Product Information
The CX41 is a budget-friendly and ultra-portable Time Domain eflectometer (TDR) designed specifically for the Outside Plant. It is primarily used in telecommunications applications.
Key Features:
- Telco Version: This version of the CX41 is specifically tailored for telecommunication purposes.
Specifications:
Unfortunately, the user manual does not provide specific details regarding the specifications of the CX41. We recommend referring tothe product datasheet or contacting the manufacturer for more information on its technical specifications.
Product Usage Instructions
Follow these steps to use the CX41 Time Domain Reflectometer:
- Ensure that the CX41 is fully charged or connected to a power source, depending on its power requirements.
- If available, connect the appropriate cables or adapters to the CX41 and the device or system you want to test.
- Power on the CX41 by pressing the designated power button or switch.
- Once powered on, familiarize yourself with the user interfaceand controls of the CX41. Refer to the user manual or quick start guide for detailed instructions on navigating the interface.
- Configure the necessary settings such as pulse width,measurement range, and display options according to your specific testing requirements. Consult the user manual for guidance on how to access and adjust these settings.
- Position the CX41 at the starting point of the cable or network segment you wish to test.
- Initiate the measurement by pressing the appropriate button ortrigger. The CX41 will emit a pulse and analyze the reflected signal to determine cable faults, impedance mismatches, or other anomalies.
- Observe the results displayed on the CX41’s screen orinterface. Interpret the readings and analyze any detected issues based on the provided documentation or industry standards.
- Repeat the process by moving the CX41 along the cable or network segment, testing different sections as required.
- Once testing is complete, power off the CX41 and disconnect any cables or adapters.
- Properly store the CX41 in a safe and dry location to ensure its longevity and protect it from damage.
Note: For detailed instructions on using specific features, advanced settings, or troubleshooting, please refer to the comprehensive user manual provided with the CX41 Time Domain Reflectometer.
The CX41 is a budget friendly and ultra portable Time Domain Reflectometer suitable for the Outside Plant.
Key Features
- Fault identification and location
- Cable length verification
- One touch automatic mode for a quick test
- Manual mode for detailed TDR trace analysis
- DC voltage measurement for line power verification*
- AC voltage measurement for induced foreign voltage detection*
- Simple user interface that saves time on the job
Specifications
- Telco Version:
- Test Port: 2 mm banana
- Range: 3.6 km (12 kft)
- Coaxial Version:
- Test Port: F or BNC
- Range: 1.5 km (5 kft)
- Accuracy: 1% of selected range or 1m (3 ft)
- Minimum resolution: 0.025m (0.08 ft)
- Velocity factor: Adjustable to 99%
- Pulse width: 10 ns to 10 μs (automatic with range)
- Impedance: 50, 75, 100, 120 ohms
- DC voltage range: 300V*
- AC voltage range: 200V*
- Dimensions: 129 x 61 x 39 mm (5.1 x 2.4 x 1.5 in)
- Weight: <450 grams (<1 pound)
- Battery options: Standard alkaline AA or optional rechargeable NiMH
© 2020 VeEX Inc. All rights reserved.
VeEX is a registered trademark of VeEX Inc. The information contained in this
document is accurate. However, we reserve the right to change any contentsat
any time without notice. We accept no responsibility for any errors or
omissions. In case of discrepancy, the web version takes precedence over any
printed literature.
D05-00-185P A00 2020/11
VeEX Inc.
- 2827 Lakeview Court
- Fremont, CA 94538 USA
- Tel: +1.510.651.0500
- Fax: +1.510.651.0505
- www.veexinc.com