tempmate GM2 Real Time Temp RH Light and Location Data Logger User Manual
- May 15, 2024
- tempmate
Table of Contents
tempmate GM2 Real Time Temp RH Light and Location Data Logger
Specifications:
- Real-time monitoring of temperature & humidity, location, and track routes
- Real-time alarm notifications via SMS and email
- Data uploading capabilities
- LCD for easy monitoring
- Long battery life with charging option
- Temperature recording and alarm functions
- Device ID for easy identification
Product Usage Instructions
Start:
Long press the Start button until “REC” is displayed on the LCD interface.
The device is now ready to monitor. The current record quantity will be shown
on the LCD interface.
Setting:
Thresholds and settings can be changed via the cloud platform. You can
adjust temperature thresholds, set alarm notifications, share equipment,
configure position notifications, and set up automatic flight mode.
Transport:
Place the device inside the goods to begin transportation.
Monitoring:
Monitor temperature, humidity, location, and route through the template
cloud platform. Receive notifications via email or SMS when temperature
exceeds limits, when the device reaches a designated location, or when it
enters flight mode near an airport.
Stop:
You can stop the device in two ways: Long press the Stop button until “REC”
disappears from the LCD interface, or instruct the device to stop via the
cloud platform.
Report:
When data recording stops, the device will automatically generate a PDF
report. Connect the device to a PC via USB to access the report directly. All
transportation data is backed up on the template cloud platform and can be
viewed using the device ID.
FAQ:
-
Q: What should I do if the device doesn’t upload data to the cloud?
A: Check that the device is functioning properly and within the measurement range. -
Q: Can I dismantle the device myself?
A: Do not take apart the device by yourself to avoid damage. -
Q: How can I contact technical support?
A: For technical support, email support@tempmate.com or visit www.tempmate.com.
Appearance Instruction
Display Instruction
Instructions
To better experience the real-time monitoring (temperature & humidity, location, track routes), and real-time alarm (SMS, email) of the template wireless temperature recorder, it is recommended to register your business account on the template cloud platform’s official website (staging. template. cloud) and then add the device ID to your account before starting the device.
Start
- Long press the “Start” button till “REC” has been showing on the LCD interface, and the device is ready to monitor.
- At the same time, the record quantity also will be shown on the LCD interface.
(Using default thresholds or changing the thresholds via template cloud platform).
Setting
Thresholds can be changed via the cloud platform. On the page “Device Setting”, we can:
- Change the temperature thresholds.
- Add alarm notification personnel.
- Share equipment with someone.
- Setting position notification.
- Set up automatic flight mode.
Transport
Put the device into the goods and begin to transport.
Monitoring
Whether you set up the device or not, you also can monitor the temperature, humidity, location, and route through a template cloud platform.
- When the temperature is over the limit, the cloud platform will notify the relevant person by mail or SMS.
- Notify the presupposed person when the device reaches the designated location.
- When the device arrives near the designated airport, the device will enter the flight mode automatically
Stop
Two ways to end the journey:
- Long press the “Stop” button till “REC” disappears from the LCD interface, and the device has been stopped.
- Via the cloud platform, inform the device to stop, and the device will respond within one reporting interval in a good signal environment.
Report
- When recording data, the device will generate a PDF report automatically. Via USB cable connected to PC can access it directly.
- On the template cloud platform, the whole transportation data will be backed up and can be viewed through the device ID.
Cautions
Please read the following notes carefully before using them:
- When you find that the device doesn’t upload the data to cloud, Please confirm that the device is working properly.
- Please confirm that the device is working in the range of measurement.
- Don’t use external force to impact the device.
- Don’t take apart the device by yourself.
- Please keep the device away from fire.
- Don’t put the device into liquid.
Salute Extraordinary
Technical Support: support@tempmate.com
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Changes or
modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, under Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used by the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device and its antenna(s) must not be co-located or operated in conjunction with any other antenna or transmitter.
Radiation Exposure Statement
To maintain compliance with FCC’s RF Exposure guidelines, This equipment
should be installed and operated with a minimum distance of 20cm from your
body.