MEAN WELL LPP-150 series Single Output with PFC Function User Guide
- June 17, 2024
- MEAN WELL
Table of Contents
150W Single Output with PFC Function
LPP-150 series
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
Features:
- Universal AC input / Full range
- Built-in active PFC function, PF>0.96
- Protections: Short circuit / Overload / Over voltage
- Protections:Over temperature(option)
- Cooling by free air convection
- 100% full load burn-in test
- Fixed switching frequency at PFC:67KHz PWM:134KHz
- 3 years warranty
https://www.meanwell.com/Upload/PDF/PCB_EN.pdf
SPECIFICATION
MODEL| LPP-150-3.3| LPP-150-5| LPP-150-7.5|
LPP-150-12| LPP-150-13.5| LPP-150-15| LPP-150-24|
LPP-150-27| LPP-150-48
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 7.5V| 12V| 13.5V| 15V| 24V| 27V| 48V
RATED CURRENT| 30A| 30A| 20A| 12.5A| 11.2A| 10A| 6.3A| 5.6A| 3.2A
CURRENT RANGE| 0 ~ 30A| 0 ~ 30A| 0 ~ 20A| 0 ~ 12.5A| 0 ~ 11.2A| 0 ~ 10A|
0 ~ 6.3A| 0 ~ 5.6A| 0 ~ 3.2A
RATED POWER| 99W| 150W| 150W| 150W| 151.2W| 150W| 151.2W| 151.2W| 153.6W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 100mVp-p|
100mVp-p| 100mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| 3.14 ~ 3.63V| 4.75 ~ 5.5V| 7.13 ~ 8.25V| 11.4 ~
13.2V| 12.8 ~ 14.9V| 14.3 ~ 16.5V| 22.8 ~ 26.4V| 25.7 ~ 29.7V| 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%|
±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%|
±0.5%
SETUP, RISE TIME| 600ms, 30ms at full load
HOLD UP TIME (Typ.)| 30ms at full load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.96/230VAC PF≧0.97/115VAC at full load
EFFICIENCY(Typ.)| 70%| 76%| 80%| 82%| 83%| 83%| 85%| 85%| 85%
AC CURRENT (Typ.)| 2.5A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 55A/230VAC
LEAKAGE CURRENT| <3.5mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 3.63 ~ 4.45V| 5.5 ~ 6.75V| 8.25 ~ 10.1V| 13.2 ~ 16.2V|
14.85 ~ 18.2V| 16.5~ 20.25V| 26.4 ~ 32.4V| 29.7 ~ 36.5V| 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -10 ~ +60℃ with cooling FAN (Refer to
“Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & **EMC
(Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC
TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 2635.3K hrs min. Telcordia SR-332 (Bellcore) ;
292.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 2227541mm (LWH)
PACKING| 0.62Kg; 24pcs/16.6Kg/1.63CUFT
NOTE*| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. The power supply is considered a component which will be installed into a
final equipment. All the EMC tests are been executed by mounting the unit on a
360mm360mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to “EMl testing of component power supplies.”
(as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
AC Input Connector (CN1) : JST B5P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/L | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
2,4 | No Pin | ||
3 | AC/N | ||
5 | FG **** |
DC Output Connector (CN2) : JST B6P-VH*2 or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1~6 | -V | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
7~12 | +V |
****: Grounding Required
CN1: Pin 5 is safety ground
Block Diagram
Derating Curve
Output Derating VS Input Voltage
File Name: LPP-150-SPEC 2022-09-20
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>