Westinghouse WGen12000DFc Dual Fuel Portable Generator User Manual
- June 4, 2024
- Westinghouse
Table of Contents
USER MANUAL
WGen12000DFc
Dual Fuel Portable Generator
Gasoline: 12,000 Running Watts | 15,000 Peak Watts
Propane: 10,800 Running Watts | 13,500 Peak Watts
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call the customer
service at 855-944-3571.
WGen12000DFc Dual Fuel Portable Generator
WARNING: Operating, servicing, and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. To minimize exposure, avoid breathing exhaust, and wear gloves or wash your hands frequently when servicing this equipment. For more information go to www.P65warnings.ca.gov.
DISCLAIMERS
All information, illustrations, and specifications in this manual were in
effect at the time of publishing. The illustrations used in this manual are
intended as representative reference views only. We reserve the right to make
any specification or design change without notice.
ALL RIGHTS RESERVED
All rights reserved. No reproduction is allowed in any form without written
permission from Westinghouse Outdoor Power Equipment.
to make any specification or design change without notice.
DANGER
Read this manual before using or performing maintenance on this product. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death.
SAVE THESE INSTRUCTIONS
INTRODUCTION
SPECIFICATIONS
Running Watts: | 12.000 Gas / 10.800 LPG |
---|---|
Peak Watts: | 15.000 Gas / 13.500 LPG |
Rated Voltage: | 120/240V |
Rated frequency: | 60 Hz @ 3600 RPM |
Phase: | Single phase |
Total Harmonic Distortion: | 55% |
Engine Displacement: | 713 cc |
Starting Type: | Recoil. Electric Start. Remote |
Fuel Capacity: | 10.5 Gallons (40 Liters) |
Fuel Type: | •Unleaded gasoline 87-93 octane’ |
•HD-5 Propane
Oil Capacity:| 1.7 US Quart (1.6 Liter)
Oil Type:| SAE 10W-30
Spark Plug:| 97110 (5357)
Spark Plug Gap:| 0.024 — 0.032 in. (0.60 — 0.80 mm)
Valve Intake Clearance:| 0.0031 — 0.0047 in. (0.08 — 0.12 mm)
Valve Exhaust Clearance:| 0.0051 — 0.0067 in. (0.13 — 0.17 mm)
Battery:| 511092
AC Grounding System:| Bonded to frame
Voltage Regulator:| AVR
Alternator Type:| Brushed
Maximum Ambient Temperature:| 104°F (40°C)
Certifications:| •EPA
•GARB
*Ethanol content of 10% or less. DO NOT use E15 or E85.
UPDATES
The latest User Manual for your Westinghouse generator can be found under our
support tab. https://westinghouseoutdoorpower.com/pages/manuals
Or scan the following QR code with your smartphone camera to be directed to
the link.
https://westinghouseoutdoorpower.com/pages/manuals
NOTICE
This product is designed and rated for continuous operation at ambient
temperatures up to 104°F (40°C). If needed, this product can be operated at
temperatures ranging from 5°F (-15°C)–122°F (50°C) for short periods. If the
product is exposed to temperatures outside of this range during storage, it
should be brought back within this range before operation. This product must
always be operated outdoors in a well-ventilated area and far away from doors,
windows, and other vents. Maximum wattage and current are subject to and
limited by such factors as fuel BTU content, ambient temperature, altitude,
engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet
above sea level, and will also decrease about 1% for each 10°F (6°C) above
60°F (16°C) ambient temperature.
PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to register your
Westinghouse generator. You can register by:
- Completing and mailing the product registration card included in the carton.
- Registering your product online at: https://westinghouseoutdoorpower.com/pages/warranty-registration
- Scan the following QR code with your smartphone camera to be directed to the mobile registration link.
https://westinghouseoutdoorpower.com/pages/warranty-registration
- Sending the following product information to: Westinghouse Outdoor Power Warranty Registration
777 Manor Park Drive Columbus, OH 43228
For Your Records
Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:
IMPORTANT: Keep your purchase receipt for trouble-free warranty coverage.
SAFETY
SAFETY DEFINITIONS
The words DANGER, WARNING, CAUTION, and
NOTICE are used throughout this manual to highlight important
information. Make sure that the meaning of this safety information is known to
all who operate, perform maintenance on, or are near the generator.
This safety alert symbol appears with most safety statements. It means
attention, be alert, and your safety is involved! Please read and abide by the
message that follows the safety alerts symbol.
DANGER Indicates a hazardous situation that, if not avoided, will result
in death or serious injury.
WARNING Indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
CAUTION Indicates a hazardous situation that, if not avoided, could
result in minor or moderate injury.
NOTICE
Indicates a situation that can cause damage to the generator, personal
property, and/or the environment, or cause the equipment to operate
improperly.
Note: Indicates a procedure, practice or condition that should be followed for the generator to function in the manner intended.
SAFETY SYMBOLS
Follow all safety information contained in this manual and on the generator.
Symbol | Description |
---|---|
Safety Alert Symbol | |
Electrocution Hazard | |
Asphyxiation Hazard | |
Burn Hazard. Do not touch hot surfaces. | |
Electrical Shock Hazard | |
**** | Fire Hazard |
Maintain Safe Distance | |
Lifting Hazard | |
Read the Manufacturer’s Instructions | |
Do Not Operate in Wet Conditions |
SAFETY INSTRUCTIONS
CORRECT USE
Example location to reduce risk of carbon monoxide poisoning ONLY use outside
and downwind, far away from windows, doors and vents. Direct exhaust away from
occupied spaces
INCORRECT USE
Do not operate in any of the following locations: Near any door, window, or
vent
- Garage
- Basement
- Crawl Space
- Living Area
- Attic
- Entry Way
- Porch
- Mudroom
NOTICE
Install battery-powered carbon monoxide detectors or plug-in carbon monoxide
detectors with battery backup in living areas.
DANGER
Fire and electrocution hazard. Do not connect to a building’s electrical
system unless the generator and transfer switch have been properly installed
and the electrical output has been verified by a qualified electrician. The
connection must isolate the generator power from the utility power and must
comply with all applicable laws and electrical codes.
DANGER
Electrocution hazard. Never use the generator in a location that is wet or
damp. Never expose the generator to rain, snow, water spray, or standing water
while in use. Protect the generator from all hazardous weather conditions.
Moisture or ice can cause a short circuit or other malfunction in the
electrical circuit.
GENERAL SAFETY PRECAUTIONS
- Never use the generator to power medical support equipment.
- DO NOT operate the generator when you are tired or under the influence of drugs, alcohol, or medication.
- When this generator is used to supply a building wiring system the generator must be installed by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70, National Electrical Code.
- Only use OUTSIDE and far away from windows, doors, and vents as recommended by the US Department of Health and Human Services Centers for Disease Control and Prevention. Your specific home and/or wind conditions may require additional distance.
- If you begin to feel sick, dizzy, or weak while using the generator, move to fresh air IMMEDIATELY. See a doctor, as you can have carbon monoxide poisoning.
- While operating and storing, keep at least five feet of clearance on all sides of the generator, including overhead. Allow the generator to cool a minimum of 30 minutes before storage. The heat created by the muffler and exhaust gases could be hot enough to cause serious burns and/or ignite combustible objects.
- DO NOT use a generator with electrical cords which are worn, frayed, bare, or otherwise damaged.
- All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or be double-insulated.
- DO NOT touch the muffler or engine. They are very HOT and will cause severe burns. Do not put body parts or any flammable or combustible materials in the direct path of the exhaust.
- ALWAYS remove any tools or other service equipment used during maintenance from the generator before operating.
- Avoid skin contact with engine oil or gasoline. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
FUEL SAFETY
- Store fuel in a container approved for gasoline.
- Do not smoke when filling the generator with gasoline.
- Wear eye protection while refueling.
- Never remove the fuel cap when the generator is running. Shut off the engine and allow the unit to cool at least five minutes. Remove the fuel cap slowly to release pressure, keep fuel from escaping around the cap, and to avoid the heat from the muffler igniting fuel vapors. Tighten the fuel cap securely after refueling.
- Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces.
- Spilled fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose of rag properly. Allow the area of spilled fuel to dry before operating the generator.
- Store any containers containing gasoline in a well-ventilated area, away from any combustibles or source of ignition.
GASOLINE AND GASOLINE VAPOR
DANGER
Fire and explosion hazards. Gasoline is highly explosive and flammable and
can cause severe burns or death.
- Gasoline is highly flammable and explosive.
- Gasoline can cause a fire or explosion if ignited.
- Gasoline is a skin irritant and needs to be cleaned up immediately if it comes in contact with the skin.
- Gasoline has a distinctive odor, this will help detect potential leaks quickly.
- In any petroleum gas fire, flames should not be extinguished unless by doing so the fuel supply valve can be turned OFF. This is because if a fire is extinguished and a supply of fuel is not turned OFF, then an explosion hazard could be created.
- Gasoline expands or contracts with ambient temperatures. Never fill the gasoline tank to full capacity, as gasoline needs room to expand if temperatures rise.
LIQUID PETROLEUM GAS (LPG/PROPANE)
WARNING
Fire and explosion hazards. Never use a gas container, LPG/propane connector
hose, LPG/propane tank or any other fuel item that appears to be damaged.
CAUTION
Fire and explosion hazards. Only use approved LPG/ propane tanks with an
Overfilling Prevention Device (OPD) valve. Always keep the tank in a vertical
position with the valve on top and placed at ground level on a flat surface.
Do not allow tanks to be near any heat source. When transporting and storing,
turn the propane tank valve to the fully closed position and disconnect the
tank. Make sure to always cover the generator inlet and tank outlet with
protective plastic caps.
- LPG/Propane is highly flammable and explosive.
- Flammable gas under pressure can cause a fire or explosion if ignited.
- LPG/Propane can settle in low places because it is heavier than air.
- LPG/Propane has a distinctive odor added to help detect potential leaks.
- Always keep an LPG/Propane tank in an upright position.
- When exchanging LPG/propane tanks, be sure the tank valve is the same type.
- In case of an LPG/propane fire, do not attempt to extinguish it unless the fuel supply can be shut off safely.
- LPG/propane will burn the skin. Prevent skin contact at all times.
- Keep the propane tank away from the generator exhaust.
- A step-down regulator is required when using LPG/ propane tanks over 100 gallons. The pressure as measured at the regulator mounted to the generator must be 7” to 14” of the water column.
- Large (500–1000 gallon) LPG/propane tanks will require a certified plumber to install the fuel line to the generator and the loose regulator is not used (the regulator that is attached to the fuel tank). The pressure as measured at the regulator mounted to the generator must be 7” to 14” of the water column. A certified plumber must ensure that the pressure is correct or install a step-down regulator if needed.
WARNING
Fire and explosion hazard. If there is a strong smell of propane while
operating the generator, fully close the LPG/propane tank valve immediately.
Once the propane is off, use soapy water to check for leaks on the hose and
connections on the tank valve and the generator. Do not smoke or light a
cigarette or check for leaks using any open flame source such as a match or
lighter. If a leak is found, contact a qualified technician to inspect and
repair the LPG/propane system before using the generator.
When starting the generator:
- Make sure that the fuel cap, air filter, spark plug, fuel lines, and exhaust system are properly in place.
- If you spill any gasoline on the tank, allow it to fully evaporate before operating.
- Make sure the generator and LPG/propane tank are on a flat surface before operating.
- If there is a propane odor do not start the unit because there may be a potential leak. Never place an LPG/ propane tank near the engine exhaust.
When transporting or servicing the generator:
- Make sure the LPG/propane tank and LPG/propane hose are not attached to the generator.
- Disconnect the spark boot to prevent accidental starting.
When storing the generator :
- Store away from sparks, open flames, pilot lights, heat, and other sources of ignition.
- Do not store gas or an LPG/propane tank near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
SAFETY LABELS AND DECALS
CO SENSOR
The carbon monoxide (CO) sensor monitors for the accumulation of poisonous
carbon monoxide gas around the generator when the engine is running. If unsafe
levels of CO gas are detected, the CO Sensor automatically shuts down the
engine. The CO Sensor will also detect the accumulation of carbon monoxide
from other fuel-burning sources used in the area of operation. For example, if
the exhaust of fuel-burning tools is pointed at a CO Sensor-equipped
generator, a shut-off may be initiated due to unsafe CO levels. This is not an
error. Hazardous carbon monoxide has been detected. Move and redirect any
additional fuel-burning sources to dissipate carbon monoxide away from
personnel and occupied buildings.
Note: Remote start-equipped generators must be restarted with the START/STOP button on the control panel after an automatic shutdown occurs.
Generators are intended to be used outdoors, far from occupied buildings and the exhaust is pointed away from personnel and buildings. If misused and operated in a location that results in the accumulation of CO, like in a partially enclosed area, the CO Sensor shuts off the engine. A RED indicator light will indicate the unit was shut down due to an unsafe level of CO being detected around the generator. Before approaching the generator allow the CO to dissipate from around the generator. The CO Sensor DOES NOT replace carbon monoxide alarms. Install battery-powered carbon monoxide alarm(s) in your home.
WARNING
Automatic shutoff accompanied by a flashing RED light in the CO Sensor portion
of the control panel is an indication that the generator was improperly
located. If you start to feel sick, dizzy, weak, or carbon monoxide detectors
in your home indicate an alarm, get to fresh air immediately. Call emergency
services. You may have carbon monoxide poisoning.
CONTROL PANEL CO AUTO-SHUTOFF
CO SENSOR INDICATOR LIGHTS
Color | Description |
---|---|
RED | Unsafe levels of carbon monoxide accumulated around the generator. After |
shut-off, the RED indicator light in the CO Sensor area of the control panel
will flash to provide a notification that the generator was shut off due to an
accumulation of unsafe CO levels. The RED light will flash for at least five
minutes after a CO shut-off.
Move the generator to an open, outdoor area far away from occupied spaces with
exhaust pointed away. Once relocated to a safe area and the red light is off,
the generator can be restarted. Introduce fresh air and ventilate the area
where the generator had shut down.
YELLOW| A CO sensor system fault occurred. When a system fault occurs, the
generator is automatically shut down and the YELLOW indicator light in the CO
auto-shutoff area of the control panel will flash to provide a notification
that a fault has occurred. The YELLOW light will flash for at least five
minutes after a fault. The generator can be restarted but may continue to shut
off. A CO sensor fault can only be diagnosed and repaired by an authorized
Westinghouse service center.
ACTION LABEL
COMPONENTS
COMPONENTS
GENERATOR COMPONENTS
CONTROL PANEL COMPONENTS
- Push-Button START/STOP: Push once to automatically start the engine. Push again to stop the engine.
- Battery Indicator: Indicates that power is ON. Light will remain illuminated while the unit is ON.
- Battery Switch : Turns battery ON and OFF. Must be ON before electricity or remote starts.
- Low Idle: Low Idle minimizes fuel consumption, noise, and engine wear by lowering the engine RPM during intermittent use. See the LOW IDLE section for important use considerations.
- Fuel Selector Switch: Used to select gas or propane operation.
- USB Ports: Two-port 5V/2.1A USB outlet. Accepts Type A USB plugs.
- Data Center: Displays voltage, frequency, total hour meter, and run/maintenance timer.
- Main Circuit Breaker: The main circuit breaker controls the total output of all outlets to protect the generator from overload or short circuits.
- Smart Switch Outlet: Connects the Westinghouse ST Switch (sold separately) to the control panel.
- Battery Charging Port: Used to charge the battery with the included battery charger.
- Ground Terminal: The ground terminal is used to externally ground the generator.
- 120/240-Volt AC, 50-Amp NEMA 14-50R Receptacle : The receptacle can supply either 120V or 240V up to 50 amps.
- 30 Amp AC Circuit Breaker: The circuit breaker limits the current that can be delivered through the NEMA L14-30R receptacle to 30 amps.
- 120/240-Volt AC, 30-Amp NEMA L14-30R Receptacle: The receptacle can supply either 120V or 240V up to 30 amps.
- 30 Amp AC Circuit Breaker: The circuit breaker limits the current that can be delivered through the NEMA L5-30R receptacle to 30 amps.
- 120-Volt AC, 30-Amp NEMA L5-30R Receptacle: The receptacle can supply a maximum of 30 Amps.
- 20 Amp AC Circuit Breakers: Circuit breakers limit the current that can be delivered through each NEMA 5-20R receptacle to 20 Amps.
- 120-Volt AC, 20-Amp NEMA 5-20R GFCI Receptacles: Each receptacle is capable of carrying a maximum of 20 amps on a single receptacle or a combination of both receptacles.
- CO Sensor indicator lights: The CO Sensor monitors for the accumulation of poisonous carbon monoxide gas. If increasing levels of CO gas are detected, the CO Sensor automatically shuts down the engine.
DATA CENTER
Use the Mode button on the Data Center to switch between displays.
MAINTENANCE REMINDERS
Maintenance reminder codes will be shown on the Data Display based on unit
lifetime hours. The maintenance codes will be displayed until the unit is
turned off. Refer to the Maintenance section for specific procedures.
Maintenance Code | Required Maintenance |
---|---|
P25 | Change engine oil |
P50 | Change engine oil, clean air filter |
P100 | Change engine oil, clean air filter, replace the fuel filter |
ASSEMBLY
ASSEMBLY
This unit ships fully assembled from our factory without oil in the engine. It
must be properly serviced with fuel and oil before operation.
If you have any questions regarding preparing your generator for the initial
start, contact our service team at
service@wpowereq.com or call
1-855-944-3571.
UNPACKING
CAUTION
Weight hazard. Always have assistance when lifting the generator.
- Place the shipping carton on a solid, flat surface and carefully open the carton.
- Remove and save the carton contents.
- Remove and discard the packing tray.
- Unfold the top of the plastic bag enclosing the generator.
- Carefully cut the vertical corners of the carton to access the generator.
- Recycle or dispose of the packaging materials properly.
CARTON CONTENTS
- Generator
- User manual
- Quick Start Guide/Maintenance Schedule
- LPG/propane hose with regulator
- Remote start key fob
- 1.7 US Quart (1.6 Liter) bottle of SAE 10W-30 Oil
- Battery charger
- Spark plug socket wrench
- Oil Funnel
- Assembly wrench
- Wheel and lifting hook components
Item | Quantity |
---|---|
• Lifting hook | 1 |
• Flange bolt, M8 | 4 |
• Wheel | 2 |
• Axle pin | 2 |
• Washer | 4 |
• Cotter pin | 4 |
If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571.
INSTALL WHEELS AND LIFTING BRACKET
NOTICE
Assembling the generator will require lifting the unit on one side. Install
the wheels before adding fuel or oil.
CAUTION
Lifting hazard. Use two people when installing the wheels. Refer to LIFTING
HOOK in the OPERATION section.
-
Place the generator on a flat surface.
-
Align the lifting hook bracket with the mounting brackets on the top of the fuel tank. Secure with four M8 flange bolts.
-
Use the Lifting Hook to raise the unit enough to install the wheels as shown.
Note: The wheels are only intended for hand transport. The wheels are not suitable for towing the generator either on or off-road.
INITIAL OIL FILL
NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT OIL. Do not attempt to crank or start
the engine before it has been properly serviced with recommended oil. Failure
to add engine oil before starting will result in serious engine damage.
NOTICE
Use of 2-stroke/cycle oil or other unapproved oil types can cause severe
engine damage that is not covered under warranty.
The included, recommended oil type for typical use is 10W-30 engine oil. If
running the generator in extreme temperatures, refer to the following chart.
-
On a level surface, remove the oil fill cap.
-
Using the supplied funnel and oil, add the oil to the engine.
-
Replace the oil fill cap and tighten it securely.
BATTERY INSTALLATION
CAUTION
Battery posts, and terminals contain lead and lead compounds. Wash hands after
handling.
WARNING
The battery gives off explosive hydrogen gas during normal operation. A
spark or flame can cause the battery to explode with enough force to kill or
seriously hurt you. Wear protective clothing and a face shield, or have a
skilled technician perform battery maintenance.
WARNING
Burn hazard. The battery contains sulfuric acid (electrolyte) which is highly
corrosive and poisonous. Wear protective clothing and eye protection when
working near the battery. Keep children away from the battery.
WARNING
NEVER smoke or work near sparks or other sources of ignition. NEVER touch both
battery terminals at the same time with your hand or any non-insulated tools.
If battery acid contacts skin or clothing, flush immediately with water and
neutralize with baking soda. The battery shipped with the generator has been
fully charged. A battery may lose some charge when not in use. See the BATTERY
MAINTENANCE section for the battery charging procedure.
Note: Once started, the generator will charge the battery after 30–60
minutes of use.
-
Remove the two battery plate bolts and battery plate. Tilt the battery forward and remove it.
-
Connect the positive (+) battery cable (red boot) to the positive (+) battery post. Secure the boot over the battery post.
-
Connect the negative (-) cable (black boot) to the negative (-) battery post. Secure the boot over the battery post.
-
Install the battery in the battery tray. Install the battery plate and bolts. Tighten the bolts securely.
FUEL
WARNING
Fire and explosion hazards. Never use a gasoline container, gasoline tank,
propane connector hose, propane tank, or any other fuel item that is broken,
cut, torn or damaged.
DANGER
Fire and explosion hazards. Do not overfill the fuel tank. Fill only to the
red fill ring located in the in-tank fuel screen filter. Overfilling may cause
fuel to spill onto the engine causing a fire or explosion hazard.
DANGER
Fire and explosion hazards. Never refuel the generator while the engine is
running. Always turn the engine off and allow the generator to cool for two
minutes before refueling.
NOTICE
| Do not use E15 or E85 fuel in this product. Engine or equipment damage
caused by stale fuel or the use of unapproved fuels (such as E15 or E85
ethanol blends) is not covered by warranty. Only use unleaded gasoline
containing up to 10% ethanol.
---|---
FUEL REQUIREMENTS
- CLEAN, FRESH, unleaded gasoline, 87–93 octane.
- Up to 10% ethanol (gasohol) is acceptable (where available; non-ethanol fuel is recommended).
- DO NOT use E85 or E15.
- DO NOT use a gas oil mix.
- DO NOT modify the engine to run on alternate fuels.
- DO NOT fuel indoors.
- DO NOT create a spark or flame while fueling.
USING FUEL STABILIZER
Adding a fuel stabilizer (not included) extends the usable life of fuel and
helps prevent deposits from forming that can clog the fuel system. Follow the
manufacturer’s instructions for use.
Always mix the correct amount of fuel stabilizer to gasoline in an approved
gasoline container before fueling the generator. Run the generator for five
minutes to allow the stabilizer to treat the entire fuel system.
FILLING THE FUEL TANK
-
Turn the generator OFF and allow it to cool for a minimum of two minutes before fueling.
-
Place the generator on level ground in a well-ventilated area.
-
Clean the area around the fuel cap and remove the cap slowly.
NOTICE
Only fill the tank from an approved gasoline container. Make sure the gasoline container is internally clean and in good condition to prevent fuel system contamination. -
Slowly add the recommended fuel. Do not overfill. Fill only to the red maximum fill ring on the fuel screen filter visible in the filler neck.
-
Install the fuel cap.
NOTICE
Fuel can damage paint and plastic. Use caution when filling the fuel tank.
Damage caused by spilled fuel is not covered under warranty.
NOTICE
Clean the fuel screen filter of the debris before and after each fueling.
Remove the fuel screen filter by slightly compressing it while removing it
from the fuel tank.
CONNECT AN LPG/PROPANE TANK
NOTICE
- The LPG/propane tank can be of any capacity but the tank must conform to the standard as listed in Fuel Safety section.
- Propane tanks that use a liquid withdrawal system can not be used on these models.
- Verify the re-qualification date on the tank has not expired.
- Do not use included LPG/propane hose for any other appliances.
NOTICE
- All new tanks must be purged of air and moisture prior to filling. Used tanks that have not been plugged or kept closed must also be purged. The purging process should be done by a propane supplier (Tanks from an exchange supplier should have been purged and filled properly).
- Always position the tank so the connection between the valve and the gas inlet will not cause sharp bends or kinks in the hose.
WARNING
Explosion hazard. Do not start the generator if you smell LPG. Always fully
close the propane tank valve and disconnect the LPG/propane hose from the
generator when not in use.
-
Turn the generator OFF and place it on a flat surface in a well-ventilated area.
-
Verify that the propane tank valve is in the fully closed position.
-
Remove the cover on the generator propane inlet valve.
-
Use your fingers to hand thread the LPG/propane hose (included) to the propane inlet on the generator.
IMPORTANT: DO NOT use thread seal tape or any other type of sealant to seal the LPG/propane hose connection. -
Tighten the LPG/propane hose connector to the generator with a 19 mm or adjustable wrench. DO NOT over-tighten.
Torque: 5-10 lb-ft. -
Remove the safety plug or cap from the propane tank valve and attach the other end of the hose to the LPG/ propane connector on the tank. Hand tightens.
-
Turn the propane tank valve to the fully open position. Check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles that appear or bubbles that grow indicate that a leak exists. If a leak exists at a fitting, turn the propane tank valve to the fully closed position and tighten the fitting. Open the propane tank valve and recheck the fitting with the soap and water solution. If the leak continues or if the leak is not at a fitting then do not use the generator and contact customer service.
IMPORTANT: Keep the propane tank valve in the fully closed position unless in use.
GROUNDING
WARNING
Shock hazard. Failure to properly ground the generator can result in electric
shock.
NOTICE
Only use grounded extension cords, tools, and appliances, or double-insulated
tools and appliances.
The generator neutral is bonded to the frame. There is a permanent conductor
between the generator (stator wire) and the frame. If this generator will be
used only with cord
and plug equipment connected to the receptacles mounted on the generator,
National Electric Code does not require that the unit be grounded. However,
other methods of using the generator may require grounding to reduce the risk
of shock or electrocution. Before using the ground terminal, consult a
qualified electrician, electrical inspector, or local agency having
jurisdiction for local codes or ordinances that apply to the intended use of
the generator.
DISCONNECTING THE BONDED NEUTRAL
Removing the bonded neutral disables the GFCI protection from the 5-20R
receptacles. The bonded neutral should only be removed under specific
circumstances. Consult a qualified electrician to determine if your situation
requires disconnecting the bonded neutral.
-
Remove the alternator cover.
-
Remove the bonded jumper wire and reinstall the nut.
-
Remove the nut securing the neutral ground wire and attach the bonded jumper wire. Reinstall the nut.
-
Reinstall the alternator cover.
IMPORTANT: Apply a new “NEUTRAL UNBONDED”
Label over the “NEUTRAL BONDED TO FRAME” label on the front of the control panel.
OPERATION
OPERATION
GENERATOR LOCATION
Read and understand all safety information before starting the generator.
NEVER operate the generator inside any building, including garages, basements,
crawlspaces, sheds, enclosures, or compartments, including the generator
compartment of a
recreational vehicle.
DANGER
Electrocution hazard. Never use the generator in a location that is wet or
damp. Never expose the generator to rain, snow, water spray, or standing water
while in use. Protect the generator from all hazardous weather conditions.
Moisture or ice can cause a short circuit or other malfunction in the
electrical circuit. Using a generator or electrical appliance in wet
conditions, such as rain or snow, or near a pool or sprinkler system, or when
your hands are wet, could result in electrocution
WARNING
Fire hazard. Only operate the generator on a solid, level surface. Operating
the generator on a surface with loose material such as sand or grass clippings
can cause debris to be ingested by the generator that could block cooling
vents or the air intake system. Allow the generator to cool for 30 minutes
before transport or storage.
The generator should be on a flat, level surface at all times (Even while not
in operation). The generator must have at least 5 ft. (1.5 m) of clearance
from all combustible material.
Do not operate the generator in the back of an SUV, camper, trailer, truck bed
(regular, flat, or otherwise), under stairs, next to walls or buildings, or in
any other location that will not allow for adequate cooling of the generator
and/or the muffler. DO NOT contain generators during operation.
DANGER
Asphyxiation hazard. Place the generator in a well-ventilated area. DO NOT
place the generator near vents or intakes where exhaust fumes could be drawn
into occupied or confined spaces. Carefully consider wind and air currents
when positioning the generator.
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea level. The output
will be reduced by approximately 3.5% for every 1000 feet of increased
altitude from sea level.
High altitude adjustment is required for operation at altitudes over 2,000 ft.
(762 m). Operation without this adjustment will cause decreased performance,
increased fuel consumption, and increased emissions.
NOTICE
Do not operate the generator at altitudes below 2,000 ft. (762 m) with the
high-altitude kit installed. Engine damage may occur.
High Altitude Carburetor Kit Part# 518904
REMOTE START
WARNING
Verify that the area around the generator is clear before remote starting the
generator.
The remote start key fob included with the generator should be attached to the
recoil handle or control panel. If your unit was shipped without a key fob,
contact Westinghouse
customer service. The generator can be started remotely from up to 99 feet
(30 meters) using the remote start key fob.
Note: As the batteries in the remote start key fob drain, operational
distance will decrease.
PAIRING THE REMOTE START
Remote replacement batteries: (2) CR2016
If the remote start key fob is replaced or needs re-paired to the generator,
follow this procedure.
-
Turn the generator battery switch to the ON position. The power indicator light will illuminate.
-
Push and hold the red Pairing button on the back of the control panel until the START/STOP button illuminates.
-
Push and hold the STOP button on the key fob until the START/STOP button illumination turns OFF. Release the button. The START/STOP button will illuminate after the button is released.
-
Push and hold the START button on the key fob until the START/STOP button illumination turns OFF. Release the button. The START/STOP button will illuminate after the button is released.
-
Push the Pairing button on the side of the control panel until the START/STOP button illumination turns OFF. Release the button.
-
Turn the generator battery switch to the OFF position. The remote is now paired.
FUEL SELECTOR SWITCH
Position the fuel selector switch on the front control panel to the desired
fuel choice.
Push the fuel selector switch fully upward for gasoline operation.
Push the fuel selector switch fully downward for propane operation.
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running watts (6000 watts)
during the first five hours of operation.
Vary the load occasionally to allow stator windings to heat and cool and help
seat the piston rings.
LOW IDLE
NOTICE
Always start the generator with Low Idle OFF. Allow the engine speed to
stabilize before switching Low Idle ON.
NOTICE
The frequency output of the generator is dependent on engine speed. DO NOT use
Low Idle when powering sensitive electronics or large surge loads, such as an
air conditioner, electric pump, or refrigerator, or when connected to a home
transfer switch.
Low Idle minimizes fuel consumption, noise, and engine wear by lowering the engine RPM to idle (2400 RPM) when electrical loads have been turned off and automatically returns to rated speed when loads are turned back on. Turn Low Idle ON when powering intermittent, nonelectronic loads, such as power tools at a construction site.
BEFORE STARTING THE GENERATOR
Verify that:
- The generator is placed in a safe, appropriate location.
- The generator is on a dry, flat, and level surface.
- The engine is filled with oil.
- All loads are disconnected.
DANGER
Fire and explosion hazards. DO NOT move or tip the generator during
operation.
STARTING THE ENGINE: GASOLINE
During Push-Button or Remote Start the engine will automatically set the choke
and begin the start sequence. If the engine fails to start, the generator will
attempt to start the engine two more times. The battery switch can be turned
off at any time during the automatic start sequence to abort the engine start
attempt.
If the cranking speed drops after each unsuccessful attempt, then the battery
may not be adequately charged. See the BATTERY MAINTENANCE section.
-
Verify that fuel is in the gas tank.
-
Turn the fuel selector switch to gasoline operation.
-
Turn the fuel tank valve to the ON position.
-
Push the battery switch to the ON position.
-
Choose the starting method:
a. Remote Start: Push and hold the START button on the remote start key fob for one second.
Note: Remote start-equipped generators must be restarted with the START/STOP switch on the control panel after an automatic shutdown occurs.
b. Push-Button Start: Push and hold the engine
START/STOP button for two seconds.
STARTING THE ENGINE: PROPANE
DANGER
Fire and explosion hazards. Always turn the propane tank valve to the fully
closed position if not operating the generator on propane.
- Make sure the LPG/propane hose is correctly connected to the generator and propane tank.
- Turn the fuel selector switch to propane operation.
- Fully open the valve on the propane tank.
- Push the battery switch to the ON position.
- Choose the starting method:
a. Remote Start: Push and hold the START button on the remote start key fob for one second.
b. Push-Button Start: Push and hold the engine START/STOP button for two seconds.
SWITCHING FUEL SOURCES
DANGER
Fire and explosion hazards. DO NOT add gasoline to the fuel tank or connect
the LPG/propane hose to the generator while the generator is in operation.
The fuel source can be switched while the engine is running if a propane tank
is connected to the generator BEFORE operation.
Note: Switching fuel sources while over 50% load capacity may cause the
engine to stop. If the engine stops when switching fuel sources, disconnect
all loads then restart the unit on the fuel source of choice.
GASOLINE TO PROPANE
IMPORTANT : Load capacity is reduced when running on propane. Make sure
the generator can supply enough (running) and surge (starting) watts for the
items you are powering before switching to propane.
- Fully open the valve on the propane tank.
- Turn the fuel selector switch to propane operation.
- Turn the fuel tank valve to the OFF position.
PROPANE TO GASOLINE
- Turn the fuel tank valve to the ON position.
- Turn the fuel selector switch to gasoline operation.
- Turn the propane tank valve to the fully closed position.
Note: When switching to propane operation the engine may run rough for a few seconds while it purges gasoline in the carburetor.
STOPPING THE ENGINE
-
Turn off and unplug all connected electrical loads.
IMPORTANT: Never start or stop the generator with electrical devices connected. -
Let the generator run with no load for several minutes to stabilize the internal temperatures of the engine.
-
Push and hold the START/STOP button for one second or push STOP on the remote start key fob for one second.
Note: Alternately, if the generator is used infrequently, turn the fuel tank valve to the OFF position to limit the residual fuel remaining in the system. The engine will stop when fuel in the carburetor and fuel line is exhausted. -
Push the battery switch to the OFF position.
-
If operating on propane, turn the propane tank valve to the fully closed position.
FREQUENCY OF USE
If the generator will be used on an infrequent or intermittent basis (more
than one month before the next use), refer to the Battery Maintenance and
Storage sections of this manual for information regarding battery charging and
fuel deterioration.
AC CIRCUIT BREAKERS
The circuit breakers will automatically switch OFF if there is a short circuit
or a significant overload of the generator at each receptacle.
If an AC circuit breaker switches OFF automatically, check that the appliance
is working correctly and it does not exceed the rated load capacity of the
circuit before resetting the AC circuit breaker ON.
The main circuit breaker controls the total output of all outlets to protect
the generator from overload or short circuits.
GENERATOR CAPACITY
NOTICE
Do not overload the generator’s capacity. Exceeding the generator’s
wattage/amperage capacity can damage the generator and/or electrical devices
connected to it.
Make sure the generator can supply enough continuous (running) and surge
(starting) watts for the items you will power at the same time.
The total power requirements (Volts x Amps = Watts) of all appliances
connected must be considered. Appliance and power tool manufacturers usually
list rating information near the model or serial number.
To determine power requirements:
- Select the items you will power at the same time.
- Total the continuous (running) watts of these items. This is the amount of power the generator must produce to keep the items running. See the wattage reference chart on the next page.
- Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
Example:
Tool or Appliance | Running Watts* | Starting Watts* |
---|---|---|
RV Air Conditioner (11,000 BTU) | 1010 | 1600 |
TV (Tube Type) | 300 | 0 |
RV Refrigerator | 180 | 600 |
Radio | 200 | 0 |
Light (75 Watts) | 300 | 0 |
Coffee Maker | 600 | 0 |
2590 total |
Running
Watts| 1600
Highest
Starting
Watts
| Total Running Watts
Highest Starting Watts| 2590
+ 1600
| Total Starting Watts Needed| 4190
*Wattages listed are approximate. Verify actual wattage.
POWER MANAGEMENT
To prolong the life of the generator and attached devices, use care when
adding electrical loads to the generator. There should be nothing connected to
the generator outlets before starting the engine. The correct and safe way to
manage generator power is to sequentially add loads as follows:
- With nothing connected to the generator, start the engine as described in this manual.
- Plug in and turn on the first load, preferably the largest load you have.
- Permit the generator output to stabilize (the engine runs smoothly and the attached device operates properly).
- Plug in and turn on the next load.
- Again, permit the generator to stabilize.
- Repeat steps 4 and 5 for each additional load.
Wattage Reference
Tool or Appliance | Estimated Running Watts* | Estimated Starting Watts* |
---|
Incandescent Lights
(4 Quantity x 75 Watts)
TV (Tube Type)
Sump Pump (1/3 hp)
Refrigerator or Freezer
Well Pump (1/3 hp)
Furnace (1/2 hp) Radio
Drill (3/8”, 4 amps) Circular Saw
(Heavy Duty, 7-1/4”)
Miter Saw (10”)
Table Saw (10”)| 300
300
800
700
1000
800
200
440
1400
1800
2000| 0
0
1300
2200
2000
2350
0
600
2300
1800
2000
*Wattages listed are approximate. Verify actual wattage.
EXTENSION CORDS
WARNING
Asphyxiation hazard. Extension cords running directly into the home increase
the risk of carbon monoxide poisoning through any openings. If an extension
cord running directly into your home is used to power indoor items, there is a
risk of carbon monoxide poisoning to people inside the home. Always use
battery-powered carbon monoxide detector (s) that meet current UL 2034 safety
standards when running the generator. Regularly check the detector (s)
battery.
WARNING
Asphyxiation hazard. When operating the generator with extension cords, make
sure the generator is located in an open, outdoor area, far away from occupied
spaces with exhaust pointed away.
WARNING
Fire and electrocution hazard. Never use worn or damaged extension cords.
Damaged or overloaded extension cords could overheat, arc, and burn to result
in death or serious injury.
Before connecting an AC appliance or power cord to the generator:
- Use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.
- Make sure the tool or appliance is in good working order. Faulty appliances or power cords can create a potential for electric shock.
- Make sure the electrical rating of the tool or appliance does not exceed the rated power of the generator or the receptacle being used.
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for outdoor use that is rated
for the electrical load.
Total Amperage | Minimum Gauge, Outdoor Rated |
---|
Up to 50 FT (15 M) Up to 100 FT (30 M)
Up to 10A| 0| 8
Up to 15A| 10| 8
Up to 20A| 10| 6
Up to 30A| 8| 6
Up to 35A| 6| 6
ST SWITCH
The generator is compatible with the Westinghouse ST Switch, purchased
separately. When utility power is on it will provide power (up to 120V @ 20A)
to the appliances plugged into the 5-20R receptacle on the ST Switch. When
utility power is lost the ST Switch automatically transfers input power from
utility to generator power. When utility
power is restored, the ST Switch transfers input power back to the utility.
Visit
www.westinghouseoutdoorpower.com
for more information.
TRANSPORTING
CAUTION
Weight hazard. Always have assistance when lifting the generator.
- Allow the generator to cool for a minimum of 30 minutes before transporting.
- If operating on propane, turn the propane tank valve to the fully closed position.
- Disconnect the LPG/propane hose from the generator and propane tank.
- Replace all protective covers on the generator control panel.
- Keep the unit level during transport to minimize the possibility of fuel leakage or, if possible, drain the fuel or run the engine until the fuel tank is empty before transport.
- The generator wheels are only intended for hand transport. The wheels are not suitable for towing the generator either on or off-road.
- Use the extendable handle for hand transport. Only use the handle while the generator is OFF, stationary, and resting on a horizontal surface. Do not use the handle to lift the generator entirely off the ground, tow it, or up-end it.
CAUTION
Fire hazard. Do not up-end the generator or place it on its side. Fuel or oil
can leak and damage to the generator may occur.
LIFTING HOOK
Only use the lifting hook to lift the unit or attach any load restraints such
as ropes or tie-down straps. Do not attempt to lift or secure the generator by
holding onto any of its
other components.
Before lifting the generator, inspect the bracket and make sure it is securely
fastened to the generator. Do not lift the generator unless the lifting
bracket is securely fastened.
- Hook a chain or strap through the eye on the lifting hook and make sure it is securely fastened.
- Connect a suitable lifting device to the chain or strap. Inspect the chain and hook for any damaged links or any defects that could cause failure. It is recommended to use hooks with safety latches installed.
- Lift the generator slightly to ensure it is lifting straight and level.
MAINTENANCE
MAINTENANCE
WARNING
Accidental start-up. Disconnect the spark plug boot from the spark plugs when
performing maintenance on the generator.
MAINTENANCE SCHEDULE
Regular maintenance will improve performance and extend the service life of
the generator. Follow the hourly or calendar intervals, whichever occurs
first. More frequent service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
Check air filter
After First 20 Hours or First Month
Change engine oil1
After 50 Hours or Every 3 Months
Clean air filter2
After 100 Hours or Every 6 Months
Change engine oil1
Inspect/clean spark arrestor
Inspect/clean spark plug
Replace fuel filter
Clean float bowl3
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Replace fine oil filter
Inspect/adjust valve clearance3
Every 2 years
Replace fuel pipe
- Change oil every month when operating under heavy loads or in high temperatures.
- Clean more often under dirty or dusty conditions. Replace the air filter if it cannot be adequately cleaned.
- Recommend service to be performed by an authorized Westinghouse service dealer.
MAINTENANCE REPLACEMENT PARTS
Description | Part Number |
---|---|
Air filter | 5061 |
Oil drain bolt crush washer | 94242 |
Battery, 18 AH | 511092 |
Fuel filter | 516401 |
Spark plug | 97108 (F7TC) |
Spark Arrester | 6859 |
AIR FILTER MAINTENANCE
The air filter must be cleaned after every 50 hours of use or six months
(frequency should be increased if the generator is operated in a dusty
environment).
-
Place the generator on a level surface and allow the engine to cool for several minutes.
-
Release the four clips then remove the air filter cover.
-
Remove the air filter and clean using compressed air. DO NOT submerge the filter in liquids or add oil.
-
Install the air filter in the housing, making sure it is correctly oriented and seated in the housing.
-
Install the air cleaner cover and secure it with the cover clips.
ENGINE OIL LEVEL CHECK
CAUTION
Avoid skin contact with engine oil. Wear protective clothing and equipment.
Wash all exposed skin with soap and water.
NOTICE
Always use the specified engine oil. Failure to use the specified engine oil
can cause accelerated wear and/or shorten the life of the engine.
When using the generator in dusty conditions or in extremely hot weather,
change the oil more frequently.
Ambient air temperature will affect engine oil performance. Change the type of
engine oil used based on weather conditions.
Check the engine oil level before each use or every 8 hours of operation.
-
Place the generator on a level surface and allow the engine to cool for several minutes.
-
Remove the oil dipstick and wipe the dipstick clean.
-
Insert, then remove the oil dipstick.
Acceptable Oil Level – On the flat side of the dipstick, oil is visible up to the first notch.
Low Oil – Oil is below the first notch on the dipstick
-
If low, remove the oil fill cap and add the recommended engine oil incrementally and recheck until the level is at the top-notch on the dipstick. DO NOT overfill. If over the top-notch on the dipstick, drain the oil to reduce the oil level to the full mark.
-
Replace the oil dipstick and oil fill cap.
ENGINE OIL CHANGE
When using the generator in dusty conditions or extremely hot weather, change
the oil more frequently. Change the oil while the engine is still warm from
operation.
-
Place the generator on a level surface and allow the engine to cool for several minutes.
-
With a damp rag, clean around the oil fill cap. Remove the oil fill cap.
-
Place an oil pan (or suitable container) under the oil drain hose.
-
Unclip the oil drain hose and twist the cap counterclockwise to allow the oil to drain.
-
Twist the cap clockwise to close. Secure the hose in the hose clip.
-
Place the oil pan under the oil filter. Remove the oil filter by rotating it counterclockwise. Allow the oil to drain completely. Clean the area where the oil filter contacts the engine.
-
Apply clean oil to the rubber seal on the new oil filter. Install by hand, turning clockwise until the seal contacts the engine then turn another 3/4 turn. DO NOT over
tighten. -
Fill with the recommended oil. Stop frequently to check the oil level. Do not overfill. If the engine is overfilled, the excess oil may get transferred to the air cleaner housing and air filter. An indication of overfilling is white or blue smoke coming from the muffler when the engine is running.
-
Install the oil dipstick. Screw in the oil fill cap securely.
NOTICE
Do not pollute. Follow the guidelines of the EPA or other governmental
agencies for the proper disposal of hazardous materials. Consult local
authorities or reclamation facilities.
SPARK PLUG MAINTENANCE
NOTICE
Always use the Westinghouse OEM or compatible nonresistor-type spark plug. The
use of a resistor-type spark plug can result in rough idling, misfire, or may
prevent the engine from starting.
Inspect and clean the spark plugs after every 100 hours of use or six months. Replace the spark plugs after 300 hours of use or every year.
-
Place the generator on a level surface and allow the engine to cool.
-
Remove the spark plug boots by firmly pulling the boot directly away from the engine.
-
Clean the area around the spark plugs.
-
Remove the spark plugs with the included spark plug socket wrench.
NOTICE
Never apply any side load or move the spark plug laterally when removing the spark plug. -
Inspect the spark plugs. Replace if electrodes are pitted, or burned, or the insulator is cracked. Only use a recommended replacement plug.
-
Measure the spark plug electrode gap with a wire-type feeler gauge. If necessary, correct the gap by carefully bending the side electrode.
Spark plug gap: 0.024 – 0.032 in. (0.60 – 0.80 mm)
-
Carefully install each spark plug finger tight, then tighten it as an additional 3/8 to 1/2 turn with the spark plug wrench.
-
Attach the spark plug boots.
SPARK ARRESTOR SERVICE
Allow the muffler to cool completely before servicing the spark arrestor.
Check and clean the spark arrestor after every 100 hours of use or six months.
Failure to clean the spark arrestor will result in degraded engine
performance.
- Place the generator on a level surface.
- Carefully remove the carbon deposits from the spark arrestor screen with a wire brush. The spark arrestor must be free of breaks and tears. Use compressed air to clear removed deposits.
FUEL FILTER
Replace the fuel filter after 100 hours of use.
Note: Have an appropriate gasoline container and rags ready to catch
residual fuel in the filter and fuel line.
-
Allow the generator to cool completely.
-
Turn the fuel valve to the OFF position.
-
Note the orientation of the fuel filter. Using pliers, remove the fuel line clamps and remove the fuel filter.
-
Install the new fuel filter in the reverse order of removal.
BATTERY MAINTENANCE
WARNING
The battery gives off explosive hydrogen gas during normal operation. A spark
or flame can cause the battery to explode with enough force to kill or
seriously hurt you. Wear protective clothing and a face shield, or have a
skilled technician perform battery maintenance.
WARNING
Burn hazard. The battery contains sulfuric acid (electrolyte) which is highly
corrosive and poisonous. Wear protective clothing and eye protection when
working near the battery. Keep children away from the battery.
WARNING
NEVER smoke or work near sparks or other sources of ignition. NEVER touch
both battery terminals at the same time with your hand or any non-insulated
tools. If battery acid contacts skin or clothing, flush immediately with water
and neutralize with baking soda.
The battery shipped with the generator has been fully charged. A battery may
lose some charge when not in use for prolonged periods of time.
Note: Once started, the generator will charge the battery after 30–60
minutes of use.
When the generator is not running, the included trickle charger can remain
connected and will maintain the battery for an indefinite period of time. A
red light on the charger indicates charging is in progress. A green light
indicates charging is complete. Charge in a dry location.
- Plug the charger into the battery charging port on the control panel.
- Plug the wall receptacle end of the battery charger into a 120 Volt AC wall outlet.
BATTERY REPLACEMENT
CAUTION
Battery posts and terminals contain lead and lead compounds. Wash hands after
handling.
-
Remove the two battery plate bolts and battery plate. Tilt the battery forward and remove it.
-
Disconnect the negative (-) cable (black boot) from the negative (-) battery post.
-
Disconnect the positive (+) battery cable (red boot) from the positive (+) battery post.
NOTICE
Always connect the cables in the following sequence to avoid possible shock. -
On the replacement battery, connect the positive (+) battery cable (red boot) to the battery positive (+) terminal. Secure the boot over the battery post.
-
Connect the negative (-) battery cable (black boot) to the negative (-) positive terminal. Secure the boot over the battery post.
-
Install the battery in the battery tray. Install the battery plate and bolts. Tighten the bolts securely.
NOTICE
Dispose of the used battery properly according to the guidelines established
by your local or state government.
STORAGE
Proper storage preparation is required for trouble-free operation and
generator longevity.
NOTICE
Gasoline stored for as little as 30 days can deteriorate, causing gum,
varnish, and corrosive buildup in fuel lines, fuel passages, and the engine.
This corrosive buildup restricts the flow of fuel, which can prevent the
engine from starting after a prolonged storage period. The use of fuel
stabilizers significantly increases the storage life of gasoline. Full-time
use of fuel stabilizer is recommended. Follow the manufacturer’s instructions
for use.
STORAGE TIME | RECOMMENDED PROCEDURE |
---|---|
Less than 1 month | No service is required. |
2 to 6 months | Fill with fresh gasoline and add a gasoline stabilizer. Drain |
the carburetor float bowl.
6 months or longer| Drain the fuel tank and carburetor float bowl.
SHORT TERM STORAGE
- Allow the generator to cool a minimum of 30 minutes before storage.
- If operating on propane, turn the propane tank valve to the fully closed position and disconnect the LPG/ propane hose from the generator and propane tank.
- Replace all protective covers on the generator control panel.
- Wipe the generator with a moist cloth. Clean any debris from the muffler cooling vents.
- Store the generator in a well-ventilated, dry location away from sparks, open flames, pilot lights, heat, and other sources of ignition such as areas with a spark-producing electric motor or where power tools are operated.
- Do not store the generator, gasoline, or propane tanks near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
- With the engine and exhaust system cool and all surfaces dry, cover the generator to keep out dust. Do not use a plastic sheet as a dust cover. Non-porous materials trap moisture and promote rust and corrosion.
LONG TERM STORAGE
Even properly stabilized fuel can leave residue and cause corrosion if left
long-term. If storing the generator for over six months, drain the fuel tank.
DRAINING THE FUEL TANK
If storing the generator for longer than six months, drain the fuel tank to
prevent fuel separation, deterioration, and deposits in the fuel system.
-
Unscrew the fuel tank cap. Remove the fuel screen filter by slightly compressing it while removing it from the tank.
-
Using a commercially available gasoline hand pump (not included), siphon the gasoline from the fuel tank into an approved gasoline container. DO NOT use an electric pump.
OR
Disconnect the fuel line from the bottom of the fuel tank and allow the fuel to drain into an approved gasoline container. Reinstall the fuel line. -
Reinstall the fuel screen filter and the fuel tank cap.
-
Start the generator and allow it to run until the generator engine stops.
-
Push the battery switch to the OFF position.
-
Disconnect the battery.
VALVE CLEARANCE
NOTICE
Checking and adjusting valve clearance must be done when the engine is cold.
Perform this procedure on both cylinders.
- Remove the rocker arm cover and carefully remove the gasket. If the gasket is torn or damaged, it must be replaced.
- Remove the spark plug so the engine can be rotated more easily.
- Rotate the engine to Top Dead Center (TDC) by momentarily pushing the Start button. Looking through the spark plug hole, the piston should be at the top (both valves are closed).
- Both the rocker’s arms should be loose at TDC on the compression stroke. If they are not, rotate the engine 360°.
- Insert a feeler gauge between the rocker arm and the valve stem to measure valve clearance.
| Intake Valve| Exhaust Valve
---|---|---
Valve Clearance| 0.0031 – 0.0047 in (0.08 – 0.12 mm)| 0.0051 – 0.0067 in (0.13 – 0.17 mm)
Torque| 8-12 N•m| 8-12 N•m - If an adjustment is necessary, hold the rocker arm pivot and loosen the pivot adjusting nut.
- Turn the rocker arm pivot to obtain the specified clearance. Hold the rocker arm pivot and re-tighten the pivot adjusting the nut to the specified torque. Torque: 106 inch-pound (12 N•m)
- Perform this procedure for the other valve.
- Install the gasket, rocker arm cover, and spark plug.
TROUBLESHOOTING
TROUBLESHOOTING
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | CORRECTION |
---|---|---|
Engine will not start | Battery switch in the OFF position. | Turn the battery |
switch to the ON position.
Out of fuel.| Refuel.
Bad fuel, generator stored without treating or draining gasoline or refueled
with bad gasoline.| Drain the fuel tank. Refuel with fresh gasoline.
Dirty air fitter.| Clean the air filter.
The low engine oil level stopped the generator.| If the low oil LED is
illuminated, turn the battery switch to the OFF position. Add engine oil.
Spark plug wet with fuel (flooded engine).| Wait five minutes. Turn the
battery switch to the OFF position. Pull the recoil handle rapidly several
times. If the generator does not start. remove the spark plug and dry.
Spark plug faulty fouled, or improperly gapped.| Gap or replace the spark
plug. Reinstall.
Fuel filter restricted. fuel system malfunction, fuel pump failure, ignition
malfunction. valves stuck. etc.| Contact Westinghouse customer service toll-
free at 1 855-944-3571.
Battery drained.| Use the recoil handle to start the generator.
Charge the battery.
The choke is partially open or closed due to a weak or disconnected battery.|
Manually set the choke. See the Maintenance section.
Engine starts. then shuts down| Out of fuel.| Refuel.
Incorrect engine oil level.| Check engine oil level.
Dirty air filter.| Clean the air filter.
Contaminated fuel.| Drain the fuel tank. Refuel with fresh gasoline.
Defective low oil level switch.| Contact Westinghouse customer service toll-
free at 1 (855) 9443571.
Engine lacks power| Air filter restricted.| Clean or replace air filter.
Bad fuel. generator stored without treating or draining gasoline. or refueled
with bad gasoline.| Drain the fuel tank. Refuel with fresh gasoline.
Fuel filter restricted. fuel system malfunction, fuel pump failure. ignition
malfunction. valves stuck. etc.| Contact Westinghouse customer service toll-
free at 1 855-944-3571.
Engine runs rough or bogs when the load applied| Dirty air filter.| Clean the
air filler.
Generator overloaded.| Unplug some devices.
Faulty power tool or appliance.| Replace or repair tools or appliances. Stop
and restart the engine.
Fuel filter restricted. fuel system malfunction, fuel pump failure. ignition
malfunction, valves stuck. etc.| Contact Westinghouse customer service toll-
free at 1 855-944-3571.
No power at AC receptacles| THE OUTPUT READY LED is OFF and OVERLOAD LED is
ON.| Check AC load. Stop and restart the engine.
Check the air inlet. Stop and restart the engine.
AC circuit breaker/s tripped.| Check AC loads and reset circuit breaker/s.
Faulty power tool or appliance.| Replace or repair tools or appliances. Stop
and restart the engine.
Faulty generator.| Contact Westinghouse customer service toll-free at 1 (855)
9443571.
PROBLEM| POSSIBLE CAUSE| CORRECTION
---|---|---
Frost on the propane tank or regulator| ‘If the temperature of the propane
tank drops below the dew point, condensation on the tank may turn to frost or
ice. This typically occurs in humid conditions.| Providing all the propane
fuel handling equipment is functioning normally, no correction is needed.
The Propane tank is not equipped with an Overfilling Prevention Device (OPD).|
If you suspect your propane fuel tank is not equipped with an OPD device,
discontinue operation immediately and replace the propane fuel tank with a
propane tank equipped with an OPD.
The propane fuel tank was overfilled.| If you suspect your propane fuel tank
has been overfilled, discontinue operation immediately and return the propane
fuel tank to the place of purchase or refilling.
Propane fuel smell| Fuel regulator or fuel hose and fittings not securely
sealed.| Using a soap solution check each connection and tighten as needed.
Propane fuel regulator vent active.| The propane fuel regulator is equipped
with a vent that will allow a small amount of propane fuel vapor to escape
from the regulator when the propane tank valve is opened. This can be normally
provided the venting of the propane is brief. If you suspect that this is
abnormal, immediately discontinue use and have the propane regulator inspected
by a qualified technician.
Residual fuel from the carburetor disperses after the operation.| Normal, no
correction is needed.
Poor performance or engine stalling on Propane| Propane fuel line kinked or
crushed.| Inspect the propane fuel line and remove kinks or other
obstructions.
Fuel selector valve is not properly positioned.| Rotate the fuel valve fully
until the pointer is directly in line with the desired fuel.
Gasoline is not purged from the carburetor before switching to propane.| Close
the propane fuel tank valve. Move the fuel selector switch to gas. Start the
engine and allow the engine to run until the gasoline has been consumed in the
carburetor. Begin the propane start-up procedure.
EXPLODED VIEW
EXPLODED VIEWS AND PARTS LISTS
ENGINE EXPLODED VIEW
ENGINE PARTS LIST
NO.| PART #| DESCRIPTION| NO.| PART #|
DESCRIPTION
---|---|---|---|---|---
1| 50120038| CRANKCASE ASSEMBLY| 6.6| 320400| FLYWHEEL ASSEMBLY
1.1| 91371| BOLT M6X35| 7| 50090059| WIND-LEAD COVER ASSEMBLY
1.2| 91043| BOLT M6X113| 7.1| 90043| NUT M6
1.3| 93530| CRANKSHAFT OIL SEAL| 7.2| 324701| RECOIL COVER ASSEMBLY
1.4| 91365| BOLT M6X12| 7.3| 94260| FLAT WASHER
1.5| 320503| LEFT WINDSHIELD| 7.4| 91370| BOLT M6X16
1.6| 320504| RIGHT WINDSHIELD| 7.5| 599601| METAL CLAMP
1.7| 91374| BOLT M6X22| 8| 50260011| STARTER MOTOR ASSEMBLY
1.8| 320602| BREATHER VALVE ASSEMBLY| 8.1| 91378| BOLT M8X110
1.9| 320600| BREATHING VALVE COVER| 8.2| 97414| STARTER ALTERNATOR
1.1| 96133| BREATHING VALVE GASKET| 8.3| 240904| LOCATING PIN 8X12
1.1| 599601| METAL CLAMP| 9| 50040083| CARBURETOR ASSEMBLY
1.12| 94419| FUEL HOSE CLIP 16.5×2| 9.1| 319901| CARBURETOR SOLENOID VALVE
LINE
1.13| 320206| CRANKCASE| 9.2| 95464| CARBURETOR OVERFLOW PIPE
1.14| 240904| LOCATING PIN 8X12| 9.3| 94423| FUEL HOSE CLIP 9
1.15| 329902| ROCKER ARM SUPPORT BASE
ASSEMBLY| 9.4| 94421| FUEL HOSE CLIP 16×12×1
1.16| 95618| BLAST PIPE| 9.5| 94406| FUEL HOSE CLIP 13.5
1.17| 94033| SEALING RING| 9.6| 517319| LOW-PRESSURE PIPE
1.18| 96296| CRANKCASE COVER GASKET| 9.7| 517314| LOW-PRESSURE PIPE
1.19| 327001| PLUG| 9.8| 545318| IDLE SPEED MEASURING HOLE
1.2| 91370| BOLT M6X16| 9.9| 545317| MAIN MEASURING HOLE
1.21| 329900| CRIMPING BOARD| 9.1| 545316| MAIN MEASURING HOLE
1.22| 260901| LOCATING PIN| 9.11| 329925| FIVE-WAY CONNECTOR
1.23| 325101| OIL PROTECTOR| 9.12| 94402| FUEL HOSE CLIP 8.5
1.24| 91832| BOLT M14X1.5X12| 9.13| 91383| BOLT M6X28
1.25| 94242| FLAT WASHER| 9.14| 96141| CARBURETOR HEAT SHIELD
1.26| 91887| OIL DRAIN SOLENOID| 9.15| 91425| BOLT M6X65
2| 50690001| PETROL PUMP ASSEMBLY| 9.16| 94408| FUEL HOSE CLIP 10
2.1| 95545| GASOLINE PUMP INLET PIPE| 9.17| 501138| CLAMP
2.2| 95546| GASOLINE PUMP OUTLET PIPE| 9.18| 92239| BOLT M3*8
2.3| 94423| FUEL HOSE CLIP 9| 9.19| 95906| CARBURETOR CONNECTION ELBOW
2.4| 516401| FILTER| 9.2| 329929| STEPPER MOTOR
2.5| 95463| GASOLINE PUMP NEGATIVE PRESSURE PIPE| 9.21| 329924| STEPPER MOTOR
2.6| 94418| PROTECTIVE SLEEVE| 9.22| 322811| DOUBLE CHAMBER CARBURETOR
2.7| 369904| GASOLINE PUMP BRACKET| 9.23| 517309| LOW PRESSURE PIPE
2.8| 329914| PETROL PUMP| 9.24| 96137| CARBURETOR GASKET
2.9| 91370| BOLT M6X16| 10| 50020051| CYLINDER HEAD ASSEMBLY
3| 50100029| RIGHT IGNITER ASSEMBLY| 10.1| 91365| BOLT M6X12
3.1| 91383| BOLT M6X28| 10.2| 320507| WIND-LEAD-COVER
3.2| 91043| BOLT M6X113| 10.3| 261702| INTAKE VALVE
3.3| 97540| RIGHT IGNITER| 10.4| 260802| VALVE LOCK CLAMP
4| 50100028| LEFT IGNITER ASSEMBLY| 10.5| 96135| INTAKE WASHER
4.1| 91383| BOLT M6X28| 10.6| 321900| PUSH ROD
4.2| 91043| BOLT M6X113| 10.7| 322201| LIMIT PLATE ASSEMBLY
4.3| 97539| LEFT IGNITER| 10.8| 261807| INTAKE VALVE SPRING LOWER SEAT
5| 50680002| CHARGING COIL ASSEMBLY| 10.9| 93513| VALVE SEAL
5.1| 97212| CHARGING COIL| 10.1| 326000| VALVE SPRING
5.2| 91371| BOLT M6X35| 10.11| 261805| VALVE SPRING SEAT
6| 50180019| FLYWHEEL ASSEMBLY| 10.12| 322100| ROCKER ARM ASSEMBLY
6.1| 91385| BOLT M8X16| 10.13| 91380| BOLT M10X80
6.2| 90041| NUT M20| 10.14| 265903| INTAKE VALVE
6.3| 94030| FLAT WASHER| 10.15| 321005| RIGHT CYLINDER HEAD ASSEMBLY
6.4| 329913| IMPELLER PRESSURE PLATE| 10.16| 261806| TOP CAP
6.5| 324600| IMPELLER| 11| 97110| SPARK PLUG
| | | 12| 50130015| WIND LEAD COVER ASSEMBLY
| | | 12.1| 91385| BOLT M8X16
ENGINE PARTS LIST CONTINUED
NO. | PART # | DESCRIPTION | NO. | PART # | DESCRIPTION |
---|---|---|---|---|---|
12.2 | 91365 | BOLT M6X12 | 18.16 | 265903 | INTAKE VALVE |
12.3 | 325801 | TEMPERATURE SENSOR | 19 | 50600003 | SEAL WASHER ASSEMBLY |
12.4 | 329901 | LIFTING EAR | 19.1 | 94206 | SPRING WASHER |
12.5 | 320501 | RIGHT CYLINDER HEAD AIR DEFLECTOR | 19.2 | 91007 | BOLT M8X38 |
13 | 50010033 | CYLINDER HEAD COVER ASSEMBLY | 19.3 | 96140 | EXHAUST GASKET |
13.1 | 91365 | BOLT M6X12 | 19.4 | 90011 | NUT M8 |
13.2 | 321101 | RIGHT CYLINDER HEAD COVER | 20 | 50050023 | PISTON & PISTON RING |
ASSEMBLY
13.3| 96136| CYLINDER HEAD COVER GASKET| 20.1| 241301| PISTON PIN RING
14| 50030058| AIR CLEANER ASSEMBLY| 20.2| 325500| PISTON PIN
14.1| 91371| BOLT M6X35| 20.3| 321500| CONNECTING ROD ASSEMBLY
14.2| 91383| BOLT M6X28| 20.4| 321200| PISTON
14.3| 94402| FUEL HOSE CLIP 8.5| 20.5| 321602| PISTON RING COMBINATION
14.4| 95117| CARBON CANISTER AND AIR FILTER CONNECTING PIPE| 21| 50190004|
CRANKSHAFT ASSEMBLY
14.5| 323000| AIR FILTER PRESSURE PLATE| 21.1| 320300| CRANKSHAFT
14.6| 322902| AIR CLEANER ASSEMBLY| 21.2| 94031| FLAT WASHER
14.6.1| 5061| AIR CLEANER ELEMENT| 22| 50710001| HEAT SINK ASSEMBLY
15| 50700001| AIR FILTER CONNECTING PIPE
ASSEMBLY| 22.1| 91383| BOLT M6X28
15.1| 91377| BOLT M6X95| 22.2| 95465| RADIATOR CONNECTING OIL PIPE
15.2| 95907| DUAL CHAMBER INTAKE PIPE| 22.3| 94421| FUEL HOSE CLIP 16×12×1
15.3| 96139| INTAKE PIPE GASKET| 22.4| 329911| RADIATOR MOUNTING BRACKET
15.4| 95905| AIR FILTER CONNECTING PIPE| 22.5| 329912| RADIATOR ASSEMBLY
15.5| 92048| SCREW M8X50| 23| 50200040| CRANKCASE COVER ASSEMBLY
15.6| 96138| AIR FILTER CONNECTING PIPE GASKET| 23.1| 91371| BOLT M6X35
16| 50010034| CYLINDER HEAD COVER ASSEMBL| 23.2| 329909| OIL FILTER SEAT
16.1| 91365| BOLT M6X12| 23.3| 91833| OIL FILTER CONNECTING SOLENOID
16.2| 321400| OIL PLUG| 23.4| 91383| BOLT M6X28
16.3| 321100| LEFT CYLINDER HEAD COVER| 23.5| 93530| CRANKSHAFT OIL SEAL
16.4| 96136| CYLINDER HEAD COVER GASKET| 23.6| 91331| BOLT M6X25
17| 50130016| WIND LEAD COVER ASSEMBLY| 23.7| 91342| BOLT M8*12
17.1| 91385| BOLT M8X16| 23.8| 93023| BEARING
17.2| 91365| BOLT M6X12| 23.9| 325100| OIL SENSOR
17.3| 320506| LEFT CYLINDER HEAD AIR DEFLECT| 23.1| 329907| OIL FILTER COVER
17.4| 329901| LIFTING EAR| 23.11| 92047| SCREW M6X16
17.5| 329922| TUBING BRACKET| 23.12| 329903| OIL PUMP ASSEMBLY
17.6| 94418| PROTECTIVE SLEEVE| 23.13| 324301| CENTRIFUGAL GOVERNOR GEAR
ASSEMBLY
18| 50020052| CYLINDER HEAD ASSEMBLY| 23.14| 325600| DIPSTICK ASSEMBLY
18.1| 91365| BOLT M6X12| 23.15| 329904| PRESSURE RELIEF VALVE SPRING
18.2| 261702| INTAKE VALVE| 23.16| 329905| STEEL BALL
18.3| 260802| VALVE LOCK CLAMP| 23.17| 320900| LOCATING PIN
18.4| 96135| INTAKE WASHER| 23.18| 320101| CRANKCASE COVER
18.5| 320502| WIND-LEAD-COVER| 23.19| 94085| O-SHAPE SEAL RING
18.6| 321004| LEFT CYLINDER HEAD ASSEMBLY| 23.2| 329908| OIL FILTER
18.7| 321900| PUSH ROD| 23.21| 91834| OIL FILTER SEAT CONNECTION PIPE
18.8| 322201| LIMIT PLATE ASSEMBLY| 23.22| 91379| BOLT M8X50
18.9| 261807| INTAKE VALVE SPRING LOWER SEA| 23.23| 329906| OIL FILTER
18.1| 93513| VALVE SEAL| 23.24| 94241| FLAT WASHER 10.2X17X1
18.11| 326000| VALVE SPRING| 23.25| 94257| FLAT WASHER 8×16×1.5
18.12| 261805| VALVE SPRING SEAT| 24| 50150012| ALTERNATOR ASSEMBLY
18.13| 261806| TOP CAP| 24.1| 322000| CAMSHAFT ASSEMBLY
18.14| 322100| ROCKER ARM ASSEMBLY| 24.2| 94032| FLAT WASHER
18.15| 91380| BOLT M10X80| | |
GENERATOR EXPLODED VIEW
GENERATOR PARTS LIST
NO.| PART #| DESCRIPTION| NO.| PART #|
DESCRIPTION
---|---|---|---|---|---
1| 1.14872E+12| ENGINE DHTLG720E| 4.1.17| 6386| GROUND BOLT ASSEMBLY
2| 60070062| FRAME KIT ASSEMBLY| 4.1.18| 6385| L14-30R RECEPTACLE
2.1| 90026| SELF-LOCKING NUTS| 4.1.19| 6848| WATERPROOF CAP
2.2| 501041| DAMPING SUPPORT B| 4.1.20| 6383| L5-30R RECEPTACLE
2.3| 90075| NUT M101.5| 4.1.21| 6847| WATERPROOF CAP
2.4| 91343| BOLT M816| 4.1.22| 6275| GFCI SOCKET 5-20RA
2.5| 770048-116| FRAME| 4.1.23| 6845| WATERPROOF CAP
2.6| 91345| BOLT M8X20| 4.1.24| 6439-20| 20A THERMAL PROTECTOR
2.7| 518403| OIL SWITCH SEAT| 4.1.25| 1041| CO INDICATOR (RED)
2.8| 501131| AIR DUCT WELDING PARTS| 4.2| 96120| PAPER WASHER
2.9| 91339| BOLT M6X50| 4.3| 91327| BOLT M612
2.1| 528606| GLUE CARD| 4.4| 534905| AVR
2.11| 90016| NUT M6| 4.5| 91306| BOLT M625
2.12| 526614-116| HANDLE| 4.6| 599078| CO FLAMEOUT ACTUATOR
2.13| 528501| HANDLE RUBBER SLEEVE| 5| 60060032| WHEEL KIT ASSEMBLY
2.14| 91363| BOLT M850| 5.1| 501137| CASTER SHAFT ASSEMBLY
2.15| 527406| HANDLE PIN| 5.2| 94213| FLAT WASHER
2.16| 527401| HANDLE DAMPING RUBBER PAD| 5.3| 523623| WHEEL
2.17| 533604-116| LIFTING BRACKET| 5.4| 548301| COTTER PIN
2.18| 535602-116| INSULATION BOARD| 6| 60200028| BATTERY BRACKET KIT ASSEMBLY
2.19| 94224| CRANKSHAFT FLAT WASHER Φ10302| 6.1| 91327| BOLT M612
2.2| 91327| BOLT M612| 6.2| 512042| BATTERY POSITIVE WIRE
3| 60150031| FOOT BRACKET KIT ASSEMBLY| 6.3| 512015| BATTERY NEGATIVE WIRE
3.1| 531905| FOOT BRACKET ISOLATION
SUPPORT| 6.4| 599702| ADHESIVE STRIP
3.2| 90026| SELF-LOCKING NUTS| 6.5| 501135-116| BATTERY HOLDER
3.3| 525905-116| FOOT BRACKET ASSEMBLY| 6.6| 511092| BATTERY
3.4| 91343| BOLT M816| 7| 60140045| ALTERNATOR KIT ASSEMBLY
4| 60040090| PANEL KIT ASSEMBLY| 7.1| 533602| MOTOR FRONT COVER
4.1| 715553| PANEL ASSEMBLY| 7.2| 91354| BOLT M10×1.25
4.1.1| 1042| CO INDICATOR(YELLOW)| 7.3| 750009| ALTERNATOR ASSEMBLY
4.1.2| 536002| ONE PUSH BOTTON SWITCH| 7.3.1| 6186| CARBON BRUSH
4.1.3| 6393| BATTERY INDICATOR| 7.3.2| 6188| TERMINAL
4.1.4| 6502| POWER SWITCH| 7.4| 91325| BOLT M612
4.1.5| 6685| ECO SWITCH| 7.5| 544612| SHORT WIRE
4.1.6| 6683| FUEL SELECTOR SWITCH| 7.6| 96813| FLAT WASHER
4.1.7| 6439-30| 30A THERMAL PROTECTOR| 7.7| 91725| BOLT M101.25295
4.1.8| 6796| USB SOCKET 10-35V| 7.8| 533603| BACK SUPPORT
4.1.9| 6436-30| BREAKER 2P30A| 7.9| 91623| BOLT M81.25215
4.1.10| 6041| DIGITAL DISPLAY| 7.1| 91323| BOLT M5X16
4.1.11| 6513-50| BREAKER 2P50A| 7.11| 91322| BOLT M512
4.1.12| 9001| PANEL REAR COVER| 7.12| 533304-221| ALTERNATOR TAIL COVER
4.1.13| 6488| AVIATION SOCKET GXP20-7P| 8| 60490016| PRESSURE-REDUCING VALVE
KIT ASSEMBLY
4.1.14| 6387| DC CHARGING SOCKET 2.0mm| 8.1| 96120| PAPER WASHER
4.1.15| 6254| AMERICAN FOUR-HOLE
INDUSTRIAL SOCKET 14-50R| 8.2| 91306| BOLT M6*25
4.1.16| 6850| WATERPROOF CAP| 8.3| 90016| NUT M6
| | | 8.4| 517318| LOW-PRESSURE HOSE
THE GENERATOR PARTS LIST CONTINUED
NO.| PART #| DESCRIPTION| NO.| PART #|
DESCRIPTION
---|---|---|---|---|---
8.5| 326301| INTAKE CONNECTOR Ⅱ| 11.2| 96140| EXHAUST GASKET
8.6| 326302| OUTLET CONNECTOR Ⅰ| 11.3| 94206| SPRING WASHER Φ8
8.7| 326303| OURLET CONNECTOR| 11.4| 90011| NUT M8
8.8| 327203| INTAKE CONNECTOR| 11.5| 95253| MUFFLER CONNECTING PIPE
8.9| 545910| PRESSURE REDUCING VALVE| 11.6| 96149| MUFFLER CONNECTING PIPE
GASKET
8.1| 326401| PRESSURE REDUCING VALVE| 11.7| 94201| SPRING WASHER Φ10
8.11| 519387| PROTECTIVE CASE| 11.8| 515912| THE EXHAUST MUFFLER GUARD COVER A
8.12| 501138| CLAMP| 11.9| 515913| EXHAUST MUFFLER GUARD COVER B
8.13| 91312| BOLT M645| 11.1| 515911| EXHAUST MUFFLER GUARD COVER C
9| 60010069| FUEL TANK KIT ASSEMBLY| 11.11| 705010| MUFFLER
9.1| 91461| BOLT M6X25| 11.11.1| 6859| SPARK ARRESTER
9.2| 700905L-116| FUEL TANK| 11.12| 91345| BOLT M8X20
9.3| 519428| FUEL CAP| 11.13| 91327| BOLT M612
9.4| 518401| FUEL SWITCH| 11.14| 501139| HIGH-TEMPERATURE INSULATION COTTON
9.5| 95729L| FUEL LINE| 11.15| 94214| FLAT WASHER 10.3×20.6×1.65
9.6| 94412| FUEL LINE CLAMP| 12| 60450010| CO MODULE KIT ASSEMBLY
9.7| 95488L| FUEL HOSE CLIP
Φ12.5×Φ6.2X430MM| 12.1| 599079| CO MODULE
9.8| 518801| FUEL TANK FILTER| 12.2| 92345| SCREW M428
10| 60570016| CARBON CANISTER KIT
ASSEMBLY| 13| 94432| NYLON BRAIDED TUBE
10.1| 90016| NUT M6| 14| 99509| FUNNEL
10.2| 543603L| CARBON CANISTER ASSEMBLY| 15| 511043| CHARGER
10.3| 95121| CARBON CANISTER AND FUEL
TANK CONNECTING PIPE| 16| 99012| SPARK PLUG SLEEVE
10.4| 503034| FUEL LINE CLAMP Φ9.50.8| 17| 99025| WRENCH
10.5| 94411| FUEL LINE CLAMP Φ11×0.8| 18| 99576| OIL BOTTLE ASSEMBLY
11| 60030034| EXHAUST MUFFLER KIT ASSEMBLY| 19| 6629| REMOTE KEY
11.1| 90075| NUT M10*1.5| 20| 517324| HIGH-PRESSURE PIPE
SCHEMATICS
SCHEMATICS
Service Hotline: 855-944-3571
777 Manor Park Drive
Columbus, OH 43228
and Westinghouse are trademarks of Westinghouse Electric Corporation.
Used under license by Westinghouse Outdoor Power Equipment. All Rights
Reserved
WGen12000DFc Rev01
122337 Rev01 4/22
References
- P65warnings.ca.gov
- Westinghouse Outdoor Power Equipment | Westinghouse Outdoor Equipment
- Manuals | Westinghouse Outdoor Equipment
- P65warnings.ca.gov
- Westinghouse Outdoor Power Equipment | Westinghouse Outdoor Equipment
- Warranty Registration | Westinghouse Outdoor Equipment
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>