PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter Instruction Manual

May 15, 2024
PRO USER ELECTRONICS

PRO USER - logo

PSI-SERIES
PURE SINE WAVE INVERTER
WWW.PRO-USER.COM
OPERATING MANUAL

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter -
cover

PURE SINE WAVE INVERTER

PSI Series Pure Sine Wave Inverter

Read this manual before using this product.
Failure to do so can result in serious injury.

INTRODUCTION

The pure sine wave inverters are a member of the family of advanced mobile power inverters manufactured by Pro-User Electronics. Your Pro-User Electronics pure sine wave inverter enables you to generate a pure sine wave 230V AC 50Hz voltage from a 12V DC battery wherever your travels take you. As a bonus we built-in 1 USB-Port for powering or charging e.g. your sat nav, cell phone, tablet or any other USB device. Because of the high quality pure sine wave voltage and the excellent overload capabilities, even sensitive electronics will work flawlessly.
The wired remote control enables you to monitor and control your inverter in a convenient way.
We have taken numerous measures in quality control to ensure that your product arrives in top condition and will perform to your satisfaction.
Please carefully read and follow the safety and operating instructions. Not following these instructions may result in a serious accident, including damaged property, serious or even fatal injuries. If the device is passed on to another person, this manual must also be handed over with it.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: Please read this instruction manual carefully before installing and starting up the device. Do not operate the inverter unless you have fully read and understood all the provided information. If you are not confident working with 12V DC voltage or are unsure of what you are doing, consider to seek for help by a professional installation service or your vehicle´s manufacturer. Failure to observe these instructions may cause an electrical shock, fatal or serious injury, material damage or impair the function of the inverter.
Pro-User Electronics accepts no liability for direct or indirect damage caused by faulty assembly or connection, a usage of damaged or altered products, a usage for purposes other than described and especially caused by failure to follow these instructions.

General:

  • Electrical devices are not toys. Keep the product away from children.
  • Only use the product as intended and for purposes described in the manual.
  • After opening the package, examine all parts for visible damage. If you have found any damage, please contact the company you purchased this unit from.
  • Always disconnect the power supply (including the connection to the battery and an optional solar panel) when working on the device.
  • Use only approved accessories (especially all cables) or parts fully consistent with the requirements. The installer is responsible for ensuring that the correct cable and fuse sizes are used.
  • The surface temperature can reach up to 65°C. Power-off and stop using the device immediately, if the unit is smoking or is showing any abnormal behaviour.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or have been instructed on how to use the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Installing the device, maintenance and repair work may only be carried out by qualified person who are familiar with the risks involved, the relevant regulations and with the guidelines and safety precautions to be applied.
  • Do not disassemble the inverter, the internal circuit contains hazardous voltages. Attempting to service the unit yourself may result in electric shock or fire and will void the unit warranty.
  • Always keep metal objects or other materials that can short circuit the terminals of the battery or the inverter securely away. A resulting spark or short-circuit may not only damage the device, but also cause an explosion and potentially produce a current high enough to weld a ring or the like to metal. Remove personal metal items such as rings, bracelets, necklaces and watches when working on the device or the battery.
  • Operate the inverter only, if all cables and the housing are undamaged and all connections are tight and clean. Loose or dirty connections could result in overheating, electrical sparks and fire.
  • Do not connect AC output terminals of the inverter to an incoming AC source (or the grid). · Do not connect DC input terminals of the inverter to an incoming AC source. · Never use the inverter on vehicles where the positive terminal of the battery is connected to the chassis.
  • Never connect cables in reverse polarity or short-circuit connected cables. This may blow internal fuses and may damage the inverter permanently.
  • A fuse should be provided at a distance of max. 30 cm from the battery´s positive terminal. Failure to do so, may cause damage to the cabling or battery if a fault (e.g. over-current or short circuit) occurs. Only use high quality copper cable and keep the cable length short.
  • Do not operate appliances that may feed AC main power back into the inverter. This might damage the inverter.
  • Ensure the device is standing firmly. The device must be set up and fastened in such a way that it cannot tip over or fall down.
  • Never connect devices that have a higher power requirement than the peak output power of the inverter. Note that some devices may require more starting current than the type plate of the device indicates.

Working with Batteries

  • Batteries can store large amounts of energy and improper handling can be dangerous. Never connect to a battery with an unsuited voltage or other unsuitable or damaged batteries.
  • Keep children away from batteries and acid.
  • Avoid getting electrolyte on your skin or clothes. It is acidic and can cause burns. If battery acid contacts skin or clothing, wash immediately with water. Baking soda neutralizes lead acid battery electrolyte. If electrolyte gets into your eyes, immediately flood your eyes with running cold water for at least 20 minutes and get medical attention immediately. Eye protection is therefore recommended.
  • Always keep metal objects or other materials that can short circuit the terminals of the battery or the inverter securely away.
  • Power-off the device before making or breaking the connections to the battery.
  • Observe technical instructions of the seller or the manufacturer of your battery.
  • Check if all connections are tight and clean. Loose or dirty connections could result in overheating, electrical sparks and fire. Use terminal grease where required.
  • Never smoke or allow a spark or flame in vicinity of the battery.
  • Never try to charge a damaged or frozen battery.
  • Do not place the device directly on top of the battery or vice versa or on a surface constructed from combustible material.
  • Read your car´s owner’s manual. Some vehicle manufacturers may have special requirements before charging or discharging the vehicle´s battery (e.g. fuses that have to be removed or certain security demands).

Environment

  • Only use the product in environments from 0°C ~ 45°C.
  • Do not operate the product in damp, wet or dusty environments: Never expose the inverter to rain or snow. Doing so may result in damage to the inverter or other equipment installed in the system or result in electric shock or fire. Do not operate the unit in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Do not put batteries, or anything that should be protected from sparks around the inverter. Doing so may result in fire or explosion.
  • To avoid heat accumulation, do not cover the device. To prevent overheating , ensure that air inlets and ventilation is not obstructed. Do not expose the device to a heat source (such as direct sunlight or heating). Avoid additional heating of the device in this way.

Electrical Cables

  • If cables have to be fed through metal holes or other walls with sharp edges, use ducts or cable bushings to prevent damage.
  • Do not lay cables which are loose or bent next to electrically conductive material (metal).
  • Do not pull on the cables.
  • Avoid to lay 230 V AC mains cable and 12 V DC cables in the same duct.
  • Prevent all cables from being stepped on, tripped over, or being damaged by e.g. sharp edges or hot surfaces.

GENERAL INSTRUCTIONS

Intended use
The Pro-User Electronics pure sine wave inverter converts a 12V direct current voltage (e.g. a battery or another 12V source that can deliver the required current) into 200-240V 50Hz AC pure sine wave voltage. The built-in USB-port is intended to power or charge 5V USB devices (the maximum current delivery has to be kept in mind). The wired remote control enables the user to monitor and control the inverter in a convenient way.

Packaging materials
To avoid danger of suffocation, do not let children play with foils or other packaging materials. Remove all protective coverings before putting the device in operation.

Storage
When not in use, store the inverter in a dry environment. Store the device in a safe place out of the reach of children. Protect the unit from direct sunlight, heat and moisture.

PACKAGE CONTENTS

  • 1x Pro-User Electronics pure sine wave inverter
  • 1x Remote control (600/1000/1500/2000/3000W)
  • 1x Remote control wiring (600/1000/1500/2000/3000W)
  • 1x Remote control surface mounting frame (600/1000/1500/2000/3000W)
  • 1x Battery wiring set
  • 1x 230V connection cable (1000/1500/2000W)
  • 1x Operating manual

TECHNICAL DESCRIPTION

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - TECHNICAL
DESCRIPTION 1

A) Incoming 230V AC connection (1000W / 1500W / 2000W)
B) Output 230V AC socket
C) ECO mode indication led (1000W / 1500W / 2000W / 3000W)
D) Power switch
E) Remote control wiring connection
F) UPS indication led (1000W / 1500W / 2000W / 3000W)
G) Inverter function indication led
H) Fault indication led
I) AC incoming indication led
J) USB output
K) BY-Pass indication led

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - TECHNICAL
DESCRIPTION 2

A) Positive battery terminal ( red / + )
B) Negative battery terminal ( black / – )
C) Cooling vents

TECHNICAL DESCRIPTION 3000W & HYBRID PSI-SERIES

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - TECHNICAL
DESCRIPTION 3

A) Solar panel input (MC4 Hybrid only)
B) Output 230V AC connections
C) Input 230V AC connection
D) Battery setup dipswitches (Hybrid only)
E) ECO mode indication led
F) Power switch
G) Remote control wiring connection
H) UPS indication led
I) Solar charge function indication led (Hybrid only)
J) Inverter function indication led
K) 230V AC charge function indication led (Hybrid only)
L) Fault indication led
M) AC incoming indication led
N) USB output
O) BY-Pass indication led

REMOTE CONTROL DISPLAY INVERTER MODE

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - REMOTE CONTROL
1

A) Battery Indication
B) Battery voltage
C) AC output running
D) Power consumption
E) AC output voltage
F) Inverter operating

REMOTE CONTROL DISPLAY TRANSFERSWITCH MODE (1000W / 1500W /2000W /3000W)

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - REMOTE CONTROL
2

A) Battery Indication
B) Battery voltage
C) AC output running
D) Power consumption
E) AC output voltage
F) Mains connected (transferswitch/By-pass)

REMOTE CONTROL DISPLAY MPPT SOLAR MODE (HYBRID ONLY)

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - REMOTE CONTROL
3

A) Battery Indication
B) Battery voltage
C) Solar panel connected
D) AC output running
E) Power consumption
F) AC output voltage
G) Inverter operating

DIPSWITCH SETTINGS (HYBRID ONLY)

The battery charger function is set using the dip switches on the side of the inverter. The diagram below shows how to set them. When in doubt about which setting you need, please contact your battery supplier.

Setting| Dip switch| Bulk /Absorption| Float| Battery Type
---|---|---|---|---
L| | SWO| 14.6V| LiFePO4
S| | SW1| 14.8V| 13.8V| Flooded
| SW2| 15.0V| 13.8V| Calcium
| SW3| 14.6V| 13.6V| AGM
| SW4| 14.4V| 13.4V| SLA
| SW5| 14.2V| 13.2V| GEL
Power Supply Mode, Constant Voltage Setting
| | SW6| 13.8V
| | SW7| 12.0V

ECO/UPS FUNCTION (1000/1500/2000/3000W)

The inverter is equipped with ECO (energy saving) and UPS setting. In ECO mode, consumption from the battery is preferred. This way, no external incoming voltage is applied as long as there is suOcient capacity from the battery. If you choose the UPS mode (default setting) then external incoming 230V AC voltage is preferred (bypass). In UPS mode, the battery is selected when no external incoming voltage is available.
To switch from UPS to ECO or vice versa, press and hold the power button for 2 2 2 2 seconds.

INSTALLATION & OPERATION

WARNING: Please read this instruction manual carefully before installing and starting up the device. Do not operate the inverter unless you have fully read and understood all the provided information. If you are not confident working with 12V DC voltage or are unsure of what you are doing, consider to seek for help by a professional installation service or your vehicle´s manufacturer. Failure to observe these instructions may cause an electrical shock, fatal or serious injury, material damage or impair the function of the inverter.
WARNING: Before installing the inverter, please ensure the main switch is set to position “OFF”. Make sure the battery poles are clean when connecting the terminals. Tighten the nuts and bolts to a torque of 12-13 Nm. Loose or dirty connections may cause overheating.
Risk of electrical shock: Operation of the inverter without a proper ground connection may result in an electrical safety hazard. Ensure proper ground connection is made during installation. Do not reverse the polarity. Reversing the polarity of the connections may cause a spark and melt internal fuses.
Observe the relevant regulations and directives of your country! In some country there might be legal regulations that require RCD protection of AC output connections of installations (Residual-current device, also known as RCCB/GFCI). RCDs may be fitted by a licenced electrician in installations.

Fastening the inverter
When selecting the installation location, observe the following instructions:

  • The inverter can be mounted horizontally or vertically.
  • The installation surface must be level and sufficiently sturdy.
  • The inverter must be installed in a place that is protected from dirt, dust and moisture.
  • The inverter may not be installed in the presence of flammable materials.
  • The place of installation must be well-ventilated. A ventilation system must be present for installations in small, closed spaces.
  • The minimum clearance around the inverter should be at least 25 cm.
  • Do not block or cover the ventilation holes. Be sure to keep a distance (at least 1 inch) from surrounding objects.

Wiring & Cables
A fuse should be provided at a distance of max. 30 cm from the battery´s positive terminal. Failure to do so, may cause damage to the cabling or battery if a fault (e.g. over-current or short circuit) occurs. Reverse polarity connection may blow the internal fuse and may damage the inverter permantly.

WIRING SCHEME

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - WIRING SCHEME
1

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - WIRING SCHEME
2

WIRING SCHEME 3000W & HYBRID PSI-SERIES

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - WIRING SCHEME
3

PRO USER ELECTRONICS PSI Series Pure Sine Wave Inverter - WIRING SCHEME
4

Setting-up the inverter
To set up the inverter, use the appropriate cables to:

  • connect the positive pole (usually marked with + or coloured in red) of the battery and the positive pole (coloured in red) of the inverter.
  • connect the negative pole (usually marked with – or coloured in black) of the battery and the negative pole (coloured in black) of the inverter.
  • Automatic Transfer Switch function (by-pass 1000/1500/2000/3000W only).
    Connect the 230V AC incoming connection to the input connection using the supplied cable (not included with 3000W/Hybrid). The by-pass function will automatically take effect when a 230V AC external source is connected (UPS mode). When the external source fails, the inverter function switches on automatically.

Ensure to clamp all cables securely.
The Inverter is now ready to use: Push the main switch to power on the device. Please notice the device functions described in chapter “TECHNICAL DESCRIPTION”
NOTE: You can operate the inverter with your vehicle´s engine running or switched off. However, it is recommended to switch off the inverter while starting the engine.

USB port
Connect the USB external appliance to the USB port and switch it on. The USB port on the power inverter provides a power supply of 5V DC for external USB devices.

Remote Port
Connect the remote unit to the remote connection port.

Solar panel connection (MC4 connectors). Hybrid PSI series only.
Install your solar panel on the MC4 connectors. The system itself recognizes the connection and the charging function of the MPPT controller takes effect.

Battery dipswitches settings. Hybrid PSI series only.
To optimally charge your batteries, the Hybrid inverter is equipped with dip switches. See chapter dipswitch settings for the correct settings for your battery.

TROUBLESHOOTING

WARNING! Do not open or disassemble the Inverter. Attempting to service the unit yourself may cause the risk of electrical shock or fire. Please follow the safety instructions when working on the device.
If the device doesn’t work at all, an internal fuse might be blown. This happens always for a reason. Maybe there has been a short circuit, when connecting the inverter in wrong polarity. Don´t try to replace internal fuses yourself. The inverter has to be checked by the manufacturer or by an authorized service.

Symptom Possible Cause Solutions

The main Switch is ON, but there is no 230V AC output or any LED indicator
lights on.| There is no voltage at the DC input.| • Check that the battery fuse is not blown and intact.
• Check that all the DC input connections are tight.
• Check the continuity of the DC input circuit.
• If using a lithium battery, check to see if it as gone into protection/safe mode, if so, please follow your battery manufacturer’s instructions on how to reset the battery.
The polarity of the DC input has been reversed
and blown the internal fuses.
(NOTE: This may have caused permanent damage to the inverter, and void all warranty).| The inverter will need to be returned to Pro-User
Electronics for further assessment.
The inverter beeps once, Power LED indicator is green. But the connected
AC appliance does not turn on.| • Loose AC output connections.
• Short circuit of AC output wiring.
• The AC appliance is faulty.
• The AC appliance is switched oJ.| • Double check that all AC output connections are
tight and not loose (Consult a licensed electrician).
• Check for short circuits with your AC wiring.
• Test the AC appliance on a 230V AC socket.
• If there is still no output, contact Pro-User
Electronics.
The inverter beeps twice.| Low DC input voltage warning. The voltage at
the DC input is below 10 + 0.5V DC.| • Check that the battery is not flat and fully charged, recharge if low.
• Check that the battery cables are thick enough to carry the required current over the required length. Use thicker cable if required.
• Check for any loose connections on the DC
input circuit.
The inverter beeps three times, the red fault indicator LED illuminates
and there is no AC output.| Low DC input voltage protected warning. The
voltage at the DC input is below    10 + 0.5 V DC.| • Check that the battery is not flat and fully charged, recharge if low.
• Check that the battery cables are thick enough to carry the required current over the required length. Use thicker cable if required.
• Check for any loose connections on the DC
input circuit.
The inverter beeps  four times, the red fault indicator LED illuminates and there is no AC output.| Overvoltage detected on the DC input. When the voltage at the DC input is higher than 16 +0.5V DC the AC output will shut down.| • Check that the  voltage at the DC input terminals do not exceed 16.0V DC if so, attempt to lower the voltage of the battery and check battery charging voltages.
• Ensure that maximum charging voltage of any
chargers (e.g. solar controller) connected to
the battery are set below 16.0V DC.
The inverter beeps five times, the red fault indicator LED Illuminates
and there is no AC output.| The inverter is overheating. When the internal temperature exceeds 75°C the AC  output will shut down.| • Reset the inverter by turning it oJ and on again
and check to see if the cooling fans are working
(fans automatically turn on when the inverter is at 20% load or internal temperatures are at
45°C). If the cooling fans are not functioning, the
inverter will need further assessment, please
contact Pro-User Electronics.
• If the fans are functioning, check that all   ventilation slots and fan openings are not
obstructed. Also ensure that cool air is being
circulated to the inverter and make sure ambient temperatures do not exceed 45°C.
The inverter beeps eleven times, the red fault indicator LED illuminates and the inverter shuts down.| The inverter has detected a short circuit at the AC output.| Please check that the connected device is not
faulty and check  if there are no short circuits in the AC circuit.
The inverter is beeping Continuously, the red fault indicator LED Illuminates and there is no AC output.| The inverter has shut down due to overload.
Connected load has exceeded the surge
rating of the inverter.| • Disconnect the connected load.
• Reduce the connected load.

TECHNICAL SPECIFICATIONS

Model PSI300 PSI400 PSI600 PSI1000TX
Battery Voltage 10.5V —16V 10.5V — 16V 10.5V — 16V 10.5V —16V
Standby Current <0.25A <0.35A <0.46A <0.56A
Recommended Battery Capacity SLA/Gel/AGM:
>40Ah SLA/Gel/AGM:
> 50Ah SLA/Gel/AGM:
> 100Ah SLA/Gel/AGM:

160Ah
AC Output Voltage| 230V| 230V| 230V| 230V
Frequency| 50Hz| 50Hz| 50Hz| 50Hz
Transfer switch| No| No| No| Yes
Rated Output Power| 300W| 400W| 600W| 1000W
Surge Power| 450W (10s)| 600W (10s)| 900W (10s)| 1500W (10s)
Peak Power| 600W (2s)| 800W (2s)| 1200W (2s)| 2000W (2s)
Efficiency| >90%| >90%| >90%| >90%
USB Output| 5V 12.1A| SV / 2.1A| SV / 2.1A| 5V 12.1A
Dimensions LxWxH| 165x150x75mm
(housing)
215x150x75mm
(incl. terminals)| 185x150x75mm
(housing)
235x150x75mm
(incl. terminals)| 215x150x75mm
(housing)
265x150x75mm
(incl. terminals)| 355x150x75mm
(housing)
405x150x75mm
(incl. terminals)
Weight| 1.4kg| 1.6kg| 1.9kg| 2.8kg
Operating| -15°C — 40°C| -15°C — 40°C| -15°C — 40°C| -15°C — 40°C
Storage Temperature| -40°C — 85°C| -40°C — 85°C| -40°C — 85°C| -40°C — 85°C
Cooling| Air-Cooled| Air-Cooled| Air-Cooled| Air-Cooled
Remote Control with wiring| Optional| Optional| Included| Included
Battery Wiring| 4mm2 (80cm)| 4mm2 (80cm)| 6mm2 (80cm)| lOmm2 (80cm)
Model| PSI1500TX| PSI2000TX| PSI3000TX| PSI3000TX Hybrid
---|---|---|---|---
Battery Voltage| 10.5V— 16V| 10.5V —16V| 10.W — 16V| 10.5V — 16V
Standby Current| <0.65A| <0.7A| <1.2A| <1.2A
Recommended Battery Capacity| SLA/Gel/AGM:
250Ah| SLA/Gel/AGM:
320Ah| SLA/Gel/AGM:
480Ah| SLA/Gel/AGM:
480Ah
AC Output Voltage| 230V| 230V| 230V| 230V
Frequency| 50Hz| 50Hz| 50Hz| 50Hz
Transfer switch (by-pass)| Yes| Yes| Yes| Yes
Rated Output Power| 1500W| 2000W| 3000W| 3000W
Surge Power| 2250W (10s)| 3000W (10s)| 4500W (10s)| 4500W (10s)
Peak Power| 3000W (2s)| 4000W (2s)| 6000W (2s)| 6000W (2s)
Efficiency| >90%| >90%| >90%| >90%
USB Output| 5V / 2.1A| 5V / 2.1A| 5V / 2.1A| 5V / 2.1A
Dimensions LxWxH| 320x220x90mm
(housing)
380x220x85mm
(incl. terminals)| 385x220x85mm
(housing)
440x220x85mm
(incl. terminals)| 415x220x150mm
(housing)
510x220x150mm
(incl. terminals)| 415x220x150mm
(housing)
515x220x150mm
(incl. terminals)
Weight| 4.1 kg| 5.0kg| 7.6kg| 8.6kg
Operating Temperature| -15°C-40°C| -15°C —40°C| -15°C —40°C| -15°C — 40°C
Storage Temperature| -40°C — 85°C| -40°C — 85°C| -40°C — 85°C| -40°C — 85°C
Cooling| Air-Cooled| Air-Cooled| Air-Cooled| Air-Cooled
Remote Control with wiring| Included| Included| Included| Included
Battery Wiring| 16mm2 (80cm)| 25mm2 (80cm)| 35mm2 (80cm)| 35mm2 (80cm)
Solar Connection MC4| No| No| No| Yes
MPPT Charger 20A| No| No| No| Yes
Battery Charger 20A| No| No| No| Yes

MAINTENANCE

Make sure that the inverter is turned oJ while performing any maintenance. To keep your inverter operating properly, there is very little maintenance required. You should clean the exterior periodically with a dry cloth to prevent the build-up of dust and dirt. Also check and tighten the fasteners on the DC input terminals.

Warranty

Pro-User Electronics warrants this product for a period of 2 years from the date of purchase to the original purchaser. Warranty is not transferable. Warranty covers defect against workmanship and materials only. To obtain warranty service, please return the unit to the place of purchase or authorized Pro-User Electronics dealer together with your proof of purchase. The warranty is void if the product has been damaged or not used as described in this manual. Warranty is void if a non-authorized repair has been performed. Pro-User Electronics makes no other warranty expressed or implied. Pro-User Electronics is only responsible for repair or replacement of the defective product and is not responsible for any consequential damage or inconvenience caused by the defect.

Contact information:
Tradekar Benelux BV
Ohmweg 1
4104 BM Culemborg
The Netherlands
+31(0)345470990
Info@tradekar.com

Pro-User Electronics is part of Tradekar House of Leisure Brands

WWW.PRO-USER.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals