ONETOUCH 6300 Verio Reflect Blood Glucose Monitoring System Owner’s Manual

March 7, 2024
ONETOUCH

6300 Verio Reflect Blood Glucose Monitoring System

“`html

Specifications:

  • Product Name: Blood Glucose Monitoring System

  • Intended Use: Monitoring blood glucose levels

  • Usage: For single patient use only

  • Test Principle: Glucose in the blood sample mixes with enzyme
    FAD-GDH to produce a small electric current for calculating blood
    glucose levels

  • Data Storage: Stores blood glucose results in meter memory

  • Unit of Measure: mmol/L

Product Usage Instructions:

Getting Started:

  1. Ensure all components are included in the kit.

  2. Keep the meter and testing supplies away from children.

  3. Insert test strip into the test strip port to turn on the
    meter.

  4. Check battery icon for low battery indication.

Testing Blood Glucose Levels:

  1. Apply blood sample to the channel on the test strip.
  2. Ensure the unit of measure displayed is mmol/L.
  3. Wait for the result to be displayed on the meter.
  4. Record the blood glucose result if needed.

Meter Maintenance:

  1. Do not leave the meter unattended in public places.
  2. Avoid ingesting any components of the meter.
  3. Keep the meter clean and dry.
  4. Contact Customer Care for any missing or defective items in the
    kit.

Data Management:

  1. Connect the meter to a computer via the micro USB data port for
    data download.

  2. Review summary results, logs, and trends on the meter.

  3. Set daily testing goals using the Test Tracker icons.

FAQ:

Q: Can the blood glucose monitoring system be shared between

patients?

A: No, the system is intended for single patient use only to
ensure accurate results and data management.

Q: What should I do if my display shows mg/dL instead of

mmol/L?

A: Stop using the meter immediately and contact Customer Care
for assistance in correcting the unit of measure display.

“`

Blood Glucose Monitoring System
Owner’s Booklet
Instructions for Use

Blood Glucose Monitoring System
Owner’s Booklet
1

Thanks for choosing the OneTouch Verio Reflect® System! The OneTouch Verio Reflect® Blood Glucose Monitoring System is one of the latest product innovations from OneTouch®.
Your OneTouch Verio Reflect® Meter is designed to connect (sync) with a variety of compatible wireless devices running software applications. By connecting your meter with the OneTouch Reveal® App you can review and graph your results, set Daily Test Goals, see Blood Sugar MentorTM Messages and help identify patterns. Meter results and other tracked data are sent to the compatible devices either through BLUETOOTH® (wireless) or USB cable connection. Visit www.OneTouch.ca for more information about the OneTouch Reveal® App. Every OneTouch® Meter is designed to help you test your blood glucose and manage your diabetes. This Owner’s Booklet offers a complete explanation of how to use your new meter and testing supplies. It reviews the do’s and don’ts of testing your blood glucose level. Please keep your Owner’s Booklet in a safe place; you may want to refer to it in the future. We hope OneTouch® products and services will continue to be a part of your life.
2

Meter symbols and icons

Range Indicator icons and Colour Bar

Low

Result below target range

Result at low end of target range

Result near middle of target range

Result in middle of target range

Result near middle of target range

Result at high end of target range High Result above target range

In Range

Result in range (text)

3

Meal and Event tags
Before Meal tag After Meal tag Event tag Carbs Event tag Stress Event tag Illness Event tag Medication Event tag Exercise Event tag
Patterns, Test Tracker, and Awards Low Pattern Message (blue icon) High Pattern Message (red icon) Daily Test Goal met Daily Test Goal not met Gold award Silver award Bronze award
4

Main Menu and Settings Menu icons Summary Results Log Trend 90 Settings Menu Range Indicator icons as emoji Range Indicator icons as text
Other meter icons BLUETOOTH® feature on Syncing Control solution result Low battery Screen navigation progress dots
5

Other symbols and icons
Cautions and Warnings: Refer to the Owner’s Booklet and inserts that came with your system for safety-related information. Direct current
6

Before you begin Before using this product to test your blood glucose, carefully read this Owner’s Booklet, and the inserts that come with the OneTouch Verio® Test Strips, OneTouch Verio® Control Solution and the OneTouch® Delica® Plus Lancing Device.
IMPORTANT SAFETY INSTRUCTIONS: · This meter and lancing device are for single patient use
only. Do Not share them with anyone else, including family members! Do Not use on multiple patients! · After use and exposure to blood, all parts of this kit are considered biohazardous. A used kit may potentially transmit infectious diseases even after you have performed cleaning and disinfection.
Intended use The OneTouch Verio Reflect® Blood Glucose Monitoring System is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes mellitus for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips as an aid in the management of diabetes.
7

The OneTouch Verio Reflect® Meter analyzes patterns, tracks trends and provides guidance (educational, behavioral and motivational messages) to help aid in the understanding and management of glucose levels and the detection of excursions above or below a desired range. The meter is also designed to wirelessly communicate with compatible diabetes applications for the capture, transfer and analysis of blood glucose data and information, to help support diabetes self-management.
The OneTouch Verio Reflect® Blood Glucose Monitoring System should not be used as a substitute for healthcare professional advice. It also should not be used for the diagnosis or screening of diabetes or for neonatal use.
The system is intended to be used by a single patient and should not be shared.
Test principle
Glucose in the blood sample mixes with the enzyme FAD-GDH (see page 114) in the test strip and a small electric current is produced. The strength of this current calculates your blood glucose level. It then displays the blood glucose result and stores it in the meter memory.
Use only OneTouch Verio® Control Solution and Test Strips with the OneTouch Verio Reflect® Meter. Use of OneTouch Verio® Test Strips with meters for which they are not intended may yield inaccurate results.
8

BLUETOOTH® wireless technology BLUETOOTH® wireless technology is used by some smartphones and many other devices. Your OneTouch Verio Reflect® Meter uses BLUETOOTH® wireless technology to pair and to send your glucose results to compatible wireless devices. The OneTouch Verio Reflect® Meter is designed to work with the OneTouch Reveal® Mobile App and other diabetes applications. Visit www.OneTouch.ca for information on which wireless devices are compatible with your OneTouch Verio Reflect® Meter, and where/how to download the software application.
9

When using the OneTouch Verio Reflect® System, we suggest you pair your OneTouch Verio Reflect® Meter with a compatible wireless device and track your results. See page 83 for pairing instructions. This Class B digital apparatus complies with Canadian ICES-003. This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference (2) This device must accept any interference, including interference that may cause undesired operation of the device. These guidelines help ensure that your meter will not affect the operation of other nearby electronic devices. Additionally, other electronic devices should not affect the use of your meter. If you experience meter interference problems, try moving your meter away from the source of the interference. You can also move the electronic device or its antenna to another location to solve the problem.
10

WARNING: The BLUETOOTH® feature on your meter sends test results to your compatible wireless device. To prevent other people’s results from being sent to your compatible wireless device, Do Not let anyone else use your meter to test their blood glucose. This meter is for single patient use only.
WARNING: In locations where cell phone use is not permitted, such as hospitals, some healthcare professional offices and airplanes, you should turn the BLUETOOTH® feature off. See page 80 for more information.
Do Not leave your meter unattended or in a public place so that others may change your personal parameters or make physical connections to it. The meter has been designed defensively to ward off malicious intent and has been tested accordingly.
BLUETOOTH® trademark The BLUETOOTH® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by LifeScan Scotland Ltd. is under license. Other trademarks and trade names are those of their respective owners.
11

Table of Contents
1 Getting to know your system…………………………….. 13 2 Setting up your system……………………………………… 21 3 Taking a test……………………………………………………… 31 Testing your blood glucose……………………………………………..31 Testing with control solution…………………………………………. 52 4 Tagging results………………………………………………….60 5 Understanding Messages ………………………………….. 63 6 Summary, Results Log and Trend 90 ………………….. 71 7 Syncing your meter……………………………………………80 8 Adjusting meter settings……………………………………88 9 Caring for your system ………………………………………98 10 Batteries………………………………………………………….102 11 Troubleshooting……………………………………………… 105 12 System information…………………………………………. 112 13 Index………………………………………………………………. 122
12

1 Getting to know your system 1
Your OneTouch Verio Reflect® Blood Glucose Monitoring System Included with your kit:

Lancing device

OneTouch Verio Reflect® Meter (2 CR2032 lithium coin cell batteries included)

Lancets

13

1 Getting to know your system
NOTE: If any item is missing or defective in your kit, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet. NOTE: If another type of lancing device was included, see the separate instructions for that lancing device.
Available separately: Items pictured below are required, but may not be included in your kit: They are sold separately. Refer to your meter carton for a list of included items.

OneTouch Verio® Mid Control Solution*

OneTouch Verio® Test Strips*

*OneTouch Verio® Control Solution and Test Strips are available separately. For availability of test strips and control solution, contact Customer Care or ask your pharmacist or healthcare professional.

14

Getting to know your system 1 WARNING: Keep the meter and testing supplies away from young children. Small items such as the battery door, batteries, test strips, lancets, protective covers on the lancets, and control solution vial cap are choking hazards. Do Not ingest or swallow any items.
15

1 Getting to know your system Getting to know your OneTouch Verio Reflect® Blood Glucose Monitoring System
Meter
16

Getting to know your system 1
1 Test strip port Insert test strip here to turn meter on
2 Battery icon Appears only when batteries are low
3 mmol/L is the pre-set unit of measure and cannot be changed
4 Micro USB data port Connect to download to a computer
5 OK button · Turns meter on/off (press and hold) · Confirms menu selections (press and release)
6 Back button · Go back to the previous screen (press and release) · May be used to change a Meal tag or add an Event tag
7 Up and down buttons · Highlight selection (press and release) · Increase scrolling speed (press and hold)
8 Colour Bar 9 Range Indicator icon 10 Test Tracker icons
WARNING:
Confirm that the unit of measure mmol/L is displayed. If your display shows mg/dL rather than mmol/L, stop using the meter and contact Customer Care.
17

1 Getting to know your system Getting to know your OneTouch Verio® Test Strip
Test strip
11 Channel to apply sample 12 Silver prongs
Insert into test strip port (1)
Features overview The OneTouch Verio Reflect® Meter is equipped with features designed to help you manage your blood glucose in a variety of ways. We hope you will take advantage of these features and make them part of your diabetes management routine.
18

Getting to know your system 1

Blood Sugar MentorTM Messages
The Blood Sugar MentorTM provides insight on how you’re doing and diabetes management guidance, including educational and motivational messages based on your current and previous glucose results and other tracked data. When you receive your blood glucose result, the meter may display Mentor Tips (guidance), Pattern Messages (insight) or Awards (encouragement).

Examples of Blood Sugar MentorTM Messages

11.1
mmol/L
Pattern found High in the last 5 days at this time. Has anything changed?
OK
Insight

3.1
mmol/L
Treat Low Low result, juice may help. Retest in 15 minutes.
OK
Guidance

5.8
mmol/L Well done Back in range after 2 Low results in a row.
OK
Encouragement

19

1 Getting to know your system
ColourSure® Dynamic Range Indicator The ColourSure® Dynamic Range Indicator instantly lets you know if your current result is below (blue), within (green) or above (red) your range limits. It also shows when your result is near the low or high end of your target range. Test Tracker The Test Tracker lets you set the number of glucose tests you plan to take each day and automatically tracks progress towards achieving that goal. Trend 90 Trend 90 lets you set your blood glucose 90 Day Average Target and tracks progress towards that goal. The graph of averages is automatically updated every two weeks and provides a view of how your overall glucose control is trending over time.
20

2 Setting up your system 2

Setting up your meter

Turn your meter on To turn your meter on, press and hold until the Welcome screen appears. Once the Welcome screen is displayed, release . You can also turn the meter on by inserting a test strip.

Every time you turn your meter on, a Welcome screen will appear for a few seconds. If the meter does not power on, check the batteries. See page 102.
CAUTION:
If you see any missing pixels within the Welcome screen, there may be a problem with the meter. Contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

Welcome. Let’s get started.
Example

NOTE: Whether you turn the meter on for the first time using or a test strip, you will need to perform first time setup.

21

2 Setting up your system
Use the display backlight for better visibility The backlight comes on automatically whenever the meter is turned on. After a few seconds of no activity, the backlight will dim. Pressing any button or inserting a test strip will turn the backlight back on.
First time setup Before using your meter for the first time, you will be prompted to set the language, time, date, range limits, Daily Test Goal, and 90 Day Average Target.
NOTE: · You will not be able to perform a blood glucose test until
you complete first time setup. · Be sure to talk to your healthcare professional about
setting the right range limits, Daily Test Goal, and 90 Day Average Target for you. When selecting or changing these settings, you should consider factors such as your lifestyle and diabetes therapy. Never make significant changes to your diabetes care plan without consulting your healthcare professional. · It is important to select the settings with care to ensure the correct information is stored with your test results.
22

Setting up your system 2

The meter comes pre-set to help you with first time setup. But if you need to edit a setting, press or to highlight Edit and press . You can then press or to change values. After making your selection, highlight Save and press to confirm your selection and proceed to the next screen.
Pressing returns you to the previous screen.

1. Press or to highlight the language you want, then press to select
The meter will display a prompt giving the option to complete first time setup using the OneTouch Reveal® App. Visit www.OneTouch.ca for more information about the OneTouch Reveal® App. If you do not want this option, highlight No and press to continue first time setup using only the meter.

Language
English Français

23

2 Setting up your system

Selecting Yes will prompt you to pair the meter with your compatible wireless device. See page 81. After pairing, the OneTouch Reveal® App will guide you through the process of first time setup. The remaining steps below will not be needed.
NOTE: The green progress dot will move from left to right as you navigate through the first time setup screens.
2. Confirm the time, then press to save Selecting Edit will allow you to change the pre-set time.
3. Confirm the date, then press to save Selecting Edit will allow you to change the pre-set date.

Setup
Do you want to continue setup using the OneTouch Reveal
mobile app?
Yes No
Progress dot
Set Time
1:00 pm Save Edit
Set Date
Jul 4 2018 Save Edit

24

Setting up your system 2

NOTE:
· The time and date format cannot be changed.
· Once every 6 months, and every time you change the batteries, a screen will prompt you to confirm the time and date set in the meter.

Please Verify
Jul 4 2018 1:00 pm
Is this time/date correct?
Yes Edit

Example

Selecting Edit will allow you to change the time and date. Once correct, select Done.

4. Confirm the Before Meal range limits, then press to save

Before Meal
Set Low/High Limits for your range
3.9 ­ 7.2
mmol/L
Save Edit

Example
Selecting Edit will allow you to change the pre-set Before Meal range limits.

25

2 Setting up your system

Your meter uses the Before Meal and After Meal range limits set in your meter to tell you when a test result is within, below or above your mealtime range limits. The mealtime range limits you set during first time setup will apply to all glucose results. They are used in the ColourSure® Dynamic Range Indicator feature, to detect Patterns and in the Summary. See page 44, page 64 and page 71 for more information.

Before Meal range limits
pre-set low limit pre-set high limit low limit must be set within high limit must be set within

4.0 mmol/L 7.0 mmol/L 3.3 mmol/L and 6.1 mmol/L 5.0 mmol/L and 16.7 mmol/L

5. Confirm the After Meal range limits, then press to save

After Meal
Set Low/High Limits for your range
3.9 ­ 10.0
mmol/L
Save Edit

Example
Selecting Edit will allow you to change the pre-set After Meal range limits.

26

Setting up your system 2

After Meal range limits
pre-set low limit pre-set high limit low limit must be within high limit must be within

5.0 mmol/L 10.0 mmol/L 3.3 mmol/L and 6.1 mmol/L 5.0 mmol/L and 16.7 mmol/L

6. Confirm the Test Tracker setting, then press to save
Selecting Edit will allow you to change the pre-set Daily Test Goal for the Test Tracker.
The Test Tracker lets you set the number of glucose tests you plan to take each day and automatically tracks progress towards achieving that goal.
The meter is pre-set with a Daily Test Goal of four tests per day. The maximum Daily Test Goal is eight. See page 94 for more information.

Test Tracker
Set a Daily Test Goal?
Test Goal: 4 Save Edit

27

2 Setting up your system

7. Confirm the 90 Day Average Target, then press to save

Trend 90

Set your 90 Day

Selecting Edit will allow you to change Average Target

the pre-set 90 Day Average Target.

8.6 mmol/L

Trend 90 lets you set your blood glucose 90 Day Average Target and tracks progress towards that goal.

Save Edit

The graph of averages is automatically

updated every two weeks and provides a view of how your

overall glucose control is trending over time.

The meter is pre-set with a 90 Day Average Target of 8.6 mmol/L. The minimum 90 Day Average Target is 5.5 mmol/L and the maximum is 14.7 mmol/L. See page 78 for more information.

Setup complete appears on the screen. Your meter is ready for use.

Setup complete

28

Setting up your system 2
If the meter was turned on by inserting a test strip, the Apply Blood screen will appear. To perform a blood glucose test, see page 31. NOTE: After first time setup, you can adjust your settings at any time. See page 88 for more information.
Understanding Basic Mode The meter comes with many features to help track diabetes management progress. Basic Mode will turn off these features if you prefer not to use the meter in this way. When Basic Mode is selected, the Test Tracker, Meal and Event tagging, Before and After Meal averages, Trend 90, Pattern Messages, Mentor Tips and Awards will be turned off. In Basic Mode, range limits are general and are not defined by mealtime. Range Indicator icons appear as text (for example, In Range ) rather than as emoji (for example, ). For more information about turning Basic Mode on or off see page 93.
29

2 Setting up your system Turning the meter off There are three ways to turn your meter off: · Press and hold for several seconds until the meter
turns off. · Remove the test strip. · Your meter will turn off by itself if left alone for
two minutes.
30

3 Taking a test 3
Testing your blood glucose Preparing for a blood glucose test NOTE: Many people find it helpful to practice testing with control solution before testing with blood for the first time. See page 53. Have these things ready when you test:
OneTouch Verio Reflect® Meter OneTouch Verio® Test Strips Lancing device Sterile lancets
NOTE: · Use only OneTouch Verio® Test Strips. · Unlike some blood glucose meters, no separate step to
code your OneTouch Verio Reflect® System is required. · Testing must be done within operating temperature
range (6-44°C). · Make sure your meter and test strips are about the same
temperature before you test. · Keep test strips in a cool, dry place between 5°C
and 30°C.
31

3 Taking a test
· Do Not test if there is condensation (water build-up) on your meter. Move your meter and test strips to a cool, dry spot and wait for the meter surface to dry before testing.
· Do Not open the test strip vial until you are ready to remove a test strip and perform a test. Use the test strip immediately after removing it from the vial.
· Tightly close the cap on the vial immediately after use to avoid contamination and damage.
· Store unused test strips only in their original vial. · Do Not return the used test strip to the vial after
performing a test. · Do Not re-use a test strip that had blood, control
solution, or any contaminants applied to it. Test strips are for single use only. · With clean, dry hands, you may touch the test strip anywhere on its surface. Do Not bend, cut or modify the test strip in any way. · When you first open a vial of test strips, record the discard date on the label. Refer to the test strip insert or vial label for instructions on determining the discard date.
32

Taking a test 3
· Comparing your blood glucose test results taken with this meter to your results taken from a different meter is not recommended. Results may differ between meters and are not a useful measure of whether your meter is working properly. To check your meter accuracy, you should periodically compare your meter results to those obtained from a lab. See page 112 for more information.
IMPORTANT: If another person assists you with testing, the meter should always be cleaned prior to use by that person. See page 98.
CAUTION: · The OneTouch Verio Reflect® Blood Glucose Monitoring
System should not be used for patients within 24 hours of receiving a D-xylose absorption test as it may cause inaccurately high results. · Do Not use the OneTouch Verio® Family of Meters when PAM (Pralidoxime) is known or suspected to be in the patient’s whole blood sample.
33

3 Taking a test
· Do Not use your test strips if your vial is damaged or left open. This could lead to error messages or inaccurate results. Contact Customer Care immediately if the test strip vial is damaged. Contact information for Customer Care is listed at the end of this Owner’s Booklet.
· If you cannot test due to a problem with your testing supplies, contact your healthcare professional. Failure to test could delay treatment decisions and lead to a serious medical condition.
· The test strip vial contains drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation.
· Do Not use test strips after the expiration date (printed on the vial) or the discard date, whichever comes first, or your results may be inaccurate.
34

Taking a test 3
Getting to know your OneTouch® Delica® Plus Lancing Device
1 Release button 2 Slider control 3 Depth indicator 4 Depth wheel 5 Lancing device cap 6 Protective cover
NOTE: · The OneTouch® Delica® Plus Lancing Device uses
OneTouch® Delica® or OneTouch® Delica® Plus Lancets. · If another type of lancing device was included, see the
separate instructions for that lancing device. · The OneTouch Verio Reflect® Blood Glucose Monitoring
System has not been evaluated for Alternate Site Testing (AST). Use only fingertips when testing with the system.
35

3 Taking a test
Lancing precautions CAUTION:
To reduce the chance of infection and disease spread by blood: · Make sure to wash the sample site with soap and warm
water, rinse and dry before sampling. · The lancing device is intended for a single user. Never
share a lancet or lancing device with anyone. · Always use a new, sterile lancet each time you test. · Always keep your meter and lancing device clean.
(See page 98.) · The meter and lancing device are for single patient use
only. Do Not share them with anyone, including family members! Do Not use on multiple patients! · After use and exposure to blood, all parts of this kit are considered biohazardous. A used kit may transmit infectious diseases even after you have performed cleaning and disinfection. · Do Not use lancets after the expiration date printed on the lancet packaging.
36

Taking a test 3
Preparing your lancing device 1. Remove the lancing device cap Remove the cap by rotating it and then pulling it straight off the device.
2. Insert a sterile lancet into the lancing device Align the lancet as shown here, so that the lancet fits into the lancet holder. Push the lancet into the device until it snaps into place and is fully seated in the holder. Twist the protective cover one full turn until it separates from the lancet. Save the protective cover for lancet removal and disposal. See page 49.
37

3 Taking a test
3. Replace the lancing device cap Place the cap back onto the device; turn the cap or push the cap straight on to secure it. Ensure the cap is aligned as shown in the image.
4. Adjust the depth setting The device has 13 puncture depth settings (each dot shown between numbers 1 to 7 on the Depth Wheel indicates an additional available depth setting). Adjust the depth by turning the depth wheel. Smaller numbers are for a shallower puncture and larger numbers for a deeper puncture. NOTE: Try a shallower setting first and increase the depth until you find the one deep enough to get a blood sample of the proper size.
38

Taking a test 3 5. Cock the lancing device Pull the slider back until it clicks. If it does not click, it may already have been cocked when you inserted the lancet. Preparing the meter 1. Insert a test strip to turn the meter on Insert a test strip into the test strip port with the gold side of the test strip and the two silver prongs facing you.
Silver prongs
Test strip port NOTE: No separate step to code the meter is required.
39

3 Taking a test
The Apply Blood screen appears on the display. You can now apply your blood sample to the test strip.
Apply Blood
Sampling blood from the fingertip Choose a different puncture site each time you test. Repeated punctures in the same spot may cause soreness and calluses. Before testing, wash your hands and the sample site with warm, soapy water. Rinse and dry completely. Contaminants on the skin may affect results. 1. Puncture your finger Hold the lancing device firmly against the side of your finger. Press the release button. Remove the lancing device from your finger.
40

Taking a test 3 2. Get a round drop of blood Gently squeeze and/or massage your fingertip until a round drop of blood forms.
NOTE: If the blood smears or runs, Do Not use that sample. Dry the area and gently squeeze another drop of blood or puncture a new site.
Applying blood and reading results Applying the sample 1. Apply the sample to the test strip You can apply blood to either side of the test strip.
41

3 Taking a test
Apply your sample to the opening of the channel. Be sure to apply your sample immediately after you get a drop of blood.

Holding the meter at a slight angle, guide the channel to the blood drop.

Channel

When it touches your sample, the test strip wicks blood into the channel.

42

Taking a test 3
2. Wait for the channel to fill completely The blood drop will be drawn into the narrow channel. The channel should fill completely. The channel turns red and a result will be displayed after approximately 5 seconds. Blood should not be applied on the top of the test strip or to the top edge of the test strip.
NOTE: · Do Not smear or scrape the sample with the test strip. · Do Not press the test strip too firmly against the puncture
site or the channel may be blocked from filling properly. · Do Not apply more blood to the test strip after you have
moved the drop of blood away. · Do Not move the test strip in the meter during a test or
you may get an error message or the meter may turn off. · Do Not remove the test strip until the result is displayed
or the meter will turn off.
43

3 Taking a test
Viewing your result ColourSure® Dynamic Range Indicator The OneTouch Verio Reflect® Meter comes with a ColourSure® Dynamic Range Indicator feature that instantly lets you know if your current result is below (blue), within (green) or above (red) your range limits. It also shows when your result is near the low or high end of your target range. It does this by displaying your result with a Range Indicator icon pointing to a segment on the Colour Bar based on the ranges you have set in the meter. The Range Indicator icon may be either an emoji (for example, ) or text (for example In Range ). Use the Range Indicator icon and the segmented Colour Bar together to see where your result falls within your range limits.
44

Taking a test 3

3.1
mmol/L Before Meal
Low

4.2
mmol/L
Before Meal

10.3
mmol/L
Before Meal
High

Low (Blue)
Example – below range result

In Range (Green)
Example – low end of range result

High (Red)
Example – above range result

If the Test Tracker is turned on, progress toward the Daily Test Goal will be indicated above the result. If the Test Tracker is turned off, the date and time will be shown above the result. The date and time are always recorded with each result and can be viewed in the Results Log. See page 75.

WARNING: Confirm that the unit of measure mmol/L is displayed. If your display shows mg/dL rather than mmol/L, stop using the meter and contact Customer Care.

45

3 Taking a test

CAUTION:

Do Not make immediate treatment decisions based on the ColourSure® Dynamic Range Indicator feature. Treatment decisions should be based on the numerical result and healthcare professional’s recommendation and not solely on where your result falls within your range limits.

After the result screen appears, a Pattern Message, Mentor Tip or Award may be displayed. The Message can be dismissed by pressing . If you would like to bring the Message back, press again. See page 63 for more information about Messages.

5.8
mmol/L
Well done Back in range after 3 High results in a row.
OK

Example

A Before Meal tag will automatically be applied to your result. When you change a Before Meal tag to an After Meal tag, the Range Indicator icon may point to a different segment on the Colour Bar. A new Message may appear. See page 60 for information on tagging results.

46

Taking a test 3

Interpreting unexpected results
Refer to the following cautions when your results are higher or lower than what you expect.

CAUTION:

Warning

Low blood glucose results

EXTREME LOW

If your blood glucose result is below 4.0 mmol/L or is shown as EXTREME

GLUCOSE
Below 1.1 mmol/L

LOW GLUCOSE, (meaning the result

Treat Low

is less than 1.1 mmol/L), it may

mean hypoglycemia (low blood

glucose). This may require immediate

treatment according to your healthcare professional’s

recommendations. Although this result could be due to a

test error, it is safer to treat first, then do another test.

CAUTION:
Dehydration and low blood glucose results
You may get false low blood glucose results if you are severely dehydrated. If you think you are severely dehydrated, contact your healthcare professional immediately.

47

3 Taking a test

CAUTION:
High blood glucose results
If your blood glucose result is above 10.0 mmol/L, it may mean hyperglycemia (high blood glucose) and you should consider re-testing. Talk to your healthcare professional if you are concerned about hyperglycemia.

Warning
EXTREME HIGH GLUCOSE
Above 33.3 mmol/L

EXTREME HIGH GLUCOSE is displayed when your blood glucose result is over 33.3 mmol/L. You may have severe hyperglycemia (very high blood glucose). Re-test your blood glucose level. If the result is EXTREME HIGH GLUCOSE again, this indicates a severe problem with your blood glucose control. Obtain and follow instructions from your healthcare professional immediately.

48

Taking a test 3
CAUTION: Repeated unexpected blood glucose results · If you continue to get unexpected results, check your
system with control solution. See page 53. · If you are experiencing symptoms that are not consistent
with your blood glucose results and you have followed all instructions in this Owner’s Booklet, call your healthcare professional. Never ignore symptoms or make significant changes to your diabetes management program without speaking to your healthcare professional. Unusual red blood cell count A hematocrit (percentage of your blood that is red blood cells) that is either very high (above 60%) or very low (below 20%) can cause false results.
Removing the used lancet NOTE: This lancing device has an ejection feature, so you do not have to pull out the used lancet.
49

3 Taking a test
1. Remove the lancing device cap Remove the cap by rotating it and then pulling it straight off the device.
2. Cover the exposed lancet tip Before removing the lancet, place the lancet protective cover on a hard surface then push the lancet tip into the flat side of the disk.
3. Eject the lancet Holding the lancing device directed downwards, push the slider forward until the lancet comes out of the lancing device. If the lancet fails to eject properly, cock the device then push the slider control forward until the lancet comes out.
50

Taking a test 3
4. Replace the lancing device cap Place the cap back onto the device; turn the cap or push the cap straight in to secure it. Ensure the cap is aligned as shown in the image.
It is important to use a new lancet each time you obtain a blood sample. Do Not leave a lancet in the lancing device. This will help prevent infection and sore fingertips. Disposing of the used lancet and test strip Discard the used lancet carefully after each use to avoid unintended lancet stick injuries. Used lancets and test strips may be considered biohazardous waste in your area. Be sure to follow your healthcare professional’s recommendations or local regulations for proper disposal. Wash hands thoroughly with soap and water after handling the meter, test strips, lancing device and cap.
51

3 Taking a test
Testing with control solution Control solution testing precautions OneTouch Verio® Control Solution is used to check that the meter and test strips are working together properly and that the test is performing correctly. (Control solution is available separately.)
NOTE: · Use only OneTouch Verio® Control Solution with your
OneTouch Verio Reflect® Meter. · When you first open a new vial of control solution,
record the discard date on the vial label. Refer to the control solution insert or vial label for instructions on determining the discard date. · Tightly close the cap on the control solution vial immediately after use to avoid contamination or damage.
CAUTION: · Do Not swallow or ingest control solution. · Do Not apply control solution to the skin, eyes, ears or
nose as it may cause irritation. · Do Not use control solution after the expiration date
(printed on the vial label) or the discard date, whichever comes first, or your results may be inaccurate.
52

Taking a test 3

When to do a control solution test
· When you open a new vial of test strips. · If you suspect that the meter or test strips are not working
properly. · If you have had repeated unexpected blood glucose
readings. · If you drop or damage the meter.

Preparing your meter for a control solution test
1. Press and hold to turn the meter on
Wait for the Main Menu to appear.

2. Press or to highlight Settings, then press

May 2

9:31 am

Summary

Results Log

Trend 90

Settings

53

3 Taking a test 3. Highlight Control Test, then press Wait for the Insert Strip screen to appear on the display.
4. Insert a test strip into the test strip port

Settings Language Range/90d Features Messages Bluetooth Control Test

5. Wait for the Apply Control Solution screen to appear on the display

Insert Strip
Apply Control Solution

54

Taking a test 3 Preparing the control solution 1. Before removing the cap, shake the vial gently 2. Remove the vial cap and place it on a flat surface with the top of the cap pointing up 3. Squeeze the vial to discard the first drop
4. Wipe both the tip of the control solution vial and the top of the cap with a clean, damp tissue or cloth
55

3 Taking a test 5. Squeeze a drop into the small well on the top of the cap or onto another clean, non-absorbent surface Applying the control solution 1. Hold the meter so that the side edge of the test strip is at a slight angle to the drop of control solution 2. Touch the channel on the side of the test strip to the control solution 3. Wait for the channel to fill completely
56

Taking a test 3

Viewing your control solution result

After the control solution is applied, your meter will display a progress screen for approximately 5 seconds. Your result is displayed along with the date, time, unit of measure, and
(for control solution).

Jul 4

6:30 am

6.7

mmol/L

Control Solution

Example

Control solution results are stored in the meter and can be seen when reviewing past results on the meter.
CAUTION:
Make sure you select Control Test from the Settings Menu before you begin a control solution test. Follow the steps beginning on page page 53. If does not appear on the screen, this result will be included in your averages and your averages will change too. Repeat the test with a new test strip. If the problem persists, Contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

57

3 Taking a test

Checking if the result is in range

Compare the result displayed on the meter to the range printed on your OneTouch Verio® Control Solution vial. If your control solution result falls outside the expected range, repeat the test with a new test strip.

Example range OneTouch Verio® Mid Control Solution Control Range 5.7-7.7 mmol/L

CAUTION: The range printed on the control solution vial is for control solution tests only and is not a recommended range for your blood glucose level.

58

Taking a test 3
Causes of out-of-range results Out-of-range results may be due to: · Not following the instructions for performing a control
solution test. · Control solution is contaminated, expired, or past its
discard date. · Test strip or test strip vial is damaged, expired, or past its
discard date. · Meter, test strips and/or control solution were not all at
the same temperature when the control solution test was performed. · A problem with the meter. · Dirt or contamination in the small well on the top of the control solution cap.
CAUTION: If you continue to get control solution results that fall outside the range printed on the control solution vial, Do Not use the meter, test strips, or control solution. Contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.
Cleaning the control solution cap Clean the top of the control solution cap with a clean, damp tissue or cloth.
59

4 Tagging results
Adding Meal and Event tags Your OneTouch Verio Reflect® Meter allows you to attach a Before Meal ( ) or After Meal ( ) tag to your current blood glucose result. It is important to understand the link between blood glucose levels and food. When you tag your test results with Meal tags, you add information about food to your results. Your meter uses this information in a variety of ways and displays Pattern Messages, Mentor Tips and Awards. Talk to your healthcare professional to see how Meal tags may help you manage your diabetes. Consider the following guidelines when Meal tagging.
· A Before Meal blood glucose test is taken just before the start of your meal.
· An After Meal blood glucose test is typically taken one to two hours after the start of your meal.
· A blood glucose test taken while fasting should be tagged as Before Meal.
In addition to Meal tagging, your OneTouch Verio Reflect® Meter includes an Event tagging feature. Event tagging adds information about your health and lifestyle events to your blood glucose results. Your meter will review your past results and display Messages associated with tagged results when certain conditions are met. See page 3 for Event tag icons and their meanings.
60

Tagging results 4

1. View the current blood glucose result on the display

The result will automatically receive a Before Meal tag and no Event tag.
2. If a Message appears, press to clear the Message

3. To change to an After Meal tag, press then highlight After Meal and press
NOTE: The Range Indicator icon displayed with the result uses Before and After Meal ranges. When you change a Before Meal tag to an After Meal tag, the Range Indicator icon may point to a different segment on the Colour Bar. A new Message may appear.

6.7
mmol/L Before Meal
After Meal
Event Tag

4. To add an Event tag to your result, press

5. Press or to highlight Event Tag, then press

6.7

mmol/L Before Meal

After Meal

Event Tag

61

4 Tagging results
6. Press or to highlight an Event tag, then press You may add more than one Event tag to a result. A notes that an Event tag has been added.
7. When you have finished selecting Event tags, highlight Done and press

6.7
mmol/L Carbs Stress Illness Done
6.7
mmol/L

Example
The result will be displayed with the tags. Pressing and holding will allow you to edit the tags.
NOTE: Use care when adding tags to blood glucose results. When you leave the result screen, the tags and result are stored in the Results Log and cannot be changed. Incorrect Meal tagging can cause the meter to identify inaccurate Before and After Meal averages and Patterns. Incorrect Event tagging can cause the meter to display incorrect Messages.

62

5 Understanding Messages 5
Blood Sugar MentorTM Messages overview The OneTouch Verio Reflect® Meter reviews your past test results and may display Mentor Tips (guidance), Pattern Messages (insight) or Awards (encouragement). The meter will show you the most appropriate Message if more than one is applicable to your result. 1. Mentor Tips appear when your results are consistently in
range or are currently trending low or high. 2. Pattern Messages appear when the meter identifies a
pattern of glucose results that fall outside the high and low range limits you set in the meter. 3. Awards are earned when certain Award criteria are met, such as meeting the Daily Test Goal or tagging results. Pressing will dismiss Messages.
63

5 Understanding Messages
Understanding Pattern Messages Low and High Pattern Messages appear when the meter identifies a Pattern of glucose results that fall outside the low and high mealtime range limits set in your meter. Every time you test your blood glucose, your OneTouch Verio Reflect® Meter searches for any new Patterns that have developed over the past 5 days. Patterns are identified by finding results below or above the low and high mealtime range limits set in your meter, and cross referencing with the time of day the tests were taken. For a set of results to form a Pattern, the results must be within the same 3-hour time period over the past 5 days. When a Pattern is identified, a Pattern message icon ( ) appears below your result. A Pattern Message will be displayed after the result screen. Inaccurate results may cause Pattern Messages to appear. Once a result is used in a Pattern, it will not be used again in future Pattern Messages.
64

Understanding Messages 5

Reviewing results that create Patterns
There are two ways you can review the individual results that combine to create a Low or High Pattern.
To view a Low or High Pattern message after a test, press .

3.1
mmol/L Before Meal
Low
Example – Results screen with Pattern icon

3.1

mmol/L

Pattern found

Treat Low. Low in the

last X days at this

time. Has anything

changed?

OK

Example – Pattern Message

To view the details about the individual blood glucose results that resulted in the Pattern, press
again.
Or you can access the Patterns using the Results Log screen. See page 75.

Low Pattern

mmol/L

Jun 11 12:05 am

3.1

Jun 9

12:01 am

3.6

Example – Results that created Low
Pattern

65

5 Understanding Messages
Low (or Hypo) Pattern Messages appear when any 2 results over the past 5 days are: · within the same 3-hour period · below your low mealtime range limits NOTE: Follow your healthcare professional’s advice for treating a low blood glucose result.
High Pattern Messages appear when any 3 results over the past 5 days are: · within the same 3-hour period · above your high mealtime range limits · share the same Meal tag Event tag Pattern Messages appear when any 3 results over the past 30 days are: · within the same 3-hour period · above or below your mealtime range limits · share the same Event tag
Lee-Davey, J., Alexander, S., & Raja, P. (2011, February 16). Clinical Patterns of Low Blood Glucose Identified by a Pattern Algorithm May Predict Increased Risk of Severe Hypoglycemia in the Following 24-Hour Period [PDF]. Inverness, Scotland: LifeScan.
66

Understanding Messages 5
NOTE: To be sure that Low and High Pattern Messages appear: · Basic Mode must be turned off and Pattern Messages
must be turned on. See page 93 and page 95. · Update the date and time if you change time zones,
or if the time changes due to Daylight saving time. · Test your blood glucose using only one OneTouch Verio
Reflect® Meter. Using multiple meters may cause you to miss Patterns. · Tag your blood glucose results carefully. · Test when you feel your blood glucose may be high or low.
CAUTION: · Always use your current result for immediate treatment
decisions. · Do Not use Pattern Messages to make immediate or
significant changes to your diabetes care plan without first consulting your healthcare professional. Always consult your healthcare professional before making significant changes to your diabetes care plan. · Do Not wait for Pattern Messages to treat low or high results. · Do Not allow other people to use your meter or your Patterns may be affected.
67

5 Understanding Messages
Understanding Mentor Tips
Mentor Tips let you know when your results are consistently in range, and display diabetes management information when results are trending low and high.
NOTE: Mentor Tips appear with current results and cannot be viewed later.
· Unusually Low – Current result is below the low range limit, and is at least 0.3 mmol/L below your lowest result over the past 14 days.
· Morning Low – Current result occurred in the morning and is below the low range limit.1
· Treat Low – Current result is below the low range limit.1, 2 · Unusually High – Current result is above the high range
limit, and is more than 10% higher than the highest blood glucose result in the last 14 days. · Morning High – Current result occurred in the morning and is above the high range limit.1 · Bedtime High – Current result occurred at night and is above the high range limit.1 · Congratulations – Your 90-day average is improving. · Trend 90 Rise – Your 90-day average has increased. · Trend 90 Update – New 90-day average is available. · Near Low – Result is in range but close to low range limit. · Near High – Result is in range but close to high range limit.
68

Understanding Messages 5
· Well Done – Result is back in range after a series of either 2 low or 3 high results.
· Keep It Up – More than 70% of results over the past 7 days were in range.
· Weekly Average – New 7-day average is shown. · Device Not Paired – Reminds you to pair the meter with a
compatible wireless device. · Connect Device – Reminds you to sync the meter with
the App. · Exercise Low – Current result is below the low range limit
and received an Exercise Event tag.3, 4 · Take a Break – Current result is above the high range limit
and received a Stress Event tag.4
1Riddle, M. C., MD (Ed.). (2018). 6. Glycemic Targets: Standards of Medical Care in Diabetes 2018 [Abstract]. Diabetes Care, 41 (Suppl. 1), S60-61. 2American Association of Diabetes Educators. (2018). HYPOGLYCEMIA What are the symptoms? And how should I treat it? [Brochure]. Chicago, IL: Author. 3American Association of Diabetes Educators. (2017). AADE7 Self-Care Behaviors, Problem Solving [Brochure]. Chicago, IL: Author. 4Riddle, M. C., MD (Ed.). (2018). 6. Glycemic Targets, S44-45.
69

5 Understanding Messages
Understanding Awards The OneTouch Verio Reflect® Meter tracks the goals outlined below. Each time you earn bronze ( ), silver ( ) or gold ( ) medal status, an Award will appear along with your in-range result. You can review your Awards later in the Summary. (See page 71.) · Test Goal Award – Meet your Daily Test Goal a set
number of times in total or in a row. · In-Range Award – Achieve an in-range result a set
number of times in a row. · Event Tag Award – Event tag your result a set number of
times in total. · Syncing Award – Sync your meter to the
OneTouch Reveal® App a set number of times in total.
70

6 Summary, Results Log and Trend 90 6
Viewing the Summary Depending on settings selected the Summary may display results by range, time of day, averages, mealtime averages, Test Tracker progress and Awards. You and your healthcare professional can reference the Summary to identify overall trends in your diabetes management.
NOTE:
· Do Not use result averages to make immediate treatment decisions. Result averages provide information from past results. Always consult your healthcare professional before making significant changes to your diabetes care plan.
· Do Not allow other people to use your meter as it may affect your averages.
· The meter calculates averages based on the 7-, 14- and 30-day periods ending on the current date setting. If you change the date setting, the averages may change too.
· The Summary screens displayed will reflect the features currently selected. See page 88 for information on turning meter features on or off.
· If Basic Mode is selected, your Summary will be limited to the 30-day Summary and Average views. See page 29 for more information about Basic Mode.
71

6 Summary, Results Log and Trend 90
· In Averages, Pattern Messages and Awards, an EXTREME HIGH GLUCOSE result is always counted as 33.3 mmol/L, and an EXTREME LOW GLUCOSE result is always counted as 1.1 mmol/L.
· The green progress dot will move from left to right as you navigate through the summary screens.

Progress dot

· Pressing will display the previous screen.

1. From the Main Menu, press or to highlight Summary and press
The number of results that are low (blue), in-range (green) and high (red) are displayed and appear as bar graphs.

May 2

9:31 am

Summary

Results Log

Trend 90

Settings

Summary Last 30 days
70

23 15

Example
72

Summary, Results Log and Trend 90 6

2. Press to display the Summary by time of day
The number of test results that are low, in-range and high, by time of day are displayed. The four time slots are Morning, Afternoon, Evening and Bedtime. The time frames for the four time slots cannot be changed.

Summary Last 30 days
Lo In Hi 33
10 2 111 333
Example

Morning
Afternoon Evening

6:00 am to 11:59 am 12:00 pm to 5:59 pm 6:00 pm to 11:59 pm

Bedtime

12:00 am to 5:59 am

NOTE: If there were no results in the past 30 days in a target range and time period, that section of the chart is left blank.

73

6 Summary, Results Log and Trend 90

3. Press to display your overall averages for the past 7, 14 and 30 days
4. If Basic Mode is off, press to display your Before Meal averages for the past 7, 14 and 30 days
5. If Basic Mode is off, press to display your After Meal averages for the past 7, 14 and 30 days NOTE: If you do not have results in the past 7-, 14- and 30-day periods, dashes will appear in the mmol/L column.

Averages mmol/L

7 Days 14 Days 30 Days

8.9 10.0 11.1

Example

Before Meal Avg. mmol/L

7 Days

11.1

14 Days

30 Days

Example

After Meal Avg. mmol/L

7 Days 14 Days 30 Days

8.9 10.0 11.1

Example

74

Summary, Results Log and Trend 90 6

6. If Test Tracker is on, press to display the Daily Test Goal screens

Summary Test Tracker
4 out of 8 test(s) completed today.

7. If Awards is on, press to display the Award screens

Example
Award In-Range Award

Gold level You’ve been in range
30 times in a row!

Example
Viewing the Results Log
Using the Results Log, you can review the most recent 750 results.
See page 3 for definitions of meter icons that may appear with your result.
Pressing and releasing will allow you to view the previous screen.

75

6 Summary, Results Log and Trend 90

1. From the Main Menu, press or to highlight Results Log and press
Up to four results are displayed on the screen, starting with the most recent.
2. Press or to move through the list of results NOTE: If a result is part of a Pattern, the Pattern icon will be displayed for that result instead of any tags that result may have.

May 2

9:31 am

Summary

Results Log

Trend 90

Settings

Results Log

mmol/L

Mon, Jun 11

6:05 pm 16.9

12:05 am 3.1

Sun, Jun 10

7:05 pm

8.3

Example

Results Log

mmol/L

Mon, Jun 11

6:05 pm 16.9

12:05 am 3.1

Sun, Jun 10

7:05 pm

8.3

Example

76

Summary, Results Log and Trend 90 6

3. Highlight a result with an icon and press
The result screen will be displayed along with the date and time the result was taken and any tag, Pattern or Range Indicator icons. If you are uncertain whether the result you are viewing is your most current result, view the date and time on the screen.
If the result is part of a Pattern, indicated by , pressing again will display the results that led to the Pattern. See page 64 for more information about Patterns.

Jun 11 12:05 am
3.1
mmol/L Before Meal
Low
Example

Low Pattern

mmol/L

Jun 11

12:05 am

3.1

Jun 9 12:01 am

3.6

Example

77

6 Summary, Results Log and Trend 90

Viewing the Trend 90
The OneTouch Verio Reflect® Meter averages results over the past 90 days to provide a view of the overall trend of blood glucose results. There must be at least 90 days of results stored in the meter for the first 90-day average to appear. A point will be graphed on the screen to represent the first 90-day average. After the first 90-day average a new point is displayed every 14 days.

NOTE:
· Basic Mode must be turned off to use the Trend 90 feature. (See page 93.)
· The Trend 90 is an average of blood glucose results. Always use your current result for immediate treatment decisions.

1. From the Main Menu, press or to highlight Trend 90 and press

May 2

9:31 am

Summary

Results Log

Trend 90

Settings

78

Summary, Results Log and Trend 90 6
The current 90-day average will be displayed as a blood glucose value with the unit of measure. Each point on the graph represents a 90-day average automatically generated every 14 days. You can track your Trend 90 visually by following the path of points along the graph.

Trend 90

5.9 Current Avg.

1

mmol/L
15.2

4

3

5.8

2

Example

1 Current 90-day average 2 Newest average point 3 90 Day Average Target set in
the meter 4 Oldest average point

2. Press to return to the Main Menu

79

7 Syncing your meter

Connecting to a compatible wireless device
Turning the BLUETOOTH® feature on or off
In order to connect your meter with your compatible wireless device, the BLUETOOTH® feature will need to be turned on. The symbol will appear on the meter screen when the BLUETOOTH® feature is on. When the symbol is not present on the screen the BLUETOOTH® feature is off.

1. Start by turning your meter on using the Wait for the Main Menu to appear, then press highlight Settings and press

button or to

2. On the Settings Menu, highlight Bluetooth and press

Settings
Time/Date Language Range/90d Features Messages Bluetooth

80

Syncing your meter 7

A notes if BLUETOOTH® is currently set to On or Off.

Bluetooth
On Off
Turn On to connect with the OneTouch Reveal mobile app. OneTouch 4444.

3. Press or to highlight On or Off and press
NOTE: The BLUETOOTH® feature will turn OFF during a blood glucose test.
Pairing overview
Pairing allows your OneTouch Verio Reflect® Meter to communicate with compatible wireless devices. The devices must be within 8 meters of each other to pair and sync. Download the OneTouch Reveal® Mobile App from the App Store or on Google Play before pairing your meter and compatible wireless device.

81

7 Syncing your meter Apple, App Store, and the Apple Logo are trademarks of Apple Inc. registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google LLC. Multiple OneTouch Verio Reflect® Meters can be paired with your compatible wireless device. For example, your compatible wireless device can be paired with a meter at home and another at work. To pair multiple meters, repeat the pairing instructions for each meter. See page 83 for pairing instructions.
82

Syncing your meter 7

Your OneTouch Verio Reflect® Meter can be paired with multiple compatible wireless devices. To pair multiple compatible wireless devices, repeat the pairing instructions for each compatible wireless device.

Pairing instructions
The BLUETOOTH® feature must be turned on in order to pair the meter with the app. See page 80.
1. Open the OneTouch Reveal® Mobile App and follow instructions to pair the meter with your compatible wireless device

2. Look for “OneTouch” and the last 4 characters of the meter serial number on the compatible wireless device display to correctly identify your meter
The meter screen will display the pairing info to look for on your compatible wireless device.

Take Note
Now use the OneTouch Reveal mobile app and select OneTouch 4444.
OK
Example

83

7 Syncing your meter 3. When prompted by the OneTouch Reveal® Mobile App, the meter will display a six digit PIN number

Bluetooth PIN
453201

Cancel
Example PIN
Enter the PIN number into your compatible wireless device using the keypad.
CAUTION: Make sure the PIN you enter on your compatible wireless device matches the PIN on your meter display. If a PIN number unexpectedly appears on your meter display, cancel the PIN request by either inserting a test strip to take a test or press the button to cancel.
4. Wait for your compatible wireless device to indicate that it is paired with your meter
Sending your results to the app If the BLUETOOTH® feature on the meter is turned on, indicated by the BLUETOOTH® symbol ( ), the meter will automatically send your results to any paired compatible wireless device.

84

Syncing your meter 7
The Sync symbol ( ) flashes on the meter display. After syncing, the Sync symbol will disappear and the app will display a list of any new results sent from the meter. You can then share your results with your caregiver or healthcare professional.
CAUTION: Always use the current result on your meter for immediate treatment decisions. NOTE: The compatible wireless device must have the app open and have already been paired to the meter before sending a result. See page 81. NOTE: If the BLUETOOTH® feature on the meter is turned off, or the meter is out of range, the result is not sent to the compatible wireless device. The result is saved in the meter memory with the current date and time, and will be sent to the app the next time you sync. The sent results are also stored in the meter. To sync, the app must be open and running on your compatible wireless device. To ensure that glucose test results are successfully sent to the app, turn on the BLUETOOTH® feature and check the following: · The compatible wireless device and meter are both
turned on, and the app is running.
85

7 Syncing your meter
· The meter is correctly paired with your compatible wireless device.
· The BLUETOOTH® feature on both devices is running (indicated by ) and the devices are within 8 meters of each other.
· The meter will attempt to transmit results up to 4 hours after a test, even if the meter appears to be off.
If you are still unable to send results to the compatible wireless device, try un-pairing and re-pairing with the device, moving the meter and compatible wireless device closer together, or relocating them from possible sources of interference. If you continue to have difficulties, please call Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet. Please address any app issues to the app customer care department. NOTE: · Inserting a test strip during the transmission will cancel
the transfer of all results. The Apply Blood screen appears and you can proceed with testing. · Keep your meter in your care to avoid inaccurate results from being sent to your compatible wireless device.
86

Syncing your meter 7

Downloading results to a computer

Your meter can work with diabetes management software, which provides a visual way to track key factors that affect your blood sugar. To learn more about diabetes management tools available to you, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

Connect only to a computer certified to UL 60950-1 ( ).

To transfer meter data, follow the instructions provided with the diabetes management software product to download the results from the meter. You will need a standard micro USB interface cable to connect your OneTouch Verio Reflect® Meter to a computer to download results (not included).

Once the command to start the download is sent from the computer to the meter, the Cable Connected screen will appear, indicating that the meter is in communication mode.

Do Not insert a test strip while the meter is connected to a computer.
If you are unable to download your results to a computer, please call Customer Care.

Cable Connected

87

8 Adjusting meter settings

Settings Menu overview
After first time setup, you can use the Settings Menu to adjust the meter settings and access additional features.

Time/Date Language Range/90d
Features
Messages
Bluetooth Control Test Meter Info

Set the time and date
Set the language displayed on screens
· Set Before Meal limits · Set After Meal limits · Set the 90 Day Average Target
· Turn Basic Mode on or off · Turn Test Tracker on or off · Set Daily Test Goal · Set Range Indicator icon to emoji or text
· Turn Pattern Messages on or off · Turn Mentor Tips on or off · Turn Awards on or off
Turn the BLUETOOTH® feature on or off
Initiate a control solution test
View meter serial number, software version and last sub-error code

NOTE: For information on Bluetooth, see page 9. For information on Control Test, see page 53.

88

Adjusting meter settings 8

Navigating to the Settings Menu

From the Main Menu, press or to highlight Settings and press

May 2

9:31 am

Summary

The Settings Menu is displayed.

Results Log

Trend 90

Settings

Adjusting the time and date
You can change the time and date setting whenever needed, such as during travel.
NOTE: Adjusting this setting to a time and date prior to your last blood glucose or control solution test will cause the Results Log to appear out of sequence. The Results Log will display results in the order in which they were taken.

89

8 Adjusting meter settings

1. From the Settings Menu, press or Time/Date and press 2. Highlight the time or date and press 3. Adjust the desired setting and press Repeat this step as necessary.

to highlight

Adjusting the language 1. From the Settings Menu, press or to highlight Language and press
A appears next to the current language set in the meter. 2. Highlight the desired language, then press
The Settings Menu will be displayed in the new language you have selected.

Adjusting range limits and 90 Day Average Target
NOTE:
· If you adjust your range limits, your previous Range Indicator icons in the Results Log will not change. Only new results will be affected by your range limit changes.
· Consult with your healthcare professional about the range limits and 90 Day Average Target that are right for you.

90

Adjusting meter settings 8

1. From the Settings Menu, press or to highlight Range/90d (or Range for Basic Mode) and press Your current meter settings are displayed.

Range/90d
Before Meal 3.9­7.2 mmol/L
After Meal 3.9­10.0 mmol/L
90d Target 8.6 mmol/L
Example – Basic Mode Off

Range Range 3.9­10.0 mmol/L
Example – Basic Mode On

2. Highlight the range setting to be adjusted and press

3. Adjust the Low Limit and press

Before Meal mmol/L

3.9 ­ 7.2
Low Limit

Example – Before Meal

91

8 Adjusting meter settings

Repeat this step to change the High Limit. See page 22 for information about Before and After Meal low and high limits.
NOTE: In Basic Mode, range limits are general and are not defined by mealtime. General range limits are pre-set.

General range limits

pre-set low limit pre-set high limit low limit must be set within high limit must be set within

4.0 mmol/L 10.0 mmol/L 3.3 mmol/L and 6.1 mmol/L 5.0 mmol/L and 16.7 mmol/L

4. To adjust the 90 Day Average Target, highlight the 90d Target setting and press

5. Adjust the 90 Day Average Target and press

Trend 90 mmol/L

8.6
Consult your HCP before setting your
90d avg. target.

92

Adjusting meter settings 8
The meter is pre-set with a 90 Day Average Target of 8.6 mmol/L. The minimum 90 Day Average Target is 5.5 mmol/L and the maximum is 14.7 mmol/L. NOTE: Be sure to talk to your healthcare professional about the 90 Day Average Target that is right for you.
Turning Basic Mode on or off NOTE: Selecting Basic Mode affects the information the meter displays. See page 29 for more information. 1. From the Settings Menu, press or to highlight Features and press The Features Menu indicates whether Basic Mode is currently on or off. 2. Highlight Basic Mode and press A appears next to the current mode set in the meter. 3. Highlight On or Off and press In Basic Mode, Test Tracker and Range Indicator are removed from the Features Menu.
93

8 Adjusting meter settings
Basic Mode uses pre-set general range limits which are different from the ones set during first time setup. See page 90 for information on adjusting range limits.
Turning the Test Tracker on or off and setting a Daily Test Goal 1. From the Settings Menu, press or to highlight Features and press The Features Menu indicates the current Test Tracker setting. NOTE: If Basic Mode is selected the Test Tracker will not appear in the Features Menu. 2. Highlight Test Tracker and press 3. Adjust the Daily Test Goal, then press The meter is pre- set with a Daily Test Goal of four tests per day. The maximum Daily Test Goal is eight. NOTE: Be sure to talk to your healthcare professional about the Daily Test Goal that is right for you. To turn off the Test Tracker, press or until Off is highlighted, and press .
94

Adjusting meter settings 8
Set the Range Indicator icon to emoji or text 1. From the Settings Menu, press or to highlight Features and press Your current meter settings are displayed. 2. Highlight Range Indicator and press A appears next to the current setting in the meter. 3. Highlight Emoji or Text, then press
Turning Pattern Messages, Mentor Tips and Awards on or off NOTE: · Basic Mode must be turned off for the Messages Menu to
appear in Settings. See page 93. · If Pattern Messages are turned off, you will no longer see
Patterns with results, Summary or Results Log screens. The meter will continue to track Pattern information. If you turn Pattern Messages back on again, Pattern icons will be displayed in the Summary and Results Log. See page 64 for more information about Pattern Messages.
95

8 Adjusting meter settings
· If Mentor Tips are turned off, you will no longer see Mentor Tips with results. See page 68 for more information about Mentor Tips.
· If Awards are turned off, you will no longer see Awards with results or in the Summary view. See page 70 for more information about Awards.
1. From the Settings Menu, press or to highlight Messages and press Your current meter settings are displayed. 2. Highlight Pattern, Mentor Tips or Awards and press A appears next to the current setting in the meter. 3. Highlight On or Off and press
View meter info and last sub-error code The meter serial number, software version, and information about the last meter sub-error are stored in your meter. You can check this information at any time and use it for troubleshooting.
96

Adjusting meter settings 8

1. From the Settings Menu, press or to highlight Meter Info
and press The meter serial number, software version, and unit of measure are displayed.
2. Press to view information about the last meter error

Meter Info Serial Number: ABC12345 Software: PUE_01.01.00 Units: mmol/L
Example
Meter Info Last Error: Error X Error Date: Aug 30 2018 Sub-Error Code: XXXX
Example

Pressing returns you to the Settings Menu.

97

9 Caring for your system
Storing your system Store your meter, test strips, control solution and other items in your carrying case. Keep in a cool, dry place between 5°C and 30°C. Do Not refrigerate. Keep all items away from direct sunlight and heat. Exposure to temperatures outside the storage limits, as well as moisture and humidity, may cause inaccurate readings. Cleaning and disinfection Cleaning and disinfection are different and both should be performed. Cleaning is part of your normal care and maintenance and should be performed prior to disinfection, but cleaning does not kill germs. Disinfection is the only way to reduce your exposure to disease. For cleaning information, see page 99, and for disinfection, see page 100.
98

Caring for your system 9
Cleaning your meter, lancing device and cap The meter, lancing device and cap should be cleaned whenever they are visibly dirty and before disinfection. Clean your meter at least once per week. For cleaning obtain regular strength liquid dish soap and a soft cloth. Prepare a mild detergent solution by stirring 2.5 mL of regular strength liquid dish soap into 250 mL of water. · Do Not use alcohol or any other solvent. · Do Not allow liquids, dirt, dust,
blood or control solution to enter the test strip port or the data port. (See page 16.) · Do Not spray cleaning solution on the meter or immerse it in any liquid.
99

9 Caring for your system
1. Holding the meter with the test strip port pointed down, use a soft cloth dampened with water and mild detergent to wipe the outside of the meter and lancing device Be sure to squeeze out any excess liquid before you wipe the meter. Wipe the outside of the cap. 2. Wipe dry with a clean, soft cloth
Disinfecting your meter, lancing device and cap The meter, lancing device and cap should be disinfected periodically. Clean your meter, lancing device and cap prior to disinfecting. For disinfecting, obtain regular household bleach (containing a minimum of 5.5% sodium hypochlorite as the active ingredient). Prepare a solution of 1 part household bleach and 9 parts water or obtain equivalent (0.55% sodium hypochlorite) wipes. *Follow manufacturer’s instruction for handling and storage of bleach.
100

Caring for your system 9
1. Hold the meter with the test strip port pointed down Use a soft cloth dampened with this solution or a 0.55% equivalent sodium hypochlorite wipe to wipe the outside of the meter and lancing device until the surface is damp. Be sure to squeeze out any excess liquid before you wipe the meter.
2. After wiping, cover the surface you are disinfecting with the soft cloth dampened with the bleach solution or 0.55% equivalent sodium hypochlorite wipe for 1 minute Then wipe with a clean, damp, soft cloth. Wash hands thoroughly with soap and water after handling the meter, lancing device and cap. If you see signs of wear, please contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.
101

10 Batteries
Replacing the batteries Your OneTouch Verio Reflect® Meter uses 2x CR2032 lithium batteries. One battery powers the meter only and the other powers the backlight. See page 111 for information on when to change the meter batteries. If the meter does not turn on, or remains dim after pressing a button, check the batteries. Do Not change the batteries when connected to a PC.
WARNING: CHEMICAL BURN HAZARD. DO NOT INGEST BATTERY. This product contains a coin/button cell battery. If swallowed, it can quickly cause severe internal burns and can lead to death. Keep new and used batteries away from children. If you think batteries might have been swallowed, seek immediate medical attention. IMPORTANT: Use only CR2032 lithium batteries with your meter. Do Not use rechargeable batteries. Use of an incorrect battery type or a used battery may result in your meter providing fewer tests than normal.
WARNING: Certain batteries may cause leaking, which can damage the meter or cause the batteries to lose power sooner than normal. Replace leaking batteries immediately.
102

1. Remove the old batteries
Start with the meter turned off. Remove the battery cover by pressing and sliding it downward.

Batteries 10

Pull up firmly on the plastic ribbons. The plastic ribbon with the
symbol is for the meter battery, and the plastic ribbon with the symbol is for the backlight battery. Always change both batteries at the same time.
2. Insert the new batteries With the “+” side facing up toward you, place each battery in the compartment within the fold of the plastic ribbon. Push each battery in until it snaps into the battery clasp.
103

10 Batteries
Replace the battery cover by sliding it upwards onto the meter. If the meter does not power on after you have replaced the batteries, check that the batteries are correctly installed with the “+” side up. If the meter still does not power on, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet. 3. Check your meter settings You will be prompted to set the time and date whenever you change the batteries. See page 89. 4. Dispose of batteries Dispose of batteries according to your local environmental regulations.
104

11 Troubleshooting 11

Error and other messages
The OneTouch Verio Reflect® Meter displays messages when there are problems with the test strip, with the meter or when your glucose levels are above 33.3 mmol/L or below 1.1 mmol/L. Improper use may cause an inaccurate result without producing an error message.
NOTE: If the meter is on but does not operate (locks up), contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

What it means

Warning

You may have a very low blood glucose level (severe hypoglycemia), below 1.1 mmol/L.

EXTREME LOW GLUCOSE
Below 1.1 mmol/L

What to do This may require immediate

Treat Low

treatment. Although this message

could be due to a test error, it is safer

to treat first and then do another test.

Always treat according to your healthcare professional’s

recommendations.

105

11 Troubleshooting

What it means
You may have a very high blood glucose level (severe hyperglycemia), over 33.3 mmol/L.
What to do

Warning
EXTREME HIGH GLUCOSE
Above 33.3 mmol/L

Re-test your blood glucose level. If the result is EXTREME HIGH GLUCOSE again, obtain and follow instructions from your healthcare professional right away.

What it means

Warning

Meter is too hot (above 44°C) to perform a test.

Temperature too high. Out of operating

What to do

range. See Owner’s Booklet.

Move the meter and test strips to a

cooler area. Insert a new test strip

when the meter and test strips

are within the operating range

(6-44°C). If you do not get another

Temperature too high message, you can proceed with

testing.

If this message continues to appear, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

106

Troubleshooting 11

What it means Meter is too cold (below 6°C) to perform a test.
What to do

Warning
Temperature too low. Out of operating
range. See Owner’s Booklet.

Move the meter and test strips to a warmer area. Insert a new test strip when the meter and test strips are within the operating range (6-44°C). If you do not get another Temperature too low message, you can proceed with testing.

If this message continues to appear, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

Error Screens
If there is a problem with the meter, the following error screens may appear. If you cannot resolve the error with your meter, contact Customer Care. They will refer to the error number, and a sub-error code found in the Meter Info screen, to help troubleshoot the problem. See page 96 for more information on viewing the Meter Info screen.

107

11 Troubleshooting

What it means
There is a problem with the meter.
What to do
Do Not use the meter. Contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

Error 1
Meter problem. Contact customer
service.

What it means
Error message could be caused by a used test strip, applying blood to the test strip before inserting it into the meter or a problem with the meter or test strip.

Error 2
Meter or strip problem. Retest with
a new strip.

What to do

Repeat the test with a new test strip; see page 31 or page 53. If this message continues to appear, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

108

Troubleshooting 11

What it means
The sample was applied before the meter was ready.
What to do

Error 3
Meter was not ready. Retest with a new strip.

Repeat the test with a new test strip. Apply a blood or control solution sample only after the Apply Blood or Apply Control Solution screen appears on the display. If this message continues to appear, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

What it means

Error 4

One of the following may apply:
· Not enough blood or control solution was applied or more was added after the meter began to count down.

Strip fill problem. Retest with a new strip.

· The test strip may have been damaged or moved during testing.

· The sample was improperly applied.

· There may be a problem with the meter.

109

11 Troubleshooting
What to do Repeat the test with a new test strip; see page 31 or page 53. If the error message appears again, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

What it means
The meter has detected a problem with the test strip. Possible cause is test strip damage.

Error 5
Strip problem. Retest with a new strip.

What to do

Repeat the test with a new test strip; see page 31 or page 53. If the error message appears again, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

110

Troubleshooting 11

What it means
Battery power is low but there is still enough battery power to perform a test. Test results will still be accurate. The flashing low battery ( ) icon will continue to appear until the batteries are replaced.
What to do
Press to continue, but replace the batteries as soon as possible.

Be advised
Low Battery. Replace soon.
2 x CR2032
OK

What it means There is not enough meter battery power to perform a test.
What to do Replace the batteries immediately.

Warning
Battery Empty. Replace now. 2 x CR2032

111

12 System information
Comparing meter results to laboratory results Results obtained from the OneTouch Verio Reflect® Meter and laboratory tests are reported in plasma- equivalent units. However, your meter result may differ from your lab result due to normal variation. A result from your OneTouch Verio Reflect® Meter is considered accurate when it is within 0.83 mmol/L of a laboratory method when the glucose concentration is lower than 5.55 mmol/L and within 15% of a laboratory method when the glucose concentration is 5.55 mmol/L or higher.
Meter results can be affected by factors that do not affect lab results in the same way. Specific factors that may cause your meter result to vary from your lab result may include: · You have eaten recently. This can cause a result from
fingertip testing to be up to 3.9 mmol/L higher than a lab test using blood drawn from a vein.1 · Your hematocrit is above 60% or below 20%. · You are severely dehydrated.
For additional information, refer to the OneTouch Verio® Test Strip Insert.
1Sacks, D.B.: “Carbohydrates.” Burtis, C.A., and Ashwood E.R. (ed.), Tietz Textbook of Clinical Chemistry, Philadelphia: W.B. Saunders Company (1994), 959.
112

System information 12
Guidelines for obtaining an accurate meter to lab comparison Before going to the lab: · Perform a control solution test to make sure your meter is
working properly. · Do Not eat for at least 8 hours before you test your
blood. · Take your meter and testing supplies with you to the lab.
Testing with your OneTouch Verio Reflect® Meter at the lab: · Test within 15 minutes of the lab test. · Use only a fresh, capillary blood sample from your
fingertip. · Follow all instructions in this Owner’s Booklet for
performing a blood glucose test.
Comparing your meter results to those taken from another meter Comparing your blood glucose test results taken with this meter to your results taken from a different meter is not recommended. Results may differ between meters and are not a useful measure of whether your meter is working properly.
113

12 System information

Technical specifications

Assay method
Automatic shutoff Battery ratings Battery type BLUETOOTH® technology
Calibration Data port type Memory

FAD-GDH (flavin adenine dinucleotide dependent glucose dehydrogenase)
Two minutes after last action
Two 3.0 V d.c., (2x CR2032 batteries), 15 mA
2 replaceable 3.0 Volt CR 2032 lithium batteries (or equivalent)
Frequency range: 2.4-2.4835 GHz Maximum power: 0.4 mW Operating Range Distance: minimum 8 meters (unobstructed) Operating Channels: 40 Channels Security Encryption: 128-bit AES (Advanced Encryption Standard)
Plasma-equivalent
Compatible with micro USB 2.0
750 test results

114

System information 12

Operating ranges
Reported result range Sample Sample volume Size Test time Unit of measure Weight

6-44°C Relative humidity: Non-condensing 10-90% Altitude: up to 3048 meters Hematocrit: 20-60%
1.1-33.3 mmol/L
Fresh capillary whole blood
0.4 µL
43.0(W) x 101.0(L) x 15.6(T) mm
Approximately 5 seconds
mmol/L
Approximately <53 grams

115

12 System information

System accuracy
Diabetes experts have suggested that 95% of glucose meter results should agree within 0.83 mmol/L of a laboratory method when the glucose concentration is lower than 5.55 mmol/L, and within 15% of a laboratory method when the glucose concentration is 5.55 mmol/L or higher.
Samples from 100 patients were tested using both the OneTouch Verio Reflect® System and the YSI 2900 Glucose Analyzer laboratory instrument.

System accuracy results for glucose concentrations <5.55 mmol/L
Percent (and number) of meter results that match the laboratory test

Within ±0.28 mmol/L 73.7% (137/186)

Within ±0.56 mmol/L 96.8% (180/186)

Within ±0.83 mmol/L 100% (186/186)

116

System information 12

System accuracy results for glucose concentrations 5.55 mmol/L
Percent (and number) of meter results that match the laboratory test

Within ±5% 65.2% (270/414)

Within ±10% 93.2% (386/414)

Within ±15% 99.3% (411/414)

System accuracy results for glucose concentrations between 1.9 mmol/L and 25.0 mmol/L
Within ±0.83 mmol/L or ±15% 99.5% (597/600)
NOTE: Where 1.9 mmol/L represents the lowest glucose reference value and 25.0 mmol/L represents the highest glucose reference value (YSI value).

117

12 System information

Regression statistics
Samples were tested in duplicate on each of three test strip lots. Results indicate that the OneTouch Verio Reflect® System compares well with a laboratory method.

of Subjects # of Tests

100

600

Slope 1.02

Intercept (mmol/L)
0.04

95% CI Slope 95% CI Std. Error

R2

Intercept (mmol/L)

(Sy.x) (mmol/L)

1.01 to 1.03 -0.03 to 0.11

0.49

0.99

User performance accuracy
A study evaluating glucose values from fingertip capillary blood samples obtained by 313 lay persons showed the following results:
97.1% within ±0.83 mmol/L of the medical laboratory values at glucose concentrations below 5.55 mmol/L, and 96.4% within ±15% of the medical laboratory values at glucose concentrations at or above 5.55 mmol/L.
96.5% of the total number of samples were within ±0.83 mmol/L or ±15% of the medical laboratory values.

118

System information 12

Precision
Within Run Precision (300 Venous Blood Samples Tested per Glucose Level)
Data generated using the OneTouch Verio Reflect® Meter.

Target Glucose (mmol/L)

Mean Glucose (mmol/L)

Standard Deviation (mmol/L)

Coefficient of Variation
(%)

2.2

2.2

0.06

2.68

5.0

4.9

0.13

2.66

7.2

7.1

0.21

2.98

11.1

11.2

0.31

2.73

19.4

19.8

0.52

2.60

Results show that the greatest variability observed between test strips when tested with blood is 0.13 mmol/L SD or less at glucose levels less than 5.55 mmol/L, or 2.98% CV or less at glucose levels at 5.55 mmol/L or above.

119

12 System information

Total Precision (600 Control Solution Tests per Glucose Level)
Data generated using the OneTouch Verio Reflect® Meter.

Glucose Level Ranges
(mmol/L)
Low (1.39-2.72)
Mid (5.67-7.67)
High (16.56-22.39)

Mean Glucose (mmol/L)
2.13 6.70 19.34

Standard Deviation (mmol/L)

Coefficient of Variation
(%)

0.07

3.3

0.15

2.2

0.46

2.4

Guarantee
LifeScan guarantees that the OneTouch Verio Reflect® Meter will be free of defects in material and workmanship for three years, valid from the date of purchase. The guarantee extends only to the original purchaser and is not transferable. If the meter stops working or a defect occurs on any part, contact Customer Care. Contact information for Customer Care is listed at the end of this Owner’s Booklet.

120

System information 12
Electrical and safety standards This meter complies with CISPR 11:Class B (Radiated Only). Emissions of the energy used are low and not likely to cause interference in nearby electronic equipment. The meter has been tested for immunity to electrostatic discharge as specified in IEC 61326-2-6. This meter complies with immunity to radio frequency interference as specified in IEC 61326-1 and 61326-2-6. The meter meets the requirements for immunity to electrical interference at the frequency range and test level specified in international standard EN 60601-1-2:2014. Do Not use the equipment where aerosol sprays are being used, or when oxygen is being administered.
121

13 Index
90 Day Average Target………………………………………………. 28, 90 After Meal range limits………………………………………………..27, 90 After Meal tag …………………………………………………………………….60 AST ……………………………………………………………………………………..35 Awards……………………………………………………………. 19, 63, 70, 95 Basic Mode…………………………………………………………………..29, 93 Batteries, replacing………………………………………………………… 102 Battery low icon……………………………………………………………5, 111 Before Meal range limits …………………………………………… 26, 90 Before Meal tag………………………………………………………………….60 Blood Sugar MentorTM Messages…………………………………19, 63 BLUETOOTH®……………………………………………………9, 11, 80, 84 Buttons on meter ……………………………………………………………… 17 Cleaning your meter, lancing device and cap…………………99 Color Bar…………………………………………………………………….. 20, 44 ColourSure® Dynamic Range Indicator ……… 20, 26, 44, 46 Comparing meter results to laboratory results……………..112 Control solution ………………………………………………………………..53 Control solution, discard and expiration dates……………….52 Control solution, testing ………………………………………52, 57, 59 Daily Test Goal setting ………………………………………………..27, 94 Data port……………………………………………………………………………. 17 Date setting………………………………………………………………………..24 Dehydration………………………………………………………………. 47, 112 Disinfecting your meter, lancing device and cap………… 100 Display check ……………………………………………………………………. 21 Disposal, lancets and test strips ………………………………………. 51 Downloading results to a computer………………………………..87 Emoji…………………………………………………………………………………..95 Error messages ………………………………………………………………..105
122

Index 13
Event tagging …………………………………………………………………….60 EXTREME HIGH GLUCOSE message ……………………….48, 106 EXTREME LOW GLUCOSE message………………………….47, 105 Features ……………………………………………………………………… 94, 95 Fingertip testing procedure……………………………………………… 31 First time setup ………………………………………………………………….22 General range limits………………………………………………………….92 Guarantee ………………………………………………………………………. 120 Hyperglycemia………………………………………………………….48, 106 Hypoglycemia……………………………………………………………47, 105 Icons …………………………………………………………………………………3, 6 Infection, reduce the chance……………………………………………36 Intended use…………………………………………………………………………7 Kit components ………………………………………………………………… 13 Lancet…………………………………………………………………………..35, 37 Lancet, expiration date……………………………………………………..36 Lancing device………………………………………………..13, 35, 37, 99 Language……………………………………………………………………. 23, 90 Meal tagging………………………………………………………………………60 Mealtime range limits………………………………………………….25, 26 Mentor Tips……………………………………………………. 19, 63, 68, 95 Messages ……………………………………………………………………. 64, 95 mmol/L ……………………………………………………………………….17, 115 Pairing ………………………………………………………………………….81, 83 Pattern Messages ………………………………………….. 19, 63, 64, 95 Patterns………………………………………………………………………. 64, 65 PIN ………………………………………………………………………………………84 Plasma calibration ………………………………………………….. 112, 114 Range Indicator icon……………………… 3, 5, 17, 29, 44, 46, 61, …………………………………………………………………. 77, 88, 90, 94, 95
123

13 Index
Range limits ……………………………………………………………………….90 Serial number…………………………………………………………………….96 Settings ……………………………………….22, 88, 89, 90, 93, 94, 95 Settings Menu ……………………………………………………………………89 Software, diabetes management……………………………………..87 Software version………………………………………………………………..96 Storing your system…………………………………………………………..98 Sub-error code ………………………………………………………………….96 Summary …………………………………………………………………….. 71, 75 Symbols ……………………………………………………………………………3, 6 Syncing ………………………………………………………………………………84 Technical specifications………………………………………………….114 Temperature …………………………………31, 59, 98, 106, 107, 115 Test principle………………………………………………………………………. 8 Test strip…………………………………………………………………18, 39, 53 Test strip, applying drop of blood …………………………………… 41 Test strip, discard and expiration dates……………………………32 Test strip, silver prongs…………………………………………………….. 18 Test Tracker……………………………………………………. 20, 27, 45, 94 Time setting……………………………………………………………………….89 Trend 90……………………………………………………………………… 20, 78 Turning meter off ………………………………………………………………30 Turning meter on ………………………………………………….21, 39, 53 Unexpected results……………………………………………………..47, 49 Unit of measure ………………………………………………………….17, 115 Unusual red blood cell count (hematocrit)…………… 112, 115 Welcome screen……………………………………………………………….. 21
124

Contact the OneTouch® Customer Care Line at 1 800 663-5521, Monday-Friday, 9am-8pm Eastern, 6am-5pm Pacific, or visit www.OneTouch.ca. Meter Made in China Manufactured by: LifeScan Europe GmbH Dammstrasse 19 6300 Zug Switzerland Patent https://www.onetouch.com/patents
OneTouch® AW 07200003A © 2018­2023 LifeScan IP Holdings, LLC Rev. Date: 01/2023

Système de surveillance de la glycémie
Manuel d’utilisation
Mode d’emploi AW 07200003A

Système de surveillance de la glycémie
Manuel d’utilisation
1

Merci d’avoir choisi le système OneTouch Verio Reflect®!
Le système de surveillance de la glycémie OneTouch Verio Reflect® est l’une des toutes dernières innovations de la gamme de produits OneTouch®.
Votre lecteur OneTouch Verio Reflect® est conçu pour se connecter (se synchroniser) avec divers dispositifs sans fil compatibles exécutant des applications logicielles. En connectant votre lecteur à l’appli OneTouch Reveal®, vous pouvez passer en revue vos résultats et les afficher sous forme de graphiques, régler des objectifs de tests quotidiens, consulter les messages du coach de glycémie (Blood Sugar MentorMC) et identifier les tendances. Les résultats du lecteur ainsi que toutes les autres données faisant l’objet d’un suivi sont envoyés aux dispositifs compatibles par l’intermédiaire de la technologie BLUETOOTH® (sans fil) ou d’une connexion par câble USB. Consultez le site www.OneTouch.ca/fr pour obtenir plus de renseignements sur l’appli OneTouch Reveal®.
Chaque lecteur OneTouch® est conçu pour faciliter vos tests de glycémie et la prise en charge de votre diabète.
Ce manuel d’utilisation présente des explications détaillées sur la façon d’utiliser votre nouveau lecteur et les fournitures nécessaires aux tests. Il passe en revue les choses à faire et à ne pas faire au moment de tester votre glycémie. Veuillez conserver votre manuel d’utilisation en lieu sûr; vous pourriez avoir besoin de le consulter ultérieurement.
Nous espérons que les produits et services OneTouch® continueront à faire partie de votre vie.
2

Symboles et icônes du lecteur

Barre de couleur et icônes indicatrices de positionnement des valeurs par rapport à la plage d’objectifs

Basse

Résultat en dessous de la plage d’objectifs

Résultat à la limite inférieure de la plage d’objectifs
Résultat près du milieu de la plage d’objectifs

Résultat au milieu de la plage d’objectifs

Résultat près du milieu de la plage d’objectifs
Résultat à la limite supérieure de la plage d’objectifs
Élevée Résultat au-dessus de la plage d’objectifs

Normale

Résultat dans la plage d’objectifs (texte)

3

Repères de repas et d’événements
Repère Avant le repas Repère Après le repas Repère d’événement Repère d’un événement associé aux glucides Repère d’un événement associé au stress Repère d’un événement associé à une maladie Repère d’un événement associé aux médicaments Repère d’un événement associé à l’exercice
Tendances, suivi des tests et prix Message de tendance Hypo (icône bleue) Message de tendance Hyper (icône rouge) Objectif de tests quotidiens atteint Objectif de tests quotidiens non atteint Prix de niveau Or Prix de niveau Argent Prix de niveau Bronze
4

Icônes du menu Réglages et du menu principal Résumé Journal des résultats Tendance sur 90 jours Menu Réglages Icônes indicatrices de positionnement des valeurs par rapport à la plage d’objectifs sous forme d’émoticône Icônes indicatrices de positionnement des valeurs par rapport à la plage d’objectifs sous forme de texte
Autres icônes du lecteur Fonction BLUETOOTH® activée Synchronisation Résultat obtenu avec la solution de contrôle Pile faible Points de progression de la navigation à l’écran
5

Autres symboles et icônes
Avertissements et mises en garde : Reportez-vous au manuel d’utilisation et aux notices accompagnant votre système pour obtenir des informations relatives à la sécurité. Courant continu
6

Avant de commencer Avant d’utiliser ce produit pour tester votre glycémie, lisez attentivement ce manuel d’utilisation et les notices accompagnant les bandelettes de test OneTouch Verio®, la solution de contrôle OneTouch Verio® et le stylo autopiqueur OneTouch® Delica® Plus.
CONSIGNES DE SÉCURITÉ IMPORTANTES : · Ce lecteur et le stylo autopiqueur ne sont destinés
qu’à un seul patient. Ne les partagez pas avec d’autres personnes, y compris des membres de votre famille! Ne les utilisez pas sur plusieurs patients! · Toutes les pièces de cette trousse sont considérées comme biologiquement dangereuses après avoir été utilisées et exposées au sang. Une trousse usagée pourrait potentiellement transmettre des maladies infectieuses, même après avoir été nettoyée et désinfectée.
Utilisation prévue Le système de surveillance de la glycémie OneTouch Verio Reflect® est prévu pour être utilisé (à des fins de diagnostic in vitro) par des personnes atteintes de diabète sucré pour la mesure quantitative du glucose (sucre) dans des échantillons de sang frais entier d’origine capillaire prélevés au bout du doigt comme aide à la prise en charge du diabète.
7

Le lecteur OneTouch Verio Reflect® analyse les tendances, fait le suivi de ces tendances et fournit des directives (messages éducatifs, de comportement et de motivation) pour vous aider à comprendre et gérer les glycémies, et à détecter les excursions glycémiques au-dessus ou en dessous de la plage d’objectifs souhaitée. Le lecteur est également conçu pour communiquer sans fil avec des applications de prise en charge du diabète compatibles pour l’acquisition, le transfert et l’analyse d’informations et de données de glycémie, dans le but d’aider à l’autoprise en charge du diabète.
Le système de surveillance de la glycémie OneTouch Verio Reflect® ne doit pas être utilisé pour remplacer les conseils d’un professionnel de la santé. Il ne doit pas être utilisé pour le diagnostic ou le dépistage du diabète, ni même à des fins néonatales.
Le système n’est destiné qu’à un seul patient et ne doit pas être partagé.
Principe du test
Le glucose présent dans l’échantillon sanguin se mélange à l’enzyme FAD-GDH (consultez la page 114) de la bandelette de test, ce qui produit un faible courant électrique. L’intensité de ce courant calcule votre glycémie. Il affiche ensuite le résultat de glycémie et le stocke dans la mémoire du lecteur.
Utilisez seulement la solution de contrôle et les bandelettes de test OneTouch Verio® avec le lecteur OneTouch Verio Reflect®. L’utilisation de bandelettes de test OneTouch Verio® avec des lecteurs pour lesquels elles ne sont pas destinées pourrait entraîner des résultats erronés.
8

Technologie sans fil BLUETOOTH® La technologie sans fil BLUETOOTH® est utilisée par certains téléphones intelligents et beaucoup d’autres dispositifs. Votre lecteur OneTouch Verio Reflect® utilise la technologie sans fil BLUETOOTH® pour pouvoir être jumelé avec d’autres dispositifs sans fil compatibles et leur envoyer vos résultats de glycémie. Le lecteur OneTouch Verio Reflect® est conçu pour fonctionner avec l’appli mobile OneTouch Reveal® et d’autres applications de prise en charge du diabète. Consultez le site www.OneTouch.ca/fr pour obtenir une liste des dispositifs sans fil compatibles avec votre lecteur OneTouch Verio Reflect® et savoir où et comment télécharger l’application logicielle.
9

Lors de l’utilisation du système OneTouch Verio Reflect®, nous vous suggérons de jumeler votre lecteur OneTouch Verio Reflect® avec un dispositif sans fil compatible et de procéder à un suivi de vos résultats. Consultez la page 83 pour obtenir les instructions de jumelage. Cet appareil numérique de Classe B respecte la norme canadienne NMB-003. Cet appareil contient des émetteurs / récepteurs exemptés de licence conformes aux RSS (RSS) d’Innovation, Sciences et Développement économique Canada. Le fonctionnement est soumis aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d’interférences (2) Cet appareil doit accepter toutes les interférences, y compris celles susceptibles de provoquer un fonctionnement indésirable de l’appareil. Ces directives contribuent à ce que votre lecteur n’affecte pas le fonctionnement d’autres dispositifs électroniques à proximité. En outre, d’autres dispositifs électroniques ne doivent pas affecter l’utilisation de votre lecteur. Si votre lecteur rencontre des problèmes d’interférences, essayez de l’éloigner de la source d’interférences. Vous pouvez également déplacer le dispositif électronique, ou son antenne, à un autre endroit pour résoudre le problème.
10

MISE EN GARDE : La fonction BLUETOOTH® de votre lecteur envoie les résultats du test à votre dispositif sans fil compatible. Pour éviter que les résultats d’autres personnes ne soient envoyés à votre dispositif sans fil compatible, ne laissez personne d’autre utiliser votre lecteur pour tester sa glycémie. Ce lecteur n’est destiné qu’à un seul patient.
MISE EN GARDE : Dans les endroits où le téléphone cellulaire n’est pas autorisé, comme les hôpitaux, certains cabinets de professionnels de la santé et les avions, vous devez désactiver la fonction BLUETOOTH®. Consultez la page 80 pour obtenir plus de renseignements.
Ne laissez pas votre lecteur sans surveillance dans un lieu public de sorte que d’autres personnes pourraient modifier vos paramètres personnels ou établir une connexion physique.
Le lecteur a fait l’objet d’une conception défensive pour empêcher toute tentative malveillante et a été testé à cet effet.
Marque de commerce BLUETOOTH® Les logos et le mot servant de marque BLUETOOTH® sont des marques déposées de Bluetooth SIG, Inc. et sont utilisés sous licence par LifeScan Scotland Ltd. Les autres marques de commerce et noms commerciaux appartiennent à leurs propriétaires respectifs.
11

Table des matières
1 Familiarisation avec votre système ……………………. 13 2 Réglage de votre système…………………………………. 21 3 Réalisation d’un test…………………………………………. 31 Réalisation d’un test de glycémie……………………………………31 Réalisation d’un test avec la solution de contrôle ……….. 52 4 Marquage des résultats……………………………………..60 5 Compréhension des messages ………………………….. 63 6 Résumé, journal des résultats et tendance
sur 90 jours……………………………………………………….71 7 Synchronisation de votre lecteur……………………….80 8 Ajustement des réglages du lecteur …………………..88 9 Entretien de votre système………………………………..98 10 Piles………………………………………………………………..102 11 Dépannage …………………………………………………….. 105 12 Informations sur le système ……………………………. 112 13 Index ……………………………………………………………… 122
12

1 Familiarisation avec votre système 1
Votre système de surveillance de la glycémie OneTouch Verio Reflect® Votre trousse contient les articles suivants :

Stylo autopiqueur

Lecteur OneTouch Verio Reflect® (deux piles boutons au lithium CR2032 incluses)

Lancettes

13

1 Familiarisation avec votre système
REMARQUE : Si un article de votre trousse est absent ou défectueux, communiquez avec le service à la clientèle. Les coordonnées du service à la clientèle se trouvent à la fin du présent manuel d’utilisation.
REMARQUE : Si un autre type de stylo autopiqueur a été inclus, consultez les instructions distinctes de ce stylo autopiqueur.
Composants disponibles séparément :
Les articles illustrés ci-dessous sont nécessaires, mais peuvent ne pas être inclus dans votre trousse :
Ils sont vendus séparément. Reportez-vous au carton d’emballage de votre lecteur pour obtenir une liste des articles fournis.

Solution de contrôle à concentration moyenne OneTouch Verio®*

Bandelettes de test OneTouch Verio®*

  • La solution de contrôle et les bandelettes de test OneTouch Verio® sont disponibles séparément. Pour en savoir plus sur la disponibilité des bandelettes de test et de la solution de contrôle, communiquez avec le service à la clientèle ou avec votre pharmacien ou votre professionnel de la santé.

14

Familiarisation avec votre système 1 MISE EN GARDE : Gardez le lecteur et les fournitures de test hors de la portée des jeunes enfants. Ils risqueraient de s’étouffer avec les petites pièces comme le couvercle des piles, les piles, les bandelettes de test, les lancettes, les couvercles de protection des lancettes et le capuchon du flacon de solution de contrôle. N’ingérez ou n’avalez aucune pièce.
15

1 Familiarisation avec votre système Apprendre à connaître votre système de surveillance de la glycémie OneTouch Verio Reflect®
Lecteur
16

Familiarisation avec votre système 1
1 Fente d’insertion des bandelettes de test Insérer une bandelette de test ici pour mettre le lecteur en marche
2 Icône de pile Apparaît uniquement lorsque les piles sont faibles
3 mmol/L est l’unité de mesure préréglée; elle ne peut pas être modifiée*
4 Port de données micro-USB Permet de se connecter pour télécharger des données sur un ordinateur
5 Bouton OK · Permet d’allumer et d’éteindre le lecteur (appuyer et maintenir enfoncé) · Permet de confirmer les sélections de menus (appuyer et relâcher)
6 Bouton Retour · Permet de retourner à l’écran précédent (appuyer et relâcher) · Peut être utilisé pour changer un repère de repas ou ajouter un repère d’évènement
7 Boutons fléchés Haut et Bas · Permettent de mettre en surbrillance la sélection souhaitée (appuyer et relâcher) · Permettent d’accroître la vitesse de défilement (appuyer sur l’un des boutons et le maintenir enfoncé)
8 Barre de couleur
9 Icône indicatrice de positionnement des valeurs par rapport à la plage d’objectifs
10 Icônes du suivi des tests
17

1 Familiarisation avec votre système
MISE EN GARDE : * Confirmez que l’unité de mesure mmol/L est affichée. Si votre écran indique l’unité mg/dL plutôt que mmol/L, cessez d’utiliser le lecteur et communiquez avec le service à la clientèle. Familiarisation avec votre bandelette de test OneTouch Verio®
Bandelette de test
11 Canal de dépôt de l’échantillon 12 Broches argentées
À insérer dans la fente d’insertion de la bandelette de test (1)
Aperçu des fonctions Le lecteur OneTouch Verio Reflect® est équipé de fonctionnalités conçues pour vous aider à gérer votre glycémie de diverses manières. Nous espérons que ces fonctions vous seront utiles et que vous les intégrerez à votre routine de prise en charge du diabète.
18

Familiarisation avec votre système 1

Messages du coach de glycémie (Blood Sugar MentorMC)
Les messages du coach de glycémie (Blood Sugar MentorMC) donnent un aperçu sur votre façon de faire et des directives pour la prise en charge du diabète, y compris des messages éducatifs et de motivation fondés sur vos résultats de glycémie actuels et antérieurs ainsi que d’autres données faisant l’objet d’un suivi. Une fois que vous recevez votre résultat de glycémie, le lecteur peut afficher des conseils (directives), des messages de tendances (informations) ou des prix (encouragement).

Exemples de messages du coach de glycémie (Blood Sugar MentorMC)

11.1
mmol/L
Tendance obs.
Glycémie élevée lors des 5 derniers jours. Quelque chose a-t-il changé? OK
Aperçu

3.1
mmol/L
Glycém. à traiter
Glycémie basse, envisagez de boire un jus. Refaites un test dans 15 minutes. OK
Directives

5.8
mmol/L
Bien joué
Vous êtes revenu dans la plage d’obj. après 2 résultats bas de suite. OK
Encouragement

19

1 Familiarisation avec votre système
Indicateur dynamique de positionnement des valeurs par rapport à la plage d’objectifs ColourSure® L’indicateur dynamique de positionnement des valeurs par rapport à la plage d’objectifs ColourSure® vous indique instantanément si votre résultat en cours est dans l’objectif (vert), inférieur à votre objectif (bleu) ou supérieur à votre objectif (rouge). Il vous indique également lorsque votre résultat est proche de la limite inférieure ou supérieure de votre plage d’objectifs. Suivi des tests Le suivi des tests vous permet de définir le nombre de tests de glycémie que vous envisagez de faire chaque jour et suit automatiquement vos progrès vers l’atteinte de cet objectif. Tendance sur 90 jours La tendance sur 90 jours vous permet de définir votre objectif de glycémie moyen sur 90 jours et suit vos progrès vers l’atteinte de cet objectif. Le graphique des moyennes est automatiquement mis à jour toutes les deux semaines et fournit une vue d’ensemble des tendances de votre glycémie au fil du temps.
20

2 Réglage de votre système 2

Réglage de votre lecteur

Mise en marche de votre lecteur Pour allumer votre lecteur, appuyez sur le bouton et maintenez-le enfoncé jusqu’à ce que l’écran de bienvenue s’affiche. Une fois que l’écran de bienvenue s’affiche, relâchez le bouton . Vous pouvez également allumer le lecteur en insérant une bandelette de test.

Chaque fois que vous allumez votre lecteur, un écran de bienvenue apparaît pendant quelques secondes. Si le lecteur ne s’allume pas, vérifiez les piles. Consultez la page 102.
ATTENTION :
Si vous observez des pixels manquants sur l’écran de bienvenue, le lecteur a peut-être un problème. Communiquez avec le service à la clientèle. Les coordonnées du service à la clientèle se trouvent à la fin du présent manuel d’utilisation.

Bienvenue. Commençons.
Exemple

REMARQUE : Si vous allumez le lecteur pour la première fois au moyen du bouton ou d’une bandelette de test, vous devrez compléter la première configuration.

21

2 Réglage de votre système
Utiliser le rétroéclairage pour une meilleure visibilité
Le rétroéclairage est activé automatiquement quand le lecteur est allumé. Après quelques secondes d’inactivité, le rétroéclairage s’atténuera. Le fait d’appuyer sur un bouton quelconque ou d’insérer une bandelette de test réactivera le rétroéclairage.
Première configuration
Avant d’utiliser votre lecteur la première fois, vous serez invité(e) à régler la langue, l’heure, la date, les seuils des plages d’objectifs, l’objectif de tests quotidiens et l’objectif moyen sur 90 jours.
REMARQUE :
· Vous ne pourrez pas procéder à un test de glycémie tant que vous n’aurez pas complété la première configuration.
· Assurez-vous de consulter votre professionnel de la santé au sujet des réglages des seuils, de l’objectif de tests quotidiens et de l’objectif moyen sur 90 jours qui vous conviennent. Lors de la sélection ou de la modification de ces réglages, vous devez prendre en compte d’autres facteurs tels que vos habitudes de vie et votre traitement du diabète. N’apportez jamais de changements importants à votre plan de soins du diabète sans avoir consulté préalablement votre professionnel de la santé.
· Il est important de sélectionner les réglages avec soin pour s’assurer d’enregistrer les bonnes informations avec vos résultats de test.
22

Réglage de votre système 2

Le lecteur est livré préréglé pour vous aider avec la première configuration. Cependant, si vous devez modifier un réglage, appuyez sur ou pour mettre Modifier en surbrillance et appuyez sur . Appuyez ensuite sur ou
pour modifier les valeurs. Après avoir fait votre sélection, mettez Enregistrer en surbrillance et appuyez sur pour confirmer votre sélection et passer à l’écran suivant.
Appuyez sur pour retourner à l’écran précédent.

1. Appuyer sur ou pour mettre la langue de votre choix en surbrillance, puis appuyer sur pour la sélectionner
Le lecteur affichera une invite vous offrant l’option de compléter la première configuration au moyen de l’appli OneTouch Reveal®. Consultez le site www.OneTouch.ca/fr pour obtenir plus de renseignements sur l’appli OneTouch Reveal®. Si vous ne souhaitez pas accéder à cette option, mettez Non en surbrillance et appuyez sur pour continuer la première configuration avec le lecteur uniquement.

Langue
English Français

23

2 Réglage de votre système

Si vous sélectionnez Oui, vous serez invité(e) à jumeler le lecteur avec votre dispositif sans fil compatible. Consultez la page 81. Après le jumelage, l’appli OneTouch Reveal® vous indiquera le processus à suivre pour la première configuration. Les étapes restantes ci-dessous ne seront pas requises.
REMARQUE : Le point de progression vert se déplacera de la gauche vers la droite à mesure que vous naviguez sur les écrans de la première configuration.
2. Confirmer l’heure et appuyer sur pour l’enregistrer
Appuyez sur Modifier pour changer l’heure préréglée.

Réglage
Voulez-vous poursuivre le réglage à l’aide de l’appli mobile OneTouch Reveal?
Oui Non
Point de progression
Réglez l’heure
1:00 pm

Enregistrer Modifier

3. Confirmer la date et appuyer sur pour l’enregistrer Le fait de sélectionner Modifier vous permettra de changer la date préréglée.
24

Réglez la date
Jul 4 2018 Enregistrer
Modifier

Réglage de votre système 2

REMARQUE :
· Le format de l’heure et de la date ne peut pas être modifié.
· Tous les 6 mois, et chaque fois que vous remplacerez les piles, un écran vous demandera de confirmer la date et l’heure définies dans le lecteur.

Veuillez vérifier Jul 4 2018 1:00 pm
Cette heure/date est-elle correcte?
Oui Modifier
Exemple

Le fait de sélectionner Modifier vous permettra de changer l’heure et la date. Une fois qu’elles sont correctes, sélectionnez Terminé.

4. Confirmer les seuils Avant le repas et appuyer sur pour les enregistrer

Avant repas
Réglez les seuils de votre plage d’objectifs
3.9 à 7.2
mmol/L
Enregistrer Modifier

Exemple
Le fait de sélectionner Modifier vous permettra de changer les seuils Avant le repas préréglés.

25

2 Réglage de votre système

Votre lecteur utilise les seuils Avant le repas et Après le repas définis dans votre lecteur pour vous indiquer lorsqu’un résultat de test est dans la plage d’objectifs, au-dessus ou en dessous de vos seuils Hyper/Hypo associés aux repas. Les seuils Hyper/Hypo associés aux repas que vous avez définis durant la première configuration s’appliqueront à tous les résultats de glycémie. Ils sont utilisés dans la fonction Indicateur dynamique de positionnement des valeurs par rapport à la plage d’objectifs ColourSure® pour détecter les tendances et dans le résumé. Consultez la page 44, la page 64 et la page 71 pour obtenir plus de renseignements.

Seuils Avant le repas

seuil Hypo préréglé
seuil Hyper préréglé
le seuil Hypo doit être réglé dans la plage d’objectifs
le seuil Hyper doit être réglé dans la plage d’objectifs

4,0 mmol/L 7,0 mmol/L 3,3 mmol/L et 6,1 mmol/L
5,0 mmol/L et 16,7 mmol/L

5. Confirmer les seuils Après le repas et appuyer sur pour les enregistrer
Le fait de sélectionner Modifier vous permettra de changer les seuils Après le repas préréglés.

Après repas
Réglez les seuils de votre plage d’objectifs
3.9 à 10.0
mmol/L
Enregistrer Modifier

Exemple
26

Réglage de votre système 2

Seuils Après le repas

seuil Hypo préréglé
seuil Hyper préréglé
le seuil Hypo doit être dans la plage d’objectifs
le seuil Hyper doit être dans la plage d’objectifs

5,0 mmol/L 10,0 mmol/L 3,3 mmol/L et 6,1 mmol/L
5,0 mmol/L et 16,7 mmol/L

6. Confirmer le réglage du suivi des tests et appuyer sur pour l’enregistrer
Le fait de sélectionner Modifier vous permettra de changer l’objectif de tests quotidiens préréglé pour le suivi des tests.
Le suivi des tests vous permet de définir le nombre de tests de glycémie que vous envisagez de faire chaque jour et suit automatiquement vos progrès vers l’atteinte de cet objectif.
Le lecteur est préréglé avec un objectif de tests quotidiens de quatre tests par jour. L’objectif de tests quotidiens maximal est de huit. Consultez la page 94 pour obtenir plus de renseignements.

Suivi des tests
Rég. un obj. quot.?
Obj. de tests : 4 Enregistrer Modifier

27

2 Réglage de votre système

7. Confirmer l’objectif moyen sur 90 jours et appuyer sur pour l’enregistrer

Tend. 90 j.
Réglez votre objectif moyen sur 90 jours

Le fait de sélectionner Modifier vous permettra de changer l’objectif moyen sur 90 jours préréglé.

8.6 mmol/L Enregistrer

La tendance sur 90 jours vous permet

Modifier

de définir votre objectif de glycémie

moyen sur 90 jours et suit vos progrès vers l’atteinte de cet

objectif. Le graphique des moyennes est automatiquement

mis à jour toutes les deux semaines et fournit une vue

d’ensemble des tendances de votre glycémie au fil du temps.

Le lecteur est préréglé avec un objectif quotidien moyen sur 90 jours de 8,6 mmol/L. L’objectif moyen minimal sur 90 jours est de 5,5 mmol/L et l’objectif maximal de 14,7 mmol/L. Consultez la page 78 pour obtenir plus de renseignements.

Le message Réglage terminé apparaît à l’écran. Votre lecteur est prêt à être utilisé.

Réglage terminé

28

Réglage de votre système 2
Si le lecteur a été mis en marche en insérant une bandelette de test, l’écran Déposez un échantil. de sang s’affichera. Pour effectuer un test de glycémie, consultez la page 31.
REMARQUE : Après la première configuration, vous pouvez en tout temps ajuster vos réglages. Consultez la page 88 pour obtenir plus de renseignements.
Compréhension du mode de base Le lecteur est fourni avec de nombreuses fonctions permettant de suivre les progrès réalisés dans la prise en charge du diabète. Le mode de base désactivera ces fonctions si vous préférez ne pas utiliser le lecteur de cette façon. Lorsque le mode de base est sélectionné, le suivi des tests, le placement de repères d’événement et de repas, les moyennes Avant le repas et Après le repas, la tendance sur 90 jours, les messages de tendances, les conseils et les prix seront désactivés. En mode de base, les seuils sont généraux et ne sont pas définis selon l’heure du repas. Les icônes indicatrices de positionnement des valeurs par rapport à la plage d’objectifs apparaissent sous forme de texte (par exemple, Normale ) plutôt que sous forme d’émoticône (par exemple, ). Pour obtenir plus de renseignements au sujet de l’activation et de la désactivation du mode de base, consultez la page 93.
29

2 Réglage de votre système Arrêt du lecteur Il y a trois façons d’arrêter le lecteur : · Appuyez sur le bouton et maintenez-le enfoncé
pendant plusieurs secondes jusqu’à l’arrêt du lecteur. · Retirez la bandelette de test. · Votre lecteur s’arrête de lui-même si vous n’y touchez pas
pendant deux minutes.
30

3 Réalisation d’un test 3
Réalisation d’un test de glycémie Préparation d’un test de glycémie
REMARQUE : Un grand nombre de personnes trouvent utile de s’exercer à faire des tests avec la solution de contrôle avant d’effectuer des tests pour la première fois avec du sang. Consultez la page 53. Au moment d’effectuer un test, vous devez avoir sous la main les articles suivants :
Lecteur OneTouch Verio Reflect® Bandelettes de test OneTouch Verio® Stylo autopiqueur Lancettes stériles
REMARQUE :
· Utilisez seulement les bandelettes de test OneTouch Verio®. · Contrairement à certains lecteurs de glycémie,
aucune étape distincte pour coder votre système OneTouch Verio Reflect® n’est requise. · Le test doit être réalisé à l’intérieur de la plage de températures de fonctionnement (6 à 44 °C). · Assurez-vous que votre lecteur et les bandelettes de test sont à peu près à la même température avant d’effectuer votre test. · Gardez les bandelettes de test dans un endroit frais et sec, à une température comprise entre 5 et 30 °C.
31

3 Réalisation d’un test
· N’effectuez pas de test si vous constatez la présence de condensation (accumulation d’eau) sur votre lecteur. Déplacez votre lecteur et vos bandelettes de test dans un endroit frais et sec et attendez que la surface du lecteur sèche avant d’effectuer un test.
· N’ouvrez pas le flacon de bandelettes de test tant que vous n’êtes pas prêt(e) à prélever une bandelette de test et à effectuer un test. Utilisez la bandelette de test immédiatement après l’avoir retirée du flacon.
· Fermez immédiatement et hermétiquement le capuchon du flacon après utilisation pour éviter tout dommage et toute contamination.
· Conservez les bandelettes de test non utilisées uniquement dans leur flacon d’origine.
· Ne remettez pas la bandelette de test usagée dans le flacon après avoir effectué un test.
· Ne réutilisez pas une bandelette de test souillée par du sang, de la solution de contrôle ou tout autre contaminant. Les bandelettes de test sont exclusivement à usage unique.
· Vous pouvez toucher la bandelette de test à n’importe quel endroit de sa surface avec des mains propres et sèches. Ne pliez pas, ne coupez pas et ne modifiez pas la bandelette de test d’une quelconque façon.
32

Réalisation d’un test 3
· Lorsque vous ouvrez un flacon de bandelettes de test pour la première fois, notez la date d’élimination sur l’étiquette. Reportez-vous à la notice des bandelettes de test ou à l’étiquette du flacon pour obtenir des instructions permettant de déterminer la date d’élimination.
· Il n’est pas recommandé de comparer vos résultats de test de glycémie obtenus avec ce lecteur avec vos résultats obtenus avec un autre lecteur. Les résultats peuvent différer d’un lecteur à l’autre et ne constituent pas une mesure pertinente pour savoir si votre lecteur fonctionne convenablement. Pour vérifier la précision de votre lecteur, vous devez comparer régulièrement les résultats du lecteur avec ceux obtenus par un laboratoire. Consultez la page 112 pour obtenir plus de renseignements.
IMPORTANT : Si une autre personne vous aide à effectuer votre test, le lecteur doit toujours être nettoyé avant que cette personne puisse l’utiliser. Consultez la page 98.
ATTENTION :
· Le système de surveillance de la glycémie OneTouch Verio Reflect® ne doit pas être utilisé chez les patients dans les 24 heures suivant la réception d’un test d’absorption du D-xylose, car il peut entraîner des résultats inexacts élevés.
33

3 Réalisation d’un test
· N’utilisez pas la gamme de lecteurs OneTouch Verio® dans le cas d’une présence avérée (ou une suspicion de présence) de PAM (Pralidoxime) dans l’échantillon sanguin entier du patient.
· N’utilisez pas vos bandelettes de test si votre flacon est endommagé ou ouvert. Cela pourrait entraîner des messages d’erreur ou des résultats erronés. Communiquez immédiatement avec le service à la clientèle si le flacon de bandelettes de test est endommagé. Les coordonnées du service à la clientèle se trouvent à la fin du présent manuel d’utilisation.
· Si vous ne pouvez pas effectuer un test en raison d’un problème avec vos fournitures de test, communiquez avec votre professionnel de la santé. Le fait de ne pas effectuer un test pourrait retarder des décisions de traitement et entraîner des conditions médicales graves.
· Le flacon de bandelettes de test contient des agents dessiccatifs qui sont nocifs s’ils sont inhalés ou avalés et peuvent causer une irritation de la peau ou des yeux.
· N’utilisez pas les bandelettes de test après la date de péremption (imprimée sur le flacon) ou la date d’élimination, selon celle de ces dates qui survient la première, au risque d’obtenir des résultats erronés.
34

Réalisation d’un test 3
Familiarisation avec votre stylo autopiqueur OneTouch® Delica® Plus
1 Bouton déclencheur 2 Commande coulissante 3 Indicateur de la profondeur 4 Roulette de réglage de la profondeur 5 Embout du stylo autopiqueur 6 Couvercle de protection
REMARQUE : · Le stylo autopiqueur OneTouch® Delica® Plus utilise les
lancettes OneTouch® Delica® ou OneTouch® Delica® Plus. · Si un autre type de stylo autopiqueur a été inclus,
consultez les instructions distinctes de ce stylo autopiqueur. · Le système de surveillance de la glycémie OneTouch Verio Reflect® n’a pas été évalué pour les tests à partir d’un autre site (AST). Utilisez seulement des échantillons prélevés au bout du doigt quand vous effectuez un test avec le système.
35

3 Réalisation d’un test
Précautions relatives au stylo autopiqueur
ATTENTION :
Pour réduire le risque d’infection et de maladies propagées par le sang :
· Veillez à laver le site de prélèvement avec de l’eau chaude et du savon, à le rincer et à le sécher avant d’effectuer un prélèvement.
· Le stylo autopiqueur n’est destiné qu’à un seul utilisateur. Ne partagez jamais une lancette ou un stylo autopiqueur avec une autre personne.
· Utilisez toujours une lancette neuve et stérile chaque fois que vous effectuez un test.
· Gardez toujours votre lecteur et votre stylo autopiqueur propres (consultez la page 98).
· Le lecteur et le stylo autopiqueur ne sont destinés qu’à un seul patient. Ne les partagez pas avec d’autres personnes, y compris des membres de votre famille! Ne les utilisez pas sur plusieurs patients!
· Toutes les pièces de cette trousse sont considérées comme biologiquement dangereuses après avoir été utilisées et exposées au sang. Une trousse usagée pourrait transmettre des maladies infectieuses, même après avoir été nettoyée et désinfectée.
· N’utilisez pas les lancettes après la date de péremption imprimée sur l’emballage des lancettes.
36

Réalisation d’un test 3
Préparation de votre stylo autopiqueur 1. Retirer l’embout du stylo autopiqueur Tournez l’embout, puis retirez-le du stylo dans un mouvement rectiligne.
2. Insertion d’une lancette stérile dans le stylo autopiqueur Alignez la lancette tel qu’indiqué sur l’illustration, de façon à ce qu’elle rentre parfaitement dans le support de lancette. Enfoncez la lancette dans le stylo jusqu’à ce qu’elle s’enclenche complètement dans le support. Tournez le couvercle de protection en effectuant un tour complet jusqu’à ce qu’il soit possible de le détacher de la lancette. Gardez le couvercle de protection pour le retrait et l’élimination de la lancette. Consultez la page 49.
37

3 Réalisation d’un test
3. Remettre en place l’embout du stylo autopiqueur Remettez l’embout sur le stylo; tournez l’embout ou poussez-le directement pour le fixer. Assurez-vous que l’embout est aligné comme indiqué sur l’image.
4. Ajustement du réglage de la profondeur Le stylo dispose de 13 réglages pour la profondeur de ponction. Chaque point affiché entre les chiffres de 1 à 7 sur la roulette de réglage de la profondeur indique un réglage de profondeur supplémentaire offert. Vous pouvez facilement régler la profondeur en tournant la roulette de réglage de la profondeur. Les plus petits chiffres sont destinés à des ponctions moins profondes et les chiffres supérieurs à une ponction plus profonde. REMARQUE : Essayez d’abord des réglages moins profonds et augmentez la profondeur jusqu’à atteindre une profondeur suffisante pour pouvoir prélever le bon volume d’échantillon sanguin.
38

Réalisation d’un test 3
5. Armer le stylo autopiqueur Tirez la commande coulissante vers l’arrière jusqu’à ce que vous entendiez un clic. En l’absence de clic, il se peut que l’armement se soit produit au moment où vous avez inséré la lancette.
Préparation du lecteur 1. Insérer une bandelette de test pour allumer le lecteur Insérez une bandelette de test dans la fente d’insertion prévue à cet effet, le côté doré de la bandelette et les deux broches argentées face à vous.
Broches argentées
Fente d’insertion des bandelettes de test REMARQUE : Il n’est pas nécessaire de coder le lecteur lors d’une étape distincte.
39

3 Réalisation d’un test
L’écran Déposez un échantil. de sang s’affiche. Vous pouvez à présent déposer votre échantillon sanguin sur la bandelette de test.
Déposez un échantil. de sang
Prélèvement de sang sur le bout du doigt Choisissez un site de ponction différent à chaque test. Des ponctions répétées au même endroit risquent d’occasionner une douleur et la formation de callosités. Avant d’effectuer un test, lavez bien vos mains et le site de prélèvement à l’eau chaude et au savon. Rincez-les, puis séchez-les complètement. La présence de contaminants sur la peau peut avoir un effet sur les résultats. 1. Ponction sur votre doigt Maintenez fermement le stylo autopiqueur sur le côté de votre doigt. Appuyez sur le bouton déclencheur. Retirez le stylo autopiqueur de votre doigt.
40

Réalisation d’un test 3
2. Obtention d’une goutte de sang ronde Pressez ou massez doucement le bout de votre doigt jusqu’à l’apparition d’une goutte de sang ronde. REMARQUE : Si le sang s’étale ou s’écoule, n’utilisez pas cet échantillon. Séchez la zone et pressez-la doucement pour obtenir une autre goutte de sang, ou bien piquez un nouveau site. Dépôt du sang et lecture des résultats Dépôt de l’échantillon 1. Déposer

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals