Specifications:
- Model: FFLE/2 LED Flood Light
- Wattage Range: 15 to 300
- Color Temperature (CCT): Selectable
- Mounting Options: Knuckle Mount, Flood Mount, Trunnion Mount,
Slipfitter Mount
Product Usage Instructions
Wiring:
Before wiring the fixture, verify the input AC voltage. If not using the
dimming function, cap the 0/1-10V dimming wires. The wiring colors are as
follows:
- VIOLET (DIM +)
- PINK (DIM -)
- BLACK/BROWN (HOT)
- WHITE/BLUE (NEUTRAL)
- GREEN/YELLOW (GROUND)
Setting Wattage and Color:
For wattage and color selection, follow these steps based on the model:
- Models FFLE/2-015 to 100: Access dip switches by removing the metal knockout cap on the fixture’s rear. Adjust settings for wattage and color as needed.
- Models FFLE/2-120 to 300: Similar process as above for wattage and color selection.
Mounting Options:
Choose the appropriate mounting option based on your model:
- Knuckle Mount: Attach to conduit or junction box.
- Flood Mount: Attach to walls or ceilings.
- Trunnion Mount (Optional): Drill holes on the surface, insert bolts, and mount the fixture allowing for angle adjustment.
- Slipfitter Mount (Optional): Designed for mounting onto a tenon.
FAQ
Q: How can I adjust the wattage and color of the light?
A: To adjust the wattage and color, access the dip switches by removing the
metal knockout cap on the fixture’s rear and making the necessary adjustments.
Q: What do I do if I don’t want to use the dimming function?
A: Cap the 0/1-10V dimming wires if you choose not to utilize the dimming
function.
Q: How do I contact support for further assistance?
A: You can reach out to customer support at
800-988-6386 or email
CS@PacLights.com.
INSTALLATION GUIDE
IMPORTANT
SAFETY PRECAUTIONS
- Avoid testing this LED light with any electric generator.
- Ensure installation adheres to local, regional, and national laws and regulations.
- Always disconnect power before installation or maintenance.
- Proper grounding is essential for safety.
INSTALLATION NOTE
- Installation should only be performed by individuals with electrical expertise to prevent potential electrical shock or fire hazards.
- Wear gloves during the installation to prevent injuries.
- In case of any visible smoke or sparking from the wire, immediately disconnect the power and alert the appropriate personnel.
DIMMING FUNCTION
- This LED light is equipped with a dimming function.
- The light features three available dimming methods:0-10VDC or 1-10VDC constant current dimming. PWM signal dimming. Resistance-based dimming. (Choose the appropriate dimming method based on your requirements. You may also opt not to utilize the dimming function.)
- Make your selection based on wire connection preferences, desired dimming methods, and the specific LED fixture purchased.
WIRING
input AC voltage before connecting. Separate and cap the 0/1-10V dimming
wires if opt not to utilize the dimming function.
SELECT WATTAGE and/or COLOR
Selected models are wattage and color (CCT) selectable.
Model# FFLE/2-015 to 100
Remove the metal knockout cap on the fixture’s rear to access the dip
switches. Adjust the settings for wattage and light color (CCT) as needed.
After making the adjustments, replace and secure the metal knockout cap.
(Figure 1).
Model# FFLE/2-120 to 300
Remove the metal knockout cap on the fixture’s rear to access the dip
switches. Adjust the settings for wattage and light color (CCT) as needed.
After making the adjustments, replace and secure the metal knockout cap.
(Figure 2).
MOUNTING OPTIONS
Mounting options vary by models, please find below the mounting options and
applicable models.
Knuckle Mount
The knuckle mount can be attached to a conduit using the appropriate
coupling. (Figure 3). Or can be installed to a junction box. (Figure 4)
Flood Mount
The flood mount can be attached to the suface such as wall or ceiling
(Figure 5).
Model# FFLE/2-120 to 300 (Standard)
Model# FFLE/2-015 to 100 (Optional)
Remove the knuckle mount from fixture, attach the flood mount (Figure 7).
Trunnion Mount (Optional)
Drill (2) 3/8” holes with 4” spacing on the wall/surface, insert the bolts
with hammer, as shown in (Figure 8). Mount the fixtures to the bolts and
tighten the bolts.
Model# FFLE/2-015 to 100
Remove the knuckle mount from fixture, attach the trunnion mount (Figure 10).
Model# FFLE/2-120 to 300
Remove the flood mount from fixture, attach the trunnion mount (Figure 11).
Slipfitter Mount (Optional)
Slipfitter is designed for the fixture mounted onto a up to 2-3/8 inch
tenon as shown in (Figure 12). Mount the fixtures to the pole and tighten the
locking bolts.
Model# FFLE/2-080 to 100
Remove the knuckle mount from fixture, attach the trunnion mount (Figure 13).
Model# FFLE/2-120 to 300
Remove the flood mount from fixture, attach the trunnion mount (Figure 14).
PHOTOCELL SENSOR
Model# FFLE/2-015 to 100 (Standard)
Selected models come standard with photocell sensor. Remove the transparent
plastic knockout cap on the fixture’s rear to access the dip switch. Turn
on(enable) and off(disable) the sensor as needed. After making the
adjustments, replace and secure the knockout cap. (Figure 15).
Model# FFLE/2-120 to 300 (Optional)
If the photosensor option is selected, the fixture will have NEMA twist lock
control receptacle, twist in the photocell control to enable the sensor, or
use a short-cap if opt to not install a twist-lock photocell, see (Figure 16).
Need help? (800) 988 -6386