EUROfase-EF60-20-AMP-Per-Rocker-Switch-PRODUCT

Product Specifications:

  • Model: DUPLEX Two Single Pole Switch
  • Rated Amperage per Rocker Switch: 20 Amps
  • Voltage Range: 120/277 VAC
  • Maximum Wattage:
    • 120 VAC = 1800 Watts
    • 208/220 VAC = 3000 Watts
    • 240/277 VAC = 4000 Watts

Product Usage Instructions:

Installation:

  1. Ensure the power supply is turned off before starting the installation.
  2. Connect the red lead wires to the L2 terminal for each individual rocker switch.
  3. For 120 & 277 VAC applications, replace Neutral with L2.
  4. Securely fasten the black wire to the A1 terminal and the ground wire to the B1 terminal.
  5. Follow proper wiring procedures as per local electrical codes.
  6. If unsure, consult a licensed electrician for installation.

Usage:
Each individual rocker switch is rated for a maximum of 20 Amps. Make sure not to exceed the maximum wattage limits based on the voltage range specified above.

Frequently Asked Questions (FAQ):

  • Q: What is the maximum amperage rating for each rocker switch?
    A: Each rocker switch is rated for a maximum of 20 Amps.

  • Q: Can I exceed the recommended wattage limits for each voltage range?
    A: It is not recommended to exceed the specified wattage limits to ensure safe operation and prevent damage to the product.

  • Q: Do I need to hire a licensed electrician for installation?
    A: Yes, it is recommended that all Eurofase products are installed by a licensed electrician to ensure proper installation and safety.

DUPLEX TWO SINGLE POLE SWITCH WIRING 20 AMP PER ROCKER SWITCH

3 WIRE APPLICATION

FOR INSTALLING ONE HEATER WITH TWO ELEMENTS

EUROfase-EF60-20-AMP-Per-Rocker-Switch-

APPLICABLE ELECTRICAL CODES AND REGULATIONS MUST BE ADHERED TO WHEN INSTALLING AND USING IT.

WARNING:

  • Before wiring, turn off the power at the circuit breaker or fuse, to avoid a fire, shock, or death.
  • The devices should only be used with copper wires or copper-clad wires.
  • Installing a combination outlet or pilot light requires a neutral wire. An electrician should be consulted if you are unsure of the wiring polarity. Do not use to replace a switch that had been controlling a light with only two wires present.
  • Break-off fin should only be removed when installing for separate feed (2 circuit) operation.
  • Voltage is measured from line to line must not exceed 277V when using in a separate feed application.
    1. Remove approximately 5/8″ (1.6 cm) insulation from wire.
    2. Connect wires as shown: Loop wires clockwise 3/4 turn around terminal screws. Tighten screws over wire loops with a force of  12-14 in.-lbs. of torque.
    3. Attach wallplate and restore power. Installation is complete.

EACH INDIVIDUAL ROCKER SWITCH IS RATED FOR 20 AMPS MAX.

NOTE: Replace Neutral with L2 for 120 & 277 VAC Applications.
Two Single Pole Single Throw Switches

  • Range:120/277 VAC
  • Recommended not to Exceed
  • 120 VAC = 1800 Watts Max-Per Switch
  • 208/220 VAC = 3000 Watts Max-Per Rocker Switch
  • 240/277 VAC = 4000 Watts Max-Per Rocker Switch
  • 20 Amps Max-Per Rocker Switch

NOTE: ALL EUROFASE PRODUCTS MUST BE INSTALLED BY A LICENSED ELECTRICIAN

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

EUROfase User Manuals

Related Manuals