Product Specifications

  • Model: N G E 3 0

  • Wattage: 30W

  • Type: AC-DC Reliable Wall-mounted Interchangeable Type Green
    Adaptor

  • DC Voltage Options:

    • 5V – 4A
    • 9V – 3.33A
    • 12V – 2.5A
    • 15V – 2A
    • 18V – 1.66A
    • 24V – 1.25A
    • 48V – 0.63A
  • Ripple & Noise: 100mVp-p to 240mVp-p depending on voltage

Product Usage Instructions

Installation

  • Choose a suitable wall mounting location near the power outlet.
  • Plug the adaptor into the power outlet and ensure a stable connection.

Powering the Device

  • Connect the appropriate DC plug to your device.
  • Plug the DC plug into the adaptor’s output port.

Power Management

  • Check the LED indicator on the adaptor to ensure power supply.
  • Avoid overloading the adaptor beyond the specified limits.

Frequently Asked Questions

Q: What is the maximum temperature range for operation?

A: The product is rated to operate between -30°C to +70°C, refer to the derating curve for more details.

Q: How can I check if the adaptor is working correctly?

A: Verify the LED indicator status and ensure a stable connection with your device.

User’s Manual

Features

  • MEAN WELL Patent Application Number: 202330347779.4
  • Interchangeable AC plugs
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)
  • Universal AC input / Full range
  • Ultra slim(30mm)
  • No load power consumption< 0.075W
  • Energy efficiency Level VI
  • Class Il power (no earth pin)
  • Protections: Short circuit / Overload / Over voltage
  • Pass LPS
  • Extremely low leakage current <100uA
  • -30°C ~+70°C wide range working temperature
  • Various DC plug quick adapter accessory available

Applications

• Consumer electronic devices
• Telecommunication devices
• Office facilities
• Industrial equipments
• Medical devices
• Household devices

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

NGE30 is a highly reliable, 30W wall-mounted style single-output green adaptor series, which is compact and convenient for carry. This product is equipped with 5 types of interchangeable AC plug (European, USA,U.K. Australian and China type) that makes it very suitable for travel use. NGE30 is a Class II power unit (no FG), accepting the input range from 80VAC to 264VAC that it can satisfy the demands for various types of electrical devices. With the working efficiency up to 91.5% and the extremely low no-load power consumption below 0.075W, NGE30 is compliant with the latest USA energy regulation EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS,EU ErP and CoC version5. The supreme feature allows the adaptor to save the energy when it is under either the operating mode or the standby mode. The entire series is approved for ITE, medical, household and industrial appliance safety regulations; moreover, it adopts the 94V-0 flame retardant plastic case that it can effectively prevent users from electric hazard.

Model Encoding

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-1

SPECIFICATION

ORDER NO.| NGE30  05-P1J| NGE30  09-P1J| NGE30  12-P1J| NGE30  15-P1J| NGE30  18-P1J| NGE30  24-P1J| NGE30  48-P1J
---|---|---|---|---|---|---|---
= I, U, E




OUTPUT

| DC VOLTAGE Note.2| 5V| 9V| 12V| 15V| 18V| 24V| 48V
RATED CURRENT| 4A| 3.33A| 2.5A| 2A| 1.66A| 1.25A| 0.63A
CURRENT RANGE| 0 ~ 4A| 0 ~ 3.33A| 0 ~ 2.5A| 0 ~ 2A| 0 ~ 1.66A| 0 ~ 1.25A| 0 ~ 0.63A
RATED POWER| 20W| 30W| 30W| 30W| 30W| 30W| 30W
RIPPLE & NOISE (max.) **Note.3| 100mVp-p| 100mVp-p| 120mVp-p| 150mVp-p| 180mVp-p| 240mVp-p| 240mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION Note.6| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±2.0%
SETUP, RISE, HOLD UP TIME**| 1500ms, 30ms, 30ms / 230VAC 3000ms, 30ms, 10ms / 115VAC at full load



INPUT

| VOLTAGE RANGE Note.7| 80 ~ 264VAC           113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 82.5%| 87.5%| 88.5%| 87%| 88%| 88.5%| 91.5%
AC CURRENT| 1A / 115VAC       0.6A / 230VAC
INRUSH CURRENT (max.)| COLD START 35A / 115VAC  70A / 230VAC
LEAKAGE CURRENT (max.)| Touch current < 100uA (rms) @264VAC



PROTECTION

| ****

OVERLOAD

| 110% ~ 150% rated output power
Protection type : 5~24V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

OVER VOLTAGE| 110% ~ 140% rated output voltage
Protection type : Clamp by zener diode



ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes












SAFETY & EMC

(Note. 8)

| ****

SAFETY STANDARDS

| CB           IEC62368-1,  IEC60601-1/-1-11,  IEC61558-1/-2-16,  IEC60335-1;

UL            UL62368-1, CSA C22.2 NO. 62368-1, ANSI/AAMI ES60601-1/-1-11(3.2 Version), CAN/CSA-C22.2 NO.60601-1/-1-11; DEKRA BS EN/EN62368-1, BS EN/EN60601-1/-1-11, BS EN/EN61558-1/-2-16, BS EN/EN60335-1;

PSE        J62368-1; BSMI  CNS15598-1;

RCM   AS/NZS 61558-1/-2-16; EAC TPTC004;

CCC       GB4943.1 approved.

(Please refer to next page for more details)

WITHSTAND VOLTAGE| I/P-O/P:4000VAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH



EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021| Class B
Radiated emission| BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021| Class B
Harmonic current| BS EN/EN61000-3-2| Class A





EMC IMMUNITY

| Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 15KV air; Level 2, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 2, 3V/m
EFT bursts| BS EN/EN61000-4-4| Level 2, 1KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/L-N
Conducted susceptibility| BS EN/EN61000-4-6| Level 2, 3V
Magnetic field immunity| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage dips , interruption| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 1078.6 Khrs min.       MIL-HDBK-217F (25℃)               7587.5 Khrs min.       Telcordia TR/SR-332(Bellcore) (25℃)
DIMENSION| 623065mm (LWH)
PACKING| MAIN BODY| 148g; 60pcs/ 10.5Kg / 0.91CUFT for NGE30Ixx /Uxx-P1J              162g; 45pcs/ 9.2Kg / 1.06CUFT for NGE30Exx-P1J
AC PLUGS| Refer to Page 3
DC OUTPUT CONNECTOR| PLUG| See page 6~7 ; Other type available by customer requested
CABLE| See page 6~7 ; Other type available by customer requested




NOTE

|

  1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient.
  2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
  3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1 « F & 47 * F capacitor.
  4. Tolerance: includes set up tolerance, line regulation, load regulation.
  5. Line regulation is measured from low line to high line at rated load.
  6. Load regulation is measured from 0% to 100% rated load
  7. Derating may be needed under low input voltage. Please check the derating curve for more details.
  8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

*Product liahility Disclaimer • For detailed intormation nieace refer in hiins /мм meanwell com/service Disclaimer asny

Interchangeable AC Plug Specifically for NGE12/18/30/45/65/90 (I-Type)

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-3

AC Plugs Accessory

(Sold Seperately)

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-4

Interchangeable AC Plug Installation Steps

(Convertible with I Type only)

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-5

Note:

  1. NGE301 main body unit and AC inlet plug should be ordered separately.
  2. NGE30I needs to be used along with one of the AC inlet plug (EU,US,UK,AU,CN).

Derating Curve

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-6

Static Characteristics

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-7

Mechanical Specification

Cable connection
NGE30|xx-P1J:

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-8

NGE30Exx-P1J:

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-9

NGE30Uxx-P1J:

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-10

DC Output Plug

Standard plug: P1J

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-11

DC plug changeable through:

  1. Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
  2. Quick adapter accessory (sold separately without MOQ)
    Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf

Example quick adapter accessory

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-12

Optional DC plug: (Available in customized cable or quick adapter)

MEAN-WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-13 MEAN-
WELL-NGE30-30W-AC-DC-Reliable-Wall-Mounted-Interchangeable-Type-Green-
FIG-14

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals