TRAXON Washer Go Maxi RGBW Light User Guide
- June 17, 2024
- traxon
Table of Contents
TRAXON Washer Go Maxi RGBW Light
Product Specifications
- Weight: 2.0kg / 4.4lbs
- Cable Length (On/Off): 100mm / 3.9
- Dimensions (Micro): 185mm / 7.3 x 70mm / 2.8
Product Usage Instructions
Mounting Guide
To mount the Washer Go Micro, follow these steps:
- Install expansion screws on the fixed surface.
- Fix the bracket using M10 expansion bolts.
- Adjust the luminaire to the desired angles.
- Secure the bracket using M10 nuts.
- Tighten the bracket bolts to fix the luminaire at the desired angle using a 6mm Hex Key.
Safety Instructions
A safety wire must be installed to provide secondary protection against fixtures falling and injuring people.
System Diagram (DC DMX)
For system connections, use the IP66 Junction Box for DMX IN and DC24V IN. Use appropriate cables for interconnections.
Frequently Asked Questions (FAQ):
How many fixtures can be connected per power line?
- For 25W fixtures: maximum of 5 pcs for 24VDC (CE) or 3 pcs for 24VDC (US Class 2 PSU).
- For 36W fixtures: maximum of 4 pcs for 24VDC (CE) or 2 pcs for 24VDC (US Class 2 PSU).
What is the maximum distance between fixtures?
- The maximum distance between fixtures is 30m / 98′ for some models and 12m / 39′ for others.
What is the maximum distance from the control source to the last fixture on a single DMX512 link?
- The maximum distance is 200m / 656′ for both control and addressing sources.
Dimensions Micro
Fixture Dimensions (Without Glare Shield)
Fixture Dimensions (With Glare Shield)
Dimensions (Mini)
Dimensions (Midi)
Dimensions (Maxi)
Mounting
- Install expansion screws on the fixed surface
- Fix the bracket
- Adjust desired angles
- Tighten the bracket bolts to fix the luminaire to the desired angle
System Diagram DC DMX
- Data cabling from the DMX source to the Starter cable shall be Cat5e UTP or other cable types suitable for DMX communication.
- Maximum number of 25W fixtures per input power line: 5 pcs for 24VDC (CE); 3 pcs for 24VDC (US Class 2 PSU).
- Maximum number of 36W fixtures per input power line: 4 pcs for 24VDC (CE); 2 pcs for 24VDC (US Class 2 PSU).
For controlling the fixtures | For addressing the fixtures | |
---|---|---|
Maximum distance from Control/Addressing source to the first fixture | 80m / | |
262’ | 80m / 262’ | |
Maximum distance between fixture to fixture | 30m / 98’ | 12m / 39’ |
Maximum distance from Control source to the last fixture on a single DMX512
link| 200m / 656’| 200m / 656’
Maximum number of fixtures on a single DMX512 link| 40pcs| 40pcs
Maximum number of fixtures is based on minimal interconnection lengths from
fixture to fixture.
Actual number of fixtures is dependent on cable interconnection lengths. The number of fixtures will reduce if longer cable lengths are used. Please consult the regional sales office to confirm maximums.
System Diagram (DC On / Off)
- Maximum number of 25W fixtures per input power line: 5 pcs for 24VDC (CE); 3 pcs for 24VDC (US Class 2 PSU).
- Maximum number of 36W fixtures per input power line: 4 pcs for 24VDC (CE); 2 pcs for 24VDC (US Class 2 PSU).
Function | Wire Size | Color | Connection |
---|---|---|---|
DC24V+ | 1.0mm2 | Black | |
DC24V- | 1.0mm2 | White |
System Diagram (AC DMX)
For controlling the fixtures | For addressing the fixtures | |
---|---|---|
Maximum distance from Control/Addressing source to the first fixture | 80m / | |
262’ | 80m / 262’ | |
Maximum distance between fixture to fixture | 30m / 98’ | 12m / 39’ |
Maximum distance from the Control source to the last fixture on a single
DMX512 link| 200m / 656’| 200m / 656’
Maximum number of fixtures on a single DMX512 link| 40pcs| 40pcs
Maximum number of fixtures is based on minimal interconnection lengths from
fixture to fixture.
Actual number of fixtures is dependent on cable interconnection lengths. The number of fixtures will reduce if longer cable lengths are used. Please consult the regional sales office to confirm maximums.
- Data cabling from the DMX source to the Starter cable shall be Cat5e UTP or other cable type suitable for DMX communication.
System Diagram (AC On / Off)
Effective Projected Area EPA
Model | Micro | Mini | Midi | Maxi |
---|---|---|---|---|
Front | 21838mm² / 0.24ft² (without Glare Shield ) 22440mm² / 0.24ft² (with | |||
Glare Shield ) | 31852mm² / 0.34ft² | 47425mm² / 0.51ft² | 66475mm² / 0.72ft² | |
Side | 12010mm² / 0.13ft² (without Glare Shield ) 18092mm² / 0.19ft² (with | |||
Glare Shield ) | 39108mm² / 0.42ft² | 55785mm² / 0.6ft² | 76935mm² / 0.83ft² |
- THIS FIXTURE IS SUITABLE FOR OUTDOOR OR INDOOR USE.
- DO NOT STARE AT THE OPERATING LIGHT SOURCE.
- THE LUMINAIRE SHOULD BE POSITIONED SO THAT PROLONGED STARING INTO THE LUMINAIRE AT A DISTANCE CLOSER THAN 4 M IS NOT EXPECTED.
- MINIMUM DISTANCE FROM LIGHTED OBJECTS IS 0.3 M.
- CONNECT TO THE POWER SUPPLY UNDER NATIONAL REGULATIONS.
- THE EXTERNAL FLEXIBLE CABLE OR CORD OF THIS LUMINAIRE CANNOT BE REPLACED; IF THE CORD IS DAMAGED, THE LUMINAIRE SHALL BE DESTROYED.
- THE LIGHT SOURCE OF THIS LUMINAIRE IS NOT REPLACEABLE; WHEN THE LIGHT SOURCE REACHES ITS END OF LIFE THE WHOLE LUMINAIRE SHALL BE REPLACED.
- INSTALLATION/MAINTENANCE ONLY BY SKILLED PERSONNEL.
- DURING OVERHAUL/MAINTENANCE ONLY USE ORIGINAL PARTS.
- IF ANY LUMINAIRE IS SUBSEQUENTLY MODIFIED, THE PERSON RESPONSIBLE FOR THE MODIFICATION SHALL BE CONSIDERED THE MANUFACTURER.
- THE MANUFACTURER BEARS NO LIABILITY FOR DAMAGE CAUSED BY INAPPROPRIATE USE OR APPLICATION.
- TO REDUCE THE RISK OF STRANGULATION THE FLEXIBLE WIRING CONNECTED TO THIS LUMINAIRE SHALL BE EFFECTIVELY FIXED TO THE WALL IF THE WIRING IS WITHIN ARM’S REACH.
- www.traxon-ecue.com
- ©2023 TRAXON TECHNOLOGIES. ALL RIGHTS RESERVED.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>