MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray Installation Guide

June 17, 2024
Mondawe

MONDAWE logo Digital Display Thermostatic Shower
Installation guide
G-4.2 (YF)

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld
Spray Model: A 6369

Installation Condition

  1. Check the accessories list to verify that all parts are complete in this package.
  2. Do not disassemble the main body by yourself.
  3. Connect inlet pipes to supply valves.
  4. Make sure inlet pipes and supply valves have no impurities and are cleaned, with no impurities in the pipeline.
  5. After installation, check all joints for leakages.
  6. Do not leave the rain shower system exposed to a severely corrosive environment.

YOU MAY NEED:

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Need

• 4 Functions Luxury Thermostatic Shower Faucet

Model: A
Accessories ListMONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet
and Handheld Spray - Accessorices List

No.| Part name| Qty| No.| Part name| Qty| No.| Part name| Qty
---|---|---|---|---|---|---|---|---
1| Expansion screws| 4| 10| Shower head body| 1| 19| Water diverter rod| 4
2| lnwall box| 1| 11| Hand shower holder| 1| 20| Water diverter| 4
3| Water inlet| 3| 12| Holder cup| 1| 21| Handle| 1
4| Cover| 1| 13| Hand shower| 1| 22| Main body spare parts| 10
5| Screw| 2| 14| Shower hose| 1| 23| Instruction manual| 1
6| S8 Allen key| 1| 15| Body jet cover| 3| 24| Gloves| 2
7| Flange| 1| 16| Body jet| 3| 25| Handle parts| 1set
8| Allen key 2.5| 1| 17| Main body| 1| | |
9| M4 screw| 2| 18| Deck plate| 1| | |

Essential dimensions & water pipe line

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Pipe Line

The installation depth of shower holder and body jet

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Holder body jet

The thickness of the tile must be calculated for installation.
Connector size of male thread: USA: 1/2″-14NPT, Canada: 1/2″-14NPT, Europe: G1/2″.

Installation Depth Of Main Body

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Main body

Notice:

  1. The installation depth of the main body should be no less than 3 1/8″ (80mm) and no more than 3 3/4″ (95mm), including the thickness of the tile. Otherwise, the deck plate cannot be installed.
  2. The opening size of ceramic tile shall be smaller than the deck plate size.

Piping Instructions Before Tiling

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Tiling

  1. As shown in the figure, the inlet and outlet pipes are pre-buried. Please pay attention to the correct direction when installing the pre-buried main body.
  2. Before tiling, turn on the water to test whether the left and right inlet pipes are tightly connected without leakage. Then, adjust the flow switch to the “on” position to check for leaks in the mixed outlet pipes.

Main Body Valve Installation

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Main body Valve 1

Step 1

  1. Make marks according to the size of the main body valve, and then drill anchors into the wall (concrete wall).
  2. Lock the main body to wood directly with screws (wood wall).
  3. When installing the main body, please mark the UP side up and do not install it upside down.

▲ Please note that the level meter should be parallel to the wall; otherwise, the deck plate cannot be installed.

Step 2MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld
Spray - Main body Valve 2

Do not remove the white wear ring; otherwise, the handwheel will be damaged.
Water flow control:clockwise Turn-down and stop ,anti-clockwise Turn-up to max

Precautions for Handwheel Installation
※ 1. The line can’t be misplaced; it should be keptin line. Otherwise, the water temperature of 100°F or 38°C will not be correct. ※ 2. Please ensure that the plastic locating ring (A) and handwheel locating pin (B) are kept in the same line with 100°F or 38°C. Otherwise, the water temperature will be incorrect.MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld
Spray - Line 2

  1. Please install the deck plate, water diverters, and water diverter rods step by step.
  2. Install the handle with the screw and handle cap.

Body Jets Installation

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Body Jets

Step 1. Wrap the threaded pipe of NPT1/2 with Teflon tape and screw it into the wall.
Step 2. Cut off any excess parts using a saw.
Step 3. Screw the massage body jet onto the wall.

The opening size of the ceramic tile should be smaller than the decorative cup of the body jet size; otherwise, it will not be installable.

Installation The Hand Show HolderMONDAWE G-4.2YF Luxury Rain Shower
System with 3 Jet and Handheld Spray - Hand Show Holder

Step 1. Screw the thread into the water pipe inside the wall
Step 2. Screw the main body into the thread.
Step 3. Rotate and fix the body with the special-shaped wrench
Step 4. Connect the hand shower and the hose.

22In Shower Head Installation

  1. Digging wall according to following size,and connect rain and waterfall inlet correctlyMONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray - Figure 1 If the Inwall box is embedded too deep, the sho head will not be installed properly and it will cause water leakage and sag problems. Please attention to the installation depth.

  2. Lock Inwall box refer to level meter guarantee horizontal level and test leakingfor 24 hours.MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray - Figure 2

  3. Remain inwall box in same level as wall after seal the tile and cover exceed wall.

  4. Install Shower head body. First remove box cover and plug, screw three water inletsinto inwall box with S8 Allen Key.Longes role is support.MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray - Figure 4

  5. Install Flange as picture.
    Caution: do setp 4-5-6 to test horizontaland vertical position of shower head before wall seal to avoid any troubleof repair after wall seal.MONDAWE
G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray - Figure
5

  6. Push shower head body into according water inlets, and tighten shower bodyby M4 screw with Allen key 2.5.MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray - Figure 6

Do’s

  1. In order to keep the mixer surface bright, please clean the mixer regularly.
  2. Rinse the faucet with clean water and wipe it with a soft cotton cloth.
  3. Use one of the following cleaners to remove dirt from the surface:
    a. Mild liquid cleaner.
    b. Colorless glass cleaner and powder cleaner that do not cause abrasion and can be dissolved completely.
    c. Polish liquid that does not cause abrasion.

MONDAWE G-4.2YF Luxury Rain Shower System with 3 Jet and Handheld Spray -
Figure 7

Don’ts
a. Avoid using cleaning powder, harsh cleaning chemicals, brushes and coarse cloth to prevent scratching and friction.
b. Do not use acid cleaners to clean the faucet as they may cause surface corrosion of the faucet. If the faucet is exposed to harmful acid substances, please rinse it immediately with water.

MONDAWE logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mondawe User Manuals

Related Manuals