IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING’
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

  • Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
  • Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do ot use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
  • Turn the unit OFF and unplug your air conditioner before cleaning.
  • For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
  • If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

WARNING Risk of Fire or Explosion. This unit contains flammable refrigerant.Additional safety precautions must be followed.

  • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
  • Do not pierce or burn refrigerant tubing. Be aware that refrigerants may not contain an odor.
  • Keep ventilation openings clear of obstruction.
  • When handling, installing, and operating the appliance, care should be taken to avoid damage to the refrigerant tubing.
  • Do not drill holes in the unit.
  • Maintenance, cleaning, and service should only be performed by technicians properly trained and qualified in the use of flammable refrigerants.
  • GE Appliances does not support any servicing of the air conditioner.
  • Dispose of air conditioner in accordance with Federal and Local Regulations. Flammable refrigerants require special disposal procedures. Contact your local authorities for the environmentally safe disposal of your air conditioner.

WARNING USE OF EXTENSION CORDS RISK OF FIRE. Could cause serious injury or death.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

Controls

Features and appearance will vary.
Lights beside the touch pads on the air conditioner control panel indicate the selected settings.

  1. Power Pad
    Turns air conditioner on and off. When turned on, the display will show the Set temperature.

  2. Display
    Shows the Set temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Eco modes.

  3. Temp and Delay Increase A IDecrease V Pads
    Use to set temperature or delay time. Temperature can be set in Cool and Eco mode.

  4. Mode Pad
    Use to set the air conditioner to Fan Only, Cool, or Eco mode.

  5. Fan Speed Pad
    In Cool or Eco mode: Use to set the fan speed to Auto,
    High, Med or Low on the unit. In Fan Only mode: Use to set the fan speed to High, Med, or Low on the unit.

  6. Delay Pad (set by remote control only)
    Delay ON-When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous\mode and fan settings.
    Delay OFF-When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.
    HOW to Set. Press the Delay pad on the remote control. Each touch of the Increase A / Decrease V pads on the remotecontrol will set the timer in 1-hour intervals.
    To review the remaining time on the Delay timer, press the Delay pad on the remote control. Use the Increase
    A/ Decrease v pads on the remote control to set a new time if desired.
    To cancel the timer, press Decrease v pad on theremote control until the set time is zero.

  7. Sleep Pad (set by air conditioner controls only) The SLEEP mode sets the unit to gradually change settings over an 8 hour period to allow for some increased energy efficiency during sleep hours. The SLEEP mode is available only in COOL and FAN only settings
    Press the SLEEP mode pad and its light will illuminate. The fan indicator will stay at the same setting but the air conditioner will automatically change the FAN speed tolow in either COOL or FAN only mode.
    In FAN only mode, the fan will stay in the LOW-speed setting for 8 hours. After 8 hours, the air conditioner will resume the settings that were in place before the SLEEP mode pad was pressed.
    In COOL mode, the fan will stay in the LOW-speed setting for 8 hours from the time the SLEEP mode pad  was pressed. The air conditioner will also raise the set point 2°F in 30 minutes and 2°F more in another 30  minutes where it will remain for the next 7 hours. After 8 hours, the air conditioner will resume the settings  that were in place before the SLEEP mode pad waspressed.
    While the unit is in SLEEP mode, pressing any pad will return it to the settings that were in place before theSLEEP mode pad was pressed.

  8. Filter Reset Pad
    This feature automatically notifies you that the air filter must be cleaned. The indicator light will come on after 250 hours of operation. Clean the air filter (refer to page 6), place it back in the front panel, and press the FilterReset pad. The light will go off.

  9. WiFi Connect Pad
    Enables connection of the air conditioner to the home WiFi. Download App for details at: www.GEAppliances.com/connect.

Using the Air Conditioner

Do Not Operate in Freezing Outdoor Conditions

This cool-only air conditioner was not designed for freezing outdoor conditions.
It must not be used when the outdoor temperature is below freezing (32°F)

Control Panel Lights On/Off Feature
This air conditioner has a control panel lights on/off feature where its lights will turn off when there is no activity with the controls for over one minute. To wake up the controls, press any pad on the controls and thelights will come on to show the previous settings.

To turn this feature off, press and hold the SLEEP pad, on the unit, for 5 seconds. The unit will beep to signal the successful toggle of the feature on and off.

Remote Control

  • To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.
  • The remote control signal has a range of up to 20 feet.
  • Make sure nothing is between the air conditioner and the remote control that could block the signal.
  • Make sure batteries are fresh and installed correctly as indicated on the remote control

Cool Mode

Use the Cool mode at Low, Med, High or Speed for cooling. Use the Temperature Increase A/ Decrease Vpads to set the desired temperature between 64°F and86°F in 1°F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions For Normal Cooling—Select the Cool mode andHigh or Med fan with a middle set temperature. For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature. For Quieter and Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.

Eco Mode

Controls the fan.
ON—The fan will cycle on and off with the compressor. This may result in wider variations of room temperature and humidity. NOTE: the fan may continue to run for a short time or may pulse intermittently after the compressor cycles off to sample the room air.

OFF—The fan runs all the time, while the compressor cycles on and off.

Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

Auto Fan Mode
Set to Auto for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.

Using the Air Conditioner

Air Direction
Use the levers to adjust the air direction left or right.
Tilt the louver bank to adjust up and down.

Care and Cleaning

Grille and Case
Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use bleach or abrasives.

Air Filter
The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

To remove:
Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

Outdoor Coils
The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

How to Insert the Batteries in the Remote Control

  1. Remove the battery cover by sliding it according to the NOTES: arrow direction.
  2. Insert new batteries, making sure that the (+) and of battery are installed correctly.
  3. Reattach the cover by sliding it back into position.

NOTE:

  • Use 2 “AAA” (1.5 volt) batteries. Do not use rechargeable batteries.
  • Remove the batteries from the remote control if the system is not going to be used for a long time.
  • Do not mix old and new batteries. Do not mix standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) batteries.

Installation Instructions

Questions? Visit our Website at: GEAppliances.com

BEFORE YOU BEGIN

  • Read these instructions completely and carefully.
  • IMPORTANT – Save these instructions for local inspector’s use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
  • Completion time – Approximately 1 hour
  • We recommend that two people install this product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.
  • You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

ELECTRICAL REQUIREMENTS

These models require a 115/120-volt AC, 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

CAUTION

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems—consult a qualified electrician

Power cord includes a current interrupter device. A test and reset button is provided on the plug case.  The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

TOOLS YOU WILL NEED

PARTS INCLUDED
  1. . WINDOW REQUIREMENTS

    • These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
    • The air conditioner can be installed without the side curtain panels if needed to fit in a narrow\ window. See the window opening dimensions.
    • All supporting parts must be secured to firm wood, masonry or metal.
    • The electrical outlet must be within reach of the power cord.
    • Follow the dimensions in the table andillustration for your model.
      Models| A| B
      ---|---|---
      AHC08| 13 3/8´ PLQ| 24 1/2´-36´
      AHC10/AHC12| 14 9/16´ PLQ| 25´ – 36 5/8´
      AHC14| 15 5/8´| 26 1/8´ – 37 3/4´
  2. STORM WINDOW REQUIREMENTS
    A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.
    WOOD PIECES
    WIDTH: 2″
    LENGTH: Long enough to fit inside the window frame.
    THICKNESS: To determine the thickness, place a piece of wood on the sill to make it 1/2″ higher than the top of the storm window frame or the Vinyl frame.
    Attach securely with nails or screws provided by the installer.

  3. PREPARE THE AIR CONDITIONER

    • A. Install the top mounting rail with 4 Type A screws (AHC10 / AHC12) or 3 Type A screws (AHC08) from the outside of the case.
    • B. Apply the weather seals provided to the bottom, top and sides of the window to the seal around the perimeter of the air conditioner.
    • C. Slide the side curtain panels into the side panel rails
    • D. Slide left and right side curtain frames into top and bottom rails. Make sure that side curtains snap into side of the frames.
  4. INSTALL THE AIR CONDITIONER IN THE WINDOW

    • A. Mark the center of the window. Set the air onditioner in the window so that is it centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.
    • B. Bring the window down so that the front edge of the top mounting is in front of the window. Make sure that the air conditioner is level or tilting slightly to the outside.
    • C. Extend the curtain panels until they fill the window. Mark the location of the holes in each comer. Use the drill and 1/8″ drill bit to drill pilot holes. Use 4 type B screws to secure the side panels in place
  5. SECURE AIR CONDITIONER

    • A. Loosen the screw on the right hand side of the air conditioner near the bottom.
    • B. Slide a side bracket over the screw so that the bracket is resting on the window sill. Tighten the screw.
    • C. Use a 1/8″ drill bit to drill a starter hole into the window sill through the holes in the side bracket. Use 4 type B screws to attach the side bracket to the window sill.
    • D. Repeat the side bracket installation on the left side.
    • E. Measure and cut adhesive foam-backed sheet. Apply over side curtain and frame.
  6. INSTALL WINDOW LOCK BRACKET AND FOAM TOP WINDOW GASKET
     Use Type B Screw to install the window lock bracket on top of the bottom window.
    CAUTION

    • A. To prevent broken glass or damage to windows,  on vinyl or other similarly  constructed windows,  attach the window locking bracket to the window side jamb with one Type B Screw.
    • B. Cut the foam top window gasket to the window width.
    • C. Stuff the foam between the glass and the window to prevent air and insects from getting into the room. NOTE: If the gasket supplied does not fit your window, obtain appropriate material locally to provide a proper installation seal.

Troubleshooting

Troubleshooting Tips… Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.

Problem Possible Cause What To Do
Air conditioner does not start. The unit is unplugged. Make sure

the air conditioner plug is pushed completely into the outlet.
7KH IXVH LV EORZQ/FLUFXLW EUHDNHU

is tripped.

| Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
Power Failure.| The unit will automatically restart in the setting last used after the power is restored.

There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor

overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.

The current interrupter device is tripped.| Press RESET button located on the power cord plug.

If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Air conditioner does not cool as it should.| Indoor airflow is restricted.| Make sure there are not curtains, blinds or furniture blocking the front of the air conditioner.
The temp control may not be set properly.| Turn the temperature control to a higher number.
The air filter is dirty.| Clean the filter at least every 30 days. See Care and Cleaning section.
The room may have been hot.| When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping.| Check for open furnace registers and cold air returns.
Cooling coils have iced up.| See “Air conditioner freezing up” below.
Air conditioner freezing up| Ice blocks the air flow and stops the air conditioner from cooling the room.| Set the mode control to High Fan or High Cool with the temperature setting as high as it can be set.
Water drips outside| Hot, humid weather.| This is normal.
Water drips inside| The air conditioner is not tilted to the outside.| For proper disposal, make sure the air conditioner slants slightly from the case front to the rear.
Water collects in base pan| Moisture removed from air and drain into base pan.| This is normal for a short period in areas with little humidity; normal for a longer period in very humid areas.

Normal Operating Sounds

  • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy dayS or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and off.
  • Water will collect in the base pan duringhigh humidity or on rainy days. The water may overfiow and drip from the Outdoor side of the unit.
  • The fan may run even when the compressor does not.
  • Water droplets being thrown against the outside coils can make a pinging noise. This helps cool the condenser. You can reduce this noise by removing the subbase water plua. To ensure maximum efficiency it is recommended to check to ensure the rubber drain plug is properly inserted.
    This plug may be removed during operation to minimize water in the back of the unit; however, removing it will lower the efficiency of your unit.
    NOTE: Do not drill hole in the base pan.

WiFi Setup

GE Appliances WiFi Connect (for customers in the United States)
GE Appliances WiFi Connect Enabled”. If your Air Conditioner (AC) has a Connected Appliance Information label located on the outside as shown below, your AC is GE Appliances WiFi Connect Enabled. A WIFi communication card is built into the product allowing it to communicate with your smart phone for remote monitoring, control and notifications. Please visit www.GEAppliances.com/connect to lean more about connected appliancefeatures, and to learn what connected appliance apps will work with your smart phone.

How it Works

  • Download the GE Appliances App
  • Use the app to connect your room air
  • Once connected, use the app to turn conditioner to WiFi down your air conditioner as you leave work.

Getting Started

To connect your room air conditioner, you’ll need the GE Appliances App. The app will walk you through the connection process. Download the app from iTunes or Google Play.

All connected appliace data is held in strict accordance with the GE Appliances Connected Data Privacy Policy. Visit geappliances.com/privacy /privacy_policy-connected to view this policy.

Questions about WiFi Connect
Get answers you need about setting up WiFi appliances and connecting to your home network in our support articles.
Visit products.geappliances.com/appliance/gea-support-search- content to view wifi connect room air Conditioner support articles.

REGULATORY INFORMATION

FCC/IC Compliance Statement:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radiofrequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/television ctechnician for help

Labelling: Changes or modifications to this unit not expressly approved by the manufacturer could void the user’s authority to operate the equipment

This product has Wi-Fi capability and requires Internet connectivity and a wireless router to enable interconnection with an Energy Management System, and/or with other external devices, systems or applications.

Use of the Works with Apple HomeKit TM logo means that an electronic accessory has been designed to connect specifically to iPod touch®, iPhone®, or iPad®, respectively, and has been certified by the developer to meet Apple® performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards.

Appliances Air Conditioner Limited Warranty

For The Period Of: Will Replace:

One Year

From the date of the original purchase

| Replacement, repair, or refund of the original retail price for any product which fails  due to a defect in materials or workmanship. If the unit is exchanged, the replacement unit is warranted for the remainder of your product’s original one-year warranty period. GE Appliances will, at its sole discretion, replace the product with a product of the same or comparable functionality and quality or refund the original retail price.

In Order to Make a Warranty Claim During Your Retailer’s Allowable Return Period:

Properly pack your unit. We recommend using the original carton and packing materials.
Include in the package a copy of the sales receipt or other evidence of date of original purchase. Also print your name and address and a description of the defect
Return the product to the retail location where it was purchased..

In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:

  • Locate your original sales receipt and make a note of your model and serial number.
  • Please return all requested materials (postage pre-paid in the carton provided. Please include a description of the defect.
  • Call 866-907-1655 to initiate the product replacement process.
  • You will be asked to provide your name, address, date of purchase, model and serial number.
  • You should receive your replacement product or refund within 7 to 10 business days after your package is received.
  • GE Appliances will arrange for a carton to be sent to your home to recover the product.

What Will Not Cover:

  • Replacement of house fuses or resetting of circuit breakers.
  • Customer instruction. This owner’s manual provides information regarding operating instructions and user controls.
  • Failure due to corrosion on models not corrosion-protected.
  • Improper installation. If you have an installation problem, or if the air conditioner is of improper capacity, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
  • Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
  • Incidental or consequential damage caused by possible defects with this air conditioner.
  • Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
  • Damage caused after delivery.

EXCLUSION OF IMPLIED WARRANTIES – Your sole and exclusive remedy is product repair as provided in this
Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a
particular purpose, are limited to one year or the shortest period allowed by law.

This limited warranty is extended to the original purchaser and any succeeding owner for products purchased
for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized
Servicer is not available, you may be responsible fora trip charge or you may be required to bring the product to an Authorized GE Appliances Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor:
GE Appliances, a Haier company
Louisville, KY 40225

Consumer Support

Appliances Website

Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support services designed for your convenience. GEAppliances.com

Register Your Appliance

Register your new appliance on-line at your convenience! Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty, should the need arise. You may also mail in the pre-printed registration card included in the packing material. GEAppliances.com/register

Parts and Accessories

Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes (VISA, MasterCard and Discover cards are accepted). Order on-line today 24 hours every day. GEApplianceparts.com or by phone at 877.959.8688 during normal business hours.

Instructions contained in this manual cover procedures to be performed by any user. Other servicing generally should be referred to qualified service personnel. Caution must be exercised, since improper servicing may cause unsafe operation.