OZOTECH AIM 20 Ozone Generator User Manual
- June 14, 2024
- OZOTECH
Table of Contents
Ozone Generators
AIM 20 Ozone Generator
Operation & Maintenance Manual
OZOTECH, Inc. • 1015 South Main Street, Yreka, CA 96097 • Ph. 530.842.4189 • ozotech.com
Caution
Read the following safety guidelines thoroughly before attempting to operate or install your equipment:
- As with all electrical devices, this equipment should never be allowed to come in contact with water.
- Only qualified personnel should be allowed to set up, maintain and operate this equipment.
- The equipment must be operated using a properly grounded electrical circuit.
- OZOTECH assumes no liability for damages or injuries incurred by misuse of this product.
- Do not use an extension cord to supply power to this equipment.
- Use a power conditioner if line voltage fluctuates outside of specified range.
- Unit must never be run with internal air flow rate below manufacturer’s specifications.
- Unit must be disconnected from power prior to performing service or repair.
Theory of Operation
Your AIM 20 ozone generator is a state-of-the-art device designed to produce significant concentrations of high-purity ozone by means of our proprietary Advanced Impedance Management technology, “AIM”. The technology utilized by OZOTECH to generate ozone is known as “Cold Plasma Corona Discharge”.
2.1 Cold Plasma Corona Discharge Ozone Generation
Cold plasma corona discharge generators create ozone through the action of
extremely high voltage, low current electrical “arcs” across an air space.
When oxygen (O2) is passed through the air space, some molecules are split,
resulting in “free” oxygen atoms which quickly attach themselves to intact O2
molecules. The result is a very unstable form of oxygen, O3 (ozone). It is the
extra atom of oxygen that gives ozone its superior oxidation capabilities.
As opposed to plate-type or open-air dielectric corona discharge generators,
cold plasma corona discharge utilizes a cell filled with proprietary gases.
The cell (or cells) are then surrounded by a perforated stainless steel grid,
connected to earth ground. When high voltage is applied to the cell, an
electrical arc, called “corona” is formed between the cell and the grid.
Each cell/grid combination is separately housed within its own holding chamber
(manifold). All air drawn through the manifold is channeled directly through
the corona. This design surpasses plate-type corona discharge designs by
constantly exposing a fresh supply of oxygen molecules to the corona, and by
keeping the cell and manifold cool. Recent improvements in the design have led
to a method of producing ozone wherein the cell is: 1) Capable of withstanding
high valtage inputs without plating; 2) No relative expansion and contraction
of the parts; 3) Able to operate at lower temperatures than conventional
corona discharge generators thus improving reliability and efficiency without
the need for separate cooling water circuitry; 4) Maximum ozone output with
minimum high voltage input.
Operating Conditions
Your AIM 20 ozone generator requires special operating conditions in order to maintain performance and reliability. Warranty coverage of your equipment is contingent upon strict compliance with the operating conditions specified in this manual.
3.1 Operating Environment
EXTERNAL
Choose a location for your equipment that is clean, dry, and free of excessive
airborne particles. Your equipment requires a constant flow of clean air for
proper internal cooling. A minimum of six (6) inches clearance is required
around the front, bottom, left and right side of the unit to eliminate
restriction of air flow. Direct exposure to moisture must be avoided. The AIM
20 ozone generator chassis is designed to be drip-proof. It is not water-
tight.
Mount your AIM 20 ozone generator in the best possible operating environment
available at your installation site.
INTERNAL
The operating environment inside the chassis is also important.
Maintaining a clean, dry unit will increase overall performance and extend
service life. A common cause of failure is un-contained corona (electrical
arcs) within the chassis environment.
Moisture and dust are facilitators of this condition. They both help set up a
“path” for the corona to develop and follow. Once established, corona usually
does not stop until it has become severe enough to cause catastrophic failure
of the corona discharge cell or manifold, and subsequently blows the fuse.
Note: If this condition develops, contact manufacturer.
3.2. Internal Air Flow Specifications
As mentioned in the Theory of Operation section 4.0, cold plasma corona
discharge relies upon a flow of air passing between the corona discharge cell
and the perforated grid to produce ozone and keep the corona cell and manifold
cool.
The rate at which air is drawn (or forced) through the ozone generator is user
adjustable. You may fine tune the flow rate to best suit your specific
application.
However, in no case should the air flow rate be allowed to drop below the
minimum values specified below. Failure to provide minimum air flow rates may
allow your ozone generator to develop too much heat, possibly leading to
equipment failure.
Model
AIM20
Minimum Air Flow Rate in Standard Cubic Feet per Hour (SCFH)
3.3. Preparation of Input Air
Regardless of the method of ozone generation, properly preparing the input air
(feed gas) will pay huge dividends in performance and reliability. OZOTECH
does not recommend the use of any AIM series ozone generator without air
preparation. Warranty coverage of your ozone generator is contingent upon
operation with air preparation equipment.
The key to air preparation is in the removal of Hydrogen (H) and Nitrogen (N)
found in ambient air. When atoms of Hydrogen and Nitrogen are subject to
corona discharge (cold spark or otherwise), by-products such as Nitrous acid
(HNO2) and Nitric acid (HNO3) are formed. The formation of these compounds
inhibits performance and increases the frequency of maintenance.
To understand how performance is affected, we must recall from the Theory of
Operation section that ozone is created by splitting an oxygen molecule (O2),
and then joining the liberated oxygen atoms (O3) with intact oxygen molecules.
Imagine that in addition to oxygen molecules, your feed gas also contains
Hydrogen and Nitrogen atoms.
After being subjected to corona, some of the Hydrogen and Nitrogen atoms will
attach themselves to intact oxygen molecules, forming HNO3, or Nitric acid.
Others will attach themselves to ozone molecules, forming HNO2, or Nitrous
acid. It is the formation of these compounds that reduces performance
potential. It is simple to understand why. If ozone molecules were not being
“used” by Hydrogen and Nitrogen in the formation of acids, more would be
available to be used in oxidation. Likewise, if oxygen molecules were not
“used” to form acids, they would be available for the creation of more ozone.
Increased service life and reduction in maintenance are gained due to the same
principle. With less HNO2, and HNO3, being formed, corona discharge cell
maintenance, or cleaning the cell, can be reduced without the risk of acid
buildup. Since both HNO2, and HNO3, are highly conductive, they are capable of
producing a path for corona (electrical arcs) outside of the corona discharge
cell and manifold. As stated previously, once an arc has started, catastrophic
failure is the usual result.
3.3 Preparation of Input Air Cont.
Your AIM 20 ozone generator is capable of operating with either negative
pressure or positive pressure air preparation devices. Negative pressure
devices, such as heat-regenerated desiccant air dryers rely upon the action of
the venturi injector to draw air through the generator (and the dryer).
This method is typically not utilized with the AIM series, due to the
difficulties of meeting minimum air flow requirements through the vacuum
action of a venturi injector alone. Positive pressure devices, such as the
Power Prep Series manufactured by OZOTECH, utilize an internal air compressor
to push prepared air through the generator. This method is utilized in the
majority of AIM 20 applications.
Your AIM 20 is designed for not more than 5 psi of internal pressure.
3.4 Input Power Requirements
OZOTECH offers the AIM series in a variety of configurations to accommodate a
wide range of world supply voltages and frequencies. Refer to voltage label on
the side of the unit for specific voltage and frequency requirements.
It is extremely important that your equipment is provided with the appropriate
operating power source. Most supply voltages fluctuate, so it is necessary to
monitor your voltage and assure it is within acceptable variance values listed
below.
Voltage = (Specified) +/- 5%
Frequency = (Specified) +/- 5%
Power Consumption, AIM 20 = Nominally 200 Watts (50/60Hz)
Note: If your line voltage fluctuates beyond acceptable variance, it will be necessary to connect your equipment to a line conditioner.
Maintenance
The AIM 20 is designed and delivered for maximum efficiency and long life. No
adjustments, other than fine-tuning the air flow rate to match user-specific
requirements, should be made by the end user. Simple maintenance and
appropriate operating conditions are the only requirements to keep the unit
functioning within manufacturer’s specifications.
Performing any other modifications or adjustments to internal components will
cause the unit to function outside of manufacturer’s specifications, and will
cause damage to the unit not covered under terms of warranty. Maintenance
should only be performed by qualified individuals. Your ozone generator
operates under conditions of high voltage; maintenance personnel should be
trained in electrical safety.
4.1 Corona Discharge Cell Maintenance
Corona discharge cell maintenance is simply a matter of keeping the cells
clean and ensuring the O-Ring seat is in good condition.
You will have either (2) cells to maintain. OZOTECH has designed a cell-to-
chamber interface that restricts the corona discharge to only the stainless
steel manifold, thereby reducing any possibility of catastrophic failure due
to heat or high voltage arcing.
Frequency of Maintenance: Every 4800 hours (6 months)
To Maintain the Corona Discharge Cells:
- Disconnect unit from power source. Allow generator and room to clear of ozone gas.
- Loosen the (4) screws securing the chassis lid and remove the lid assembly.
- Locate the High Voltage Wires connected to the top of each Corona Discharge Cell. Pay close attention to the wire routing.
It will be necessary to route in the same manner when maintenance is complete.
Note: In any case, wires must be routed so that a minimum clearance of 1 inch is provided between wire and chassis (or metal parts attached to chassis).
4.1 Corona Discharge Cell Maintenance Cont.
-
Unplug the high voltage wires from the top of each corona discharge cell to their mating transformer wire. (See Figure 1)
-
Carefully loosen and remove each of the aluminum stand-offs that secure the caps onto the manifold. (See Figure 2)
-
Very carefully pull each CD cell cap, then the CD cell itself, straight out of the manifold assembly. Your corona discharge cells are made of glass, so extreme care must be taken to avoid breakage!
-
Clean the entire cell (glass as well as cap) with glass cleaner, or soap and water. DRY THOROUGHLY.
Note: Replacing a wet cell will cause damage to the unit. -
Install corona discharge cells by reversing the above steps. Route high voltage wires as close to original routing as possible, as shown in Figure 3. The object is to separate these wires from sources of ground, such as the chassis, and low voltage (115 or 230V) components.
-
Pressure check your unit. With the unit powered down and supplying a source of positive pressure, open the airflow meters until the indicating ball reaches the top of the scale.
Remove the ozone delivery tubing from the venturi injector inlet (or equivalent) and seal to begin to pressurize the generator and ozone delivery tubing. Using a suitable leak check solution (available through your OZOTECH dealer) check for leaks at the tube/chamber interface, tubing connections, etc. Immediately correct any leaks prior to placing your unit back in service.
Figure 1 – CD Cell Interface, (Component Descriptions)
Figure 2 – CD Cell Cap Removal & Installation
Figure 3 – CD Cell & Manifold Component Layout
4.2 Intake Filter Maintenance
The intake filter is located on the side of the chassis, Figure 10.
This filter removes dust particles from the air drawn into the chassis. Proper
cooling of internal components requires filters to be clean, dry and intact.
Frequency of Maintenance
- Every 2400 hours (3 months)
To Clean Intake Filter
-
The filter retaining ring snaps into grooves in the fan guard.
Remove filter retaining ring by gently pulling on one side. -
Remove filter media. Wash gently in soap and water. Dry thoroughly. Inspect for tears, holes, etc. If filter is intact, replace by reversing Step 1.
Note: Depending on the severity of your specific environment, it may be necessary to increase frequency of maintenance.
Frequency of Replacement
- Every 4800 hours (6 months)
To Replace Intake Filter
Replacement procedure is identical to maintenance procedure.
Note: Depending on the severity of your specific environment, it may be
necessary to increase frequency of maintenance.
4.3 Chassis Maintenance
Proper maintenance of your generator chassis will provide more than aesthetic advantages. Dust and moisture can contribute to a path for electrical arcs. A clean internal environment will reduce the likelihood of corona outside of the corona cell and manifold.
Frequency of Maintenance
- Every 2400 hours (3 months)
To Maintain Chassis
- Disconnect unit from power source.
- Remove chassis lid and access cover.
- Using a clean, dry cloth, carefully wipe off inside of chassis and all internal components. Make certain that the tops of the corona cell(s), the “face” of the transformer, and the highs voltage wire(s) are thoroughly cleaned.
- Using a damp cloth, clean the outside of the unit. A mild detergent may be used.
- Thoroughly dry chassis, inside and out.
4.4 Check Valve Replacement
Protecting your ozone generator from water infiltration is vital. Ozone
generators will fail if water is allowed to enter the corona region. Water
infiltration can be avoided by proper installation and maintenance of a back-
flow prevention device between the ozone generator “ozone outlet” and the
venturi injector (or diffuser).
We strongly suggest that the check valve is closely inspected as often as
possible, such as each time maintenance of any type is performed. If water is
visible between the check valve and the ozone generator, cracks are visible in
the check valve body, or foreign matter has built up on the internal O-ring,
replacement should be performed immediately, regardless of elapsed time since
last replacement.
Required replacement schedule is listed below, and must be performed on
schedule, even if the check valve appears sound.
Frequency of Replacement
- Every 3 months
To Replace Check Valve
- Disconnect unit from power source. Allow the ozone generator to clear of ozone gas.
- Remove tubing from hose adapter on each end of the check valve.
- Trim approximately one inch from the end of each tube, to remove distortion caused by the hose adapter.
- Place new check valve assembly in-line, between ozone generator and venturi injector. Check valve flow direction must point toward venturi.
- Secure the tubing onto barbs by installing snapper clamps.
- Reference Fig. 5 for check valve installation detail.
Figure 4 – Check Valve Assembly, (Detail)
Figure 5 – Check Valve Installation, (Detail)
Fusing
There is only one fuse, connected to the live source conductor and accessible from the outside of the chassis. The figure below illustrates location of this fuse. Fuse size and value is listed below:
Model # AIM 20
115/230 Vac Models
Fuse Size
5mmx20mm
Fuse Value
3.15AmpSlowBlow, IEC127
FIGURE 6 – Fuse Location(Left Side Chassis Component Details)
FIGURE 7 – Mounting Hole Locations
Spare/Replacement Parts
(*) Denotes recommended spare maintenance parts with initial purchase.
Followed by quantity, per unit, recommended for one year’s scheduled
maintenance.
(*) Denotes recommended spare parts for purchases outside of the Continental
U.S. or for applications where it is necessary to eliminate potential down
time (i.e., bottled water stores). Items marked with this symbol should be
purchased in addition to those marked with () symbol.
Part # | Description | Applicable Model |
---|---|---|
40045-08 | Corona Discharge Cell |
Interface upgrade assembly
Cells may be replaced individually| All models
Qty = (2), AIM 20
40155| Corona Discharge Cell| All models
40147-P| High Voltage Transformer| 115Vac Models
115Vac Primary
40147-01-P| High Voltage Transformer| 230Vac Models
230Vac Primary
33241| Manifold Assembly, Single| All models
Qty = (2), AIM 20
| Manifold Assemblies may be replaced individually.
31037| Flowmeter,0-20SCFH| All models
43002| Indicator light| 115Vac Models
43132| Indicator light| 230Vac Models
40002| Fan| 115Vac Models
40087| Fan| 230Vac Models
40013| Fan Guard| All models
38097| Filter Media(Qty=5)| All models
44344| O-Ring, Viton| All models
Qty = (1) per corona discharge cell.
O-ring provides seal between cell and manifold.
43230| Fuse, 3.15A S.B., IEC127| All models
Qty = (1) for 115VAC,
Qty = (2) for 230VAC
44347-1| Tension Retainer Assembly| All models
45264-02| CD Cell Cap assy.| All models
47018-304| Check Valve, ½#* (Qty = 1)| All models; included
in accessory packet
44134| Snapper Clamp#4| All models
44140| Tubing,Tygon1/4”I.d.x3/8”O.d.| All models
44144| Snapper Clamp,#2| All models
44244| Tubing, Tygon /4”I.d.x7/16”O.d.| All models
40151| AIM Driver| 115Vac Models
40152| AIM Driver| 230Vac Models
Note: Spare parts are listed for only the most commonly purchased models. For options not included in this section, consult your dealer.
Troubleshooting Guide
Troubleshooting should be performed by a qualified electrician, in accordance with sound electrical safety practices.
Symptom | Possible Cause | Remedy |
---|
Indicator light does
not turn on.| Unit is not connected to a power source or is connected to
improper power source.| Refer to label on side of chassis for voltage/
frequency requirements.
Connect unit to proper power source.
Safety Interlock switch is not engaged by chassis lid.| Remove lid. Bend “up”
interlock arm.
Blown fuse| Visually inspect unit and compare to wiring diagram. Inspect
Corona Discharge Cell for damage. Inspect wire from high voltage transformer
to corona discharge cell for disconnection or burn marks. Repair any and all
problems prior to placing unit in service or contact factory for service
information.
| Light is not receiving power.| Connect light leads to power source per
wiring diagram.
| Light has failed.| Refer to spare/replacement parts for replacement part
information.
Unit keeps blowing fuses| Electrical short circuit| Visually inspect unit, and
check for loose connections. Inspect printed circuit board for burn marks.
Inspect HV wire from printed circuit board to ozone cell for disconnection or
burn marks. Repair any and all problems prior to placing unit in service or
contact factory for service information.
Incorrect fuse value and type are being used.| Replace with appropriate
size/type fuse. Refer to spare/replacement parts for replacement part
information.
Unit is connected to improper power source.| Refer to label on side of chassis
for voltage/ frequency requirements.
Corona discharge cells were not installed.| Install per installation manual.
(Corona discharge cells are shipped in a separate container to avoid damage).
Corona outside of the cell/manifold has established due to dirt or moisture
within chassis. Corona discharge cell is in need of maintenance.| Perform
corona discharge cell maintenance and chassis maintenance in accordance with
this manual.
Unit does not
produce adequate concentration of ozone.| Air flow rate is too high.| Adjust
air flow meter to lower setting, within range specified in air flow
specification section of this manual.
Unit is running too
hot due to insufficient cooling air flow.| Refer to air flow specification
section of this manual.
Unit is connected to improper power source.| Refer to label on side of chassis
for voltage/ frequency requirements.
Unit does not produce adequate concentration of ozone, even with
air flow rate set at levels that previously produced adequate ozone
concentration.| Corona Discharge Cells require maintenance.| Refer to corona
discharge cell maintenance section of this manual.
Air preparation device is not functioning at prior level of performance.|
Inspect/maintain air preparation equipment in accordance with manufacturer
recommendations.
Standards
The transformer(s) in this unit are manufactured and tested (as applicable) to
the following standards.
High voltage transformer, all models
(Part No. 40141) Underwriters Laboratories E176017
Limited Warranty
OZOTECH, Inc., warrants the AIM 20 ozone generator to be free from defects in parts and workmanship for (12) months from date of invoice, under conditions of normal use. The corona discharge cell is warrantied against catastrophic electrical failure for 3 years from date of invoice. All other parts, repaired or replaced, will be warranted only for the remainder of the original warranty period.
OZOTECH, Incorporated will refund the purchase price, perform repairs or
replace equipment, at the option of OZOTECH, Incorporated.
The warranty shall be null, void, and non-binding upon OZOTECH, Incorporated
if OZOTECH, Incorporated (or authorized service center) determines the cause
of malfunction or defect to be a result of:
- Failure to perform proper maintenance as defined and recommended in this manual.
- Failure to adhere to and provide proper operating conditions, as defined in this manual, including operation outside of temperature range, operating in wet or dirty environment, operation outside of manufacturer’s specifications.
- Adjustments made by user other than product output flow rate within ranges specified by manufacturer.
OZOTECH, Incorporated assumes no liability for damages incurred by deliberate
or incidental misuse of this product, or damages incurred in transit.
Read Limited Product Warranty>Link
Service Returns
If the need arises to return your equipment for service, the following procedure must be followed to ensure accurate and timely processing of repairs:
- Obtain the serial number of unit to be returned.
- Obtain model number/name of unit to be returned.
- Contact OZOTECH and request a Return Material Authorization (RMA) form. Make sure to give the factory representative an accurate and current shipping address.
- Enclose a description detailing the problem with the unit. Be as specific as possible.
- After receipt of RMA form, package unit for shipment. Enclose the RMA form with the unit. Use the original packaging materials if possible.
- Clearly write the RMA number on the outside of the shipping package.
- Verify that the address is correct and current.
- Shipments that are not factory authorized will be refused.
It is recommended that you ship with a reputable and reliable shipping company, and that the contents of the package are insured. OZOTECH accepts no responsibility for damage or loss of equipment in transit.
ALL FREIGHT CHARGES INTO THE FACTORY MUST BE PREPAID. If the repair is covered under warranty, the factory will pay return shipping charges (surface rates only) to the address listed on the RMA, within the Continental United States. If the repair is not covered under warranty, the returning party is responsible for payment of return shipping and handling charges, as well as labor and equipment costs associated with the repair.