Product Specifications

  • Weight: 2.0kg / 4.4lbs
  • Cable Length (On/Off): 100mm / 3.9
  • Dimensions (Micro): 185mm / 7.3 x 70mm / 2.8

Product Usage Instructions

Mounting Guide

To mount the Washer Go Micro, follow these steps:

  1. Install expansion screws on the fixed surface.
  2. Fix the bracket using M10 expansion bolts.
  3. Adjust the luminaire to the desired angles.
  4. Secure the bracket using M10 nuts.
  5. Tighten the bracket bolts to fix the luminaire at the desired angle using a 6mm Hex Key.

Safety Instructions

A safety wire must be installed to provide secondary protection against fixtures falling and injuring people.

System Diagram (DC DMX)

For system connections, use the IP66 Junction Box for DMX IN and DC24V IN. Use appropriate cables for interconnections.

Frequently Asked Questions (FAQ):

How many fixtures can be connected per power line?

  • For 25W fixtures: maximum of 5 pcs for 24VDC (CE) or 3 pcs for 24VDC (US Class 2 PSU).
  • For 36W fixtures: maximum of 4 pcs for 24VDC (CE) or 2 pcs for 24VDC (US Class 2 PSU).

What is the maximum distance between fixtures?

  • The maximum distance between fixtures is 30m / 98′ for some models and 12m / 39′ for others.

What is the maximum distance from the control source to the last fixture on a single DMX512 link?

  • The maximum distance is 200m / 656′ for both control and addressing sources.

Dimensions Micro

Fixture Dimensions (Without Glare Shield)TRAXON-Washer-Go-Maxi-RGBW-
Light-FIG-1

Fixture Dimensions (With Glare Shield)TRAXON-Washer-Go-Maxi-RGBW-Light-
FIG-2

Dimensions (Mini)TRAXON-Washer-Go-Maxi-RGBW-Light-
FIG-3

Dimensions (Midi)TRAXON-Washer-Go-Maxi-RGBW-Light-
FIG-4

Dimensions (Maxi)TRAXON-Washer-Go-Maxi-RGBW-Light-
FIG-5

Mounting

  • Install expansion screws on the fixed surfaceTRAXON-Washer-Go-Maxi-RGBW-Light-FIG-6-1
  • Fix the bracket
  • Adjust desired angles
  • Tighten the bracket bolts to fix the luminaire to the desired angle

System Diagram DC DMX

TRAXON-Washer-Go-Maxi-RGBW-Light-FIG-7

  • Data cabling from the DMX source to the Starter cable shall be Cat5e UTP or other cable types suitable for DMX communication.
  • Maximum number of 25W fixtures per input power line: 5 pcs for 24VDC (CE); 3 pcs for 24VDC (US Class 2 PSU).
  • Maximum number of 36W fixtures per input power line: 4 pcs for 24VDC (CE); 2 pcs for 24VDC (US Class 2 PSU).
  For controlling the fixtures For addressing the fixtures
Maximum distance from Control/Addressing source to the first fixture 80m /
262’ 80m / 262’
Maximum distance between fixture to fixture 30m / 98’ 12m / 39’

Maximum distance from Control source to the last fixture on a single DMX512 link| 200m / 656’| 200m / 656’
Maximum number of fixtures on a single DMX512 link| 40pcs| 40pcs
Maximum number of fixtures is based on minimal interconnection lengths from fixture to fixture.

Actual number of fixtures is dependent on cable interconnection lengths. The number of fixtures will reduce if longer cable lengths are used. Please consult the regional sales office to confirm maximums.

System Diagram (DC On / Off)

TRAXON-Washer-Go-Maxi-RGBW-Light-FIG-9

  • Maximum number of 25W fixtures per input power line: 5 pcs for 24VDC (CE); 3 pcs for 24VDC (US Class 2 PSU).
  • Maximum number of 36W fixtures per input power line: 4 pcs for 24VDC (CE); 2 pcs for 24VDC (US Class 2 PSU).
Function Wire Size Color Connection
DC24V+ 1.0mm2 Black
DC24V- 1.0mm2 White

System Diagram (AC DMX)

TRAXON-Washer-Go-Maxi-RGBW-Light-FIG-12

  For controlling the fixtures For addressing the fixtures
Maximum distance from Control/Addressing source to the first fixture 80m /
262’ 80m / 262’
Maximum distance between fixture to fixture 30m / 98’ 12m / 39’

Maximum distance from the Control source to the last fixture on a single DMX512 link| 200m / 656’| 200m / 656’
Maximum number of fixtures on a single DMX512 link| 40pcs| 40pcs
Maximum number of fixtures is based on minimal interconnection lengths from fixture to fixture.

Actual number of fixtures is dependent on cable interconnection lengths. The number of fixtures will reduce if longer cable lengths are used. Please consult the regional sales office to confirm maximums.

  • Data cabling from the DMX source to the Starter cable shall be Cat5e UTP or other cable type suitable for DMX communication.

System Diagram (AC On / Off)TRAXON-Washer-Go-Maxi-RGBW-Light-
FIG-14

Effective Projected Area EPA

Model Micro Mini Midi Maxi
Front 21838mm² / 0.24ft² (without Glare Shield ) 22440mm² / 0.24ft² (with
Glare Shield ) 31852mm² / 0.34ft² 47425mm² / 0.51ft² 66475mm² / 0.72ft²
Side 12010mm² / 0.13ft² (without Glare Shield ) 18092mm² / 0.19ft² (with
Glare Shield ) 39108mm² / 0.42ft² 55785mm² / 0.6ft² 76935mm² / 0.83ft²
  • THIS FIXTURE IS SUITABLE FOR OUTDOOR OR INDOOR USE.
  • DO NOT STARE AT THE OPERATING LIGHT SOURCE.
  • THE LUMINAIRE SHOULD BE POSITIONED SO THAT PROLONGED STARING INTO THE LUMINAIRE AT A DISTANCE CLOSER THAN 4 M IS NOT EXPECTED.
  • MINIMUM DISTANCE FROM LIGHTED OBJECTS IS 0.3 M.
  • CONNECT TO THE POWER SUPPLY UNDER NATIONAL REGULATIONS.
  • THE EXTERNAL FLEXIBLE CABLE OR CORD OF THIS LUMINAIRE CANNOT BE REPLACED; IF THE CORD IS DAMAGED, THE LUMINAIRE SHALL BE DESTROYED.
  • THE LIGHT SOURCE OF THIS LUMINAIRE IS NOT REPLACEABLE; WHEN THE LIGHT SOURCE REACHES ITS END OF LIFE THE WHOLE LUMINAIRE SHALL BE REPLACED.
  • INSTALLATION/MAINTENANCE ONLY BY SKILLED PERSONNEL.
  • DURING OVERHAUL/MAINTENANCE ONLY USE ORIGINAL PARTS.
  • IF ANY LUMINAIRE IS SUBSEQUENTLY MODIFIED, THE PERSON RESPONSIBLE FOR THE MODIFICATION SHALL BE CONSIDERED THE MANUFACTURER.
  • THE MANUFACTURER BEARS NO LIABILITY FOR DAMAGE CAUSED BY INAPPROPRIATE USE OR APPLICATION.
  • TO REDUCE THE RISK OF STRANGULATION THE FLEXIBLE WIRING CONNECTED TO THIS LUMINAIRE SHALL BE EFFECTIVELY FIXED TO THE WALL IF THE WIRING IS WITHIN ARM’S REACH.
  • www.traxon-ecue.com
  • ©2023 TRAXON TECHNOLOGIES. ALL RIGHTS RESERVED.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals