Eurofase HEATING EF40 Urban Fireplaces Instruction Manual

May 15, 2024
Eurofase HEATING

Eurofase HEATING logo

FOR MODELS:

EF40, EF50, EF60

INSTALLATION, INSTRUCTION & SERVICE MANUAL


Eurofase HEATING EF40 Urban Fireplaces

WARNING
CANCER AND REPRODUCTIVE HARM
www.P65Warning.ca.gov

PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE.
READ THIS MANUAL CAREFULLY. SEE INSIDE COVER FOR IMPORTANT INFORMATION ABOUT THIS MANUAL. KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE.

Version 20230817

Thank You

Thank you for choosing Eurofase Heating to meet your heating needs. This manual is designed for our EF40, EF50, and EF60 series of heaters.

In order to ensure your heater provides efficient, safe and comfortable heat, please take the time to review this manual.

Before installing your heater, review the safety information found on page 4, page 5 and page 9. Strict adherence to these guidelines is necessary to prevent personal injury or property damage.

Pages 9 through 16 reviews essential installation and assembly instructions, containing placement and orientation guidelines that are extremely important to a safe and efficient installation.

Please keep this manual in a safe place for future reference and urgent needs.

Eurofase HEATING logo

Head Office:
33 West Beaver Creek Road, Richmond Hill, ON L4B 1L8 Canada
Tel: 1.800.660.5391
Email: [email protected]
EurofaseHeating.com

Note: Eurofase Heating reserves the right to make changes to specifications, parts, components and equipment without prior notification.
This Installation, operation and service manual may not be reproduced in any form without prior written consent from Eurofase Heating.

Warnings

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING OR USING HEATER.

This unit may cause a shock or possible ignition if service is attempted without first disconnecting its power source.

Keep electrical cords, drapery, furnishings and other combustible materials at least 3.3ft (1m) from the heater’s front fascia and keep them away from the two sides and rear.

A LICENSED ELECTRICIAN IS REQUIRED TO INSTALL THIS PRODUCT.

GOOD TO KNOW!

For optimal heater performance and longevity, a 15 minute cool down period is recommended after 4 hours of continuous usage.

WALL & CEILING HEIGHT/CLEARANCES

For the Canadian market, Heater must be installed more than 8ft (2.4m) off the floor.

For the American market, Heater must be installed more than 6ft (1.8m) off the floor.

  • All adjacent heaters must be installed more than 3.3ft (1m) apart from each other.
  • Heaters that are greater than 240V are for Commercial use only and have a higher risk of fire. These should never be used as a residential heater.
  • Heater should never be blocked by any other object.
  • Heater should not be operated within 25ft (7.6m) of any flammable or explosive materials.
  • Heater is not to be used if the heating element is damaged or cracked.
  • According to local wiring codes, disconnection provisions should be incorporated in the appliance.
  • When possible, install heaters under a protective covering such as a roof when it is used in an outdoor application. This will prolong the product’s life and maintain its appearance.

|

WALL-MOUNTED

|

CEILING-MOUNTED

---|---|---

Min. distance from adjacent wall

| 18”| 18”
Min. distance from ceiling| 12”|

6”

Min. distance from vertical surface

| 18”| 18”
Min. distance from floor| 72” for UL Listed.
96” for CUL Listed| 72” for UL Listed.
96” for CUL Listed

PLEASE REFER TO THE FLUSH MOUNT INSTRUCTION MANUAL FOR FLUSH MOUNT APPLICATIONS

WARNING

The heater should only be used as described in this manual. Any use not recommended by the manufacturer may result in fire, electric shock, or personal injury.

Read and understand the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. Only trained, qualified personnel with proper electrical experience may install or service this equipment. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, serious injury, or death.

Damage caused by improper use is not the responsibility of the manufacturer. It is important to use this appliance responsibly and to follow all the procedures, warnings, and safety instructions contained in this manual. Any use not recommended by the manufacturer may result in fire, electric shock, or personal injury.

Some parts of this product can become very hot and cause burns. Keep bare skin away from hot surfaces to avoid burns. The front, sides, and rear of the heater should be at least 3.3ft (1m) away from flammable materials such as furniture, pillows, linen, papers, clothes, etc.

Placement of explosive objects, flammable objects, liquids, and vapors close to the heater may result in explosion, fire, property damage, serious injury, or death. Do not store or use explosive objects, liquids, or vapors in the vicinity of the heater.

The outside surfaces of the heater are hot during operation and after operation. If contact is made, permanent skin damage may occur. Do not move, handle, or service the unit during operation or while hot.

In order to avoid overheating, never under any circumstances cover the appliances during operation, as this would lead to dangerous overheating.

Failure to comply with the published clearances to combustibles could result in personal injury, death, and/or property damage.

Particular attention must be given where children and vulnerable people are present. Children should be kept away unless continuously supervised.

If the power cable has been damaged, it must be replaced by the manufacturer or the technical service center or by a qualified person so as to avoid all risks.

Do not attempt to alter the unit in any manner, including painting the surface of the unit.

Do not insert any foreign objects to the front cover or front opening of the heater as this may cause an electric shock or fire or damage the heater.

Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.

INSTALLATIONS:

Installations must comply with local building codes; all electrical connection must be in compliance with the National Electric Code (NEC) and local codes for outdoor wiring. Contact the local building inspector and/or fire marshal for guidance.

The packaging needs to be removed before installation, please contact supplier if there is any damage or defectiveness on the appliance.

Heater and switches should not be installed near bathtubs, wash basins, showers, sinks, swimming pools, recreational vehicles, boats, and wardrobes.

The appliance must not be located in front of or below a fixed socket-outlet.

Before using the appliance check the label on the heater for proper voltage, please make sure the requirement of the power socket and power supply line correspond to the load specified. Check the current capacity of your fuses. HEATER MUST CONNECT TO EARTH PROVIDED SOCKET.

Safety warning labels must be maintained on the heater. Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels.

Never place the power cable on top of the heater or under any coverings. Power cord need to be placed away from the traffic areas.

The heater can only mount horizontally to prevent from swaying and putting stress on the heating elements. Check local codes for seismic bracing requirements for outdoor heating equipment.

Air flow must not be restricted. The space above the heater must not be enclosed in order to allow air for ventilation.

CAUTION – High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at least 3.3 feet (1m) from the front of the heater and away from the side and rear.

Each enclosed area within which the heater is located shall have a temperature control device.

The heater does not feature a device to control ambient temperature. All users should be made aware of all aspects of operation and safety and these instructions should be retained for reference.

Overview

Eurofase HEATING EF40 Urban Fireplaces - a1

1. Standard Grille
2. Heater Body
3. Quartz Element

What’s in the box?

Please inspect that all parts are included in the package.

Instruction Manual (x1)

Installation Template

Heating Element (x2)

Parts Bag:                     Mounting Bracket (x2)
Outer Nut (x4)
Washer (x4)

Important Note

The contents of this document and the specifications of this product are subject to change without notice.

Eurofase Heating reserves the right to make changes to the specifications and materials contained herein without notice.

Please contact our customer service department or visit our website atEurofaseHeating.com for the latest instruction manual.

Applicable Codes and Standards

Installation of this heater shall be in accordance with local codes, or in the absence of local codes, the National Electrical Code, NFPA 70, or the Canadian Electrical Code, Part 1, C22.1.

Eurofase Heating Heaters are designed and manufactured for residential / commercial heating applications for indoor and outdoor use, in accordance with the Standard for Fixed and Location-Dedicated Electric Room Heaters, UL 2021, and the Canadian Standard for Electric Air Heaters, CSA C22.2 No. 46.

Technical Specifications

MODEL #

| **RATED OUTPUT WATTAGE*| SUPPLY VOLTAGE| SUPPLY AMP DRAW| DIMENSIONS| WEIGHT
---|---|---|---|---|---
EF40208| 4000W| 208V| 19.2A
| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)|

14 lbs (6.36Kg)

EF40240

| 4000W| 240V| 16.6A| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)| 14 lbs (6.36Kg)
EF40277| 4000W| 277V| 14.4A| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)|

14 lbs (6.36Kg)

EF40480

| 4000W| 480V| 8.33A| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)| 14 lbs (6.36Kg)
EF50208| 5000W| 208V| 24.0A
| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)|

14 lbs (6.36Kg)

EF50240

| 5000W | 240V| 20.8A| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)| 14 lbs (6.36Kg)
EF50277| 5000W| 277V| 18.0A| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)|

14 lbs (6.36Kg)

EF50480

| 5000W| 480V| 10.4A| 8.17” x 39.37” x 9.35”
(20.75 x 99.9 x 23.75cm)| 14 lbs (6.36Kg)
EF60208| 6000W| 208V| 28.8A
| 8.17” x 61.26” x 9.35”
(20.75 x 156.60 x 23.75cm)|

21 lbs (9.54 Kg)

EF60240

| 6000W| 240V| 25A| 8.17” x 61.26” x 9.35”
(20.75 x 156.60 x 23.75cm)| 21 lbs (9.54 Kg)
EF60277| 6000W| 277V| 21.6A| 8.17” x 61.26” x 9.35”
(20.75 x 156.60 x 23.75cm)|

21 lbs (9.54 Kg)

EF60480

| 6000W| 480V| 12.5A**| 8.17” x 61.26” x 9.35”
(20.75 x 156.60 x 23.75cm)|

21 lbs (9.54 Kg)

  • Actual output wattage ranging 90% to 105% of the rated output wattage
    ** Load calculation may change on a 3-phase system feed.
Electrical Installations

Turn the heater on only when you need heat and avoid any misuse.

Do not use the heater if the ambient temperature exceeds 80°F (26.6°C). Before connecting the appliance make sure that the voltage is the same as indicated on the device and the line supply is corresponding to the relevant electrical code.

This heater MUST be permanently installed and hard wired by an authorized/licensed person. Do not perform maintenance, or carry out installation or assembly procedure while electrical power is switched on.

ELECTRIC SHOCK HAZARD!
Serious injury or death may occur. Disconnect from electrical supply before installing or servicing this heater. Read and follow installation clearance requirements outlined in this manual. The Appliance MUST be connected to a properly grounded electrical source.

WIRING DIAGRAM
EF40, EF50 AND EF60 MODELS

  1. EARTH WIRE
  2. Junction Box
  3. L1(BLACK)
  4. L2(RED)
  5. HEATER ELEMENT 1
  6. HEATER ELEMENT 2

WIRING DIAGRAM USING Eurofase Heating DUPLEX SWITCH
MODELS EFSWPS AND EFSWPW (sold separately)

This wiring diagram is for reference only. Please refer to the complete installation/ wiring diagram that come with the Eurofase switch for correct installation. Please contact us for technical support/ obtain the latest installation and wiring guide.

Eurofase HEATING EF40 Urban Fireplaces - b3

  • Replace L2 with Neutral for 277 VAC Application
Mounting Height / Clearances
  1. The minimum installation height from the floor to the heater shall be:
    6ft (183 cm) American Standard, 8ft (244 cm) Canadian Standard

  2. The minimum clearances from the ceiling, walls and other objects are shown in the pictures below.

  3. Building materials with low heat tolerance (i.e. plastics, vinyl siding, canvas, tri-ply, etc.) may be subject to degradation at lower temperatures. It is the installer’s responsibility to ensure that adjacent materials are protected from deterioration.

Eurofase HEATING EF40 Urban Fireplaces - c7

  1. Objects below the heater
  2. FLOOR

  1. Greater than or equal to 18″ (45.7 cm)

  2. Greater than or equal to 6″ (15.2cm)

  3. Greater than or equal to 12″ (30.4 cm)


  1. Less than 6″ (15.2cm)

Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.

Once the product is powered, it automatically goes into ON mode. It will take a few minutes after powering on to reach the maximum temperature.

Ceiling Mount

Eurofase HEATING EF40 Urban Fireplaces - d1

  1. CEILING MOUNT APPLICATION
  2. Optional Chain Mounted (not included)
  3. Rotatable on both ends.

Make sure heater is leveled equally during installation to achieve equal heat distribution. Improper leveling can cause shorter lifespan of the Quartz Element.

Wall Mount

Eurofase HEATING EF40 Urban Fireplaces - d2

  1. WALL MOUNT APPLICATION
  2. Install downwards only
Flush Mount

Eurofase HEATING EF40 Urban Fireplaces - d3

  1. 2 x 8 STUDS MINIMUM
  2. FLUSH MOUNT APPLICATION
  3. Accessible Junction Box
  4. Beam
  5. Type X 5/8″ Drywall
  6. Whip
  7. Ceiling
  8. WHIP
  9. MINIMUM
    5/8” TYPE X DRY WALL
    ONE HOUR FIRE-RATED

EF61FMPFS – 61″ FLUSH MOUNT FRAME*
Eurofase HEATING EF40 Urban Fireplaces - d4

EF39FMPFS – 39″ FLUSH MOUNT FRAME*

Please reference Flush Mount Instruction Manual for Flush Mount applications.

  • SOLD SEPARATELY
Installing Quartz Element

1.

  1. OPEN ELEMENT LOCK BRACKET
  2. Loosen screw to open Lock Bracket

| 2.

INSERT ELEMENTS INTO SUPPORT BRACKET

  1. Open Lock Bracket to insert Quartz Element (x2)

---|---
3.

CLOSE ELEMENT LOCK BRACKET

  1. Tighten screw once closed to secure the 2 Quartz Element

4. TIGHTEN OUTER HEX NUT, LOCK WASHER AND LEAD WIRE RING TERMINAL TO THE THREADED STUD
Eurofase HEATING EF40 Urban Fireplaces - e4

  1. Quartz Element
  2. Threaded Stud
  3. Lead Wire Ring Terminal
  4. Lock Washer
  5. Outer Hex Nut

5. COMPLETE

  1. Lead Wire Ring Terminal, Lock Washer & Outer Hex Nut tightened to the Threaded Stud of the Quartz Element

Do not handle the Quartz Heating Element with bare hands. If it is inadvertently touched, remove finger marks with a soft cloth and methylated spirit or rubbing alcohol. Otherwise, the marks will burn into the quartz emitter during use causing premature heater failure.

Maintenance Instructions

Before cleaning, make sure the power has been turned off at the circuit breaker panel and that the heating element of the heater is cool. Never immerse the appliance in water or any other liquid. Cleaning and maintenance must be performed by the user and not by unsupervised children.

  1. It is important that these heating units are regularly cleaned to ensure long and efficient operating life.
  2. To clean, use a soft damp cloth and then dry thoroughly.
  3. Make sure all parts are dry before powering the heater.
  4. These heating units should be cleaned and inspected every three months.
  5. Avoid the use of harsh detergents, solvents, and abrasive or aerosol cleaners as they may damage surfaces.
  6. When cleaning the heater, always inspect the back of the heater for build-up of insects, bird droppings, dust, salt build-up, etc. and clean back thoroughly.
Technical Service

Always disconnect the appliance before doing any maintenance operation.

  1. If the heater is removed from mounting brackets, it should be stored in an undercover dry location.
  2. Always inspect the heater after high winds, earthquake, vandalism or any other unusual event that may have affected the heater. Ensure all parts are dry before powering the heater.
  3. Any maintenance service, excluding cleaning, must be carried out by an authorized manufacturer representative.
  4. If you have any question about your appliance, call the local authorized distributor.
Replacement Parts

Item #

| Description| Volts| Watts| Length (in)| Fits
---|---|---|---|---|---
EF20208E| 208V 2000W Quartz Element| 208| 2000| 39|

EF40, EF50

EF20240E

| 240V 2000W Quartz Element| 240| 2000| 39| EF40, EF50
EF20277E| 277V 2000W Quartz Element| 277| 2000| 39|

EF40, EF50

EF20480E

| 480V 2000W Quartz Element| 480| 2000| 39| EF40, EF50
EF25208E| 208V 2500W Quartz Element| 208| 2500| 39|

EF40, EF50

EF25240E

| 240V 2500W Quartz Element| 240| 2500| 39| EF40, EF50
EF25277E| 277V 2500W Quartz Element| 277| 2500| 39|

EF40, EF50

EF25480E

| 480V 2500W Quartz Element| 480| 2500| 39| EF40, EF50
EF30208E| 208V 3000W Quartz Element| 208| 3000| 61|

EF60

EF30240E

| 240V 3000W Quartz Element| 240| 3000| 61| EF60
EF30277E| 277V 3000W Quartz Element| 277| 3000| 61|

EF60

EF30480E

| 480V 3000W Quartz Element| 480| 3000| 61|

EF60

Item #

| Description| Qty| Fits
---|---|---|---
EFDEEF2| Dual Element End Reflector| 2|

EF40, EF50, EF60

EF39BOD

| Body Reflector – 39”| 1| EF40, EF50
EF61BOD| Body Reflector – 61”| 1|

EF60

EF39LWR

| Lead Wire Set – 39”| 1| EF40, EF50
EF61LWR| Lead Wire Set – 61”| 1|

EF60

EFMBSS2

| Mounting Bracket, Stainless Steel| 2| EF40, EF50, EF60
EFMBBL2| Mounting Bracket, Black| 2|

EF40, EF50, EF60

EFMBWH2

| Mounting Bracket, White| 2| EF40, EF50, EF60
EF39GGRD| Grill Guard, 39”, Stainless Steel| 1|

EF40, EF50

EF61GGRD

| Grill Guard, 61”, Stainless Steel| 1|

EF60

Please check the markings on the element for proper wattage and voltage

Need help? To order replacement elements for your Eurofase Heating Heating System, please contact us via phone or visit our website.

General Notes
  • Eurofase Heating Heaters are furnished with wall/ceiling mount swivel brackets. If the heater is hung with chains, special bracketing, or installing with a frame, these brackets can be discarded.

  • For pricing and a full list of models with descriptions and voltages, please see product brochures.

  • Wiring our Duplex/Stack Switches with our Dual Element Heaters gives users the ability to operate each element independently, providing half power and full power capabilities.

  • For optimal comfort, it is best to heat from two sides rather than from just one.
    However, this may not be practical in some cases.

  • Coverage areas vary in size, depending on personal comfort level and weather conditions.

  • The performance of heaters in extreme cold/windy environments may be reduced.

Manufacturer Warranty

Our heater is designed to provide you and your family with great outdoor experiences for years to come. To register, please fill in the Model and Serial number as well as the date of purchase in the areas below. For future reference, please save this information. Your electric heater’s owner’s manual should be carefully read before use. Please make sure that all family members are aware of the proper way to operate the heater and how to prevent serious injury.

Eurofase Heating warrants that this electric heater is designed and manufactured to be free from defects in materials and workmanship for a period of three years from the original date of purchase.

THREE YEAR LIMITED WARRANTY

THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY in accordance with the warranty terms and conditions specified below.

Eurofase Heating (warrantor) will furnish the original owner replacement parts for any component part which fails before three years of use from date of original purchase. At our option, Eurofase Heating may offer to rebuild or replace the heater within the limited warranty period. Installation, use and maintenance must be in accordance with instructions contained in the Installation Instructions.

THE WARRANTY DOES NOT COVER:
  • Service and labor costs incurred for diagnosing, removing or reinstallation of the heater(s) or parts(s) thereof.
  • Shipping and delivery charges.
  • Damage or repairs due to faulty installation, misapplication, negligence, thermal shock, earthquake, flood, fire, and purposeful damage to the heater.
  • Failure to operate due to electrical service issues including voltage conditions, blown fuses or circuit breakers.
  • Damage due to the inadequacy or interruption of electrical service.
  • Normal product wear (oxidation, scratches, heating element replacement, etc.)
GENERAL CONDITIONS PERTAINING TO WARRANTY

The warranty shall be null and void if the heater is not installed by a licensed heating contractor and/or licensed electrician or if the heater is not installed according to the Installation Instructions, normal industry practices and/or if the heater is not maintained and repaired according to the instructions.

Written permission is required for the return of any parts or equipment and any such return must be made on the basis of transportation charges prepaid. Shipment may be refused unless prior written permission is obtained and good returned prepaid.

LIMITATION ON IMPLIED WARRANTIES

Implied warranties, including any warranty of merchantability imposed on the sale of this heater under provincial or State law are limited to three year duration. Some states do not allow limitations on how long an implied warranty lasts.

CLAIMS PROCEDURE

Any claim under this warranty should be initiated with the dealer who sold the heater, or with any dealer handling the warrantor’s products. If this is not practical, the owner of the heater should contact Eurofase Heating toll free at 1-800-660-5390 (hours of operation 8-5 MF) or via email [email protected].

Eurofase HEATING EF40 Urban Fireplaces - f1


EUROFASE HEATING WARRANTY REGISTRATION

Customer Name: _____

Address: ____

City: __ State/Province:  Zip/Postal Code: ____

Country: __ Phone:  Email: ____

Model #: ____ Serial No.#: __

Dealer’s Name: __ Date Purchased: ____

Dealer’s Address: __

This Warranty Registration Card must be returned within 30 days of purchase to properly activate your warranty.
This information is for our internal use only.

Eurofase HEATING logo

33 West Beaver Creek Road, Richmond Hill, ON L4B 1L8 Canada
Tel: 1.800.660.5391 | Email: [email protected] | EurofaseHeating.com

Eurofase HEATING EF40 Urban Fireplaces - f2 NEED MORE INFORMATION?

If you have further questions please contact us at:
[email protected]
1-800-660-5391

Eurofase HEATING logo

EurofaseHeating.com

Eurofase HEATING EF40 Urban Fireplaces - f1

Eurofase HEATING logo

EurofaseHeating.com

33 West Beaver Creek Road,
Richmond Hill, ON
L4B 1L8
Canada

Eurofase HEATING EF40 Urban Fireplaces - f2

Eurofase HEATING logo

[email protected]
1-800-660-5391

Eurofase logo

T. 905.695.2055        33 West Beaver Creek,
F. 905.695.2056        Richmond Hill, ON L4B 1L8

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Eurofase HEATING User Manuals

Related Manuals