Regulus TZT 63 Electronic Plug-In Thermostat User Guide

June 4, 2024
Regulus

Regulus logo Kit for bathroom towel radiators
(electric heating element and TZT 63 electronic plug-in thermostat)
User Guide

Description

Bathroom towel radiators connected to a traditional hydronic heating system can be fitted with a kit for dual heating that contains an electric heating element, TZT 63  thermostat, and a T-piece. In this case, the heating fluid is heated up either by the electric heating element only, or also from the central heating circuit using the T-piece supplied. The heating element gets wired via the plug-in room thermostat where the desired temperature is set. Bathroom towel radiators with dual heating can be placed in zones 2 and 3 (next to a wash basin, bathtub, or shower cabin).
A comfortable heating element can be obtained by simply installing of recommended heating element into a radiator.

General Information

This Owner’s Manual is an integral and important part of the product and must be handed over to the User. Read carefully the instructions in this manual as they contain important information concerning safety, installation, operation, and maintenance. Keep this Manual for later reference.
The kit shall be installed by a qualified person according to valid rules and Manufacturer‘s Instructions.
Incorrect installation may result in serious injury to people and/or animals and property damage. This device is intended for heating and controlling local heaters and as a supplement to bathroom towel radiators.
The output of the el. the heating element shall be selected depending on the heat output of the radiator. The max permissible output of an electric heating element is shown in a Data Sheet for every radiator.
Never use a heating element of a bigger output than set by the manufacturer for the specific radiator type and size!
This electric heating element shall not be installed vertically with the electric cord pointing upwards. For a safe operation, it is necessary to ensure that the fluid inside can flow into an expansion vessel as it expands during heating up.
It is forbidden to use the appliance for other purposes than described above, and the Manufacturer bears no responsibility for any damage caused by improper or wrong use. For surface, cleaning use a soft cloth soaked in mild detergent. Never use abrasive cleaners or solvents.
Before performing any work or maintenance on the device, ensure that it is completely disconnected from the power mains. If the device shows signs of faulty operation, turn it off and call a service provider.

Technical Data

3.1 Plug-in Room Thermostat TZT 63
Temperature setting range: 5 – 35 °C in 0.5 °C increments
Timer setting ranges from 15 min. to 5 hours, in 15 min. increments
Temperature sensor: NTC
Power supply: 230 V~ / 50Hz
El. protection: IP20
Switch load: 230 V~, 16 (3) A
Operating temperature: 0 – 45 °C
Ambient temperature display range: 0 – 40 °C in 0.5 °C increments
Relative humidity  5 – 95 % (non-condensing)
3.2 Heating element
Working voltage: 230 V/50 Hz
Protection type: IP 44
Power input: 300 – 1500 W

Operation

The plug-in thermostat controls the temperature for the local heater; it shows either the set temperature or the measured one.
Description and adjustment of the thermostat mode
The thermostat TZT 63 turns on as soon as plugged in, ”On” and 20 °C temperature appears on the display. After a while, the real temperature is measured and kept displayed.
In this mode, the thermostat switches the heating on and off in such a way that the room temperature reaches the set value (the factory preset value is 20 °C).
Setting another temperature: press the up or down key, and the timer time starts flashing. Press OK (c-1 and the preset temperature starts flashing. It can be modified by pressing the up or down key, in the range from 5 to 35 °C in 0.5 °C increments. Press OK ( ). to save the value. The LCD returns to displaying “On” and the ambient temperature.
Description and adjustment of the timer mode
Switching from the thermostat mode to the timer mode is done by pressing OK ( ). The remaining time is displayed on the LCD together with a flame symbol (heating on). The countdown starts running, indicated by a flashing colon in the remaining time (factory preset value is 2:00 hours). After a short delay, the thermostat will switch the heating on. This is indicated by the lit green LED. The heating is turned on regardless of the ambient and preset temperatures.
Setting another timer value: press the up or down key, and the timer time starts flashing. The desired timer value can be set by pressing the up or down key between 15 min. and 5 hours, in 15 min. steps. Then press OK ( ). After one more pressing ( ) the display will show the timer and the flame symbol again (heating on). The preset timer value will be modified in case the appliance is the thermostat mode. When in timer mode, the timer value will be updated only after pressing twice the key OK ( ). Countdown starts. When the preset time expires, timer mode ends and the appliance returns to the thermostat mode. The display shows “On” and the ambient temperature again.
Regulus TZT 63 Electronic Plug In Thermostat - icon 3 Note: Temperature and countdown time can be changed from either thermostat mode or timer mode. After pressing OK ( ) the appliance will return to the mode preceding pressing the up or down key. If during the thermostat adjustment no key is pressed for 10 sec., the appliance will return to the mode preceding pressing up or down.
Warning: In case of a power supply interruption the modified values will be lost and the factory values set as default
Temperature Control

  1. Switching heating on Heating is switched on (the thermostat closed) if the ambient temperature is 0.5°C lower than the set temperature.
  2. Switching heating off: The heating is switched off (the thermostat is open) if the ambient temperature is 0.5°C higher than the set temperature.
  3. If the ambient temperature falls below 5°C, the frost protection mode is activated and heating switched on regardless of the desired temperature. The frost mode is indicated by the symbol

This electric heating element is equipped with an automatic thermal reset at 90 °C that will release again automatically when cooled down to 35 °C. The element is also equipped with a safety cutoff that turns it off permanently when the temperature exceeds 110 °C.
The kit for bathroom towel radiators also contains a T-piece that is needed for dual heating (when the radiator is a part of a heating circuit and also heated by a heating element if necessary).

Installation

A heating element shall be installed into a radiator according to the relevant safety and technical rules and standards, following the manufacturer‘s recommendations, and the installation shall be done by a qualified staff.

Maintenance

Once installed, this appliance requires almost no maintenance. In case the power cable suffers damage, disconnect the appliance from the mains and contact a specialized service. It is forbidden to perform any unauthorized repairs or modifications to the heating element or controller!

Disposal

7.1 Packing shall be disposed of in compliance with the valid rules.
IMPORTANT INFORMATION ON PROPER DISPOSAL OF E-WASTE AS REQUIRED BY THE EC DIRECTIVE 2002/96/EC (WEEE)
Do not dispose of this product as unsorted municipal waste.
Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling. Respecting these rules will help to preserve, protect and improve the quality of the environment, protect human health and utilize natural resources prudently and rationally. The crossed-out wheeled bin with a marking bar, printed either in the Manual or on the product itself, identifies that the product must be disposed of at a recycling collection site.

Regulus logo REGULUS, spol. s r.o.
Do Koutů 1897/3
143 00 Praha 4
http://www.regulus.eu
E-mail: [email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Regulus User Manuals

Related Manuals