EUROfase EF60 20 AMP Per Rocker Switch Instruction Manual
- May 15, 2024
- EUROfase
Table of Contents
EUROfase EF60 20 AMP Per Rocker Switch
Product Specifications:
- Model: DUPLEX Two Single Pole Switch
- Rated Amperage per Rocker Switch: 20 Amps
- Voltage Range: 120/277 VAC
- Maximum Wattage:
- 120 VAC = 1800 Watts
- 208/220 VAC = 3000 Watts
- 240/277 VAC = 4000 Watts
Product Usage Instructions:
Installation:
- Ensure the power supply is turned off before starting the installation.
- Connect the red lead wires to the L2 terminal for each individual rocker switch.
- For 120 & 277 VAC applications, replace Neutral with L2.
- Securely fasten the black wire to the A1 terminal and the ground wire to the B1 terminal.
- Follow proper wiring procedures as per local electrical codes.
- If unsure, consult a licensed electrician for installation.
Usage:
Each individual rocker switch is rated for a maximum of 20 Amps. Make sure
not to exceed the maximum wattage limits based on the voltage range specified
above.
Frequently Asked Questions (FAQ):
-
Q: What is the maximum amperage rating for each rocker switch?
A: Each rocker switch is rated for a maximum of 20 Amps. -
Q: Can I exceed the recommended wattage limits for each voltage range?
A: It is not recommended to exceed the specified wattage limits to ensure safe operation and prevent damage to the product. -
Q: Do I need to hire a licensed electrician for installation?
A: Yes, it is recommended that all Eurofase products are installed by a licensed electrician to ensure proper installation and safety.
DUPLEX TWO SINGLE POLE SWITCH WIRING 20 AMP PER ROCKER SWITCH
3 WIRE APPLICATION
FOR INSTALLING ONE HEATER WITH TWO ELEMENTS
APPLICABLE ELECTRICAL CODES AND REGULATIONS MUST BE ADHERED TO WHEN INSTALLING AND USING IT.
WARNING:
- Before wiring, turn off the power at the circuit breaker or fuse, to avoid a fire, shock, or death.
- The devices should only be used with copper wires or copper-clad wires.
- Installing a combination outlet or pilot light requires a neutral wire. An electrician should be consulted if you are unsure of the wiring polarity. Do not use to replace a switch that had been controlling a light with only two wires present.
- Break-off fin should only be removed when installing for separate feed (2 circuit) operation.
- Voltage is measured from line to line must not exceed 277V when using in a separate feed application.
- Remove approximately 5/8″ (1.6 cm) insulation from wire.
- Connect wires as shown: Loop wires clockwise 3/4 turn around terminal screws. Tighten screws over wire loops with a force of 12-14 in.-lbs. of torque.
- Attach wallplate and restore power. Installation is complete.
EACH INDIVIDUAL ROCKER SWITCH IS RATED FOR 20 AMPS MAX.
NOTE: Replace Neutral with L2 for 120 & 277 VAC Applications.
Two Single Pole Single Throw Switches
- Range:120/277 VAC
- Recommended not to Exceed
- 120 VAC = 1800 Watts Max-Per Switch
- 208/220 VAC = 3000 Watts Max-Per Rocker Switch
- 240/277 VAC = 4000 Watts Max-Per Rocker Switch
- 20 Amps Max-Per Rocker Switch
NOTE: ALL EUROFASE PRODUCTS MUST BE INSTALLED BY A LICENSED ELECTRICIAN