FIRST ALERT SMCO200V 2 IN 1 Smoke and Carbon Monoxide Alarm Instructions

August 10, 2024
First Alert

FIRST ALERT SMCO200V 2 IN 1 Smoke and Carbon Monoxide Alarm

Product Information

Specifications

  • Model: SMCO200V Cat. 1046795
  • Type: 2-IN-1 Smoke & Carbon Monoxide Alarm
  • Alarm Dimensions: 5.68 Dia. x 1.3 H
  • Weight: 0.49 lb
  • Battery: 3V (2 AA)
  • Humidity Range: 10% to 95% relative humidity (RH)
  • Audio Alarm: 85dB at 10 feet
  • Listing: Certified to UL217 & UL2034

Product Usage Instructions

Installation

  • Installation of this smoke alarm must conform to NFPA 72 and local building codes. Follow the placement instructions in the user’s manual.

Testing and Maintenance

  • To test the alarm, press and hold the test/silence button to simulate a smoke condition.
  • Ensure the alarm sounds and the indicator lights flash accordingly. The alarm will automatically reset when the smoke clears.

Battery Replacement

  • When the low battery signal is indicated, replace the batteries promptly with two AA 3V batteries.

End-of-Life Signal

  • The unit provides a 10-year end-of-life signal to indicate when it needs to be replaced.
  • Once this signal is activated, replace the entire unit.

FAQ

  • Q: How often should I test the smoke and carbon monoxide alarm?
  • A: It is recommended to test the alarm monthly to ensure proper functionality.
  • Q: What should I do if the alarm indicates a malfunction?
  • A: If the alarm indicates a malfunction, refer to the user’s manual for troubleshooting steps or contact customer support for assistance.

Slim Profile Design

  • Half the depth of a standard alarm.

ARCHITECTURAL AND ENGINEERING SPECS

The smoke alarm shall be a First Alert Model SMCO200V and shall provide at a minimum the following features and functions:

  1. A Photoelectric smoke sensing chamber and an electrochemical CO sensor.
  2. The unit shall have a “10-Year End of Life” signal. This signal should be capable of temporarily being silenced for up to 2 days. After about 2 days, the signal will resume. After about 2 weeks the signal cannot be silenced.
  3. Capable of self-restoring.
  4. Powered by replaceable 2 AA alkaline batteries and a solid-state speaker horn rated at 85dB at 10 ft.
  5. A visual LED power-on indicator to confirm the unit is receiving power or is in alarm.
  6. A full-function test button should check all alarm functions by simulating a smoke and CO condition, causing the unit to alarm.
  7. Two Silence features – Low Battery Silence: Silence low battery chirp for up to 8 hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
  8. Tamper-resistant locking pin that locks alarm to mounting bracket to prevent removal of batteries.
  9. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and relative humidity between 10% and 95%.
  10. The unit shall contain mounting hardware and shall be listed for wall or ceiling mounting.
  11. The unit meets the applicable requirements of UL217, UL2034, CSFM, NFPA 72, NFPA 101, and ICC.

INSTALLATION OF ALARM

  • Installation of this smoke alarm must conform to NFPA 72.
  • Always check your local building codes.
  • Follow all instructions for placement as outlined in the user’s manual in sections titled “Recommended Locations for Smoke Alarms” and “Locations to Avoid for Smoke Alarms.”

TECHNICAL SPECS

  • Alarm Dimensions: 5.68” Dia. x 1.3” H
  • Weight: 0.49 lb
  • Battery: 3V (2 AA)
  • Temperature Range: 40°F (4.4°C) to 100°F (37.8°C)
  • Humidity Range: 10% to 95% relative humidity (RH)
  • Audio Alarm: 85dB at 10 feet
  • Test/Silence: Electronically simulate smoke condition, causing the unit to alarm. Press and hold the test/silence button.
  • Alarm Reset: Automatic when smoke clears
  • Smoke Sensor: Photoelectric
  • Indicator Lights/Sounds:
    • DC Power: Flashes Green every minute
    • Smoke Alarm: 3 Beeps, Flashes Red
    • CO Alarm: 4 Beeps, Flashes Red
    • Low Battery: 1 “Chirp” every Minute – Replace Battery
    • Malfunction: 3 “Chirps” every Minute – Replace Alarm
    • End of Life: 5 “Chirps” every Minute – Replace Alarm
  • Listing: Certified to UL217 & UL2034

© 2024 Resideo Technologies, Inc. All rights reserved. These products are manufactured by Resideo Technologies, Inc. and its affiliates. firstalert.com. www.resideo.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

First Alert User Manuals

Related Manuals