AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting Instruction Manual

June 6, 2024
AMP Lighting

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
logo

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig17

INSTALLATION & MAINTENANCE GUIDE

Important Safety Instructions: Read Before Installation

This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation, operation maintenance, or mounting situations.

  1. Make sure that the power is turned OFF before installing or servicing this luminaire.
  2. Warning: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from the pool, spa, or fountain.
  3. This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
  4. DO NOT INSTALL in walls where the capstones overhang the wall less than 3/4” [19mm] or under stairs where the tread overhangs the riser less than 3/4” (19mm).
  5. Wiring connections must be made with UL-listed wire connectors that are suitable for outdoor use.
  6. Position the low voltage wire and UL listed wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire, or fitting.
  7. The main low voltage cable is intended for shallow burial – less than 6 inches (152 mm).
Package Contents
  1. Luminaire
  2. Stainless Steel Screws
Product Dimensions

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig1

INSTALLATION & MAINTENANCE GUIDE

Optional: Install Glare Guard Before Installation

If you choose, you can attach the glare guard first before mounting the fixture. Use the screws and washers to secure the glare guard onto the fixture. Tighten with a screwdriver.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig2

Install Luminaire in Brick or Masonry Wall

Install Mounting Plate

Determine the desired location for each luminaire before construction of the wall is started. Insert the stainless steel mounting plate (sold separately), in between the layers of hardscape material. If preferred, use an adhesive or mortar (sold separately), to secure the luminaire in place.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig3

Install Luminaire

Route the luminaire wire through the wall to the main low voltage supply cable using standard masonry procedures. A “V” shaped notch can be cut into the hardscape material to aide in wire management.Attach the glare guard and the luminaire to the stainless steel mounting plate by using mounting screws (ships with mounting plate).AMP Lighting AHS-7005-25-B-BZ Low Voltage
Landscape Lighting fig4

 Wire Connections

Strip both leads from the luminaire pigtail. Using two UL-listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads. * We recommend ace heat shrink style connectors for hardscape connections.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig5

Adjust Lamp Direction

Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig6

Install Luminaire in Railing, Deck Over-hang or Stair

Determine the desired location for the luminaire. Place the luminaire to the mounting surface and mark two points on the mounting surface where the holes are on the ends of the luminaire. The marks will be used for self-tapping screws or wall anchors.
Note: Wall anchors are required for certain installation conditions
(brick wall, concrete wall, etc.)
A wireway hole may be drilled through the decking fascia or other surface adjacent to the mounting surface.

  1. Hold the luminaire in the desired mounting location. Mark the location where the wire exits the luminaire.
  2. Drill a hole through surface (suggested 1/4” [6.5mm] hole).
  3. Thread the wire through the drilled hole.

Install Luminaire

Install the luminaire and glare guard using provided self-tapping screws. If the screws are difficult to install, mark holes and drill 1/8” pilot holes.
If wall anchors are required, drill proper holes from the marks on the mounting surface and then insert the wall anchors. Then install the luminaire and glare guard and secure them with the self-tapping screws.
Rubber washers are required during installation from the side.
Install the luminaire and glare guard using provided self-tapping screws. If the screws are difficult to install, mark holes and drill 1/8” pilot holes.
If wall anchors are required, drill proper holes from the marks on the mounting surface and then insert the wall anchors. Then install the luminaire and glare guard and secure them with the self-tapping screws.
Rubber washers are required during installation from the side.
NOTE: DO NOT OVER TIGHTEN SCREWS.

Wire Connections

Strip both leads from the luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads. * We recommend ace heat shrink style connectors for hardscape connections.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig9

Adjust Lamp Direction

Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig10

Install Luminaire to Y Bracket

Determine Luminaire Location

Place the luminaire onto the Y bracket using the rubber washers and screws. Tighten with a screwdriver.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig11

Install Riser

Pass the supply wire from the luminaire through the center hole on the Y bracket and the riser. Then thread the riser onto the Y bracket and hand tighten until snug.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig12

Install Stake

Determine the desired location for mounting the stake. Hammer the stake into the ground until flange of stake is flush to grade. To avoid damage to the stake, place a board on top of the stake while hammering.
Note: If the ground is hard and the stake is difficult to install, make a crosscut in the ground using a flat shovel.AMP Lighting AHS-7005-25-B-BZ Low
Voltage Landscape Lighting fig13

Install Riser to Stake

Clear away area in the ground at were way slot on the top of the stake. Pass the fixture supply wire through the center hole of the stake and lay it into the wireway slots. Thread the riser onto the stake. Hand tighten until snug.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig14

Wire Connections

Strip both leads from the luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to the main supply cable leads. * We recommend ace heat shrink style connectors for hardscape connections.

AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig15

Adjust Lamp Direction

Using an Allen wrench, loosen the set screws on the ends of the lamp and then rotate the lamp to the desired direction. Always tighten the set screws after adjustments.AMP Lighting AHS-7005-25-B-BZ Low Voltage Landscape Lighting
fig16

Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AMP Lighting User Manuals

Related Manuals