3nStar SCI150 Imager Handheld Barcode Scanner 1D USB with Base User Manual

June 17, 2024
3nStar

3nStar SCI150 Imager Handheld Barcode Scanner 1D USB with Base

Specifications

  • Scanner Overview
  • Cable Plug & Unplug
  • Data Cable Connection Guide
  • Scanning Angle
  • Methods and Distance

Scanner Overview

The scanner is a handheld device designed for scanning barcodes.
It is equipped with various settings and features to enhance the scanning experience.

Cable Plug & Unplug
When plugging or unplugging the cable, ensure that the scanner and the connected device are powered off. Align the connector with the port and gently insert or remove it to avoid any damage.

Data Cable Connection Guide
Follow these steps to connect the data cable:

  1. Identify the appropriate port on the scanner and the connected device.
  2. Insert one end of the data cable into the scanner’s port.
  3. Insert the other end of the data cable into the corresponding port on the connected device.

Scanner Overview

Barcode scanner

Cable Plug & Unplug

( Pluggable scanner applies)

  1. Plug as picture above

  2. Press the buckle click, and pull out the cable

Data Cable Connection Guide

USB cable

3nStar-SCI15-Imager-Handheld-Barcode-Scanner-1D-USB-with-Base-
\(5\)

Lights Indicator
3nStar-SCI15-Imager-Handheld-Barcode-Scanner-1D-USB-with-Base-
\(6\)

Scanning Angle

3nStar-SCI15-Imager-Handheld-Barcode-Scanner-1D-USB-with-Base-
\(7\)

Methods and Distance

3nStar-SCI15-Imager-Handheld-Barcode-Scanner-1D-USB-with-Base-
\(8\)

NOTE: Red LED light should fully cover on the bar code

Troubleshooting Q&A

  1. Q: USB barcode scanner with “beep beep beep” after scanning and no data uploaded.
    Al: Unplug and plug the scanner into another USB port.

  2. Q2: USB barcode scanner without data upload and alarm buzzer after scanning .
    A2: Restore factory default.

  3. Q3. How to set barcode data with increase and decrease digits when scanning barcodes?
    A3 : Refer to barcode settings as 1oand11,12to set the scanner.

Barcode Setting`s

Setting Step

3nStar-SCI15-Imager-Handheld-Barcode-Scanner-1D-USB-with-Base-
\(9\)

Note: All functions must be in accordance with the settings for The above process or scan the bar code setting function is invalid.

  1. Restore Factory Default

  2. Note: 1. Restore factory default will not change the interface
    Mode.Refer to Interface Mode Selection for setting the interface

  3. With”in bold means factory default parameter

Interface Mode Selection

Setting step as below with function barcodes when using USB to transfer data

Auto Sensing

Trigger Mode

  • Single read: when a bar code has been decoded, the reader will be turned off. The reader must be triggered again to read another label.
  • Continuous: The reader will produce as much data as it can decode regardless whether it is the same or not.
  • This mode is mainly used for demonstration and diagnosis

Reading Mode

.

  • Disable repeat read: Disable continue to read the same barcode.
  • Multiple read: The same label can only be decoded again after the label has not been detected for a number of scans. This mode can only be programmed in Continuous read triooer mode

Repeat the same barcode reading interval.

Set Suffix

Version Reading

Code 32 Setting

(Italian Pharma code)

Code 39 Setting

UPC Setting

Delete Some Characters

www.3nstar.com