ELATION PROFESSIONAL KL FRESNEL 6 150W Warm White LED Light User Manual

June 5, 2024
ELATION PROFESSIONAL

KL FRESNEL 6™
user manual

©2021 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non- ELATION brands and product names are trademarks or registered trademarks of their respective companies.

ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.

Elation Professional USA I 6122 S. Eastern Ave. I Los Angeles, CA. 90040 323-582-3322 I 323-832-9142 fax I www.elationlighting.com i info@elationlighting.com

Elation Professional B.V. I Junostraat 2 I 6468 EW Kerkrade, The Netherlands +31 45 546 85 66 I +31 45 546 85 96 fax I www.elationlighting.eu I info@elationlighting.eu

Elation Professional Mexico I AV Santa Ma 30 I Parque Industrial Lerrna, Lerma, Mexico 52000 +52 728-282-7070

DOCUMENT VERSION

Due to additional product features and/or enhancements, an updated version of this document may be available online. Please scan the QR Code with your
a mobile device or visit
www.elationlighting.com for the latest revision/update of this manual, before installation and/or programming.

Date| Document Version| Software Version >| DMX Channel Modes| Notes
---|---|---|---|---
12/11/17| 1| 1.02| 1/2/3/4| Initial release.
01/31/18| 1.2| N/C| NO CHANGE| Added manual dimming control instructions.
11/29/18| 1.4| 1.06| 1/2/2-2/3/2-3/4| Added 2-2 Ch and 2-3 Ch DMX modes, gamma 1.0 brightness, and Stage2 dimming curve mode.
03/02/19| 1.6| 1.08| 1/2/3/4/5| Updated DMX channels and system menu.
08/20/20| 1.8| 1.10| NO CHANGE| Updated primary/secondary.
10/08/20| 2.0| N/C| NO CHANGE| Updated refresh frequency.
10/27/20| 2.2| N/C| NO CHANGE| Updated specifications.
06/17/21| 2.4| N/C| NO CHANGE| Add a standalone mode statement to the system menu section.
08/12/21| 2.6| N/C| NO CHANGE| Updated Manual Dimming Control

GENERAL INFORMATION

INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information.

UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event, damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

BOX CONTENTS
Barn Door
Gel Frame
Power Cable

CUSTOMER SUPPORT
Contact ELATION Service for any product-related service and support needs. Also visit forums.elationlighting.com with questions, comments or suggestions.

ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST323-582-3322 I Fax 323-832-9142 I support@elationlighting.com

ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET +31 45 546 85 63 I Fax +31 45 546 85 96 I support@elationlighting.eu

REPLACEMENT PARTS please visit parts.elationlighting.com

IMPORTANT NOTICE!

THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.

LIMITED WARRANTY (USA ONLY)

  1. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or services (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability whatsoever for loss and/or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner that Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual. D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bear identifying marks to that effect. E. Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
WARRANTY RETURNS

All returned service items whether under warranty or not, must be freight pre- paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem, as well as the R.A. number, must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without an R.A number clearly marked on the outside of the package will be refused and returned at the customer’s expense. You may obtain an R.A. number by contacting customer support.

SAFETY GUIDELINES

This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation
Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform the installation of this fixture and only the original rigging parts (omega brackets) included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufactures warranty and increase the risk of damage and/or personal injury.

PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED

THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.

DO NOT PLUG THE FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING THE FIXTURE!
NEVER TOUCH FIXTURES DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURES!

NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE!
RETINA INJURY RISK – MAY INDUCE BLINDNESS!
SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!

INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE FIXTURES TO RAIN AND MOISTURE!

SAFETY GUIDELINES

DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving.
DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
DO NOT operate the fixture if the power cord is frayed, crimped, damaged, and/or if any of the power cord connectors are damaged, and do not insert into the fixture securely with ease.
NEVER force a power cord connector into the fixture. If the power cord or any of its connectors is damaged, replace it immediately with a new one of a similar power rating.
DO NOT block any air ventilation slots.

All fan and air inlets must remain clean and never blocked.

Allow approx. 6” (15cm) between the fixture and other devices or a wall for proper cooling.
When installing fixtures in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always install fixtures with an appropriately rated safety cable.
Always disconnect fixtures from the main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.

During the initial operation of this fixture, light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
Consistent operational breaks will ensure fixtures will function properly for many years.

ONLY use the original packaging and materials to transport the fixture in for service.

MAINTENANCE GUIDELINES

DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!

CLEANING

Frequent cleaning is recommended to ensure proper function, optimized light output, and extended life. The frequency of cleaning depends on the environment in which the
fixture operates: damp, smoky or particularly dirty environments can cause a greater accumulation of dirt on the fixture’s optics. Clean the external lens surface at least every 20
days with a soft cloth to avoid dirt/debris accumulation.

NEVER use alcohol, solvents, or ammonia-based cleaners.

MAINTENANCE

Regular inspections are recommended to ensure proper function and extended life.
There are no user-serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.

Please refer to the following points during routine inspections:
A detailed electric check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.
Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation resulting in damage or injury as larger parts could fall.

Check for any deformations on the housing, color lenses, rigging hardware, and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).

Electric power supply cables must not show any damage, material fatigue, or sediments.

NEVER remove the ground prong from the power cable.

FIXTURE OVERVIEW

ELATION PROFESSIONAL KL FRESNEL 6 150W Warm White LED Light - FIXTURE
OVERVIEW

  1. Fuse
  2. Power In
  3. Power Out
  4. 5pin DMX In
  5. 5pin DMX Out
  6. 3pin DMX Out
  7. 3pin DMX In
  8. USB Software Update Port
  9. OLED Control Menu Display
  10. MODE Button
  11. UP Button
  12.  DOWN Button
  13. ENTER Button
  14. Manual Dimming Control Knob
  15. Manual Zoom Control Knob

INSTALLATION INSTRUCTIONS

FLAMMABLE MATERIAL WARNING
Keep fixtures a minimum of 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.

ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.

USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE. CHECK SILKSCREEN FOR MAX AMPS.

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

Fixtures MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.

Before rigging/mounting a single fixture or multiple interconnected fixtures for custom matrix designs to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.

The fixture’s ambient operating temperature range is 14° to 113°F. (-10° to 45°C) Do not use the fixture under or above this temperature.

Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas where unauthorized personnel might reach the fixture by hand.

NEVER stand directly below the fixture(s) when rigging, removing, or servicing.

Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that meets all local, national, and country codes and regulations. Allow approximately 15 minutes for the fixture to cool down before serving.

GEL FRAME AND BARN DOOR INSTALLATION
The fixture has 2 slots on the front to hold the GEL FRAME and BARN DOOR. The first smaller slot is for the GEL FRAME and the second larger slot is for the BARN DOOR.

The fixture also has a top lock that secures these accessories to the fixture.

ELATION PROFESSIONAL KL FRESNEL 6 150W Warm White LED Light - BARN DOOR
INSTALLATION

Secure the mini SAFETY CABLE to the BARN DOOR and the top lock.

  1. Lift up the lock on top of the fixture and insert GEL FRAME into the first slot closest to the fixture.
  2. Insert BARN DOOR into the second slot.
  3. Lower the lock on top of the fixture to secure both the GEL FRAME and BARN DOOR.
  4. Secure the mini SAFETY CABLE to the BARN DOOR and top lock.
CLAMP INSTALLATION

When mounting the fixture to the truss, be sure to secure an appropriately rated professional grade rigging clamp to the fixture using an M10 screw fitted through one of the 3 holes of the yoke bracket. The fixture provides a built-in rigging point for a SAFETY CABLE. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle.

ELATION PROFESSIONAL KL FRESNEL 6 150W Warm White LED Light - CLAMP
INSTALLATION

RIGGING
Overhead rigging requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. The fixture is fully
operational in the specific mounting positions illustrated below.

ELATION PROFESSIONAL KL FRESNEL 6 150W Warm White LED Light -
RIGGING

SAFETY CABLE

ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL  NOT DROP IF THE CLAMP FAILS.

SYSTEM MENU

The fixture includes an easy-to-navigate system menu. The control panel (see image below)located on the side of the fixture provides access to the main system menu and is where all necessary system adjustments are made to the fixture. During normal operation, pressing the MODE button once will access the fixture’s main menu. Once in the main menu, you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE button.

NOTE: To access the LCD Menu Control Display when locked, press and hold the MODE button for 3 seconds. The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press.

STANDALONE

Press the MODE button to access the fixture’s main menu. Use the UP and DOWN buttons to navigate to DMX Settings and press the ENTER button. Navigate to No DMX
Status and press the ENTER button. Navigate to Standalone and press the ENTER button.

ELATION KL FRESNEL 6
SYSTEM MENU


Features are subject to change without notice.

Supports Software
Versions: a. 1.02

MAIN MENU| SUBMENU| OPTIONS / VALUES (Default Settings in BOLD)| DESCRIPTION
Address| Address| 001 – XXX| Set DMX Address Setting
UserMode| User Mode| 1CH, 2CH, 3CH, 4CH| Set DMX Channel / User Mode
Function| Status| Lost Dmx| Hold / Black| Function If NO DMX Detected
Display| ON / OFF| OLED Display Screen Saver Mode When ON goes off after 30 seconds. ONLY WHEN DMX IS CONNECTED.
LCD. Set| Key Lock| ON / OFF| Control Front Panel Buttons Key Lock
Flash| ON / OFF| The display flashes when NO DMX
Invert| OFF / ON| Flip LCD Display 180°
Temp. C/F| F / C| Temperature Switch Between C7 F°
Dim Curve| Standard, Stage, TV, Architec, Theatre| Set Dimmer Curve Mode
Disp. Set| ADDR, Disp.CH, Salve| Set Information to Display on LCD
Fan. Set| Led Fan| I Auto, High, Low| Set LED Fan Speed
Gamma| 2.0, 2.2, 2.4, 2.8| Set Gamma Brightness
Frequent| 900kHz, 1000kHz, 1100kHz, 1200kHz, 1300kHz, 1400kHz, 1500kHz, 2500kHz, 4000kHz, 5000kHz, 10kHz, 15kHz, 20kHz, 25kHz| Set LED Refresh Frequency
USB Update| OFF, ON| Software Update Port – Contact Service
PDF| OFF, ON| Restore Factory Settings
Info| Timeline| Current| 000 (Hours)| Fixture Run Time From Power ON
Total| 000 (Hours)| Fixture Total Run Time
Last| 000 (Hours)| Clear Fixture Last Run Time
Password| PIN= 050| Enter PIN to Access Clear Last. Menu
Clear| ON / OFF| Reset Fixture Last Run Time
Temp info| Led Temp| 000 F (C)| Temperature of LED
Err. Info| Error Record 1 – Error Record 10| Display 10 Recent Error Messages
Modeling| KLF6| Display Model Name
Software| Software| V1.02| Software Version (Greater than or Equal to)
Test| Mantri| Dimmer, Strobe| Test Functions

SYSTEM MENU UPDATE WITH SOFTWARE UPDATE VERSION ≥1.06
See highlighted items below which have been updated with this software update.

SYSTEM MENU UPDATE WITH SOFTWARE UPDATE VERSION .a. 1.08

Features are subject to change without notice.
MAIN
MENU
| SUBMENU| OPTIONS / VALUES (Default Settings in BOLD)| DESCRIPTION
Function| User Mode| 1CH, 2CH, 2-2CH, 3CH, 2-3CH, 4CH| Set DMX Channel / User Mode
Gamma| 1.0, 2.0, 2.2, 2.4, 2.8| Set Gamma Brightness
Dim Curve| Standard, Stage, TV, Architec, Theatre, Stage2| Set Dimmer Curve Mode
Address| Address| 001 – XXX| Set DMX Address Setting
UserMode| User Mode| Dimmer / Dimmer 16bit / 3CH / Standard / Extended| Set DMX Channel / User Mode
Function| Status| Lost Dmx| Hold / Black| Function If NO DMX Detected
LCD. Set| Display| ON / OFF| OLED Display Screen Saver Mode When ON goes off after 30 seconds. ONLY WHEN DMX IS CONNECTED.
Key Lock| ON / OFF| Control Front Panel Buttons Key Lock
Flash| ON / OFF| The display flashes when NO DMX
Invert| ON / OFF| Flip LCD Display 180°
Temp. C/F| C / F| Temperature Switch Between C7 Fe.
Dim Mode| Standard, Stage, TV, Architec, Theatre. Stage2, 0.0s, 0.1s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, 0.7s, 0.8s, 0.9s, 1.0s, 1.5s, 2.0s, 3.0s, 4.0s, 5.0s, 6.0s, 7.0s, 8.0s, 9.0s, 10.0s| Set Dimmer Mode
Disp. Set| ADDR, Disp CH Salve| Set Information to Display on LCD
Fan. Set| Led Fan| I Auto / High / Low| Set LED Fan Speed
Dim Curve| Linear / Square / INV-Square / S-Curve| Set Dimmer Curve Mode
Frequent| 900kHz, 1000kHz, 1100kHz, 1200kHz, 1300kHz, 1400kHz, 1500kHz, 2500kHz, 4000kHz, 5000kHz, 10kHz, 15kHz, 20kHz, 25kHz| Set LED Refresh Frequency
USB_Data| ON, OFF| Software Update Port – Contact Service
Primary| ON, OFF|
PDF| ON, OFF| Restore Factory Settings
Info| Timeline| Current| 000 (Hours)| Fixture Run Time From Power ON
Total| 000 (Hours)| Fixture Total Run Time
Last| 000 (Hours)| Clear Fixture Last Run Time
Password| PIN= 050| Enter PIN to Access Clear Last. Menu
Clear| ON / OFF| Reset Fixture Last Run Time
Temp info| Led Temp| 000 C / F| Temperature of LED
Err. Info| Error Record 1 – Error Record 10| Display 10 Recent Error Messages
Modeling| KL F6| Display Model Name
Software| Software| V1.08| Software Version
(Greater than or Equal to)
Test| Mantri| Dimmer| 000 – 255| Manual Control Functions
Strobe| 000 – 255

DIMMER CURVE MODES – Dim Curve

Select desired DIMMER MODE (Standard, Stage, TV, Architectural, Theatre, Stage2).
STAGE 2 DIMMING CURVE MODE ADDED WITH SOFTWARE UPDATE VERSION ≥1.06

MANUAL DIMMING CONTROL

  • FEATURE IS DISABLED WHEN DMX INPUT CABLE IS CONNECTED TO FIXTURE!
    TO USE THE MANUAL DIMMING KNOB, DISCONNECT DMX CABLE IF CONNECTED.

Follow the steps below to enable the manual DIMMING control knob.

  1. Access the fixture system menu by navigating to the Test menu and then accessing the ManCtrl sub-menu.
    Test| ManCtrl| Dimmer, Strobe| Manual Control Functions
    ---|---|---|---

NOTE: To access the LCD Menu Control Display when locked/OFF, press and hold the MODE button for 3 seconds.

**2. Select the Stobe menu, set it to the value of 255 (LED ON), then exit the fixture system menu.
3. Push the
DIMMING** knob to unlock, rotate to the desired level, and push the knob again to lock.
Repeat this process each time a dimmer adjustment is desired.
ELATION PROFESSIONAL KL FRESNEL 6 150W Warm White LED Light - LCD
DISPLAY

DMX CHANNEL FUNCTIONS AND VALUES

ELATION KL FRESNEL 6
DMX Channel Values / Functions (4 DMX Channels)

Supports Software Versions: ≥ 1.02
Features are subject to change without notice.
MODE / CHANNEL| VALUE| FUNCTION
1CH| 2CH| 3CH| 4CH
1| 1| 1| 1| | DIMMER INTENSITY
000-255| Dimmer 0 to 100%
| | | 2| | DIMMER INTENSITY FINE
000-255| Dimmer FINE Adjustment
| 2| 2| 3| | SHUTTER, STROBE
000-031| LED OFF
032-063| LED ON
064-095| Strobe Effect SLOW to FAST
096-127| LED ON
128-159| Pulse Effect In Sequences
160-191| LED ON
192-223| Random Strobe Effect SLOW to FAST
224-255| LED ON
| | 3| 4| | DIMMER MODES
000-020| Standard
201-040| Stage
041-060| TV
061-080| Architectural
081-100| Theatre
101-255| Default to Setting on Fixture

DMX CHANNEL UPDATE WITH SOFTWARE UPDATE VERSION ≥1.06
See highlighted items below which have been updated with this software update.


MODE/CHANNEL| VALUE| FUNCTION
1CH| 2CH| 2-2CH| 3CH| 2-3CH| 4CH
1| 1| 1| 1| 1| 1| | DIMMER INTENSITY
000-255| Dimmer Otto 100%
| | 2| | 2| 2| | DIMMER INTENSITY FINE
000-255| Dimmer Fine Adjustment
| 2| | 2| | 3| | SHUTTER, STROBE
000-031| LED OFF
032-063| LED ON
064-095| Strobe Effect SLOW to FAST
096-127| LED ON
128-159| Pulse Effect In Sequences
160-191| LED ON
192-223| Random Strobe Effect SLOW to FAST
224-255| LED ON
| | | 3| 3| 4| | DIMMER MODES
000-020| Standard
021-040| Stage
041-060| TV
061-080| Architectural
081-100| Theatre
101-120| Stage 2
121-255| [Default to Setting on Fixture

DMX CHANNEL UPDATE WITH SOFTWARE UPDATE VERSION ≥1.08

ELATION KL FRESNEL 6
DMX Channel Values / Functions (5 DMX Channels)


Supports Software Versions: ≥ 1.08

Features are subject to change without notice.

MODE/CHANNEL| VALUE| FUNCTION
Dimmer| Dimmer
16bit
| 3CH| Standard| Extended
| 1| 1| 1| 1| | DIMMER INTENSITY
000-255| Dimmer 0 to 100%
| 2| | 2| 2| | DIMMER INTENSITY FINE
000-255| Dimmer FINE Adjustment
| | 2| 3| 3| | SHUTTER  STROBE
000-031| LED OFF
032-063| LED ON
064-095| Strobe Effect SLOW to FAST
096-127| LED ON
128-159| Pulse Effect In SLOW to FAST
160-191| LED ON
192-223| Random Strobe Effect SLOW to FAST
224-255| LED ON
| | 3| 4| 4| | DIMMER MODES I DIMMER DELAY TIMES
000-020| Standard
021-040| Stage
041-060| TV
061-080| Architectural
081-100| Theatre
101-120| Stage 2
121| Dimmer Delay Time 0.0 seconds
122| Dimmer Delay Time 0.1 seconds
123| Dimmer Delay Time 0.2 seconds
124| Dimmer Delay Time 0.3 seconds
125| Dimmer Delay Time 0.4 seconds
126| Dimmer Delay Time 0.5 seconds
127| Dimmer Delay Time 0.6 seconds
128| Dimmer Delay Time 0.7 seconds
129| Dimmer Delay Time 0.8 seconds
130| Dimmer Delay Time 0.9 seconds
131| Dimmer Delay Time 1.0 seconds
132| Dimmer Delay Time 1.5 seconds
133| Dimmer Delay Time 2.0 seconds
134| Dimmer Delay Time 3.0 seconds
135| Dimmer Delay Time 4.0 seconds
136| Dimmer Delay Time 5.0 seconds
137| Dimmer Delay Time 6.0 seconds
138| Dimmer Delay Time 7.0 seconds
139| Dimmer Delay Time 8.0 seconds
140| Dimmer Delay Time 9.0 seconds
141| Dimmer Delay Time 10.0 seconds
142-255| Default
MODE/CHANNEL| VALUE| FUNCTION
---|---|---
Dimmer| Dimmer 16bit| 3CH| Standard| Extended
| | | | 5| | LED REFRESH RATE I DIMMER CURVES’
Hold selected DMX value for 5 seconds to set LED Refresh Rate.
000-100| IDLE
101-105| 900 kHz

106-110| 1000 kHz
111-115| 1100 kHz

116-120| 1200 kHz
121-125| 1300 kHz

126-130| 1400 kHz
131-135| 1500 kHz

136-140| 2500 kHz
141-145| 4000 kHz

146-150| 5000 kHz*
151-155| 10,000 kHz’
156-160| 15,000 kHz’
161-165| 20.000 kHz’
166-170| 25.000 kHz’
171-200| IDLE
201-210| DIMMER CURVE LINEAR (DEFAULT)
211-220| DIMMER CURVE SQUARE
221-230| DIMMER CURVE INVERSE SQUARE
231-240| DIMMER CURVE S-CURVE
241-255| IDLE

SPECIFICATION

SOURCE
150W >95CRI 3,000K Warm White LED
50,000 Hour Average LED Life
May vary depending on several factors including but not limited to:
Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.

PHOTOMETRIC DATA
6,500+ Total Lumen Output
17,829 LUX 1,656 FC @6.6’ (2m) (Min Zoom / Full ON)
4,412 LUX 410 FC @6.6’ (2m) (Max Zoom / Full ON)
Zoom Range 15° – 38°
Beam Angle 15.5° – 38°
Field Angle 23.4° – 51.8°

EFFECTS
Manual Zoom
Electronic Dimmer and Strobe
Variable 16-bit Dimming Modes and Curves

COLOR
Warm White 3,000K

CONTROL / CONNECTIONS
Manual and DMX Controlled Dimmer and Shutter
Dimmer and Zoom Rotary Dials
(5) DMX Channel Modes (1 / 2 / 3 / 4 / 5)
4 Button Control Panel LCD Menu Display
RDM (Remote Device Management)
3/5pin DMX and IP65 Locking Power Cable In/Out
With Wired Digital Communication Network

SIZE / WEIGHT
Length: 19.62” (498.5mm)
Width: 10.75” (273mm)
Vertical Height: 15.47” (393mm)
Weight: 18.5 lbs. (8.4kg)

ELECTRICAL / THERMAL
AC 100-240V – 50/60Hz
180W Max Power Consumption
5°F to 113°F (-15°C to 45°C)
Power Linking: 6Pcs @ 110V / 14Pcs @ 240V

INCLUDED ITEMS
Gel Frame and Rotating Barn Doors
IP65 Locking Power Cable
Barn Doors

APPROVALS / RATINGS

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

  • Reorient or relocate the device.
  • Increase the separation between the device and the receiver.
  • Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

ELATION PROFESSIONAL KL FRESNEL 6 150W Warm White LED Light - DIMENSIONAL
DRAWINGS

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

OPTIONAL ACCESSORIES

ORDER CODE ITEM
QUICK RIG CLAMP Low Profile Quick Release Clamp
AC3PDMX5PRO 5 ft. (1.5m) 3pin PRO DMX Cable
AC5PDMX5PRO 5 ft. (1.5m) 5pin PRO DMX Cable
NEU088 3 ft. (1m) Power Cable
Additional Cable Lengths Available

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELATION PROFESSIONAL User Manuals

Related Manuals