Whitehall Manufacturing WHBF6 Ligature Resistant Drink Fountain with Bottle Filler Instruction Manual

June 9, 2024
Whitehall Manufacturing

Whitehall Manufacturing WHBF6 Ligature Resistant Drink Fountain with Bottle Filler Instruction Manual
Whitehall Manufacturing WHBF6 Ligature Resistant Drink Fountain with
Bottle Filler

Important: Some options may slightly alter installation. To ensure proper installation review the manual thoroughly and verify rough-ins before beginning any work. File this manual with the owner or maintenance personnel upon completion of installation. Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall anchors and wall anchoring hardware must be appropriate for wall construction. ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the local code authority and is the responsibility of the installer for verification. Valve Assembly: Recommended working water pressure is 30 psi (2.07 bars) minimum to 100 psi (6.89 bars) maximum. Maximum temperature is 130°F (54.4°C). Valve assembly must be drained prior to being subjected to freezing temperatures. Prior to installation, supply lines must be flushed of all foreign material such as pipe dope, chips, or solder. Debris or foreign material in water supply may damage valve. Teflon tape is recommended on all threaded waste and supply connections to reduce the possibility of leaks. Provide 110-120VAC/60Hz/3A(MAX) electrical receptacle for factory supplied 120VAC/9VDC, 100mAplug-in transformer.

NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National Electrical Code).

Instructions for Operation and Care of Best-Care WHBF6

PRODUCT DIMENSION

NOTES:

  1. LIGATURE RESISTANT GRID STRAINER

  2. BOTTLE FILLER SPOUT

  3. BOTTLE FILLER SENSOR

  4. CONCEALED DRINKING FOUNTAIN SENSOR

  5. LIGATURE RESISTANT TRAP COVER WITH
    ACCESS PANEL

  6. LIGATURE RESISTANT DRINKING BUBBLER

  7. 1-1/2 O.D. WASTE OUTLET

  8. WALL ANCHORING HARDWARE (BY OTHERS)

MOUNTING DIMENSIONS -ADA (Adult)

MOUNTING DIMENSIONS

A. Bottle Filler Hanger Bracket Mounting Points (3) Ø5/16″ Bottle Filler Hanger Bracket Mounting Points (3) Ø5/16″ Hardware. Anchors With Min. Pull-Out Force Of 1000 LBS Per Anchor.

B. Fixture Support Mounting – (4) Ø3/8″ x 5/8″ Mounting Slots For Installer Provided Wall Anchors And Anchoring Hardware. Anchors With Min. Pull-Out Force Of 1000 LBS Per Anchor.

C. Fixture Support Mounting – (2) Ø9/16″ Mounting Hole For Installer Provided Wall Anchors And Anchoring Hardware. Anchors With Min. Pull-Out Force Of 1000 LBS Per Anchor.

D. Trap Enclosure Mounting Points (3) Ø9/32″ Holes For Installer Provided Wall Anchors And Anchoring Hardware. Anchors With Min. Pull-Out Force Of 1000 LBS Per Anchor.

E.   (4) Ø1/4″ Valve Plate Mounting Holes

NOTES: Dimensions indicated () are for ADA frontal approach installation. Adjust vertical dimension () as required to comply with federal, state, and local codes. For Child ADA compliant parallel approach, decrease Bubbler discharge height to 30” maximum above finished floor. Provide clear  floor space as required

ROUGH-IN DIMENSIONS -ADA (Adult)

A. 120VAC, 60Hz, 3A (Max) GFCI Protected, Electrical Receptacle

B. 3/8″ NCT Angle Stops (By Others)

C. 1-1/2″ O.D. Waste Outlet

D. (2) Ø1/4″ Mounting Holes for Optional Water Filter Bracket

E. (4) Ø1/4″ Mounting Holes for Optional -BAT Battery Pack Mounting Plate

NOTES: Dimensions indicated () are for ADA frontal approach installation. Adjust vertical dimension () as required to comply with federal, state, and local codes. For Child ADA compliant parallel approach, decrease Bubbler discharge hei ht to 30” maximum above finished floor. Provide clear floor space as required.

OPTIONAL -MC MOUNTING CARRIER

INSTALLATION INSTRUCTIONS:

A- INSTALL HORIZONTAL SUPPORT 1 BRACKET ONTO VERTICAL UPRIGHTS 2 TO OBTAIN PROPER VERTICAL SPACING USING 1/4-20 UNC x 1/2″ BOLTS 3 PROVIDED. FLOOR ANCHORS AND FLOOR ANCHORING HARDWARE 4 ARE PROVIDED BY INSTALLER.
B- ANCHOR SUPPORT BASES 5 TO A RIGID FLOOR OR OTHER RIGID SUBSTRUCTURE WITH INSTALLER PROVIDED HARDWARE 4 . SEE DETAIL.
C- INSTALL 1/2″-13 UNC x 4″ THREADED MOUNTING STUDS 6 NUTS 7 AND WASHERS 8 ONTO HORIZONTAL SUPPORT BRACKET 1 .
NOTE ENSURE THERE IS AT LEAST 1″ ENGAGEMENT OF MOUNTING STUDS 6 INTO BRACKET 1 AND 1″ BEYOND FINISHED WALL AS SHOWN IN DETAIL “A”.
D- ALIGN AND POSITION FOUNTAIN ONTO MOUNTING STUDS 7 . SECURE WITH REMAINING HARDWARE TO COMPLETE INSTALLATION.

FIXTURE ANCHORING

Mount Bottle Filler Bracket 1 and Drinking 1 Fountain Deck 2 to the wall using appropriate mounting and anchoring hardware 3, provided by installer.
FIXTURE ANCHORING

Prep the Bottle Filler Assembly 4 by removing the four 2(4) locknuts 5, washers 6 and setting them in a secure location. Insert bottle filler drain hose 7 through hole 8 at the bottom of bottle filler assembly 4 and connect to drain adapter 9 and secure with spring hose clamp 10 Feed bottle filler riser tube 11 and electrical wiring 12 through bottom hole 8.

FIXTURE ANCHORING

Feed Bottle Filler Waste Hose, Riser Tube and Electrical Wiring bundle 13 through fountain deck hole 14.

FIXTURE ASSEMBLY

Push Bottle Filler Housing  against the 4 wall. Slide it downward so it engages with wall bracket 1 and the four bolt 15 go into the deck slots 16.

Secure Bottle Filler 4 to Drinking Fountain Deck 2 using the four lock nuts 5 and washers 6

Install grid strainer 1 to basin using plumbers 6putty on underside of grid strainer flange.Insert rubber gasket 2 over the grid strainer 1, then drain body collar 3, brass washer 5 and secure with chrome plated nut 6. Slide bottle filler drain hose 4 onto drain collar nipple 3 and secure with spring hose clamp. Screw 1-1/4” O.D. tailpiece 7 into bottom of grid strainer 1.

INSTALLATION

  1. Strainer w/ 1-1/2″ – 16 UNE Threads & 1-1/4″-27 UNI Threads
  2. Rubber Gasket
  3. Drain Collar Assembly
  4. Bottle Filler Drain Hose With Spring Hose Clamp
  5. Brass Washer
  6. 1-1/2″ – 16 UNI Rough Chrome Brass Nut
  7. 1-1/4″ – 27 UNE Tailpiece 4″ Long

VALVE INSTALLATION

Install wall anchors 1, provided by installer, 7at Valve Plate dimensions on page (3). Secure Valve assembly 2 to wall using installer provided screws 3.

VALVE INSTALLATION

OPTIONAL FILTER INSTALLATION

With installer provided screw 3 not fully engaged, push Filter Head bracket 4 against the wall and push down onto screws 3 and secure bracket

OPTIONAL FILTER INSTALLATION

With Filter Head Assembly 4 secured to the wall insert Filter 5 and turn clockwise to tighten.

SENSOR OPERATION WIRING DIAGRAM;

IMPORTANT: Transformer must be plugged into a GFI protected circuit. Fixture must be earth grounded per N.E.C. or applicable codes.

WIRING DIAGRAM

WATER PATH;

WATER PATH

PUSH-IN FITTING INSTALLATION
NOTE: FITTINGS AND TUBE SHOULD BE KEPT CLEAN, BAGGED AND UNDAMAGED PRIOR TO INSTALLATION.

TO CUT TUBE:
Cut to fit length of 1/4” PE tubing and remove any burrs or sharp edges. Ensure that the outside diameter is free from score marks. Tube ends should be square.

TO CUT TUBE

INSERTING THE TUBE:

  1. Firmly and fully insert the tubing end into the push-in fitting up to the tube stop located approximately ½” deep

  2. Pull on the fitted tubing to ensure it is secure. Tube should not come free from the fitting. Water test the connection assembly prior to leaving the site to ensure there are no leaks.
    INSERTING THE TUBE

  3. DISCONNECTING THE TUBE:
    To disconnect the tube from the fitting ensure that the water line is depressurized. Push collet square towards the push-in fitting body and hold. While holding the collet in, pull on the PE tubing to remove from the push-in fitting.

ACCESS PANEL INSTALLATION

ACCESS PANEL INSTALLATION

Install P-Trap cover using #10-32 x 1/2” center reject hex head screws provided. Secure bottom of P-Trap cover to wall with wall anchors and anchoring hardware provided by installer.

9 VOLT DC SENSOR OPERATED VALVES

NORMAL VALVE FUNCTION:

9 Volt DC sensor operated valve has flow time of 90 seconds maximum. To reactivate, the user must move out of and return to the sensing area.

_ _CONDITION:__ WATER DOES NOT FLOW

INDICATORS:| PROBABLE CAUSE:| SOLUTION:
Sensor flashes continuously every two seconds when hands are within range.| – Low battery warning.| – Replace battery.
Sensor does not flash when the users hands are within range.| – Circuit breaker tripped.| – Reset circuit breaker.
– Battery completely used up.| – Replace battery.
– Defective 9VDC transformer.| – Replace transformer.
– Transformer polarity crossed.| – Replace transformer. (Sensor may be damaged & need replacement.)
– Unit is in “Security Mode” after 90 seconds of constant detection.| – Remove sources of detection. Wait 30 seconds before checking.
– Range is too short.| – Increase range.
– Range is too long.| – Decrease range and wait 30 seconds.
– Sensor is picking up a highly reflective surface.| – Eliminate cause of reflection. Wait 30 seconds before checking.
– Defective sensor.| – Replace sensor.
Sensor flashes once when the users hands are within range.| – Stops or water main closed.| – Open stops or water main.
– Bad sensor to solenoid connection.| – Ensure wires make proper contact.
– Debris or scale in solenoid assembly.| – Remove solenoid, pull out plunger and spring, and clean with scale remover solution or pressurized air.
– Debris or scale in diaphragm.| – Remove diaphragm and clean.
– Debris or scale in strainer.| – Remove strainer and clean.
_ _CONDITION:__ WATER CONTINUOUSLY
INDICATORS:| PROBABLE CAUSE:| SOLUTION:
Sensor flashes when users hands are within range.| – Debris or scale in diaphragm.| – Remove diaphragm and clean.
– Diaphragm is defective or torn.| – Replace diaphragm.
Sensor does not flash when the users hands are within range.| – Sensor is dirty or covered.| – Clean or uncover sensor and wait 30 seconds.
– Range too long or Highly Reflective Surface, Sunlight, Bright Lights, etc. are Triggering Sensor.| – Decrease range and wait 30 seconds.
– Eliminate cause of reflection or Correct Lighting Correct Lighting Problem.
_ _CONDITION:__ WATER FLOWS CONTINUOUSLY BUT STOPS WHEN HANDS ARE WITHIN RANGE
INDICATORS:| PROBABLE CAUSE:| SOLUTION:
Water runs continuously when sensor not activated. Sensor flashes when hands are within range and water shuts off.| – Solenoid polarity crossed.| – Disconnect solenoid and reverse polarity.
Description| Part No.| Diagram
---|---|---
HARDWARE
#10-32 x 1/2” UNF White Button Head Screw With Center Reject Pin| 0112-044-000|
1/4”-20 UNC Nylon Locknut| 0304-018-000|
PIPING COMPONENTS
**** Ligature Resistant Bubbler| **** 4854-020-001|
****
1/4” O.D. Tube Push-In 1/4 Turn Valve| **** 7000-420-000|
****
1/4” O.D Push-In x 1/4” O.D. Stem Elbow| **** 1895-709-000|


**** Y-STRAINER| **** 7000-021-001| REPAIR
PARTS
ELECTRONIC HARDWARE
**** 9VDC Plug-In Transformer| **** 0710-735-001|
9 VDC Battery-Pak Assy (6 AA Batteries Not Included)Battery-Pak Mounting Bracket| 0710-358-001 6155-013-199|
Description| Part No.| Diagram
---|---|---
ELECTRONIC HARDWARE (Continued)
Bottle Filler Nano Sensor Assembly| ** 2563-380-001| REPAIR
PARTS
**
Drinking Fountain Nano Senor Assembly| ** 2563-390-001| REPAIR
PARTS
**
2-Station Electronic Valve Assembly| **** GVL00B19-001|
WASTE COMPONENTS
Bottle Filler Drain Hose| GVL00B02-199| REPAIR
PARTS
Ligature Resistant Strainer| KYSCY002-001|
Rubber Gasket| 4935-011-000|
Drain Collar| GVL00B01-003|
BRASS WASHER| ** 4950-007-000| REPAIR
PARTS
**
Spring Hose Clamp| 7003-184-000|
Strainer Hex Nut| 4950-006-199|
Description| Part No.| Diagram
---|---|---
WASTE COMPONENTS (Continue)
****
1-1/2” O.D. Chrome Plated P-Trap| **** 4953-001-000|
ENCLOSURES
****
P-Trap Cover| **** GVL00B13-001| ****

Mailing Address:
P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A
Physical Address:
15125 Proctor Avenue • City of Industry, CA 91746 U.S.A
Phone 800-782-7706626-968-6681
Fax 626-855-4862
Web: www.whitehallmfg.com
E-mail: info@whitehallmfg.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals