KING KTW Series Multi Watt Horizontal or Vertical Heater Owner’s Manual

June 4, 2024
KING

KING KTW Series Multi Watt Horizontal or Vertical Heater Owner’s Manual

KTW Series

  • Triple Coil Nichrome Element
  • C-Frame Motor
  • Squirrel Cage Blower
  • Patented Smart Limit Protection
  • 20 Gauge Powder Coated Grill
  • 7 Wattages in one heater
  • Standard Color: Black, (optional almond, white or stainless)
  • Low Profile
  • 120 or 240 volts
  • 2-year limited warranty

Horizontal / Vertical Heater

King introduces another first. The only convertible cabinet heater that can be installed either vertically or horizontally on the market. This narrow profile heater is only 3-5/8” tall and specifically designed to fit into kitchen or bathroom cabinets, providing warm comfortable air for a cold bathrooms or kitchens saving valuable floor and wall space. For application other than kickspace, use the KTW-TG Grill.

Order A’la Carte **To build your own “Complete” select HRC model of proper voltage and KTW-RG grill model of proper color.

STEP 1: Order Heatbox Interior and Recessed Wall Can

Step 1

STEP 2: Order Grill

Step 2

Accessories

Accessories

Engineering Specifications

Contractor shall supply and install, KTW Series limited space forced-air electric heaters, manufactured by King Electrical Mfg. Company. Heaters shall be of the wattage and Voltage as indicated on the plans.

Ratings: Heaters shall be available in wattages of 250 to 1,500 at 120 volts or dual rated from 208 volts to 240 volts.

Blower and Motor: A tangential cylindrical blower, delivering 70 CFM, shall be driven by a shaded pole, permanently lubricated, C-frame type motor with impedance protection and sealed bearings. Motors shall be the same voltage as the heater.

Elements: Element assemblies shall have a 3-wattage element construction of coiled nickel chromium, alloy corrosion resistant wire strung with a minimum of two rows of muscovite insulator. Element assemblies shall have factory provided connection to allow field modification of wattage at time of installation.

Thermal Overload: Heaters shall be equipped with King’s patented thermal overload Smart Limit Protection®, which disconnects elements and motor in the event normal operating temperatures are exceeded. If thermal overload trips due to abnormal operating temperatures, thermal overload shall remain open until manually reset by turning the heater off for fifteen minutes. Automatic reset of thermal overloads, which allow the element to continue to cycle under abnormal conditions, will not be accepted.

Hi/Lo selector switch: Wattage can be adjusted from 250-1250 watts in the low position and 750-1500 watts in the hi position (HLS Optional).

Wall Can: The wall can shall be 20-gauge steel and shall contain two 1/2” knockouts for power leads. The wall can shall be supplied with a factory installed grounding wire.

Grill: The grill shall be louvered, one piece design. The grill shall be epoxy powder coated in the color specified on the plans or stainless steel.

Approval: cULus (E41422)

Dimensional Data – KTW

Dimensional Data

Location for Heater: KTW

This heater has been designed to allow it to be recessed at floor level in the toe space of cabinets or under counters or at the base of walls.

Internal View of the KTW

Internal View of the KTW

Minimum Clearance In Wall, Vertical Installation

When placed in a wall or a filler section of a cabinet.

Mounting Options

Minimum Clearance In Toe Space Installation

When placed in a wall or a filler section of a cabinet.

King Electrical Manufacturing Company / 9131 10th Avenue South, Seattle, WA 98108 / phone 206.762.0400 / fax 206.763.7738 / www.king- electric.com