Whitehall WH3745 Ligature Resistant Corterra Compact Basin
Specifications
- Model: WH3745
- Product Name: Ligature Resistant CorterraTM Compact Basin
- Weight: Approximately 46.5 lbs with faucet
- Dimensions: 2041 (515) x 321 x 18 (457) inches [MM]
- Fixture Design: Does not conform with ADA Accessibility Guidelines
Rough-In Dimensions
Wall Mounting Hardware is not provided. Installer needs to determine the Wall
Backing and Wall Mounting Hardware required based on fixture and Wall
construction.
Valve Pushbutton, Spout, and Tailpiece Installation
- Remove Mounting Channel from the Deck Assembly.
- Install the Faucet & Pushbutton assemblies.
- Connect the tubing before mounting to the wall.
- Install the Tailpiece.
Installation
Follow these steps for installation:
- Install Wall Anchoring Hardware as per specifications.
- Install P-trap and Valve following the provided instructions.
- Make up Supply and Waste Connections as necessary.
- Ensure proper alignment of the Skirt during] reinstallation.
Frequently Asked Questions (FAQ)
Q: Is Wall Mounting Hardware included in the package?
A: No, Wall Mounting Hardware is not provided. The Installer needs to
determine the suitable hardware based on the Wallconstruction.
Model WH3745
LIGATURE RESISTANT CORTERRATM
COMPACT BASIN
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER
1-800-743-8259
Technical Assistance E-mail:
Fieldservice@acorneng.com
IMPORTANT
Important: Some options may slightly alter installation. To ensure proper
installation review the manual thoroughly and verify rough-ins before
beginning any work. File this manual with the owner or maintenance personnel
upon completion of installation. Industry standard wall backing, for wall hung
fixtures, is required. Installer provided wall anchors and wall anchoring
hardware must be appropriate for wall construction. Valve Assembly:
Recommended working water pressure is 30 psi (2.07 bars) minimum to 100 psi
(6.89 bars) maximum. Maximum temperature is 130°F (54.4°C). Maximum outlet
temperature recommended is 105°F (40.6°C). Valve assembly must be drained
prior to being subjected to freezing temperatures. Prior to installation,
supply lines must be flushed of all foreign material such as pipe dope, chips,
or solder. Debris or foreign material in water supply may damage valve. Teflon
tape is recommended on all threaded waste and supply connections to reduce the
possibility of leaks.
Please refer to the Link or QR code provided.
For Cleaning & Care Guide:
https://www.whitehallmfg.com/uploads/fileLibrary/9900-008-W01.pdf
INSTALLATION, OPERATION & MAINTENANCE MANUAL WH3745
TECHNICAL DIMENSIONS
IMPORTANT
NOTE: Fixture weight is approximately 46.5 lbs with faucet (industry
standard wall backing, for wall hung fixtures, is required. Installer provided
wall anchors and wall anchoring hardware must be appropriate for wall
construction).
Fixture design does not conform with ADA Accessibility Guidelines.
NOTES :
- Utility Shelf
- 6″ Deep Bowl
- Anti-Ligature Trap Cover
- Wall Anchoring Hardware (By Others)
- Tamper Resistant Screws
General Notes
- All Dimensions are in Inches [MM].
- Dimensions shown are for recommended Adult Height.
ROUGH-IN DIMENSIONS (CONTINUED)
IMPORTANT
- NOTE: Dimensions shown based on 34” rim height. All vertical dimensions change accordingly with rim height that differs.
- Wall Mounting Hardware is not provided.
- Wall Backing shall be determined by Specifier or Installer as required to suit fixture and Wall construction.
- Wall Mounting Hardware shall be determined by Installer as required to suit Wall construction and/or Wall Backing.
- Fixture weight is approx. 60 lbs. (27 kg)
FRONT VIEW FROM FIXTURE SIDE
- 9/16” Lower Mounting Channel Mounting Points (6) places.
- 9/16” Upper Mounting Channel Mounting Points (2) places.
- 1-1/2” O.D. P-trap Waste Outlet (P-trap Provided).
- 1/2” NPS Hot and Cold Temperature Rough-Ins when applicable (Angle Stop By Others).
VALVE PUSHBUTTON, SPOUT, AND TAILPIECE INSTALLATION
- Deck Assembly
- Mounting Channel
- Faucet & Pushbutton Assemblies
- Tailpiece
- Remove Mounting Channel [2] from the Deck Assembly [1].
- Install the Faucet & Pushbutton [3] along with connecting the tubing as reaching this area will be harder once mounted to the wall.
- Install the Tailpiece [4]. See Strainer Tailpiece Assembly Page
INSTALLATION
Figure 1
- Strike a horizontal chalk line at 31-7/8” vertically, from the finished floor, on finished wall to indicate required deck height (34” standard). Strike a vertical chalk line to indicate centerline of fixture.
- Remove the Fixture Skirt [1] and align the frameassembly notches with vertical and horizontal chalk lines and mark and install wall anchors by others.
- Anchor frame [2] to wall using wall anchoring hardware (By others).
Figure 2
- Hang Deck Assembly [3] against Finished Wall, and slide down wall until the deck Mounting Channel [4] rests on Frame Mounting Channel [2].
- Secure Deck [3] by mounting Wall Anchoring Hardware (By Others) to the wall.
Figure 3
- Install P-trap [5] refer to Strainer Tailpiece & P-Trap Assembly page. Install Valve [6] refer to Valve page.
- Make up Supply and Waste Connections.
Figure 4
- Ensure the trim on the Skirt [1] lines up with the groove on the Deck Assembly [3] when reinstalling the skirt [1] as well as the back lip on the skirt [1] to the Mounting Channel [2].
IMPORTANT
- Tubing should already be installed on faucet along with pushbuttons as accessing these parts will be harder when mounted to the unit.
- Test Unit for proper usage and inspect for water leaks.
STRAINER TAILPIECE & P-TRAP ASSEMBLY
HINT: Teflon tape is recommended on all threaded waste and supply connections.
- Strainer w/ 1-1/2″ -16 UNE Threads
- .Rubber Gasket
- -1/2”-16 Brass Nut
- .Flat Fiber Washer
- -1/2″-16 x 1-1/4″ UNI Tailpiece
- -1/2” OD Waste Outlet Connection
- Install strainer to Basin using plumbers putty on underside of grid strainer flange. From beneath basin, assemble gasket, washer and jam nut as shown to strainer and tighten securely. Add close elbow to strainer assembly as indicated.
- Assemble waste piping using teflon tape on all threaded connections and make up waste connections to 1-1/2″ P-trap.
NOTE: Waste Assembly may be provided with Extra items not required in this
assembly.
NOTE: Waste Assembly may require field cutting and fitting by the installer.
TOP VIEW
VALVE INSTALLATION
- Remove screws [1] from Valve Mounting Bracket
- Hold Valve Assembly [3] against Mounting Bracket [2] and secure with Screws [1] into threaded insert [4].
Before making up the supply connections, the supply lines must be flushed of all foreign material such as pipe dope, pipe chips, solder, sand, etc.
ADJUSTING TIMING SCREW
Timing is adjustable from 5-60 seconds and is accomplished by rotating Timing Screw [1]. Turning the Timing Screw [1] clockwise increases metering time while turning the Screw counterclockwise decreases metering time.
M SINGLE TEMPERATURE METERING VALVE
M DUAL TEMPERATURE METERING VALVE
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone 800-782-7706 • 626-968-6681 • Web: www.whitehallmfg.com