INSTALLATION & MAINTENANCE GUIDE
Important Safety Instructions: Read Before Installation
This luminaire is intended for installation in accordance with local codes and
the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance, or mounting situations.
- Make sure that the power is turned OFF before installing or servicing this luminaire.
- Warning: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from the pool, spa, or fountain.
- This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
- DO NOT INSTALL in walls where the capstones overhang the wall less than 3/4” [19mm] or under stairs where the tread overhangs the riser less than 3/4” (19mm).
- Wiring connections must be made with UL-listed wire connectors that are suitable for outdoor use.
- Position the low voltage wire and UL listed wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire, or fitting.
- The main low voltage cable is intended for shallow burial – less than 6 inches (152 mm).
Package Contents
- Luminaire
- Stainless Steel Screws
Product Dimensions
INSTALLATION & MAINTENANCE GUIDE
Optional: Install Glare Guard Before Installation
If you choose, you can attach the glare guard first before mounting the fixture. Use the screws and washers to secure the glare guard onto the fixture. Tighten with a screwdriver.
Install Luminaire in Brick or Masonry Wall
Install Mounting Plate
Determine the desired location for each luminaire before construction of the wall is started. Insert the stainless steel mounting plate (sold separately), in between the layers of hardscape material. If preferred, use an adhesive or mortar (sold separately), to secure the luminaire in place.
Install Luminaire
Route the luminaire wire through the wall to the main low voltage supply cable using standard masonry procedures. A “V” shaped notch can be cut into the hardscape material to aide in wire management.Attach the glare guard and the luminaire to the stainless steel mounting plate by using mounting screws (ships with mounting plate).
Wire Connections
Strip both leads from the luminaire pigtail. Using two UL-listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads. * We recommend ace heat shrink style connectors for hardscape connections.
Adjust Lamp Direction
Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.
Install Luminaire in Railing, Deck Over-hang or Stair
Determine the desired location for the luminaire. Place the luminaire to the
mounting surface and mark two points on the mounting surface where the holes
are on the ends of the luminaire. The marks will be used for self-tapping
screws or wall anchors.
Note: Wall anchors are required for certain installation conditions
(brick wall, concrete wall, etc.)
A wireway hole may be drilled through the decking fascia or other surface
adjacent to the mounting surface.
- Hold the luminaire in the desired mounting location. Mark the location where the wire exits the luminaire.
- Drill a hole through surface (suggested 1/4” [6.5mm] hole).
- Thread the wire through the drilled hole.
Install Luminaire
Install the luminaire and glare guard using provided self-tapping screws. If
the screws are difficult to install, mark holes and drill 1/8” pilot holes.
If wall anchors are required, drill proper holes from the marks on the
mounting surface and then insert the wall anchors. Then install the luminaire
and glare guard and secure them with the self-tapping screws.
Rubber washers are required during installation from the side.
Install the luminaire and glare guard using provided self-tapping screws. If
the screws are difficult to install, mark holes and drill 1/8” pilot holes.
If wall anchors are required, drill proper holes from the marks on the
mounting surface and then insert the wall anchors. Then install the luminaire
and glare guard and secure them with the self-tapping screws.
Rubber washers are required during installation from the side.
NOTE: DO NOT OVER TIGHTEN SCREWS.
Wire Connections
Strip both leads from the luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads. * We recommend ace heat shrink style connectors for hardscape connections.
Adjust Lamp Direction
Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.
Install Luminaire to Y Bracket
Determine Luminaire Location
Place the luminaire onto the Y bracket using the rubber washers and screws. Tighten with a screwdriver.
Install Riser
Pass the supply wire from the luminaire through the center hole on the Y bracket and the riser. Then thread the riser onto the Y bracket and hand tighten until snug.
Install Stake
Determine the desired location for mounting the stake. Hammer the stake into
the ground until flange of stake is flush to grade. To avoid damage to the
stake, place a board on top of the stake while hammering.
Note: If the ground is hard and the stake is difficult to install, make a
crosscut in the ground using a flat shovel.
Install Riser to Stake
Clear away area in the ground at were way slot on the top of the stake. Pass the fixture supply wire through the center hole of the stake and lay it into the wireway slots. Thread the riser onto the stake. Hand tighten until snug.
Wire Connections
Strip both leads from the luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads. * We recommend ace heat shrink style connectors for hardscape connections.
Adjust Lamp Direction
Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.