tempmate M2 Multi Use USB Temperature
Introduction
The tempmate.®-M2 is designed to be mounted on a shipment or stationary and measure relevant para-meters such as temperature and optionally relative humidity. The device records data and stores it on an internal memory.
Intended Use
The tempmate.®-M2 is designed to be mounted on shipments or stationary and to record relevant parame-ters as mentioned in the data sheet. Any use or opera- tion requiring specific requirements and standards not explicitly mentioned in the data sheet must be validated and tested at the customer‘s own responsibility.
Device Description
Display
Operation and Usage
-
*STEP 1 Configuration optional**
This step is only necessary if you want to adapt the pre-installed configuration to your application. -
Download the free tempbase 2 software – https://www.tempmate.com/de/download/
-
Install the tempbase 2 software on your PC.
-
Remove the cap and connect the not started logger to your PC.
-
Open the tempbase 2 software and select the „Logger Setup“ button“ (1).
-
Make the desired settings and save them via the „Save Parameter“ button (2).
-
Remove the logger from your PC and replace the cap securely.
-
STEP 2 Start Logger
-
Press and hold the green start button for 5 seconds.
-
A successful start is indicated by the green LED on your device flashing 10 times.
-
Note : If another or no flashing signal appears, do not use the logger and contact support.
-
STEP 3 Set Mark
-
Briefly press the green start button twice in succession to set a mark.
-
A successfully set mark is indicated by the word „MARK“ and the number of marks set so far in your display.
-
Note: Up to 10 marks can be set per operation.
-
STEP 4 Stop Logger
-
Press and hold the red stop button for 5 seconds.
-
A successful stop is indicated by the red LED on your device flashing 10 times.
Alternative stop modes
Automatic Stop (default setting) -
The device will stop automatically when the maximum number of measured values in the data memory is reached and no manual stop is performed beforehand.
-
This stop mode works in addition to the manual stop. Software Stop (optional)
-
This setting can be made in the tempbase 2 software. (see STEP 1)
-
The stop is triggered automatically by connecting the logger to the PC and opening the software.
-
A manual stop is not possible in this configuration.
STEP 5 Manual Readout of Data -
Remove the cap and connect the logger to your PC.
-
A successful connection is indicated by both LEDs flashing. The abbreviations CSV and PDF appear one after the other in the display.
-
The logger automatically opens as an external drive on your PC. This process may take a few minutes depending on the amount of data.
-
Open the drive and copy the PDF and CSV report stored on it for your filing.
Note : A report is automatically generated as PDF and/or CSV when the device is stopped. The device can still be read out during a running measurement and an intermediate report can be downloaded.
Note: Already generated reports are automatically overwritten and deleted when the device is restarted.
Readout with the tempbase 2 software (optional)
- Remove the cap and connect the logger to your PC.
- Open the tempbase 2 software and select the „Export/Import“ button (3).
- Select the desired file format (PDF/XLS/IME) for export and the file location and confirm the download.
External Sensors
- Remove the cap and connect the not started logger to your PC.
- Open the tempbase 2 software and select the „Logger Setup“ button.
- In the „Sensor Type“ area, select the sensor type you want to work with.
- Confirm your configuration by clicking on „Save Parameter“ and remove the device from your PC.
- To record with an external sensor, use a screwdriver to loosen the screw on the bottom of the device and remove the standard cap.
- Replace it with the external sensor of your choice and screw it again.
Replace Battery
- Open the cover on the back of the device by turning it counterclockwise.
- Remove the old battery and dispose of it according to national regulations.
- Insert the new battery and replace the cover, closing it clockwise.
- Remove the cap and connect the logger to your PC.
- Open the tempbase 2 software to synchronize date & time again. This process is automatically trigge red when the logger is connected to PC and software.
- Caution : Back up your data and download your last report before removing the battery from the instrument.
Important Notes
- Configuration cannot be changed during recording.
- We recommend recalibration after 1 year.
- Always dispose of batteries according to your country‘s regulations.
- Do not place the device in corrosive liquids and do not expose it to direct heat.
SPECIFICATIONS
Main Technical Specifications tempmate.®-M2
Temperature Sensor| HQ Digital Temperature sensor (internal and external
optional)
Temperature Range| -30°C to +70°C (–40°C to +90°C with ext. T Sensor) (-80°C
to +200°C with ext. PT100 Sensor)
Temperature Accuracy| ±0.3°C (at –20°C to + 40°C, other 0.5°C)
Temperature Resolution| 0.1°C
Humidity Sensor| n/a
Humidity Range| n/a
Humidity Accuracy| n/a
Humidity Resolution| n/a
Data Storage| 60,000 values
Display| Big Multifunction LCD
Start Setting| Manually by pressing button, by software or timed
Recording Time| Up to 6 months
Interval| 10sec. up to 11h 59min. (default 10 min.)
Alarm Settings| Up to 6 points customizable
Alarm Type| Single alarm or cumulative
Battery| CR2450 / replaceable by customer
Dimensions| 100 x 53 x 12 mm
Weight| 54g
Protection Class| IP65
Connection Interface| USB 2.0, A-Type
Conformity| EN 12830, CE, RoHS
Software| PDF or CSV reader or tempbase 2 software / free download
Interface to PC| Integrated USB port
Reprogrammable| Yes, with internal HTML tool* or optional tempbase 2 Software
Automatic Reporting| PDF & CSV
Main Technical Specifications tempmate.®-M2
Temperature Sensor| HQ Digital Temperature sensor (internal and external
optional)
Temperature Range| -30°C to +70°C (–40°C to +90°C with ext. T Sensor) (-80°C
to +200°C with ext. PT100 Sensor)
Temperature Accuracy| ±0.3°C (at –20°C to + 40°C, other 0.5°C)
Temperature Resolution| 0.1°C
Humidity Sensor| HQ Digital Temperature/rel. Humidity sensor (internal and
external optional)
Humidity Range| 0%rH to 100%rH
Humidity Accuracy| ±3%rH (20 to 80%rH), 5% others (at 25°C)
Humidity Resolution| 0.1%rH
Data Storage| 60,000 values
Display| Big Multifunction LCD
Start Setting| Manually by pressing button, by software or timed
Recording Time| Up to 6 months
Interval| 10sec. up to 11h 59min. (default 10 min.)
Alarm Settings| up to 6 points temperature and 2 points humidity customizable
Alarm Type| Single alarm or cumulative
Battery| CR2450 / replaceable by customer
Dimensions| 100 x 53 x 12 mm
Weight| 54g
Protection Class| IP65
Connection Interface| USB 2.0, A-Type
Conformity| EN 12830, CE, RoHS
Software| PDF or CSV reader or tempbase 2 software / free download
Interface to PC| integrated USB port
Reprogrammable| Yes, with internal HTML tool* or optional tempbase 2 Software
Automatic Reporting| PDF & CSV
Main Technical Specifications tempmate.®-M2 Accessory
tempmate.®-M2 External T-Sensor
Sensor| HQ Digital Temperature Sensor
Temperature Range| –40°C to +90°C
Temperature Accuracy| 0.3°C (at –20 ° C to + 40 ° C, other 0.5°C)
Temperature Resolution| 0.1°C
Sensor Tip| Stainless Steel (30 x 5 mm)
Sensor Connetion| M2-USB Connection
Cable length| 1.2 m
Cable Diameter| 3 mm
Cable Material| PVC
tempmate.®-M2 External High/Low T-Sensor
Temperature Sensor| PT100 Sensor
Temperature Range| -80°C to +200°C
Temperature Accuracy| ±1°C
Temperature Resolution| 0,1°C
Sensor Tip| Stainless Steel (30 x 5 mm)
Sensor Connetion| M2-USB Connection
Cable Diameter| 3 mm
Cable length| 1.2 m
Cable Material| PTFE
tempmate.®-M2 External T/rH-Sensor
Sensor| HQ Digital Temperature/rel. Humidity Sensor
Temperature Range| –40°C to +90°C
Temperature Accuracy| 0.3°C (at –20 ° C to + 40 ° C, other 0.5°C)
Temperature Resolution| 0,1°C
Humidity Range| 0 – 100 %rH
Humidity Accuracy| ±3%rH (10% to 70%), 5% others (at +25°C)
Humidity Resolution| 0.1 %rH
Sensor Tip| Stainless Steel (30 x 5 mm)
Sensor Connetion| M2-USB Connection
Cable length| 1.2 m
Cable Diameter| 3 mm
Cable Material| PVC