MEAN WELL LPP-150 series Single Output with PFC Function User Guide

June 17, 2024
MEAN WELL

150W Single Output with PFC Function
LPP-150 series

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTlN.aspx

Features:

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.96
  • Protections: Short circuit / Overload / Over voltage
  • Protections:Over temperature(option)
  • Cooling by free air convection
  • 100% full load burn-in test
  • Fixed switching frequency at PFC:67KHz  PWM:134KHz
  • 3 years warranty

https://www.meanwell.com/Upload/PDF/PCB_EN.pdf

SPECIFICATION

MODEL| LPP-150-3.3| LPP-150-5| LPP-150-7.5| LPP-150-12| LPP-150-13.5| LPP-150-15| LPP-150-24| LPP-150-27| LPP-150-48
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 7.5V| 12V| 13.5V| 15V| 24V| 27V| 48V
RATED CURRENT| 30A| 30A| 20A| 12.5A| 11.2A| 10A| 6.3A| 5.6A| 3.2A
CURRENT RANGE| 0 ~ 30A| 0 ~ 30A| 0 ~ 20A| 0 ~ 12.5A| 0 ~ 11.2A| 0 ~ 10A| 0 ~ 6.3A| 0 ~ 5.6A| 0 ~ 3.2A
RATED POWER| 99W| 150W| 150W| 150W| 151.2W| 150W| 151.2W| 151.2W| 153.6W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| 3.14 ~ 3.63V| 4.75 ~ 5.5V| 7.13 ~ 8.25V| 11.4 ~ 13.2V| 12.8 ~ 14.9V| 14.3 ~ 16.5V| 22.8 ~ 26.4V| 25.7 ~ 29.7V| 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 600ms, 30ms at full load
HOLD UP TIME (Typ.)| 30ms at full load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC        120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.96/230VAC         PF≧0.97/115VAC at full load
EFFICIENCY(Typ.)| 70%| 76%| 80%| 82%| 83%| 83%| 85%| 85%| 85%
AC CURRENT (Typ.)| 2.5A/115VAC       1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 55A/230VAC
LEAKAGE CURRENT| <3.5mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.63 ~ 4.45V| 5.5 ~ 6.75V| 8.25 ~ 10.1V| 13.2 ~ 16.2V| 14.85 ~ 18.2V| 16.5~ 20.25V| 26.4 ~ 32.4V| 29.7 ~ 36.5V| 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -10 ~ +60℃ with cooling FAN (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & **EMC
(Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2635.3K hrs min.     Telcordia SR-332 (Bellcore) ; 292.7K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 2227541mm (LWH)
PACKING| 0.62Kg; 24pcs/16.6Kg/1.63CUFT
NOTE*| 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.  Tolerance : includes set up tolerance, line regulation and load regulation.
4.  The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm
360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com)
5.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL LPP-150 series Single Output with PFC Function - Mechanical
SpecificationAC Input Connector (CN1) : JST B5P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2,4 No Pin
3 AC/N
5 FG ****

DC Output Connector (CN2) : JST B6P-VH*2 or equivalent

Pin No. Assignment Mating Housing Terminal
1~6 -V JST VHR  or equivalent JST SVH-21T-P1.1 or equivalent
7~12 +V

****: Grounding Required
CN1: Pin 5 is safety ground

Block Diagram

MEAN WELL LPP-150 series Single Output with PFC Function - Block
Diagram

Derating Curve

MEAN WELL LPP-150 series Single Output with PFC Function - Derating
Curve

Output Derating VS Input Voltage

MEAN WELL LPP-150 series Single Output with PFC Function - Output Derating
VS Input Voltage

File Name: LPP-150-SPEC 2022-09-20MEAN WELL LPP-150 series Single
Output with PFC Function - Icon 1

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals