SHIHOT 6211 Ceiling Fan Light User Manual
- May 15, 2024
- SHIHOT
Table of Contents
SHIHOT 6211 Ceiling Fan Light
FAN LIGHT AND GOOD LIFE
- Model No.: 6211
- Voltage : 120V~, 60Hz
- Motor Power : Max. 35W
- Light kit : 4*E26 4W
Thanks and safety precautions
The ceiling fan you purchased will provide comfort and performance in your home or office for many years. This instruction manual contains complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
Safety Precautions
The information contained in the following pages has been prepared to ensure
the maximum enjoyment of your fan. Please remove the fuse or turn off the
circuit breaker to cut off the power before installing the fan. Ensure all
electrical connections comply with local laws, regulations, and national
electrical codes. If you are not familiar with electrical installation and
wiring, please hire a qualified electrician or consult the wiring manual :
- For your safety, all electrical connections and disconnections should be performed by a qualified electrician.
- Any action performed for the electrical connection of the device must be carried out after ensuring that the general power supply is disconnected, by removing the corresponding fuse or disarming the protective switch to ensure total isolation of the power supply.
- When deciding where to mount the fan, be sure that there is at least 30 inches(76 cm) of space between the fan and any wall or other obstruction that the fan blades could collide with. The greater this distance, the more effective the airflow produced. After the fan is mounted, be sure that the blades are no less than 7ft(2.1m) above the ground.
- The anchor point for the fan must be able to support a weight of at least 100 pounds(45 kg). If mounting on a ceiling junction box, be sure that the fan is adequately supported to prevent loosening or turning.
- The fan’s electrical connection must be “grounded” (the fan’s ground cable connected to the installation’s grounding network) to avoid any branching that may be dangerous to people.
- Do not connect the fan’s power supply to any dimmers, potentiometers, or light switches, as it will cause the fan to malfunction and/or damage the motor. The fan must be directly connected to a properly protected installation circuit (magnetothermal differential switch with adequate size for the fan’s consumption and technical specifications). Only use the fan’s control to turn it on or stop it.
- It is recommended to not use these types of fans along with gas installations simultaneously in the same room.
- The fan must not be moving and must have come to a complete stop before changing its direction of rotation. This will prevent damage to its motor and to the control unit, when applicable.
- Do not insert anything that could hit the fan’s blades into its pathway while it is moving, as this could cause damage to people, damage the blades, and offset the balance of the unit, causing vibrations and wobbling.
- After installing the fan, ensure that all fastenings are secure and tightened to avoid any noise caused by loose elements.
- Due to the fan’s movement, certain fastenings may become loose. Check all fastenings twice per year at a minimum to ensure that they are sufficiently tight. If necessary, they must be retightened.
- The motor housing can be cleaned with a soft brush or a lint-free cloth to avoid scratching the surface. Clean the blades with a lint-free cloth. Important: Turn off the main power supply before starting any maintenance. Do not clean the fans with water or a damp cloth.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Preparation
- Tapping screw
- Plastic anchors
- Round hanging plate
- Lighting and fan
- Remote control
- 26 Light source
Warning
- Failure to disconnect the power supply prior to installation may result in serious injury or death. For a full description of the precautionary measures and warnings, please see the safety precautions page.
Installation of light source
Suspension
Install the Ceiling Plate
- Choose the following installation methods according to the actual situation of the roof.
- Drill holes with electric drill (8 mm)
- Use expansion screws to fix the mounting bracket to the ceiling.
* Fasten the mounting bracket to the ceiling with self-tapping screws.
Wiring
-
Connection.
-
Connect the yellow, gray, and whitewire ports with the corresponding colors of the drive.
-
Connect the red, black, and white reports with the corresponding color of the drive.
-
Connect the live line and zero line of the drive to the power supply.
-
Install the lamp body and screw it onto the suction cup
Try to position the wiring terminals on the suction cup in different directions from the driver -
Turn on the power
-
Test the fan and lighting.
Remote control ( Emitter ) operation
- Please click the picture below to install the remote control battery. Select dimmer switch or variable speed wall control wil damage the fan. whether to install a remote control wall mount
This remote is pre-programmed from the factory and should work right out of the box once the battery is installed. Should, for any reason, reprogramming be needed, please follow the syncing process as follows
SYNCING INSTRUCTIONS: Turn off the main power, then turn it back on. Within 30 seconds.- press and hold the high and low-speed buttons on the remote at the same time for 5 seconds. The LED indicator will fash 3 times, signaling a successful synchronization. Once complete, the fan will start on the low speed with the light (if applicable) off.
ATTENTION! Do NOT use this fan with a dimmer switch or variable speed wall control. Using a Please click the picture below to install the remote control battery. Select dimmer switch or variable speed wall control wil damage the fan.
Troubleshooting
WARNING
For your own safety tum off power at fuse box or circuit breaker before
troubleshooting.
Cleaning and maintenance
Dear Customer : This product from the date of purchase, a free warranty 1 year. If the product has been misused, damaged by accident or in any other way of improper use, this warranty becomes void. If you have any problem in using the product, please feel free to contact us, the after-sales email address is: deanfluenza11za@gmail.com Your satisfaction is our purpose of service.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>