BHP-8000 C Room Thermostat
Technical date
Power Supply | 24VDC/AC +10% |
---|---|
Current Load | 1A (Inductive) 3A (Resistance) |
Sensor | NTC3950, 10K |
Set Temp. Range | 42-122 ℉ (5~50℃) |
Accuracy | ±1 F |
Display Temp. Range | 41~210 ℉ (5~99℃) |
Ambient Temp | 32~113 ℉ (0~45℃) |
Ambient Humidity | 5~95%RH(Non Condensing) |
Storage Temp | 23~113℉ (-5~45℃) |
Timing Error | <1% |
Power Consumption | <1.5W |
Shell Material | PC+ABS(Fireproof) |
Available Installation 1 | Wall mounted |
Available Iallation 2 | Distance of 62±5mm |
(Europe, China and Japan)
Available Itallation 3| Hole Distance of 86±3mm
(USA and Italy etc,)
Wire Terminals| Wire 2×1.5mm2 or 1×2.5mm2
Protection Class| IP20
Buttons| Capactive Touch Buttons
More settings
Service
Your thermostat carries an 24 months warranty from date of purchase. Service
outwith the warranty period mayincur a charge. More detail please contact with
us directly.
Welcome
Thank you for your purchase.
Your new thermostat will provide uniform and comfortable temperature Control
throughout every room in your peoperty.
We bring together technology craftsmanship and the highest quality materials
to provide you with a safe, reliable productcombined with sleek, contemporary
design. Please read this installation/programming manual for comprehensive
instructions on installing and operating your thermostat.
Please also ensure a suitably qualified person installs your thermostat and
complies with all local regulations.
In The Box
Thermostat *1; | Marking tape *1; | Screws *4; |
---|---|---|
Power Module *1; | QC Passed *1; | User Guide *1; |
CAUTION
-
Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry.
Disconnect power supply before installation. -
Check whether the power supply is 24V, if it is 95-220V, Thermostat can’t be used.
Dimension
Unit:mm( inch)
APP operation interface description (Heat pump thermostat)
Syetem mode:Display the current system mode.tap it to swich the mode.
Fan mode: Display the current fan mode. Tap it to swich the mode.
Hold mode: Display’s the current hold mode,Tap it to swich the mode.
Targe temperture: Turn up/down the target temperature.
Setting:You can edit the setting of device, such as Schedule,Holiday mode,fan
run time etc.
After connecting to this hotspot, return to the “smartlife” APP
Main Page
-
System
-
Fan
-
Menu
-
Touch Button
-
Screen
AP Mode
Press and hold until the icon of the thermostat slowly blinks (if the icon is
blinking quickly, press and hold until the wifi icon slowly blinks), then
follow the following figure (Fig. 2.11- Fig. 2.16). Method 3: Ordinary distribution
network guidance (Fig. 2. 1&Fig. 2.5.1)
Network distribution mode:
EZ Mode
Press and hold the “ “until the thermostat screen flashes quickly and displays
the “ ” icon, and then operate according to the following figure (Fig 2.6-Fig
2.10).
Installation
-
Power off,remove the old thermostat.
Note: Do not remove the wall plate;
-
Take a picture of your old thermostat wires how to connect to the terminal;
-
Label the wires with Tags;
-
Please confirm old thermostat if have C wiring(Blue line)
Yes → Plan A
No → Plan B
Terminal designation
Terminals
|
What it means
---|---
Rh| 24VAC primary for heating
Re| 24VAC primary for cooling
C| 24VAC Common Wire
W1| Heat Relay (Stage 1)
W2| Heat Relay (Stage 2)
Y1| Compress Relay (Stage 1)
Y2| Compress Relay (Stage 2)
G| Fan Relay
0/B| Heat Pump Changeover Valve
S| Optional wiring module terminal to combine Y and G, while reserve an extra
in-wall wire to power on the thermostat
Method 2: Scan the QR code to configure the network guide ( Fig 2.1&Fig 2.5-Fig 2.6)
This QR code must be scanned in the APP, Quick jump thermostat pairing.
https://smartapp.tuya.com/s/p?p=N8bUqOZ8HBQjU0K0&v=1.0
ABOUT WIFI CONNECTION
Before using your Wi-Fi thermostat for the first time, you must configure the
Wi-Fi signal and settings through your smartphone or tablet ,This will allow
communication between your connected devices.
Step 1 Downlosd your APP(Fig1-1)
http://app.yimusmart.com/smartlife
Search for “Smartlife” in Apple Store or Google Play or use a browser to scan
the QR code above (Figure 1-2), and complete account r egistration and
installation according to the guidance of the APP.
Step 2. Connect the thermostat
Check the tutorial below to complete the connection and set up Method
1:Connect the mobile phone to WiFi and turn on Bluetooth. Add according to
figure (Fig 2.1-Fig2.4)
Plan A:
-
Remove the wall plate
Unscrew the wallplate from the wall and gently pull it to ensure the wires do not fall back into the hole -
Connect the mounting plate
Wire the cables through the holes in the temperature controller mounting plate. -
Connect the wires to the base
Note: Connect the R or RC wire into the RC terminal, Connect other wires to the corresponding terminals. -
DIP Switch
If you have connected both the RC-wire and the RH-wire to the wall plate, adjust the DIP on the back of the thermostat to Disconnect , otherwise switch it to Connect
09 Whether to turn on the outdoor compressor at the lowest temperature| • 0:
no 1: Yes , default 0
---|---
10 Compressor outdoor minimum outdoor temperature| • °C: 0-20,°F: 32-68
default °C: 2,°F: 32
11 Turn on the maximum temperature of the
auxiliary heat| • O:no 1:Yes , default 0
12 Auxiliary heat on outdoor maximum temperature| • °C : 0-18,°F : 32-64
default °C:18,°F: 64
13 Whether the heat pump compressor and auxiliary heat are turned on at the
same time| • O:no 1:Yes , default 1
14 Interval temperature| • °C : 1.5-5 ,°F : 3-9 default °C: 1.5 ,°F: 3
15 Cool& Heat set| • 0 to 3 , default 3
16 °F&°C display| • 0: °F 1: °C , default 1
17 Reset to facture set| • O:no 1:Yes , default 0
18 Filter replacement countdown reminder| • 0 to 180 , default 180 days
19 Enable dual energy| • 0:no 1:Yes , default 0
20 Production line test| •0 : Normal Code ,1: test Code default 0
21 Verison number| •Ul
Such as:
Schedu | Time | Heat | Cool |
---|---|---|---|
Wake | 6:00AM | 72℉(22℃) | 72℉(22℃ |
Away | 8:00AM | 72℉(22℃) | 72℉(22℃) |
Home | 17:30PM | 72℉(22℃) | 72℉(22℃) |
Sleep | 21.30PM | 72℉(22℃) | 72℉(22℃) |
Advance Options:
Press & for 3 seconds at the same time, Press to change the different items,
you can press/arrows to change settings.
01 Temperature Calibration | -9 to 9 , default -4 |
---|---|
02 Standby brightness | 3 to 99 , default 20 |
03 Min temp set | ℃:5-15 ,℉:9-27 |
default ℃:5,℉:9
04 Max temp set| ℃:15-35 ,℉:27-63
default ℃: 35,℉:63
05 1 stage compressor delay time| 1-5, default 1
06 2 stage compressor delay time| 1-5, default 1
07 Fan off delay time| 1-5, default 1
08 Cycle time for fan cycle mode| 1-11(5-55), default 2 (10)min
Attach the thermostat on base
Power on your system
Once powered up, the thermostat screen will light up and display the setup
wizard to complete configuration.
Plan B:
What is Power Module?
Power module requires your system to have the following wires:
The C-wire is used to provide power to the thermostat.
If your system does not have the “C” wire, can use the power module to power
your thermostat using the existing wires.
There are 2 sides with connections, 4 terminals is for thermostat, 5 terminals
is for the control board connections.
Operation
-
Selectiong System Mode
Press to select the mode of: Cool(Cooling only);Heat( heat only) ; Auto( Automatic control of heating and cooling based on ambient temperature); EM heat( emergency heating); Off( Off system) -
Selectiong Fan Mode
Press to select the fan mode of: On( Runs continuously); Auto ( Automatically adjust the running time of the fan according to the system);Circ( Runs at intervals to circulate indoor air) -
Selectiong Menu
Press to select the operating mode of: Permanent Hold ( Manual mode) ; Temporary Hold ( emergency heating); Using Schedule(programming mode) -
Set time
Press , the min of time will flash,touch incon / to set your time
Press , the hour of time will flash, touch the icon / set your hour
Press , the week of time will flash,
Wait for 4-5 seconds, the settings will be saved automatically. -
Child lock
Press & 3sec to set locked or unlocked -
Programa mode
Press Four times, Hour will flase, you will see the wake on the screen,means you start setting schedule for programming mode.
Press / to set time and temperture.
You can set Wake,Away,Home,Sleep 4 time period temperature.
Boiler or radiant system with air handler and conventional cooling or heat pump
| For dual heat and cooling system,if applicable For heat pump only.
---|---
Remove the jumper between Rh, Rc, or R terminals, adjust the DIP switch on the back of the thermostat to ‘Disconnect’ if you have connected both RC-wire and RH-wire to the wallplate, otherwise switch it to the ‘Connect’ side.
Install the Power Module
-
Find the HVAC terminals
Find and open the HVAC system’s cover.take a picture of the wires connected to the terminals of your old thermostat, you may need to reference this photo later.
-
Label the wires
Only label the wires from the control board to the old thermostat
-
Disconnect the wires
Disconnect wires of W/W1, Y/Y1, R to thermostat from control board. -
Connect the wiring module
Reconnect these wires to the 4-terminal side of the power module.
The wires and corresponding terminals are show below.
Heat pump (air or geothermal) with auxiliary heat
Remove the jumper between Rh, Rc, or R terminals, adjust the DIP switch on the back of the thermostat to ‘Disconnect’ if you have connected both RC-wire and RH-wire to the wallplate, otherwise switch it to the ‘Connect’ side.
Wiring diagrams
Below are the wiring diagrams for common HVAC equipment.
Conventional heating and cooling system
Remove the jumper between Rh, Rc, or R terminals, adjust the DIP switch on the back of the thermostat to ‘Disconnect’ if you have connected both RC-wire and RH-wire to the wallplate, otherwise switch it to the ‘Connect’ side
Connect the wires
5-terminal connect to HVAC control board side.
Position the wiring module
The power module should be installed between your thermostat wiring and your
control board. Install it at the right position then close the HVAC coverpanel
securely and return to your thermostat.
Add new tags
Add new tas to the follwing tags to simplify your wiring: R/RC/RH→RC;
G→C;Y/YI→S
Connect
the wires to the wallplate
First connect 3 wires as shown below
RC,C,S
DIP Switch
Adjust the DIP switch on the back of the thermostat to the Connect.
Attach the thermostat on base
Power on your system
Once powered up, the thermostat screen will light up and display the setup
wizard to complete configuration.