizes infrared technology to measure body temperature without direct contact. It detects infrared energy emitted by the body and provides accurate temperature readings.

What special feature does the iProven NCT-978 Infrared Forehead Thermometer offer?

The iProven NCT-978 Infrared Forehead Thermometer features a non-contact design, allowing temperature measurement without physical contact, making it ideal for infants and young children.

What is the outer material of the iProven NCT-978 Infrared Forehead Thermometer?

The outer material of the iProven NCT-978 Infrared Forehead Thermometer is plastic, ensuring durability and lightweight construction.

What specification does the iProven NCT-978 Infrared Forehead Thermometer meet?

The iProven NCT-978 Infrared Forehead Thermometer meets FDA specifications, ensuring its safety and accuracy for temperature measurement.

What type of display does the iProven NCT-978 Infrared Forehead Thermometer have?

The iProven NCT-978 Infrared Forehead Thermometer features a digital display, providing clear and easy-to-read temperature readings.

What are the product care instructions for the iProven NCT-978 Infrared Forehead Thermometer?

The product care instructions for the iProven NCT-978 Infrared Forehead Thermometer advise wiping it clean after each use to maintain hygiene and functionality.

How many units are included with the iProven NCT-978 Infrared Forehead Thermometer?

The iProven NCT-978 Infrared Forehead Thermometer includes one unit, providing a single thermometer for temperature measurement.

What are the product dimensions and weight of the iProven NCT-978 Infrared Forehead Thermometer?

The iProven NCT-978 Infrared Forehead Thermometer has product dimensions of 2 x 0.01 x 0.01 inches and weighs 5.61 ounces, offering a compact and lightweight design.

What is the manufacturer of the iProven NCT-978 Infrared Forehead Thermometer?

The iProven NCT-978 Infrared Forehead Thermometer is manufactured by iProven, ensuring quality and reliability in its design and performance.

What type of batteries does the iProven NCT-978 Infrared Forehead Thermometer require?

The iProven NCT-978 Infrared Forehead Thermometer requires 2 AAA batteries for operation, which are included with the product for convenience.

What is the price of the iProven NCT-978 Infrared Forehead Thermometer?

The price of the iProven NCT-978 Infrared Forehead Thermometer is $19.97, offering an affordable option for accurate temperature measurement.

What age range does the iProven NCT-978 Infrared Forehead Thermometer cater to?

The iProven NCT-978 Infrared Forehead Thermometer is designed for infants, providing a safe and convenient way to measure their temperature.

What should I do if my iProven NCT-978 Infrared Forehead Thermometer is not turning on?

If your iProven NCT-978 Infrared Forehead Thermometer is not turning on, first, ensure that the batteries are inserted correctly according to the polarity markings. Try replacing the batteries with new ones.

How can I troubleshoot if my iProven NCT-978 Infrared Forehead Thermometer is displaying inaccurate temperature readings?

If your iProven NCT-978 Infrared Forehead Thermometer is displaying inaccurate temperature readings, ensure that you are following the correct measurement procedure as outlined in the user manual. Check for any obstructions on the forehead or lens of the thermometer.

What should I do if the display of my iProven NCT-978 Infrared Forehead Thermometer is not functioning properly?

If the display of your iProven NCT-978 Infrared Forehead Thermometer is not functioning properly, check for any signs of damage to the screen or connections. Ensure that the batteries are correctly installed and have sufficient charge.

VIDEO – PRODUCT OVERVIEW

DOWNLOAD THE PDF LINK:iProven NCT-978 Infrared Forehead Thermometer Instruction Manual

REFERENCE:iProven NCT-978 Infrared Forehead Thermometer Instruction Manual- Device.Report

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals