systemair KVK Insulated Duct Fans Owner’s Manual

May 15, 2024
systemair

systemair KVK Insulated Duct Fans

systemair-KVK-Insulated-Duct-Fans-product

Specifications:

  • Product Name: KVK Slim 160
  • Item Number: #92142
  • Operating Mode: 230V 1~ 50Hz

Product Information

Features:

The KVK Slim 160 is a compact insulated radial fan designed for limited spaces with very low noise levels. It features acoustic and thermal insulation, corrosion resistance, and is suitable for indoor and outdoor installations. The fan is easy to maintain with a service cover.

Flexibility:

The KVK Silent fans are versatile and can be used for supply or extract air in various commercial and domestic applications. They are designed to be installed in any position, offering flexibility in usage.

Performance:

The high-performance impeller and external rotor motor ensure efficient operation, minimizing power consumption while maximizing efficiency for optimal performance.

Certifications:

The construction of the casing and thermal insulation allows for both indoor and outdoor use. The reliable casing and motor construction reduce the need for maintenance, ensuring long continuous operation.

Noise Reduction:

The casing is insulated to reduce noise levels, providing a quieter operation suitable for various environments.

Ecodesign (ErP) Compliant:

The KVK Slim 160 is Ecodesign compliant, meeting energy efficiency standards for environmentally friendly operation.

Usage Instructions

Construction

The casing of KVK fans is made of AluZinc 185 with corrosion class C4. The KVK Slim has an acoustically and thermally insulated lid, while the KVK Silent features insulation in both the lid and casing. Insulation is made of rockwool with a surface liner to prevent fiber migration. The casing includes rubber sealed connection spigots and an external terminal box with IP54 protection class.

Motor Protection:

Fans with AC motors have integrated thermal protection with manual reset for sizes 100-315mm, and prewired thermal contacts for sizes 355-500mm. EC motors have electronic thermal protection including locked-rotor protection and soft- start features.

Impeller:

KVK Slim/Silent fans use backward curved radial impellers made from lightweight, hard-wearing materials. Impellers are dynamically balanced and paired with corresponding external rotor motors for efficient operation.

Motor Type and Control:

Fans come equipped with either AC or high-efficiency EC external rotor motors suitable for both 50Hz and 60Hz operations. EC motors have built-in potentiometers for adjustment and can be controlled externally. AC motors can be controlled by speed regulators. Additional accessories like sensors and controllers allow for demand-controlled operation.

FAQ

Q: Can the KVK Slim 160 be used outdoors?

A: Yes, the construction of the casing and thermal insulation permits outdoor use.

Q: How can I adjust the working point of the EC motor?

A: The EC motor comes with a built-in potentiometer for adjustment or can be controlled by an external signal in the range of 0-10V.

Q: What type of impeller is used in the KVK Slim/Silent fans?

A: The fans use backward curved radial impellers made from durable materials for efficient operation.

KVK Insulated duct fans

Insulated radial fan for limited spaces

  • Design for limited installation height
  • Very low noise, acoustic and thermal insulation Corrosion resistance of casing C4
  • Indoor and outdoor installation
  • Easy maintenance, service cover

Find more details in our online catalogue

  • Flexibility
    The KVK Silent fans combine a high efficient fan and casing with perfect acoustic and thermal insulation capacity. The KVK Silent fans are intended to use for supply or extract air, designed to be installed in any position. This ensures that the fans can be used in a variety of commercial and domestic applications.

  • Reliability
    Construction of casing and thermal insulation
    permits outdoor and indoor use. The combination of reliable casing and motor construction ensures to minimize the need for maintenance of the fans and allows long continuous operation. Thanks to service lid it is easy to clean.

  • Performance
    High performance impeller together with high efficient external rotor motor are designed to ensure high-level performance to minimize power consumption and maximize efficiency.

  • Noise
    Partly or fully insulated casing (depends on model) is perfectly designed to reduce noise mainly to surrounding and partly to inlet/outlet.

Certifications

Features

  • Construction
    Casing of all KVK fans made of AluZinc 185, corrosion class C4.
    KVK Slim has acoustically/thermally insulated lid. KVK Silent has acoustically/thermally insulated lid and casing. Insulation made of rockwool and has surface liner that prevents the migration of fibers into the airstream. Casing has connection spigot with rubber seals and is equipped with an external terminal box with protection class IP54.

  • Motor protection
    Sizes 100-315 mm with AC motors have integrated thermal protection with manual (electrical) reset.
    Sizes 355-500 mm with AC motors have prewired integral thermal contacts TK with leads to external motor protection device.
    Fans with EC motors have an integrated electronic thermal protection, including locked-rotor protection and soft-start.

  • Impeller
    KVK Slim/Silent fans use backward curved radial impeller. These are from lightweight, hard-wearing fiberglass
    reinforced polyamide (for sizes up to 250) or reinforced polypropylene, dynamically balanced and paired with corresponding external rotor motors.

  • Control
    EC motor with built-in potentiometer to adjust working point can be also controlled by external signal 0-10V.
    AC motor can be controlled by 5-step or stepless speed regulator.
    KVK fans can be demand controlled via additional accessories like sensors and controllers for CO2, temperature, humidity, presence indication and VAV.

  • Motor
    Depending on type, fans are equipped with AC or high efficient EC external rotor motors. All motors are suitable for 50Hz and 60Hz.

  • Installation
    KVK Slim/Silent fans can be installed in any position indoor and outdoor. Circular spigot with rubber seals is perfectly designed to connect to the duct by using fast clamps preventing vibration to the duct. A service cover with screw connection and hinges with pins make cleaning and service easy.

Technical parameters

Nominal data|
---|---
Voltage (nominal)| 230| V
Frequency| 50| Hz
Phases| 1~|
Input power| 78| W
Input power kW| 0.078| kW
Input current| 0.346| A
Impeller speed| 2,438| rpm
Air flow| max 0.0778| m³/s
Capacitance of capacitor| 2| µF
Temperature of transported air| max 70| °C
Max temperature of transported air, when speed controlled| 70| °C

systemair-KVK-Insulated-Duct-Fans-fig-8

Performance

Performance curve

systemair-KVK-Insulated-Duct-Fans-fig-9

Hydraulic data|
---|---
Required air flow| 0.08 m³/s
Required static pressure| 275 Pa
Working air flow| 0.08 m³/s
Working static pressure| 275 Pa
Air density| 1.204 kg/m³
Power| 106.4 W
Fan control – RPM| 2,712 rpm
Current| 0.50 A
SFP| 1.398 kW/m³/s
Control voltage| 230.0 V
Supply voltage| 230 V

Sound power level|  | 63| 125| 250| 500| 1k| 2k| 4k| 8k| Total
---|---|---|---|---|---|---|---|---|---|---
Inlet| dB(A)| 53| 63| 64| 61| 58| 56| 56| 53| 69
Outlet| dB(A)| 57| 64| 69| 68| 67| 69| 63| 59| 75
Surrounding| dB(A)| 31| 39| 45| 42| 40| 41| 40| 39| 50
Sound pressure level at 3m (20m² Sabine)| dB(A)| –| –| –| –| –| –| –| –| 43
Sound pressure level at 3m free field| dB(A)| –| –| –| –| –| –| –| –| 29

systemair-KVK-Insulated-Duct-Fans-fig-10

Basic unit|
---|---
ErP compliance| 2016|
SEC Average| -8.8| kWh/(m².a)
SEC Cold| -25.2| kWh/(m².a)
SEC Warm| 0.5| kWh/(m².a)
SEC Class| F|
Unit category| RVU|
Unit type| UVU|
Drive| External MSD or VSD|
Heat recovery type| None|
Temperature ratio (UVU)| Not applicable|
qv max| 428| m³/h
P max| 127| W
Sound power (LWA)| 44| dB(A)
qv ref| 0.083| m³/s
Ps ref| 50| Pa
SPI| 0.265| W/(m³/h)
CTRL| 1|
MISC| 1.1|
x-value| 2|
External Leakage| 5| %
AEC average| 332.1| kWh
AHS Cold| 332.1| kWh
AEC warm| 332.1| kWh
AHS Average| 1,715.2| kWh/a
AHS Cold| 3,355.3| kWh/a
AHS Warm| 775.6| kWh/a
Units with local demand control|  |
---|---|---
ErP compliance| 2018|
SEC Average| -24.8| kWh/(m².a)
SEC Cold| -51.9| kWh/(m².a)
SEC Warm| -9.3| kWh/(m².a)
SEC Class| C|
Unit category| RVU|
Unit type| UVU|
Drive| External MSD or VSD|
Heat recovery type| None|
Temperature ratio (UVU)| Not applicable|
qv max| 427| m³/h
P max| 127| W
Sound power (LWA)| 44| dB(A)
qv ref| 0.0831| m³/s
Ps ref| 50| Pa
SPI| 0.265| W/(m³/h)
CTRL| 0.65|
MISC| 1.1|
x-value| 2|
External Leakage| 5| %
AEC average| 140.3| kWh
AEC cold| 140.3| kWh
AEC warm| 140.3| kWh
AHS Average| 2,830| kWh/a
AHS Cold| 5,536.2| kWh/a
AHS Warm| 1,279.7| kWh/a

Dimension

systemair-92140-KVK-Insulated-Duct-Fans-fig-5

 | A| B| C| D| E| øF| G| H| I| J| K
---|---|---|---|---|---|---|---|---|---|---|---
KVK Slim 100| 400| 150| 392| 325| 278| 98| 348| 300| 69| 76| 300
KVK Slim 125| 400| 150| 392| 325| 278| 123| 348| 300| 84| 72| 300
KVK Slim 160| 400| 185| 392| 325| 278| 158| 348| 300| 99| 90| 370
KVK Slim100 EC| 400| 150| 392| 325| 278| 98| 348| 300| 69| 76| 300
KVK Slim120 EC| 400| 150| 392| 325| 278| 123| 348| 300| 84| 72| 300
KVK Slim160 EC| 400| 185| 392| 325| 278| 158| 348| 300| 99| 90| 370

Wiring

Energy class label

systemair-92140-KVK-Insulated-Duct-Fans-fig-7

Accessories

  • Frequency converter FRQ5SE-6A (37421)
  • RE 1,5 Speed control (5000)
  • REU 1.5 Speed control (5004)
  • SG 160 Protection guard (5608)
  • DTV500A (96807)
  • CB 160-1,2 230V/1 Duct heater (5291)
  • CB 160-2,7 230V/1 Duct heater (5382)
  • CBM 160-2,1 230V/1 Duct heater (5482)
  • CWK 160-3-2,5 Duct cooler,circ (30022)
  • FGR 160 Filter cassette (1809)
  • LDC 160-300 Silencer (53108)
  • LDC 160-900 Silencer (5193)
  • VBC 160-2 Water heating batt (5458)
  • VBF 160 Water heating battery (1731)
  • IGK-160 Wall Grid (1632)
  • REE 1 Speed control (5314)
  • REV-3POL/03-7,5kW R/Y (33978)
  • VKK-160 Back draft damper (1625)
  • Frequency converter FRQSE-6A (37419)
  • CB 160-2,1 230V/1 Duct heater (5292)
  • CB 160-5,0 400V/2 Duct heater (5383)
  • CBMF 160-2,1 230V/1 Duct heate (12244)
  • FFR 160 Filter cassette (1770)
  • FK 160 Fast clamp (1610)
  • LDC 160-600 Silencer (5192)
  • RSK-160 Back draft damper (5601)
  • VBC 160-3 Water heating batt (9840)

Documents

INSTALLATIONOPERATION_AND_MAINTENANCE_INSTRUCTION_KV_DUO__KVK_DUOKVK_003EN.PDF COMMISSIONING_RECORD_FANSEN.PDF

Article name: KVK Slim 100 | Product link: https://shop.systemair.com/en- GB/productPermalink?p=400493 | Item Number: 92140 | Variant: 230V 1~ 50Hz | Document type: Product card | Created at: 26.02.2024 | Generated by: Systemair Online Catalogue | Language: English

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals