Specifications
-
Product Name: Blower with RF Remote Control
-
Model Number: M16MI328 A02_01/18
-
Power Source: 2 x AA Batteries (LR6)
-
Operating Modes: Auto mode, Comfort mode, Eco mode, Frost
protection mode, Time and date setting mode, Programming mode,
Settings -
Display Features: Temperature setpoint, Heating/cooling
indicator, Gauge consumption, Pilot wire signal indicator, Measured
ambient temperature, Boost indicator light, Open window detection
indicator, Low battery indicator, Occupancy detection indicator,
Radio transmission indicator, Keypad locked indicator, Min/Max
value indicator, Days of the week (1=Monday … 7= Sunday)
Product Usage Instructions
Installing Batteries
-
Remove the battery cover from the front of the thermostat.
-
Insert the 2 AA batteries supplied, ensuring correct
polarity. -
Replace the battery cover.
Mounting of Thermostat
-
Unscrew the 2 screws under the thermostat to remove the
wallplate. -
Secure the wall plate using the provided screws in the
horizontal and vertical holes. -
Replace the thermostat on the wallplate and secure with locking
screws. -
Insert the 2 pins inside the wallplate, slide the stand to the
right, fold and lock it into the wallplate. -
Tilt the thermostat for optimal placement in the room.
Controls and Display
The product features a variety of controls and display
indicators including temperature setpoint, operating modes,
backlight settings, and various indicators for different
functions.
RF Pairing and Management
To pair the remote control with the blower:
-
In frost protection mode, press a specific button for 5 seconds
to initiate pairing. -
Complete the pairing process on both the remote control and
blower to establish a connection. -
Once paired successfully, a symbol will appear on both devices
indicating the connection. -
Check RF signal strength if required.
FAQ
How do I change the operating mode on the thermostat?
To change the operating mode, use the thermostat buttons to
cycle through Auto mode, Comfort mode, Eco mode, Frost protection
mode, Time and date setting mode, Programming mode, and
Settings.
What should I do if the low battery indicator is
displayed?
If the low battery indicator appears, replace the batteries with
new ones to ensure proper functionality of the thermostat.
EN INSTRUCTION MANUAL
BLOWER WITH RF REMOTE CONTROL
‘ ,
M16MI328 A02_01/18
EN
TABLE OF CONTENTS
Pack contains………………………………………………………………………………………
……………………………………………………………………………………………………………………..1 Installing
batteries……………………………………………………………………………………….
……………………………………………………………………………………………………………………..1 Mounting of thermostat
……………………………………………………………………………… ……………………………………………………………………………………………………………………..1
Controls and display ……………………………………………………………………………
……………………………………………………………………………………………………………………..2 RF Pairing and
management…………………………………………………………………………
……………………………………………………………………………………………………………………..2
Operating……………………………………………………………………………………………
……………………………………………………………………………………………………………………..3 Power on /standby mode
……………………………………………………………………………..
……………………………………………………………………………………………………………………..3 Selecting the operating
mode……………………………………………………………………….
……………………………………………………………………………………………………………………..3 Boost feature
………………………………………………………………………………………………
……………………………………………………………………………………………………………………..4 Super comfort (only if the
device is a blower)…………………………………………………
……………………………………………………………………………………………………………………..4 Gauge consumption, energy
savings……………………………………………………………..
……………………………………………………………………………………………………………………..4 Setting the comfort mode
temperature…………………………………………………………
……………………………………………………………………………………………………………………..5 Consumption indication
accumulated in kwh, energy savings ………………………..
……………………………………………………………………………………………………………………..5 Child anti-tamper, keypad
lock/unlock ………………………………………………………….
……………………………………………………………………………………………………………………..5 7 day and daily programme
integrated, energy savings ………………………………….
……………………………………………………………………………………………………………………..5 Automatic programming with
self-learning process……………………………………….
……………………………………………………………………………………………………………………..5 7 day and daily programme
…………………………………………………………………………. ……………………………………………………………………………………………………………………..5
Open window detection, energy savings……………………………………………………….
……………………………………………………………………………………………………………………..8 Information about remote
control by pilot wire …………………………………………….
……………………………………………………………………………………………………………………..8
User settings……………………………………………………………………………………….
……………………………………………………………………………………………………………………..9 Access
…………………………………………………………………………………………………………
……………………………………………………………………………………………………………………..9 Setting the eco mode
temperature lowering-level………………………………………….
……………………………………………………………………………………………………………………..9 Setting the frost protection
temperature ………………………………………………………
……………………………………………………………………………………………………………………..10 Super comfort (only if the
devis is a blower) activation/deactivation ………………
……………………………………………………………………………………………………………………..10 Comfort setpoint temperature
limit……………………………………………………………… ……………………………………………………………………………………………………………………..10
Setting of the maximum duration of authorised boost…………………………………..
……………………………………………………………………………………………………………………..10 Setting of the maximum
ambient temperature for the automatic stop of the
boost………………………………………………………………………….
……………………………………………………………………………………………………………………..11 Restoring factory settings
(only if Pin code is desabled) ………………………………….
……………………………………………………………………………………………………………………..11
Installer settings …………………………………………………………………………………
……………………………………………………………………………………………………………………..11 Access
…………………………………………………………………………………………………………
……………………………………………………………………………………………………………………..11 Configuration of detection
modes…………………………………………………………………
……………………………………………………………………………………………………………………..12 Dual optimization
feature…………………………………………………………………………….
……………………………………………………………………………………………………………………..12 Pin code
lock………………………………………………………………………………………………..
……………………………………………………………………………………………………………………..12 Restoring factory settings
(only if Pin code is desabled) …………………………………
……………………………………………………………………………………………………………………..14
Expert settings …………………………………………………………………………………..
……………………………………………………………………………………………………………………..14 Access
…………………………………………………………………………………………………………
……………………………………………………………………………………………………………………..14 Ambient temperature sensor
adjustement…………………………………………………….
……………………………………………………………………………………………………………………..15 Restoring factory settings
(only if Pin code is desabled) ………………………………….
……………………………………………………………………………………………………………………..15
Troubleshooting ………………………………………………………………………………….
……………………………………………………………………………………………………………………..16 Technical specifications
………………………………………………………………………. ……………………………………………………………………………………………………………………..16
Recycling and compliance declaration…………………………………………………..
……………………………………………………………………………………………………………………..16
EN
PACK CONTAINS
x2
Screw Anchor
x2
Screw for base attaching
x2
AA Batteries (LR6)
x1
Thermostat table stand
INSTALLING BATTERIES
1- Remove the batterie cover which is placed on the front of the thermostat.
2- Insert the 2 AA
3- Replace the batterie
batteries supplied.
cover.
Note the correct
polarity according
to the engraving on
the thermostat when
inserting the batteries.
· On the wall
MOUNTING OF THERMOSTAT
3- Secure the wall plate with the two screws provided using the horizontal and vertical holes.
4- Replace the thermostat on the wallplate.
1- Unscrew the 2 screws under the thermostat.
2- Remove the wallplate from the thermostat.
x2
5- Secure the thermostat by screwing the locking screws under the thermostat.
· LCD Display (Indicators overview) x2
· On the table stand
1- Insert the 2 pins inside the wallplate.
2- Slide the stand to the right.
3- Fold the stand and lock it into the wallplate.
4- Tilt the thermostat according to its placement in the room. 2 tilts are available.
30°
37°
Temperature setpoint / Information
Heating/cooling indicator
Gauge consumption
Pilot wire signal indicator
Measured ambient temperature Boost indicator light Open window detection indicator
Low battery indicator Occupancy detection indicator
Radio transmission indicator
Keypad locked
Min/Max value indicator
Days of the week (1=Monday … 7= Sunday)
Operating modes: Auto mode – Comfort mode – Eco mode Frost protection mode –
Time and date setting mode Programming mode – Settings
Important: In Auto, Comfort, Eco and Standby mode, backlight turns off automatically after 4 seconds if no buttons are pressed. It will be necessary to reactivate it by pressing one of the keypad buttons before making settings.
CONTROLS AND DISPLAY
RF PAIRING AND MANAGEMENT
RF pairing between the remote control and the blower
The remote control and the blower are not paired together at the factory, then
proceed as follow:
1- From frost protection mode, press
for 5 seconds.
To cancel the pairing process, press any button.
Thermostat buttons overview
Batteries compartment
Selecting operating modes Plus and minus buttons, used to set temperatures,
time, date and programmes Save settings
Boost button
Rotary dial
LCD display
2- The remote is in pairing mode. Then proceed to the device control pairing (Perform the same manipulation on the blower. From Frost protection mode, press OK for 5 seconds. The blower is in pairing mode).
5 sec.
3- When both device and remote control are linked, the symbol appears and is constantly displayed. The device returns automatically to the frost protection mode.
4
Check the RF signal strengh (only if paired)
POWER ON /STANDBY MODE
You can check at any time the RF transmission performance between the device
and the remote control.
To view the RF reception level, from Frost protection mode, press seconds.
Then the level appears on the display.
When the blower is on standby mode, 2 lines for 5 appear on the remote control display.
To exit standby mode, press the standby
button. C
Level of the remote control
Level of the connected device.
Power on feature
When this feature is first used, press the button (switch) so that it switches
to the I located below the blower to put the device in operation.
5 sec.
SELECTING THE OPERATING MODE
0 = High RF transmission level, the location of the remote control is
optimized.
9 = Low RF transmission level:
To improve the RF transmission performance between the 2 devices and ensure
the remote management is optimized: – Please ensure the RF transmission is not
interrupted, move the remote
control. – Move the remote control closer to the device.
The
button allows you to adapt the
operating schedule of your device to your
needs, depending on the season, whether
your home is occupied or not.
By pressing the
button once or several
times, select the required mode.
Mode sequence:
When the remote control is paired with the blower, the blower buttons are disabled.
RF pairing cancellation
You can cancel at any time the RF transmission between the device and the remote control.
From frost protection mode press simultaneously
and
for 5 seconds.
Auto
Comfort
Eco
Mode overview
·
Auto Mode
In Automatic Mode, the device will automatically change from Comfort mode to Eco mode according to the established programme.
Frost protection Display
5 sec.
2 different cases depending on your set-up:
1 7 day and daily programme Your device has been programmed and is executing
Comfort and Eco mode orders in line with the settings and time periods you
have selected (see “7 day and daily programme integrated” chapter page 5).
2 Programming by pilot wire If you do not want to use the programming feature.
The device equipped with occupancy detector is delivered by default with the
self-learning mode enabled. Orders sent by the pilot wire will only be applied
in Auto mode, thus your device will automatically receive and apply the
programmed orders sent by your power manager or your time switches (see
“Information about remote control by pilot wire” chapter page 8).
The symbol disappear from the display, the remote control and the device are not associated anymore.
· Comfort mode Non-stop Comfort mode. The device will operate 24 hours a day to achieve the temperature which has been set (e.g. 19°C). The Comfort mode temperature level can be set by the user (see page 5).
The symbol disappears from the display, the remote control and the device are
not associated.
OPERATING
· Eco mode Eco, which means the Comfort Mode temperature minus 3.5°C. This enables you to lower the temperature without having to reset the Comfort Mode temperature. Select this mode for short-term absences (between 2 and 24h ) or during the night.
Before carrying out any setting procedures, ensure that the keypad is indeed unlocked (see page 5).
5
Mode overview
· Frost protection mode This mode enables you to protect your home against the
effects of cold weather (frozen pipes, etc.), by maintaining a minimum
temperature of 7°C in it at all times. Select this mode when you will be away
from your home for a long time (more than 5 days).
Display
– If the ambient temperature reaches the maximal Boost temperature during the
count:
The blower switches off but the Boost mode is always active: the count is
always displayed, the Boost symbol and the heating indicator flash on the
display. When the temperature drops under the maximal authorised temperature,
the blower will be restarted until the count ends.
Restoring factory settings: See page 15.
BOOST FEATURE
– Second press: Boost cancellation.
The cursor moves above the previous active mode and the setting temperature
appears.
Important: the Boost mode can be enabled at any time, whatever the current operating mode (Auto, Comfort, Eco or Frost protection).
To activate Boost mode, press
the desired temperature setting will be set
at maximum for the time period you request.
60 minutes display will flash by default.
– First press: Boost
SUPER COMFORT (POST-VENTING SEE BLOWER USER MANUAL P. )
The blower could be used as an instant additional heating in case of an
important difference between the ambient temperature and the desired
temperature setting. The Super Comfort switches on if the difference between
the ambient temperature and the setting temperature is higher than 2°C. The
Super Comfort is enabled by default (see chapter “User settings” page 9 then
Super Comfort mode page 10).
Comments: – If the heating indicator is switched on, the blower switches on
and heats the
room in addition to the heat emitted by the device. – At any time, you can
modify the Boost duration from 0 to the maximal authorised
duration of the Boost, such as defined during the advanced settings (see page
10 for more details) by intervals of 5 minutes by turning the dial. this
modification will be saved and effective for the next Boost.
Example: the device is in Eco set 17,5°C, you decide to switch in Comfort
mode: the difference between 21°C and 17,5°C is 3,5°C, so higher than 2°C. The
blower starts up automatically to help the temperature increase and attain the
21°C desired. The Boost symbol and the heating indicator appears on the
display and the cursor above the selected mode will flash.
scf and the setting temperature Super Comfort appears on the display.
The Super Comfort stops if: – The difference is less or equal to 0,5°C. – The
difference is always higher than 2°C after 1hr of Super Comfort.
Comment: the Super Comfort is valid in Comfort and Auto-Comfort mode only.
The Boost can stop for 3 different reasons:
– An order “Stop” has been sent by your energy manager through the pilot wire:
C
The blower stops, — appears. The cursor moves above auto. When the order
Comfort will be sent, the device will be restarted until the count end.
– FIL appears on the display
GAUGE CONSUMPTION, ENERGY SAVINGS
France’s Agency for Environment and Energy Management (ADEME) recommends a
Comfort setting temperature lower or equal to 19°C. In the device display, an
indicator shows the energy comsumption level by positioning it in front of the
colour: red, orange or green. You can choose your level of energy usage,
depending on the setting temperature. As the temperature setting increases,
the consumption will be higher. The gauge appears in Auto, Comfort, Eco and
Frost protection modes and whatever the temperature level.
C – Red colour High Temperature level: it
is advisable to significantly reduce the setting
temperature.
Setting temperature > 22°C
When the setting temperature is higher
than 22°C
The blower continues to operate but does not heat up. If the controller is a
blower, check if nothing is put in front of the ventilation grid to not block
the air flow. The filter could be plug by dust, it must be cleaned.
Comment: on a blower, if the filter is obstructed or if the grid is covered
involuntary, a special sensor switches off the device. The normal operating of
the device will start again at the next start-up, if the filter or the grid is
not obstructed, and only after the device has cooled down.
B – Orange colour Average temperature level: it is advisable to slightly reduce the setting temperature.
19°C < Setting temperature 22°C
When the setting temperature is higher than 19°C and lower or
equal to 22°C
A – Green colour Ideal settings.
Setting temperature 19°C
When the setting temperature is lower or
equal to 19°C
6
SETTING THE COMFORT MODE TEMPERATURE
You can access the Comfort temperature set up from the Auto and Comfort Modes.
It is preset to 19°C.
Using the rotary dial, you can adjust the temperature from 7°C to 30°C by
intervals of 0.5° C. Note: you can limit the Comfort temperature, see page 10
for more details.
DAY AND DAILY PROGRAMME INTEGRATED, ENERGY SAVINGS
AUTOMATIC PROGRAMMING WITH SELF-LEARNING PROCESS
This feature is available on products equipped with occupancy detector.
Overview
Auto-programming (Auto): After an initial learning period of one week, the
device will analyze occupancy cycles to determine and implement a weekly
programme adapted to your lifecycle alternating periods in comfort and periods
in eco, the goal being to deliver the most efficient yet comfortable and user
focused heating cycle. The products algorithm will perpetually learn and adapt
to changes in your occupancy patterns, adapting week after week to optimize
the heating programme to any changes in your evolving occupancy patterns.
CONSUMPTION INDICATION ACCUMULATED IN KWH, ENERGY SAVINGS
It is possible to see the estimation of energy consumption in kWh since the last reset of the energy meter.
Display of the estimated power consumption
To see this estimation, from Auto, Comfort, Eco or Frost protection mode, then press .
To exit the display mode of
consumption: press
or , the device
returns automatically in the previous active
mode.
Resetting the energy meter
To reset the energy meter, from Auto, Comfort, Eco or Frost protection mode, then proceed as follows.
1- Press .
2- Press simultaneously
and
for more than 5 seconds.
To exit resetting the energy meter, press any button, the device returns automatically in the previous active mode.
CHILD ANTI-TAMPER, KEYPAD LOCK/UNLOCK
Keypad lock
To lock the keypad, press and hold the
and
buttons for 10 seconds. The padlock
symbol appears on the display, the keypad
is locked.
Operating
Upon the first activation of your device, the mode “auto-programme” is activated by default, in mode Auto. To deactivate and change the programme, see choice and affectation of programmes page 7. The first week of operation is a learning week during which the device memorizes your habits and elaborates a programme for the week. It therefore defines a programme built up of periods of Comfort and Eco, independently for each day of the week. During this learning week, the device will provisionally function in permanent “Comfort” mode.
Example of display in Comfort period
Example of display
Important: To ensure the auto-programming is
in Eco period
optimized, please ensure the presence detection sensor is not obstructed by an
external source, refer to your device’s instruction manual.
Application of the intelligent programme
One week after switching on, the device will apply the new programme for the
next 7 days. Then week after week the device will continue to optimize the
intelligent programme “Auto”, adjusting the Comfort and Eco periods to fit
closely to your lifestyle. When the product is in Frost protection mode or in
standby mode for more than 24 hours, learning and optimization of the
intelligent programme stops: the device stores the previously recorded
programme from the last week before switching to the Frost protection or
standby mode.
– Example 1: If the product is installed in mid-season or if its installation
is anticipated on the construction site, it can be switched on in standby
mode. When you select the Auto mode, the learning week will start
automatically. The device will be in permanent comfort and will memorize your
habits to apply the adapted programme the following week.
– Example 2: You select frost protection mode before going on holiday. Upon
your return, when you return to Auto mode, the unit will automatically apply
the previously stored intelligent programme from the last week before you
left.
In the case of control by pilot wire coming from an energy manager for
example, the pilot wire will take precedence over the AUTO programme which
results from the Self-learning algorithm.
Keypad unlock
To unlock the keypad, press and hold the
and
buttons for 10 seconds
again. The padlock symbol disappears from the display, keypad is unlocked.
Important: when the keypad is locked, only the button (or switch) is active.
If the device is on Standby mode when the keypad is locked, you have to unlock
it for the next heating on to access the setup.
DAY AND DAILY PROGRAMME
In this mode, you have the option of programming your device, by setting one of the five programmes on offer for each day of the week.
Access to the programming mode
From Auto, Comfort, Eco or Frost protection mode, press enter into the
programming mode.
Schematic sequence of programming settings:
for 5 seconds to
Setting time
Setting day
Programmes choice
7
Setting day and time
In this mode, you can set day and time to programme your device in line with
your needs.
Programmes choices
Schematic sequence of programmes:
1- From Auto, Comfort, Eco or Frost protection mode, press
for 5 seconds.
Auto
Comfort
Eco
P1
P2
P3
Version with occupancy detector: The device is delivered by default with the
self-learning mode enabled as described on page 5. If this programme suits
your requirements, you have nothing more to do, the device, after the initial
7 day learning period will follow the autoprogramme which will continue to
tailor itself to your occupancy cycles.
Other version: your device’s default setting is non-stop Comfort for 7 days a
week.
5 sec. The clock symbol appears.
2- Select using
or
. The hours figures will flash.
The hours will scroll quickly if you hold the
or
buttons.
by pressing .
Save
Programmes overview
– Auto: Auto-programming (See Automatic programming with selflearning process
page 5).
– Comfort: your device will operate in Comfort mode, 24 hours a day, for each
day selected. Note: You can set the Comfort mode temperature to the
temperature you require (see the Setting the Comfort mode temperature section
page 5).
– Eco: The device will operate 24 hours a day in Eco mode. Note: You can set
the temperature lowering parameters (see page 9).
– P1: your device will operate in Comfort mode from 06:00 to 22:00 (and in Eco
mode from 22:00 to 06:00).
– P2: your device will operate in Comfort mode from 06:00 to 09:00 and from
16:00 to 22:00 (and in Eco mode from 09:00 to 16:00 and from 22:00 to 06:00).
– P3: your device will operate in Comfort mode from 06:00 to 08:00, from 12:00
to 14:00 and from 18:00 to 23:00 (and in Eco mode from 23:00 to 06:00, from
08:00 to 12:00 and from 14:00 to 18:00).
1
2
3- The minutes figures will flash. Select using
or
.
Save by pressing .
Potential modifications of programmes
If the default time schedules for the P1, P2 and P3 programmes do not suit
your routines, you can change them.
Modifying the P1, P2 or P3 programmes. If you modify the time schedules for
the P1, P2 or P3 programmes, the schedules will be modified for all the days
of the week for which P1, P2 or P3 had been set.
1- If you just set the time and day, go to step 2.
From Auto, Comfort, Eco or Frost protection mode, press
for 5 seconds.
When the cursor moves above the setting time symbol , press
shortly.
1
2
4- The cursor above the number 1 (which represents the Monday) will flash.
Select the day using
or
.
Save by pressing .
2- Press
or
. prog appears.
1
2
5- To change and/or allocate programmes press
mode, press
3 times.
. To exit the time and day
8
3- With
or , select P1.
P1 will flash. Press
for 5 seconds to make changes.
Version with occupancy detector:
The days of the week are all displayed. The default programme Auto appears on
the display.
1
2
5 sec.
4- The P1 start time (which by default is 06:00) will flash.
Using
or
, you can change this time, by increments of 30 minutes.
Press
or
.
The programme affected by default, Auto, flashes. It will be applied to all the days of the week.
1
2
Save by pressing .
5- The P1 end time (which by default is 22:00) will flash. Using can change
this time, by increments of 30 minutes.
Other version:
The days of the week will scroll on display with the programmes that you set
for them,
meaning Comfort (CoNF) every day.
or , you
Press
or
.
The programme set for day 1 (1= Monday, 2 = Tuesday, etc.) will flash.
1
2
Save by pressing .
6- Once all the days of the week are programmed, press the programming Mode and return to Auto Mode.
twice to exit
Note: without action on the keys, it will return to Auto after a few minutes.
Choices and allocation programmes
3- Chose the programme you want for this day with
or
.
Save by pressing .
1- If you just set the time and day, the cursor moves automatically under PROG.
From Auto, Comfort, Eco or Frost protection mode, then press
for 5 se-
conds. When the cursor positionned under the set time symbol , press
again.
Prior information: display area
Correspondence days /
numbers
Monday
1
Tuesday
2
Wednesday
3
Thursday
4
Friday
5
Saturday
6
Sunday
7
1
2
9
4- The programme assigned to the second day of the week (Tuesday) will flash.
Repeat the procedure described previously (in point 3) for each day of the
week.
OPEN WINDOW DETECTION
Important
The open window detection is sensitive to temperature variations. The device
will react to the window openings in accordance with different parameters: The
device will react to the window openings in accordance with different
parameters: temperature setting, rise and fall of temperature in the room,
outside temperature, location of the device… If the device is located close to
a front door, the detection may be disturbed by the air caused by opening
door. If this is a problem, we recommend that you disable the automatic mode
open window detection (see page 17). You can, however, use the manual
activation (see below).
5- Once you have chosen a programme for each day, confirm your selection by pressing . The days of the week will successively scroll on display with the programmes that you set for them (P1, P2, P3, CONF or ECO).
To exit the Programming mode, press
twice.
Viewing the programmes that you have selected
– From Auto, Comfort, Eco or Frost protection mode, press
for 5 seconds.
Press
twice, the programme for each day of the week (Comfort, Eco, P1, P2
or P3) will scroll on the display.
– To exit the programme viewing mode, press
twice.
Manual and temporary exemption from a running programme
This function allows you to change the setting temperature temporarily until
the next scheduled change in temperature or the transition to 00:00.
Example:
1 2
Legend = the favoured location = another location
2- By using the rotary dial, you can change temporarily the desired temperature up to 18°C for example.
Overview
Lowering temperature cycle by setting frost protection during ventilation of a
room by opened window. You can access the open window detection from the
Comfort, Eco and Auto modes. – Automatic activation, the lowering temperature
cycle starts as soon as the
device detects a temperature change.
Automatic activation (factory settings)
To disable this mode, see page 12. The device detects a temperature fall. An
opened window, a door to the outside, can cause this temperature fall.
Note: The difference between the air from the inside and the outside must
cause a significant temperature fall to be perceptible by the device. This
temperature drop detection triggers the change to Frost Protection mode.
Note: The cursor corresponding to the operating mode, i.e Eco mode in our
example, is blinking during the duration of the temporary derogation.
3- This change will be automatically cancelled at the next change of programme
or transition to 00:00.
Frost protection digital meter
When the device performs a lower temperature cycle due to opened window, a
meter appears on the display to show the cycle time. The counter is
automatically reset the next time Frost protection by opened window is
activated (automatic or manual activation).
Stop the Frost protection mode
By pressing any button, you stop the Frost protection mode.
Note: If a temperature rise is detected, the device may return to the previous
mode (active mode before the open window detection).
10
OCCUPANCY DETECTION, ENERGY SAVINGS
Important information about the occupancy detection
The occupancy detector is sensitive to temperature variations and light. It is
likely to be disturbed by the following items: – Hot or cold sources such as
forced air vents, lights, air conditioners. – Reflective surfaces such as
mirrors. – Animal crossing in the detection area. – Objects moving with the
wind like curtains and plants. Disable the occupancy detection if your device
was installed near one of these. To disable the occupancy detection, see page
16. Note: the detection range varies depending on the ambient temperature.
· Divisions of the detection zone
Top view
65°
65°
Active area Inactive area
Detection zone, for a temperature of 19°C. The detection zone is divided into active and inactive areas. A person that crosses the area will be detected by the infrared sensor.
Side view
Overview
The device fits your lifestyle while keeping your power consumption under
control. With its front infrared sensor, the device smartly optimizes the
management of heating : it detects movement in the room where it is installed
and in case of absence, automatically performs a progressive lowering of the
setting temperature resulting in: energy savings. To ensure proper operation,
do not block the sensor’s field of view by any obstacle (curtains,
furnitures…).
Lowering the temperature during unoccupied periods
Unoccupied periods*
20 minutes 40 minutes
1 hour 72 hours
Value of lowering setting temperature*
Comfort -1°C Comfort -1,5°C Comfort -2°C Frost protection
- Unchangeable factory settings
30°
INFORMATION ABOUT REMOTE CONTROL BY PILOT WIRE
Overview
Your device can be controlled by a central control unit through a pilot wire,
in which case the different operating modes will be remotely enabled by the
programmer. You can only control the device by pilot wire in the Auto mode. In
the other modes, the orders transmitted by the pilot wire will not be
executed. In general, a pilot wire control system makes it possible to impose
externally a lowering of the temperature setpoint, combined with the internal
programming and the occupancy detection. If several lowering requests appear
simultaneously, priority is given to the lowest temperature setpoint, thus
maximizing savings (see information on priorities for different modes on the
user guide of the concerned device). When a signal is sent from the pilot
wire, the self learning optimization function is suspended.
Note: when presence is detected in the room, the device automatically
returns to the initial mode.
Below the different views of the display for each order sent by pilot wire:
Remarks: By default, when the sensor is enabled and detects movement in the
room, the display lights up for a few seconds then switches off. To change the
backlight see page 13, backlight setting.
· Operation
Pilot wire = Comfort
Pilot wire = Eco Comfort – 3,5°C
Pilot wire = Eco – 1 Comfort – 1°C
Setting temperature
19°C 18°C 17,5°C 17°C
Pilot wire = Eco – 2 Comfort – 2°C
Pilot wire = Frost protection
Pilot wire = Stop (Standby mode)
7°C 19°C
18°C
17,5°C
-1°C
-1,5°C
20min. 40min. 60min.
Unoccupancy detected
17°C
7°C
-2°C
Pilot wire = Boost
Time
72hr
Load shedding
Occupancy detected
In case of over consumption, an energy power manager or a disconnector doesn’t trigger a trip of the general circuit-breaker (example: simultaneous operating of your various household appliances and others). This allows you to reduce the energy power subscribed and therefore optimize your subscription with your energy provider.
11
IMHOTEP creation controllers are designed to operate with pilot wire load shedding systems. Orders sent by the pilot wire are executed by the device’s electronic controller which will apply the setpoint corresponding to the order sent. The “Stop” order corresponds to the load shedding. When this order is received, the device switches to “standby” and then returns to the initial operating mode. Important: Do not use load shedding by a power fail. Unlike pilot shedding, this
INFORMATION ABOUT PRIORITIES BETWEEN THE DIFFERENT MODES
Principe
type of shedding results in a series of sudden and frequent power cuts, which cause premature wear of the device or even deterioration not covered by the manufacturer’s warranty.
In Comfort, Eco and Frost protection modes, only orders of the occupancy sensor and those of the open window sensor will be considered.
Exemption to an order coming from a pilot wire external programmer
This feature allows you to modify temporarily the setting temperature until
the next order sent by the central control unit or the transition to 00:00.
Example: 1- The device is in Auto mode. The central
control unit sent an Eco order 15,5°C.
2- By using the rotary dial, you can modify temporarily the setting
temperature up to 18°C for example.
In Auto mode, the device can receive different orders coming from : – 7 day
and daily programming integrated (Comfort or Eco orders); – 6-order pilot wire
if connected to central control unit; – Open window detector; – Occupancy
detector.
In general, it is the lowest received order which prevails except when the
pilot wire is connected to an energy management system, in this case the
orders of the pilot wire take priority. If an occupancy absence of more than
72 hours is detected, switching to frost protection takes precedence unless a
load shedding order is present on the pilot wire.
Special case of self-programming where the temperature level in the room is
decided according to the learning of the lifestyle and the optimization mode
selected (Opti Comfort or Opti Eco): – During the programmed passage in period
Eco, if a presence is detec-
ted in the room, it will be taken into account and the appliance automatically
switches to Comfort mode – During the programmed passage to the Comfort mode
period, the absence detection system is temporarily suspended (30 minutes).
In case of programmed Boost, the Boost activation will take precedence over
others orders received except when the standby (stop) order is present on the
pilot wire, the device will switch off and the Boost will be not activated.
Note: The cursor corresponding to the operating mode, i.e Eco mode in our
example, is blinking during the duration of the temporary derogation.
3- This modification will be automatically cancelled at the next order sent by
the central control unit or the transition to 00:00.
12
USER SETTINGS
ACCESS
Access to the User settings in 2 steps: From Auto, Comfort, Eco or Frost protection mode:
1- Press
for 5 seconds.
SETTING THE ECO MODE TEMPERATURE LOWERING-LEVEL
The drop in temperature is set at -3.5°C compared to the set temperature of the Comfort mode. You can adjust the lowered level from -1°C to -8°C, by intervals of 0.5°C. Important: whatever the lowering level set, the Eco setting temperature will never exceed 19°C.
1- Press
or
to obtain the temperature level you require.
5 sec.
2- Press
briefly twice.
2- Press
to save and move to the next setting.
2x
User = User settings is displayed
To exit the user settings, press
twice.
Setting sequence:
Eco mode temperature lowering-level
Frost protection temperature
Super comfort
Comfort setting temperature limits
Maximal Boost
duration Maximum ambient temperature Restoring factory settings
SETTING THE TEMPERATURE UNIT
The pre-set temperature unit is degrees Celsius.
16- Press
or
to change the temperature unit.
17- To save and move automatically to the next setting, press .
To exit the user settings, press
twice.
13
SETTING THE FROST PROTECTION TEMPERATURE
Your device is preset at 7°C. You can adjust the Frost protection temperature from 5°C to 15°C, by intevals of 0.5°C.
3- Press
or
to obtain the temperature you require.
6- To change the minimum temperature setting, press
or
then save by
pressing .
If you do not want to change it, press : the device changes automatically
to set the maximum setting. To exit the user settings, press
twice.
4- Press
to save and move to the next setting.
To exit the user settings, press
twice.
SUPER COMFORT (ONLY IF THE DEVIS IS A BLOWER) ACTIVATION/DEACTIVATION
By default, the Super comfort is enabled.
1
2
High temperature limit
Locking of the setting range using a maximum temperature increase, preventing
the temperature from being set above that temperature. The maximum setting is
preset to 30°C. You can adjust from 19°C to 30°C by intervals of 1°C.
7- To change the maximum temperature setting, press
or .
1
2
sCF appears, then yes flashes on the display. The Boost symbol and the heating
indicator appear on the display.
5- Press
or
to enable or disable the Super comfort.
To save and move to the next setting, press
press
twice.
. To exit the user settings,
SETTING OF THE MAXIMUM DURATION OF AUTHORISED BOOST
The maximum duration of Boost is preset at 60 minutes. You can adjust it from
30 to 90 minutes by intervals of 30 minutes.
8- The Boost symbol and the heating indicator appear on the display and the
preset duration of 60 minutes flash.
yes = Super Comfort enabled.
No = Super Comfort disabled.
To save and move to the next setting, press . To exit the user settings, press 9- Press
or
to display the desired duration.
twice.
COMFORT SETPOINT TEMPERATURE LIMIT
You can limit the setting temperature range by introducing a maximum and / or minimum setting, preventing unintentional changes in temperature.
Low temperature limit
Locking of the setting range using a minimum temperature stop, preventing the
temperature from being set below that temperature. The minimum setting is
preset to 7°C. You can adjust from 7°C to 15°C by intervals of 1°C.
1
2
14
10- To save and move to the next setting, press .
To exit the user settings, press
twice.
3- Press
for 5 seconds. The device returns to its initial configuration and
goes back automatically to the home display of the user settings.
SETTING OF THE MAXIMUM AMBIENT TEMPERATURE FOR THE AUTOMATIC STOP OF THE BOOST
When the Boost is enabled, the device has to heat the room until the
temperature limit: the maximum ambient temperature. When it is reached, the
Boost stops automatically. It is preset at 35°C, you can adjust it from 25°C
to 39°C by intervals of 1°C.
The Boost symbol and the heating indicator appear on the display and the
maximum temperature flashes.
11- You can set the Boost maximum temperature by pressing
or
from
25°C to 39°C by intervals of 1°C.
12- To save and move to the next setting, press
press
twice.
. To exit the user settings,
RESTORING FACTORY SETTINGS (ONLY IF PIN CODE IS DESABLED)
In order to return to the factory settings, proceed in the following order:
1- From the maximum ambient temperature setting, press on the display.
. rest appears
5 sec.
The following factory values will be effective:
Parameters
Factory settings
Operating
Comfort setting temperature
19°C
Boost duration
60 min.
Keypad lock
Disabled
User settings
Eco mode temperature lowering-level -3,5°C
Frost protection temperature
7°C
Super Comfort
Enabled
Minimum set of Comfort setting temperature
7°C
Maximum set of Comfort setting temperature
30°C
Maximal Boost duration
60 min.
Maximum ambient temperature for the automatic stop of the Boost
35°C
Press
to exit the user settings.
INSTALLER SETTINGS
ACCESS
To access the Installer settings in 3 steps: From Auto, Comfort, Eco or Frost protection mode :
1- Press
for 5 seconds.
2- No appears. Press
or
to select YES.
2- Press
5 sec. briefly twice.
yes = Factory settings reset. No = Factory settings not reset.
2x 15
User = User settings is displayed.
3- To save and move to the next setting, press
press
3 times.
. To exit the installer settings,
DUAL OPTIMIZATION FEATURE
This feature is available on the device equipped with occupancy detector.
3- Press
for 10 seconds.
= Installer settings is displayed
Press
briefly.
Setting sequence:
Configuration of detection modes lock Restoring factory settings
Dual optimization feature
PIN code
CONFIGURATION OF DETECTION MODES
Open window detection, activation/ deactivation of the Auto mode
The default setting of the automatic mode is enabled.
Overview
– Dual function optimization, priority to comfort or energy savings, the
choice is yours, depending on various parameters: room inertia, ambient
temperature, desired temperature, the device calculates and optimizes the
programming for each heating period whether set to Comfort or Savings (Eco): –
In OPTI ECO mode (efficiency priority), the device’s inbuilt algorithms will
calculate the best compromise in order to guarantee maximum energy savings
throughout the programmed increase and decrease phases. In this mode, a slight
drop in the temperature level at the beginning and end of the comfort period
is allowed to maximize energy savings. – In OPTI COMFORT mode (priority to
comfort), the device’s intelligence calculates the best compromise in order to
guarantee maximum comfort during the programmed increase and decrease phases.
In OPTI COMFORT mode, the priority is given to anticipating and maintaining
the comfort temperature during periods of detected occupancy.
Optimization choice
The OPTI COMFORT mode is activated by default.
The word OPTIwill appear briefly on the display then it will alternate with
the set mode CoNF, ECO or OFF.
1- Press
or
.
On = Automatic mode enabled.
OFF = Automatic mode disabled.
1- Press
or
.
2- To save and move to the next setting, press
press
3 times.
. To exit the installer settings,
Occupancy detection, activation/deactivation
1- The occupancy detection enabled is the default setting.
2- Press
or
.
ON = Occupancy detection enabled.
OFF = Occupancy detection disabled.
5 sec.
CONF = Optimisation feature activated for OPTI COMFORT mode, priority to
comfort.
ECO = Optimisation feature activated for OPTI ECO mode, priority to energy
efficiency.
OFF = Optimisation feature disactivated.
2- To save and move to the next setting, press
press
3 times.
. To exit the installer settings,
PIN CODE LOCK
Overview
Your heating device is protected by a safety code against nonauthorised use.
The PIN code (Personal Identity Number) is a customisable 4 numbers code. When
enabled, it prevents access to the following settings: – Selecting the Comfort
mode: The access to the Comfort mode is forbidden, only
the Auto, Eco and Frost protection modes are available. – Minimum and maximum
Limits of the setting temperature range (the Comfort
temperature modification is forbidden out of the authorised setting range). –
Programming mode. – Open window detection settings. – Setting the Eco mode
temperature lowering-level. – Setting the Frost protection temperature.
16
Version with occupacy detector, in addition: – Occupancy detection settings. –
Optimization choice.
3 important steps are needed for the first use of the PIN code lock: 1 – PIN
code initialisation, enter the preset PIN code (0000) to access the feature. 2
– Activation of the PIN Code to lock settings which will be protected by the
PIN
code. 3 – Customizing the PIN code, replace 0000 by the custmized code.
2- Press
PIN code initialisation
By default, the PIN code is not enabled.
1- OFF appears on the display.
to save and return to the home installer settings display.
By default registered PIN code is 0000.
Press
or
to select 0. Save by pressing
.
The PIN code is enabled. Any modification of reserved settings listed in
“Overview” is now impossible.
Customizing the PIN code
If you have just activated the PIN code, follow the steps described below.
Alternatively, you must copy the steps 1 and 2 of the initialisation process
as well as the steps 1 and 2 of the activation process before personalising
the PIN code. Please remember that the personalisation of the PIN code can
only be set once the initialisation and activation of the PIN code has been
completed.
1- When On appears, press
for at least 5 seconds.
1
2
2- For others numbers, select 0 by press .
When 0000 appears, press on
again to save and exit.
5 sec.
2- The 0000 code appears and the first number blinks. Press
or
to
select the first desired number then press
to save and exit. Repeat this
operation for the remaining 3 numbers.
The PIN code is initialized, the next setting appears: PIN Code activation.
Activation/deactivation of the PIN Code
1- OFF appears on the display.
Press
or
to enable PIN code.
ON appears on the display. ON = PIN code enabled OFF = PIN code disabled
3- Press
1
2
to confirm. The new code is now saved.
17
4- Press again on
to exit setting PIN code mode and go back to the home
display of the installer settings.
To exit the Installer settings, press
twice.
RESTORING FACTORY SETTINGS (ONLY IF PIN CODE IS DESABLED)
If the PIN code protection is disabled, the user and installer settings are re-initialized:
1- From the PIN code setting, press . rest appears briefly on the display.
The following factory values will be effective:
Settings
Factory settings
Operation
Comfort setting temperature
19°C
Boost duration
60 min.
Keypad lock
Disabled
User settings
Eco mode temperature lowering-level -3,5°C
Frost protection temperature
7°C
Super Comfort
Enabled
Minimum set of Comfort setting temperature
7°C
Maximum set of Comfort setting temperature
30°C
Maximal Boost duration
60 min.
Maximum ambient temperature for the automatic stop of the Boost
35°C
Installer settings
Automatic open window detection
Occupancy detection
Dual optimization feature
Enabled
Enabled Opti comfort
PIN code protection
Disabled
Value of the PIN code
0000
To exit the user settings, press
twice.
EXPERT SETTINGS
ACCESS
To access the expert settings in 4 steps. From Auto, Comfort, Eco or Frost protection mode :
1- Press
for 5 seconds.
2- No appears. Press
or
to select YES.
2- Press
5 sec. briefly twice.
yes = Factory settings reset.
No = Factory settings not reset.
3- Press the key
for 5 seconds. The device returns to its initial configuration
and goes back automatically to the home display of the installer settings.
2x
User = User settings is displayed.
5 sec. 18
3- Press
for 10 seconds.
InST = Instaler settings is displayed.
4- Press and hold
and
simultaneous for 10 seconds.
To correct, then proceed as follows: Sensor temperature= 21°C. (The measured
temperature may be different due to the location of the thermostat in the
room).
Increase the temperature measured by the ambient temperature sensor by 2°C by
pressing .
In our example the measured temperature by the sensor goes from 21°C to 23°C.
10 sec.
Setting sequence: Ambient temperature sensor adjustement
Restoring factory settings
AMBIENT TEMPERATURE SENSOR ADJUSTEMENT
Overview
Important: This operation is reserved for professional installers only; any
wrong changes would result in control anomalies. In which case if the
temperature measured (measured by reliable thermometer) is different by at
least 1°C or 2°C compared to the setting temperature of the radiator. The
calibration adjusts the temperature measured by the ambient temperature sensor
to compensate for a deviation from + 5°C to – 5°C by intervals of 0.1°C.
Ambient temperature sensor adjustement
1- If the ambient temperature difference is negative, example: Setting
temperature (what you want) = 20°C. Ambient temperature (what you read on a
reliable thermometer) = 18°C. Difference measured = -2°C.
Important: Before carrying out the calibration it is recommended to wait for
4h after the setting temperature modification to insure that the ambient
temperature is stabilized.
To correct, then proceed as follows: Sensor temperature = 24°C (The measured
temperature may be different due to the location of the thermostat in the
room).
To validate the new value press
. To exit the Expert settings, press
3
times.
Important: These changes should be performed by a qualified professional installer, they should be performed in production or on site during the first installation
RESTORING FACTORY SETTINGS (ONLY IF PIN CODE IS DESABLED)
If the PIN code protection is disabled, the user and installer settings are re-initialized:
1- From the PIN code setting, press . rest appears briefly on the display.
Decrease the temperature measured by the ambient temperature sensor by 2°C by
pressing .
In our example the measured temperature by the sensor goes from 24°C to 22°C.
2- No appears. Press
or
to select YES.
2- If the ambient temperature difference is positive, example:
Setting temperature (what you want) = 19°C. Ambient temperature (what you read
on a reliable thermometer) = 21°C. Difference measured = +2 °C.
yes = Factory settings reset. No = Factory settings not reset.
19
EN
3- Press the key
for 5 seconds. The device returns to its initial configuration
and goes back automatically to the home display of the installer settings.
The blower is equipped with a removable dust filter which retains impurities from the air aspirated into the room. When the filter is saturated, the dust accumulation may cause its stop.
In Boost mode, the writing FILT appears on the display.
5 sec.
The following factory values will be effective:
Settings
Factory settings
Operation
Comfort setting temperature
19°C
Boost duration
60 min.
Keypad lock
Disabled
User settings
Eco mode temperature lowering-level -3,5°C
Frost protection temperature
7°C
Super Comfort
Enabled
Minimum set of Comfort setting temperature
7°C
Maximum set of Comfort setting temperature
30°C
Maximal Boost duration
60 min.
Maximum ambient temperature for the automatic stop of the Boost
35°C
Installer settings
Automatic open window detection
Enabled
Occupancy detection
Enabled
Dual optimization feature
Opti comfort
PIN code protection
Disabled
Value of the PIN code
0000
Expert settings
Ambient temperature sensor adj.
0.0
To exit the expert settings, press
3 times.
MAINTENANCE AND CLEANING OF THE DUST FILTER
Before any action of filter removal, switch off the device by pressing the
button located under the blower. To clean the filter, proceed in the following
order: 1- Press the filter strip by the right or the left side then take it
out from its slot.
2- Use a vacuum cleaner to eliminate the dust deposited on the filter. If the
filter is very dirty, wash it under the water tap with a damp sponge. After
washing the filter, let it dry. Important : it is recommended to clean the
filter at least once a mon-
th unless the writing FILT appears on the display prematurely.
3- Once cleaned and dried, replace the filter in its slot by inserting it into
the runners.
Before any maintenance work, switch off the device by pressing the button
(switch).
The device can be cleaned with a damp cloth; never use abrasives or solvents.
TROUBLESHOOTING
Batteries are used or inadapted. – Replace the 2 batteries. Only use alkaline
1.5V LR6 batteries.
Do not use rechargeable batteries.
The heating does not come on or does not go off. – Your remote control may
have been set up close to a source of heat or on a cold
wall put it in a recommended location (see the “Installing” section on page
1 for these locations). – No power supply to the device: check the fuse and
the circuit breaker.
The ambient temperature is lower than the required temperature – Refer to the
device instruction manual.
Radio transmission is not working properly: 1- The device is not picking up
the code sent by the emitter.
– Replace transmitter’s batteries. 2- The device does not recognize
transmitter’s code.
– Pair the remote control transmitter with the device again (page 2). 3- The
device or the remote control is affected by interference:
– Move the remote control out of the affected area. – Try to move away the
device or the source of the interference
The super Comfort or Boost didn’t start: – Check the Super Comfort or Boost
duration (refer to the Boost duration section
page 4). – Check programming refer to the “Viewing programmes” section (see
page 8). – Check that the time and the day have been correctly set on your
programmable
remote control refer to the “Viewing day and time settings” section (see
page 6). – Check that the kind of application has been correctly set (see page
2).
Please refer to the troubleshooting section on instruction manual of your
device. If the problem persists, contact your installer.
TECHNICAL SPECIFICATIONS
Power supply: 2 alkaline 1.5 V LR6 batteries. Battery life: approx. 2 years.
Maximum range in the home: 15m typical but this varies depending on the
equipment being used in conjunction with the appliance (the appliance’s range
can be adversely affected by the way in which a system is set up and by the
surrounding electromagnetic environment. Signal sending: every 3 minutes,
maximum time-lag 1 minute after setpoint temperature has been changed. – Radio
frequency: 2,4035 Ghz/ 2,4055 Ghz / 2,4075 Ghz – Maximum RF power transmitted:
<1mW. Environment: – Operation temperature: from 0°C to +40°C. – Manual
temperature setting range: from +5°C to +30°C. – Storage temperature: from
-10°C to +60°C. – Humidity: 80% to +25°C (without condensation). – Protection
rating: IP30. Manufactured by: IMHOTEP création FRANCE
(contact@imhotepcreation.com)
RECYCLING AND COMPLIANCE DECLARATION
EU declaration of conformity: We hereby declare under our sole responsibility
that the products described in these instructions comply with the provisions
of Directives and harmonized standards listed below: – RED 2014/53/EU:
– Article 3.1a (Safety): EN62311:2008 – Article 3.1b (EMC): ETSI EN301489-1
V2.1.0 (2016)/ ETSI EN301489-3 V2.1.0
(2016) – Article 3.2 (RF): ETSI EN 300440 V2.1.1 (2016) – ERP 2009/125/EC –
Regulation 2015/1188/EU – ROHS 2011/65/EU: EN50581 and are manufactured using
processes which are certified ISO 9001 V2008.
The on the product indicates that you must dispose of it at the end of its
useful life at a special recycling point, in accordance with European
Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to
the retailer from which you buy the replacement equipment. Thus, it is not
ordinary household waste. Recycling products enables us to protect the
environment and to use less natural resources.
EN