MEAN-WELL PLD-25 Series 25W Single Output LED Power Supply
Features:
- Universal AC input / Full range (up to 295VAC)
- Built-in active PFC function
- Constant current design
- Protections: Short circuit / Over temperature
- Cooling by free air convection
- Fully isolated plastic case
- Class 2 Power Unit
- Class Il power unit, no FG
- IP42 design
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)
- 100% full load burn-in test
- Low cost
- High reliability
- Suitable for dry / damp locations
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| PLD-25-350| PLD-25-700| PLD-25-1050|
PLD-25-1400
---|---|---|---|---
OUTPUT| RATED CURRENT| 350mA| 700mA| 1050mA| 1400mA
OPERATING VOLTAGE RANGE| 40 ~ 58V| 24 ~ 36V| 16 ~ 24V| 12 ~ 18V
CURRENT ACCURACY| ±5.0%
RATED POWER| 20.3W| 25.2W| 25.2W| 25.2W
RIPPLE & NOISE (max.) **Note.1| 4.6Vp-p| 2.7Vp-p| 2.2Vp-p| 2Vp-p
NO LOAD OUTPUT VOLTAGE (max.)| 60V| 50V| 35V| 25V
SETUP TIME| 500ms / 230VAC 2000ms / 115VAC at full load
INPUT| VOLTAGE RANGE| 90 ~ 295VAC 127 ~ 417VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at
full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION| THD< 20% when output loading≧70% at
115VAC/230VAC input and output loading≧80% at 277VAC input
EFFICIENCY (Typ.)| 85%| 86%| 85%| 84%
AC CURRENT (Typ.)| 0.6A/115VAC 0.3A/230VAC 0.2A/277VAC
INRUSH CURRENT (Typ.)| COLD START 25A(width=75μs measured at 50% Ipeak)
at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 72 units (circuit breaker of
type B) / 80 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.5mA / 240VAC
PROTECTION| SHORT CIRCUIT| Hiccup mode, recovers automatically
after fault condition is removed.
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750, CSA C22.2 No. 250.0-08,
ENEC BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, BS EN/EN 62384, EAC TP
TC 004, IP42 approved ; design refer to UL60950-1
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C
(≦75% load) ; BS EN/EN 61000-3-3, FCC part 18 non-consumer equipment, EAC TP
TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55024,BS EN/EN61547, light industry level, EAC TP TC 020
OTHERS| MTBF| 5524.2K hrs min. Telcordia SR-332 (Bellcore) ;
968.2Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 845729.5mm (LWH)
PACKING| 0.19Kg; 72pcs/14.7Kg/0.75CUFT
NOTE**|
- Ripple & noise are measured at 20 MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
- Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- The ambient temperature derating of 3.5°CY1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- For any application note and IP waterproof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Case No.PCD16A
Unit:mm
Block Diagram
fosc: 90KHz(115VAC) 120KHz(230VAC)
Derating Curve
Static Characteristics
Power Factor Characteristic
EFFICIENCY vs LOAD (PLD-25-700)
PLD-25 series possess superior working efficiency that up to 86% can be
reached in field applications.
Customer Support
User Manual
File Name:PLD-25-SPEC 2023-04-14
Downloaded from Arrow.com.
Read User Manual Online (PDF format)