Technical Specifications
Operating voltage | 220 ~ 240V AC 50/60Hz |
---|---|
Rated load | 400W (Capacitive load) 800W (Resistive load) |
Stand-by power | ≤0.5W |
Sensitivity
| Ceiling mounted height: 3m| 100% / 75% / 50% / 25% / 10%
Ceiling mounted
height: 6m*
| 100% / 75% / 50%
Wall-mounted height: 2m| 100% / 75% / 50% / 25% / 10%
Hold-time| 5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor| 2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency| 5.8 GHz ±75MHz
Transmitting power| 1mW Max.
Detection range| Ceiling mounted height: 3m| 3- 6m (radius )
Wall mounted height: 1.5-2m| 12-15m
Detection angle| 3600 (Ceiling) / 1200 (Wall)
Working temperature| -200 C ~ 600 C
50%, 75%, and 100% detection sensitivity are workable when installed at a 6m mounting height. Only 10% and 25% sensitivity are not able to detect motion signals.
Settings
Sensitivity
Sensitivity can be adjusted by selecting the combination of the DIP switches
for different applications.
Hold-time
Hold-time refers to the time period that the light remains 100% on if no more
movement is detected.
Daylight sensor
Different daylight thresholds can be preset on DIP switches. Light will always
turn on upon movement if the daylight sensor is disabled.
- Disable means the daylight sensor does not work.
- The sensor will turn on the light once motion is detected regardless of the ambient light level.
Troubleshooting
Malfunction Cause Remedy | Cause | Remedy |
---|
The light will not come on
| Incorrect light-control setting selected| Adjust daylight threshold setting
Faulty lamp| Replace lamp
No power supply| Check the power to the sensor
The lamp is always on| Continuous movement in the detection zone| Check the
detection area setting
The lamp is on without any identifiable movement| The sensor is not mounted to
detect movement| Securely mount enclosure
Movement occurred but was not identified by the sensor (Movement behind the
wall, movement of a small object in immediate lamp vicinity etc.)| 1. Reduce
sensitivity.
2. Check the movement behind walls to avoid facilities such as water pipe, and fan, which may mis-trigger the sensor.
The lamp will not work despite movement| Rapid movements are being suppressed to minimize malfunctioning or the detection radius is too small.| Check the detection area setting
Care and Safety
- We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
- For your safety, always switch off the power supply before cleaning.
- For further information, please visit https://www.lighting-info.co.uk/95541
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure the safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
- This light fitting is double insulated and does not require connection to an earth circuit.
- Please read these instructions carefully before commencing any work.
- This unit must be fitted by a competent and qualified electrician.
- Install under the IEE Wiring regulations and current Building Regulations.
- Check the pack and make sure you have all the parts listed.
- To prevent electrocution switch off the mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
- If you are in any doubt, please consult a qualified electrician.
- This light fitting should be connected to a circuit with a 30mA RCD fitted.
- If replacing an existing fitting, make a careful note of the connections.
- Waste electrical products should not be disposed of with household waste.
- Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
Technical data
Supply
- Voltage: 220-240 V~, 50 Hz
- Bulb 95541—-18/14/9W LED module (SMD) CCT, 3000/4000/6000K
- Type: 103936—12/9/6W LED module (SMD) CCT, 3000/4000/6000K
103939—28/24/20W LED module (SMD) CCT, 3000/4000/6000K
This product contains a light source of energy efficiency class D.
SYMBOLS
- Conformity with all relevant UKCA Directive requirements.
- Conformity with all relevant EC Directive requirements.
- The power supply is Double Insulated and does not require connection to an Earth circuit.
- Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
- This product is not suitable for dimming.
- This product is rated at IP65
- This product is rated at IK10 for 95541, 103936. IK10
- This product is rated at IK08 for 103939.
Layout
- Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between each light fitting.
- Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk of being cut, trapped or damaged.
- The main supply cable must have a minimum cross-section area of 1.0mm2.
- Cables must be protected using suitable conduit or plastic trunking.
- The products can be wall or ceiling-mounted. If wall mounting ensure that the power supply is at the bottom.
Installation
- Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.
- Note the switch is turned off before installation.
- The ceiling surface must be flat and smooth to ensure a good fit.
- Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
- Twist and remove the lamp cover from the product, and keep it safe for refitting later.
- Turn the clip to loose the LED tray in the rear casing.
- Using the rear casing as a template mark the position to drill out the fixing holes. Take care to avoid damaging any concealed wiring and pipes.
- Fix the rear casing into the position using the installation plugs and screws.
- Pull the cable through the cable entry hole and seal to maintain the IP rating and wire as detailed Wiring Diagram.
- Refit the LED tray back into the rear casing and lock the clip.
- Twist the lamp cover back onto the product and lock it in place.
- Replace the fuse or circuit breaker and switch it on. Your light is now ready for use.
The wattage is changeable between the different wattage using the wattage switch on the driver before installation.
- For the 103936 is the 12W/9W/6W selectable
- For the 95542 is the 18W/14W/9W selectable
- For the 103939 is the 28W/24W/20W selectable
- The colour is changeable between 3000/4000/6000K using the CCT switch on the driver before installation.
Choose your preferred wattage and colour before installing by wattage switch
or CCT switch on the driver.
Note: Before you change the wattage or colour, please turn off the power
switch for safety.
Product images may vary
Bezels for 95541 only
The following individual casings are available for purchase separately.
- 95545: Chrome plain
- 95546: White eyelid
- 95547: White grill
- 95548: Black plain
- 95549: Black eyelid
- 95550: Black grill
- 95551: Anthracite grey plain
- 95552: Anthracite grey eyelid
- 95553: Anthracite grey grill
Wiring
Having correctly identified the wiring from your existing light fitting, pull the mains wire through the hole and connect to the quick-fit connection block in the following way. No tools are necessary.
Check that…
- You have correctly identified the wires.
- The connections are tight.
- No loose strands have been left out of the connection block.