Lifestyle 505-124 Glass Heater Instruction Manual
- May 15, 2024
- lifestyle
Table of Contents
Lifestyle 505-124 Glass Heater
WARNING: DURING THE PERIOD OF WORKING AND COOLING OF THE APPLIANCE NEVER TOUCH THE GLASS, IT IS VERY HOT.
This product is not suitable for primary heating purposes
FITTING AND OPERATING INSTRUCTIONS
Important advice
Read the instructions in this manual carefully. It has important information
both for operational use and for your safety. Do not start up a faulty device.
Maintenance and repairs to this space heater should be carried outby a
qualified technician. If these instructions are not abided by, there is a risk
of voiding the warranty. This space heater can be installed and started up by
the user following both the fitting instructions as well as the legal
regulations on gas installations in premises designed for domestic use.
However, for added safety, we would recommend that this task be placed in the
expert hands of anauthorized technician. Keep this instruction manual in a
safe place, as it can be useful for reminding you of advice and instructions
and for any other user. If it is lost, do not hesitate to contact your
supplier for another copy.
Safety recommendations
risks of fire or burns and no part should be permanently disassembled. IT DOES NOT FULLY PROTECT CHILDREN OR HANDICAPPED PEOPLE. Do not store or use flammable materials near the space heater. Do not expose the gas cylinder to the full summer heat nor place it too close of any other heat source.
The space heater must not be used in:
- Bedrooms.
- Bathrooms, toilets or showers.
- Basements.
- High-rise buildings.
While in use, ensure that small children remain away from the heater. Always close the gas regulator when the space heater is not in use. Follow the installation instructions carefully. If you smell gas:
- Close the regulator on the gas cylinder.
- Open the windows.
- Do not operate any electrical switch and put out any flame. Notify an authorized technician.Do not use the space heater without the protective screen guard. Verify that the date of flexible gas tube, which you can find in the tube itself, has not expired. Do not move the space heater while in use, as any shocks or blows might activate the safety device.
Installation recommendations
It is important to follow the legal regulations in force, which lay down the specifications for the fiting and start-up of this space heater. We recommend you refer to an authorized technician. However, if you decide not to refer to a technician, the following is a list of the more important conditions required for the premises:
Site conditions
The appliance should not be used in a room the volume of which is less than 60
cbm for living rooms and 31 cbm for other rooms. For ventilation purposes an
area of 100 sq cm to accommodate free movement of airshould be evenly
distributed between upper and lower levels. A safety device is fitted that in
the event of inadequate ventilation being provided the appliance will shut
down until the room has been properly aspirated. We recommend that you do not
use the space heater in situations of frequent use of aerosol sprays.
Connection of the space heater
The space heater can be connected to the gas cylinder by the user without
resorting to a fitter/technician. In order to do so, you should have the
required accessories at hand.
Required accessories (fig.1 and 2)
To operate the space heater you must have:
To operate the space heater you must have:
- Commercially available butane gas cylinder for model 505-124 and bottled only by official distributors.
- Standardized pressure regulator according to the table at the end of the manual. See fig.2.
- Standardized flexible tube for gas with a length of 0.5m.
- Collar clips with screw for the flexible tube (fig.1).
In order to identify these elements, check the type plate and contact your gas distributor. A flexible tube and a pressure regulator must be used for the connection of this device. Contact your gas distributor.
Working description
Depending on the model, your space heater may be fitted with the following elements:
- Key to start-up, light and select the power of the device.
- Protective screen guard.
- Blue flame burner.
- Pilot light window.
- Back panel.
- Fitting lugs for back panel.
- Gas feed coupling.
- Wheels for transport.
Heater start-up
Once the space heater has been taken out of its packaging: Remove the back panel from the device. Connect the flexible tube to the gas inlet coupling of the space heater and to the regulator, ensuring a gastight fit with the collar-clips well screwed down. Avoid twisting the flexible tube. Place the gas cylinder on the baseof the space heater and fit the regulator to the cylinder. After opening the regulator, check that there are no gas leaks by applying soapy water with a paintbrush to the union of the flexible tube with the space heater and the regulator. Fit the back panel using the attached fixing lugs (fig.3).
CAUTION: For their own safety, keep the package (cardboard, Styrofoam, plastic bags, etc.) away from your children.
Note: the replacement of the cylinder should be carried out in a non- flammable environment. The space heater includes a safety device, which turns the device off and extinguishes the pilot flame if the ventilation in the premises is insufficient or the concentration of CO2 exceeds the maximum stipulated by law. It is usual for this device to operate in very small premises. If the flame does go out, ventilate the room well and wait a few minutes before reigniting the space heater.
Ignition instructions
Attention: before using the space heater for the first time and after long periods of non-use, we recommend switching on the control buttons several times alternately and without gas flow to facilitate its operation.The space heater can be regulated to three different heat intensities: MAXIMUM, MEDIUM and MINIMUM. The ignition mechanism is piezo-operated. Open the gas outlet by rotating the lever on the regulator to the correct position (fig.2). Turning on the space heater Press the button and rotate it to your left, holding it down for 20 seconds. Repeat this procedure several times if necessary, until the pilot light ignites near the bottom part of the protective screen guard (where the spark is seen), fig.4 and keep pressing the button for 10 seconds. If, on releasing the button, the flame goes out, please repeat the whole procedure.
- For MINIMUM heat – rotate the button to
- For MEDIUM heat – rotate the button to
- For MAXIMUM heat – rotate the button to
Maintenance
If any anomaly is observed or spare parts are required, contact our Technical Service. The periodical maintenance must be carried out exclusively by an authorized technician. We would recommend that you have a service carried out annually by an authorised technician. Watch the pilot light, which should be stable. Check to see if it is necessary to change the flexible gas tube. If it proves necessary, obtain a new tube and connect it as explained in “Heater start-up”.It is recommended that the cleaning of the space heater be carried out with the gas regulator closed and the heater completely cold, with nonabrasive products. The user must wear protective vegloves to clean the heater. When the space heater is not in use, we recommend storing it in a dust-free atmosphere, protected with a cloth or plastic cover in a dry place.
Warranty
All our space heaters have been meticulously checked before leaving the factory. Nevertheless, if any anomaly is observed remember that our extensive Technical Service network is at your disposal. You should read the section “Before calling in Technical Service” to verify if you can remedy the anomaly yourself.
Before calling in Technical Service
The space heater does not turn on Check to see if there is gas in the cylinder and that the regulator is correctly coupled in the open position. Check to see if the flexible tube is properly connected. Check that the instructions havebeen followed correctly. If this occurs after changing the gas cylinder it may be due to: There is air in the cylinder. Press the ignition button down for alonger period until the pilot flame and burner ignite. Then switch to the MAXIMUM position. The bottle may have been exposed to low outside temperatures. Apply fairly hot wet cloths to the upper part of the bottle to increase gasification and the normal output of gas.
The space heater goes out
If it goes out on completing the ignition instruction, repeat the operation,
followingthe instructions carefully. If it goes out after 30 minutes, it means
that it is operating in a poorly ventilated atmosphere. Ventilate the room and
reignite the space heater. If it goes out before 30 minutes of operation,
ensure that it is not exposed to air drafts or that the cylinder has not run
out of gas.
Model | 505-124 |
---|---|
Power | 3,8 kW |
Injector | 0,70 – 0,70 |
Destiny country | GB / IE |
Category | I3B |
Consumption | 280 g/h |
Type of gas | G30 |
Pressure | 28 mbar |
Norm | EN 449 |
O.D.S. | 21100/304 |
Energy efficiency class |
A
Direct heat output| 3,8 kW
Indirect heat output| 0 kW
Pmin, Minimum heat output|
1,4 kW
Ppilot| 0,17 kW
EEI, Energy efficiency index|
89%
ղth,nom, Useful efficiency at nominal heat output|
100%
| | | |