VEVOR S-U12 MULTI Air Blower User Manual

May 15, 2024
VEVOR

AIR-BLOWER
USER MANUAL
MODEL:
S-U12 MULTI
S-U15 MULTI

S-U12 MULTI Air Blower

Technical Support and E-Warranty Certificate https://www.vevor.com/support
We continue to be committed to provide you tools with competitive price.
“Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and doses not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.
S-U12 MULTI
S-U15 MULTI NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact us:
****CustomerService@vevor.com

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

IMPORTANT SAFEGUARDS

When using electrical appliances, basic safety precautions should always be followed:

**| Warning – To reduce the risk of injury, user must read instructions manual carefully.
---|---
**
| This symbol, placed before a safety comment, indicates a kind of precaution, warning, or danger. Ignoring this warning may lead to an accident. To reduce the risk of injury, fire, or electrocution,
please always follow the recommendation shown below.
| Alternating current
| Correct Disposal of this product:
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

Use Only on GFCI Protected Receptacles:
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: To reduce the risk of fire or electric shock ,do not use this fan with any solid-state speed control device. Prevent sharp and hard objects from dropping into and prevent liquid from flowing into the air-blower, Do not wash the air-blower with liquid, you must first unplug it from power source and then wipe it with wet cloth when you clear it, Do not draw and pull motor leads, and do not bump the air-blower, you’d better use the air-blower between negative five and fifty centigrade, If you let the air-blower be baked in the high temperature, motor leads, enameled cables and heating bodies will aging and shorten its life.
Keep Children Away: Do not allow children to play with or around the unit, in any way, which could result in injury.
DANGER: Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
CAUTION: This product is for use on a nominal 120-V circuit and has a grounding plug similar to the plug illustrated only in a 16A power circuit or more. Only connect the product to an outlet having the same configuration as the plug. Do not use an adapter with this product.
Do not use an extension cord with this air blower. Use only a separate circuit. Do not operate this item in the same circuit as other electrical equipment. It must have its own circuit. Do not modify the plug provided. If it does not fit the outlet, have the proper outlet installed by a qualified electrician. The appliance must be positioned so that the plug is accessible. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person to avoid a hazard.

Protect Power Cord from Damage : Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power supply cord is damaged, it must be replace by a cord of the same type and amperage rating.

TECHNICAL PARAMETER

MODEL S-U12 MULTI S-U15 MULTI
AMPS 10A-11.5A 12A-14A
VOLT. & FREQ. AC110-120V 60Hz AC110-120V 60Hz

OPERATION

Place the air-blower on a steady net surface where children can be kept away. This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug illustrated in sketch (A). Use only with inflatable products. Do not use Sketch (A) in other cases. Make sure that the product is connected to an outlet having the same configuration as the plug. Keep Unit Grounded:This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes
and ordinances.
Conveyance: During conveying the air-blower, you don’t collide and shake seriously; Please prevent sour, alkali, oil and water from entering the air- blower, the air-blower need damp proof.
Storage: Please place it in a dry and ventilated position where it is not sour, alkali, or corrosive gases. After using it outdoors, you should put it in a dry and ventilated room in time. Do not let water into the air-blower.

MAINTENANCE

DANGER!Unplug or disconnect the appliance from the power supply before servicing. When the air-blower have run about half of one year, it need to be maintained, and you should get rid of dust、dirt and the other things on the inlet impeller and in the volute, the source of electrical supply must be disconnected prior to the beginning of any such servicing or cleaning operation.
Clear Motor: Please replace lubricating oil on the bearing regularly. If the bearing has worn down, you may replace it.

TROUBLESHOOTING

PROBLEM CAUSE
Motor won’t run 1.Switch is not turned on.

2.The circuit is opened or it is poor contacted.
3.Electric capacity is damaged.
4.Choked up by hard objects.
Motor runs but wheel makes a scraping noise| 1.The screws tightened on the vaned wheel is loose.
2.There is foreign objects in the air-blower.
Motor is unable to
run normally| 1.The voltage is unstable.
2.Motor is affected with damp.
3.Electric capacity is failure.
4.The impeller is loose.

Printed in China
SWITCH:
LOW END—┃
OFF—O
HIGH END—II
MADE IN CHINA
Technical Support and E-Warranty Certificate www.vevor.com/support

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VEVOR User Manuals

Related Manuals