KSANA A03841 Gold Chandeliers for Dining Room Instruction Manual
- June 17, 2024
- KSANA
Table of Contents
- KSANA A03841 Gold Chandeliers for Dining Room Instruction Manual
- WARNING (To reduce the risk of fire, electric shock, or injury to
- IMAGE FOR FINISHED PRODUCT:
- TOOLS REQUIRED (NOT INCLUDED):
- PARTS TYPE & QTY INCLUDING:
- ASSEMBLY & INSTALLATION INSTRUCTIONS:
- 3. Turn off power
- 4. Make installation
- Connect ground wire according to below chart
- Connect wires according to below chart
- 5. Check everything are already installed properly, then you could turn
- CLEANING.
- ORDERING PARTS.
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KSANA A03841 Gold Chandeliers for Dining Room Instruction Manual
WARNING (To reduce the risk of fire, electric shock, or injury to
persons):
- We suggest installation by a licensed electrician.
- Please read the instruction carefully and save it as you may need it at later time.
- Before you start, NEVER attempt any work without shutting off the electricity until the work is done. A). Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position. B). Place the wall switch in the “OFF” position.
- Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all side. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
- Make sure that the ceiling or wall can stand the weight of the lamp before fixture.
- Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.
- Keep the lamp away from acidic and basic objects in case of damaging the surface of the lamp.
- When replacing bulb, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
- The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:
TOOLS REQUIRED (NOT INCLUDED):
Before doing assembly and installation please prepare the needed tools as below picture
PARTS TYPE & QTY INCLUDING:
(C) Single bar (1) P
(D) Green ground screw (1) A
(E) Canopy (1) C
(F) Collar ring (1) B 18— D
(G) Collar loop (1)
(H) Quick link (8)
(I) Chain (1)
(J) Loop (1)
(K) Upper fixture loop assembly (1)
(L) Stem (1)
(M) Tube (3)
(N) Upper iron frame (1)
(O) Screw (24)
(P) Plastic washers (24)
(Q) Glass (6)
(R) Lower fixture loop assembly (1)
(S) Lower iron frame (1)
ACCESSORIES & QTY ENCLOSED:
(A) Wire connector (3)
(B) Mounting screw (2)
(P) Plastic washers (2) spare parts
ASSEMBLY & INSTALLATION INSTRUCTIONS:
- Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in theabove illustration.
- Make pre-installation
Step Al: Connect the upper iron frame (N) and lower iron frame (S) together
with a glsss(Q) and secure with screws (O).
Step A2: Slip stem (L) over the wires and then thread it into the top of
fixture body (R). Slip fixture loop (K) over wires and then thread it onto the
top of stem (L).
Step A3: Connect the fixture loop assembly (K) and upper iron frame (N) with a
quick link (H).
3. Turn off power
Before you start to make installation, NEVER attempt any work without shutting
off the electricity until the work done.
A). Go to the main fuse, or circuit breaker, box in your home. Place the main
power switch in the “OFF” position. B). Place the wall switch in the“OFF”
position.
4. Make installation
Step C1: .Attach the single bar (E) to outlet box with mounting screws (B).
The side of single bar marked “GND” must face out
Step C2: Raise the canopy (G) through screw collar loop (1) and screw the
collar loop (1) to a proper position by measuring.
Unscrew threaded ring (H) from screw collar loop (1) and remove the canopy
(G). In this way, you would know the
Proper position on which collar loop it should be located.
Note: The canopy (G) should be snug against the ceiling and the collar loop
(1) should be screwed enough threads (no less than 6 threads )over the
threaded nipple (C) for more secure hanging .If not, adjust the collar
loop (H)on the single bar assembly by screwing the collar loop (1) in or out
of the single bar (E) until the length is achieved.
Step C3: Slip the threaded ring(H) over the chain(K),then do the same with the
canopy(G)
Step C4: Open the quick link(J), attach the quick link (J) to connect the loop
(1). Close the quick link(J). Pass the wires through screw collar loop(H) to
the top of nipple(E) and gently pull till snug.
Step C5: If needed, cut off the wires length of fixture.At this point, the
remaining wire length measured from the top of single bar(B) is at least 6″.
Step c6: Make wire connections
Connect wires as below wires connecting shown. TAKE NOTE OF YOUR COLOR OF
FIXTURE ,NEVER CONNECT
WIRES TO GROUND WIRES
Connect ground wire according to below chart
Connect wires according to below chart
Twist plastic wire connector until wires are tightly joined together,wrap each
connector with approved electrical tape.Be sure that no wire strands are
exposed and then carefully tuck all wires into the outlet box .
Step B7: Raise canopy (E) to ceiling and secure canopy (E) in place by
tightening threaded ring (F) onto collar loop (G).
Step B8: Install the bulb (not included) (Please do not exceedthe maximum
capacity recommended on the socket.)
5. Check everything are already installed properly, then you could turn
on the light. Enjoy!
CLEANING.
To clean, wipe fixture with a soft cloth. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.
ORDERING PARTS.
Keep this sheet for future reference, and in case you need to order replacement parts. All parts for this fixture can be ordered from place of purchase. Be sure to use exact wording from illustration when ordering parts.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>