Pioneer FYB018GMFILCAD 18,000 BTU Floor Mounted Mini Split Heat Pump Instruction Manual
- June 17, 2024
- Pioneer
Table of Contents
- Pioneer FYB018GMFILCAD 18,000 BTU Floor Mounted Mini Split Heat Pump
- Product Information
- Product Usage Instructions
- FAQs
- Safety Precautions
- Unit Specifications and Features
- Care and Maintenance
- Troubleshooting
- Accessories
- Indoor Unit Installation
- PIPING EXTENSION BEYOND FLARE FORM
- Indoor Unit Wiring
- Test Run
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Pioneer FYB018GMFILCAD 18,000 BTU Floor Mounted Mini Split Heat Pump
Product Information
Specifications
- Model: FYB018GMFILCAD
- Type: Ductless Single-Way Cassette Inverter++ Air Conditioner / Heat Pump System
- Series: Quantum Inverter
- Floor Console: FYB-22 18K
Product Usage Instructions
Safety Precautions
Before operating or installing the air conditioning system, it is important to read and understand the following safety precautions:
Warnings for Product Use
1. It is highly recommended to use designed air-conditioning units.
Cleaning and Maintenance Warnings
1. Clean the unit regularly to prevent fire or deformation.
2. Do not clean the unit if the humidity is very high.
Electrical Warnings
1. Take note of the fuse specifications printed on the circuit board. Examples include T3.15A/250VAC, T5A/250VAC, T10A/250VAC, T20A/250VACT30A/250VAC, etc.
NOTE: For units with R32 or R290 refrigerant, only blast-proof ceramic fuses can be used.
Warnings for Product Installation
- Installation must be performed by an authorized dealer or specialist to avoid water leakage, electrical shock, or fire.
- Follow the installation instructions carefully to prevent water leakage, electrical shock, or fire. In North America, installation must comply with NEC and CEC requirements and should be done by authorized personnel only.
- Contact an authorized service technician for repair or maintenance of the unit. Installation should adhere to national wiring regulations.
- Use only the included accessories, parts, and specified parts for installation. The use of non-standard parts can result in water leakage, electrical shock, fire, and unit failure.
- Install the unit in a firm location that can support its weight. Improper installation or inadequate support may cause the unit to drop, resulting in serious injury and damage.
FAQs
- Who should install the air conditioning system?
- The installation must be performed by an authorized dealer or specialist.
- What type of fuse should be used for the air conditioner’s circuit board?
- The specifications of the fuse are printed on the circuit board. Examples include T3.15A/250VAC, T5A/250VAC, T10A/250VAC, T20A/250VACT30A/250VAC, etc. For units with R32 or R290 refrigerant, only blast-proof ceramic fuses can be used.
- What should I do if there is water leakage, electrical shock, or fire during installation or operation?
- If you experience any of these issues, immediately contact an authorized service technician for repair or maintenance.
- Can I use non-standard parts for installation?
- No, it is important to use only the included accessories, parts, and specified parts for installation to avoid water leakage, electrical shock, fire, and unit failure.
- What precautions should I take during installation to prevent injury or damage?
- Ensure that the unit is installed in a firm location that can support its weight. If the chosen location cannot support the unit’s weight or if the installation is not done properly, the unit may drop and cause serious injury and damage.
DUCTLESS SINGLE-WAY CASSETTE INVERTER++ AIR CONDITIONER / HEAT PUMP SYSTEM
QUANTUM INVERTER SERIES (FYB-22 18K FLOOR CONSOLE)
OWNER’S AND INSTALLATION MANUAL
Model Numbers Encompassed:
FYB018GMFILCAD
IMPORTANT NOTE: Read this manual carefully before installing or operating your
new air conditioning system. Make sure to save this manual for future
reference.
© PARKER DAVIS HVAC INTERNATIONAL, INC., ALL RIGHTS RESERVED. REVISION 09-2023
Safety Precautions
Safety Precautions
Read Safety Precautions Before Operation and Installation
Incorrect installation due to ignoring instructions can cause serious damage
or injury. The seriousness of potential damage or injuries is classified as
either a WARNING or CAUTION .
WARNING
This symbol indicates the possibility of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of property damage or serious
consequences.
WARNING
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision EN Standard requirements
.
This appliance is not intended for use by persons(including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
WARNINGS FOR PRODUCT USE
· If an abnormal situation arises (like a burning smell), immediately turn off
the unit and disconnect the power. Call your dealer for instructions to avoid
electric shock, fire or injury.
· Do not insert fingers, rods or other objects into the air inlet or outlet.
This may cause injury, since the fan may be rotating at high speeds.
· Do not use flammable sprays such as hair spray, lacquer or paint near the
unit. This may cause fire or combustion.
· Do not operate the air conditioner in places near or around combustible
gases. Emitted gas may collect around the unit and cause explosion.
· Do not operate your air conditioner in a wet room such as a bathroom or
laundry room. Too much exposure to water can cause electrical components to
short circuit.
· Do not expose your body directly to cool or hot air for a prolonged period
of time.
· Do not allow children to play with the air conditioner. Children must be
supervised around the unit at all times.
· If the air conditioner is used together with burners or other heating
devices, thoroughly ventilate
the room to avoid oxygen deficiency. · In certain functional environments,
such as kitchens, server rooms, etc., the use of specially
designed air-conditioning units is highly recommended.
Page 4
Safety Precautions
CLEANING AND MAINTENANCE WARNINGS
· Turn off the device and disconnect the power before cleaning. Failure to do
so can cause electrical shock.
· Do not clean the air conditioner with excessive amounts of water. · Do not
clean the air conditioner with combustible cleaning agents. Combustible
cleaning agents
can cause fire or deformation.
CAUTION
· Turn off the air conditioner and disconnect the power if you are not going
to use it for a long time. · Turn off and unplug the unit during storms. ·
Make sure that water condensation can drain unhindered from the unit. · Do not
operate the air conditioner with wet hands. This may cause electric shock. ·
Do not use device for any other purpose than its intended use. · Do not climb
onto or place objects on top of the outdoor unit. · Do not allow the air
conditioner to operate for long periods of time with doors or windows open,
or if the humidity is very high.
ELECTRICAL WARNINGS
· Only use the specified power cord. If the power cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
· Keep power plug clean. Remove any dust or grime that accumulates on or
around the plug. Dirty plugs can cause fire or electric shock.
· Do not pull power cord to unplug unit. Hold the plug firmly and pull it from
the outlet. Pulling directly on the cord can damage it, which can lead to fire
or electric shock.
· Do not modify the length of the power supply cord or use an extension cord
to power the unit. · Do not share the electrical outlet with other appliances.
Improper or insufficient power supply
can cause fire or electrical shock. · The product must be properly grounded at
the time of installation, or electrical shock may occur. · For all electrical
work, follow all local and national wiring standards, regulations, and the
Installation Manual. Connect cables tightly, and clamp them securely to
prevent external forces from damaging the terminal. Improper electrical
connections can overheat and cause fire, and may also cause shock. All
electrical connections must be made according to the Electrical Connection
Diagram located on the panels of the indoor and outdoor units. · All wiring
must be properly arranged to ensure that the control board cover can close
properly. If the control board cover is not closed properly, it can lead to
corrosion and cause the connection points on the terminal to heat up, catch
fire, or cause electrical shock. · If connecting power to fixed wiring, an
all-pole disconnection device which has at least 3mm clearances in all poles,
and have a leakage current that may exceed 10mA, the residual current
device(RCD) having a rated residual operating current not exceeding 30mA, and
disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules.
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner’s circuit board (PCB) is designed with a fuse to provide
overcurrent protection. The specifications of the fuse are printed on the
circuit board ,such as : T3.15A/250VAC, T5A/250VAC, T10A/250VAC, T20A/250VAC
T30A/250VAC, etc. NOTE: For the units with R32 or R290 refrigerant , only the
blast-proof ceramic fuse can be used.
Page 5
Safety Precautions
WARNINGS FOR PRODUCT INSTALLATION
1. Installation must be performed by an authorized dealer or specialist.
Defective installation can cause water leakage, electrical shock, or fire.
2. Installation must be performed according to the installation instructions.
Improper installation can cause water leakage, electrical shock, or fire. In
North America,installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel only.)
3. Contact an authorized service technician for repair or maintenance of this
unit. This appliance shall be installed in accordance with national wiring
regulations.
4. Only use the included accessories, parts, and specified parts for
installation. Using non-standard parts can cause water leakage, electrical
shock, fire, and can cause the unit to fail.
5. Install the unit in a firm location that can support the unit’s weight. If
the chosen location cannot support the unit’s weight, or the installation is
not done properly, the unit may drop and cause serious injury and damage.
6. Install drainage piping according to the instructions in this manual.
Improper drainage may cause water damage to your home and property.
7. For units that have an auxiliary electric heater, do not install the unit
within 1 meter (3 feet) of any combustible materials.
8. Do not install the unit in a location that may be exposed to combustible
gas leaks. If combustible gas accumulates around the unit, it may cause fire.
9. Do not turn on the power until all work has been completed. 10. When
moving or relocating the air conditioner, consult experienced service
technicians for
disconnection and reinstallation of the unit. 11. How to install the appliance
to its support, please read the information for details in “indoor unit
installation” and “outdoor unit installation” sections .
Note about Fluorinated Gasses(Not applicable to the unit using R290
Refrigerant)
1. This air-conditioning unit contains fluorinated greenhouse gasses. For
specific information on the type of gas and the amount, please refer to the
relevant label on the unit itself or the “Owner’s Manual – Product Fiche ” in
the packaging of the outdoor unit. (European Union products only).
2. Installation, service, maintenance and repair of this unit must be
performed by a certified technician.
3. Product uninstallation and recycling must be performed by a certified
technician. 4. For equipment that contains fluorinated greenhouse gases in
quantities of 5 tonnes of CO2
equivalent or more, but of less than 50 tonnes of CO2 equivalent, If the
system has a leakdetection system installed, it must be checked for leaks at
least every 24 months. 5. When the unit is checked for leaks, proper record-
keeping of all checks is strongly recommended.
Page 6
Safety Precautions
WARNING for Using R32/R290 Refrigerant
When flammable refrigerant are employed, appliance shall be stored in a well
-ventilated area where the room size corresponds to the room area as specifiec
for operation. For R32 frigerant models: Appliance shall be installed,
operated and stored in a room with a floor area larger than X m² . Appliance
shall not be installed in an unvertilated space, if that space is smaller than
X m² (Please see the following form).
Model (Btu/h)
18000
Minimum room area (m²)
18
Reusable mechanical connectors and flared joints are not allowed indoors. (EN Standard Requirements). Mechanical connectors used indoors shall have a rate of not more than 3g/year at 25% of the maximum allowable pressure. When mechanical connectors are reused indoors, sealing parts shall be renewed. When flared joints are reused indoors, the flare part shall be re-fabricated. (UL Standard Requirements) When mechanical connectors are reused indoors, sealing parts shall be renewed. When flared joints are reused indoors, the flare part shall be re-fabricated. (IEC Standard Requirements) Mechanical connectors used indoors shall comply with ISO 14903.
Page 7
Unit Specifications and Features
Unit Specifications and Features
Indoor unit display
NOTE: This display panel on the indoor unit can be used to operate the unit in
case the remote control has been misplaced or is out of batteries.
Air flow louver (at air outlet)
Air inlet (with air filter in it) Air flow louver (at air outlet)
Display panel
Display panel
Refrigerant connecting pipe Drain hose
·
Displays temperature and Error codes:
” ” when defrosting(for model B cooling & heating units)
” ” for 3 seconds when: · TIMER ON is set · SWING or SILENCE is turned on
” ” for 3 seconds when: · TIMER OFF is set · SWING or SILENCE is turned off
” ” when unit is self-cleaning
” ” when 8 C heating feature is turned on
·
When ECO function(some units) is activated.
·
when Wireless Control feature is activated
(some units)
Page 9
Unit Specifications and Features
Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the unit to disable.
Inverter Split Type
COOL mode
Room Temperature
16°C – 32°C (60°F – 90°F)
HEAT mode
0°C – 30°C (32°F – 86°F)
0°C – 50°C (32°F – 122°F)
Outdoor Temperature
-15°C – 50°C (5°F – 122°F)
(For models with low temp. cooling systems.)
-15°C – 24°C (5°F – 75°F)
DRY mode 10°C – 32°C (50°F – 90°F)
0°C – 50°C (32°F – 122°F)
FOR OUTDOOR UNITS WITH AUXILIARY ELECTRIC HEATER
When outside temperature is below 0°C (32°F ), we strongly recommend keeping
the unit plugged in at all time to ensure smooth ongoing performance.
0°C – 52°C (32°F – 126°F)
(For special tropical models)
0°C – 52°C (32°F – 126°F)
(For special tropical models)
Fixed-speed Type
COOL mode
Room Temperature
16°C-32°C (60°F-90°F)
18°C-43°C (64°F-109°F)
Outdoor Temperature
-7°C-43°C (19°F-109°F) (For models with low-temp cooling systems)
18°C-52°C (64°F-126°F)
(For special tropical models)
HEAT mode 0°C-30°C (32°F-86°F)
-7°C-24°C (19°F-75°F)
DRY mode
10°C-32°C (50°F-90°F) 11°C-43°C (52°F-109°F) 18°C-43°C (64°F-109°F) 18°C-52°C
(64°F-126°F) (For special tropical models)
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
To further optimize the performance of your unit, do the following: · Keep doors and windows closed. · Limit energy usage by using TIMER ON and TIMER OFF functions. · Do not block air inlets or outlets. · Regularly inspect and clean air filters.
Page 10
Unit Specifications and Features
Adjusting Air Flow Direction
· Manual Swing: Press Air Direction to fix the louver at a desired angle.The
louver swings (upward or downward) at a different angle with each press of the
button. The air direction can be changed by manually adjusting air louver.
· Lower air louver switch setting Under the condition of meeting the ambient temperature, the lower air louver can be opened when the unit is turned on. To select whether the lower air louver is on or off, use the button on the electric control box. Within 10 minutes of power-on, press it for 5 seconds to enter the mode in standby state. Press it to open or close the lower air louver.
· When cooling Adjust the louver downwards (horizontally).
Air louver button
Electric control box
NOTE: During the setting process, the display panel displays the switch status
of the lower air louver. on – open of – closed
· When heating Adjust the louver vertically.
CAUTION
Do not try to adjust the horizontal louver by hand. This may cause damage the
mechanism and result in condensation forming on the air outlets.
Page 12
Care and Maintenance
Care and Maintenance
Cleaning Your Indoor Unit
BEFORE CLEANING OR MAINTENANCE
ALWAYS TURN OFF YOUR AIR CONDITIONER SYSTEM AND DISCONNECT ITS POWER SUPPLY
BEFORE CLEANING OR MAINTENANCE.
CAUTION
Only use a soft, dry cloth to wipe the unit clean. If the unit is especially
dirty, you can use a cloth soaked in warm water to wipe it clean.
· Do not use chemicals or chemically treated cloths to clean the unit
· Do not use benzene, paint thinner, polishing powder or other solvents to
clean the unit. They can cause the plastic surface to crack or deform.
· Do not use water hotter than 40°C (104°F) to clean the front panel. This can
cause the panel to deform or become discolored.
4. Clean the air filter by vacuuming the surface or washing it in warm water
with mild detergent.
5. Rinse the filter with clean water and allow it to air-dry. DO NOT let the
filter dry in direct sunlight.
6. Reinstall the filter.
Cleaning Your Air Filter
A clogged air conditioner can reduce the cooling efficiency of your unit, and
can also be bad for your health. Make sure to clean the filter once every two
weeks.
WARNING: DO NOT REMOVE OR CLEAN THE FILTER BY YOURSELF
Removing and cleaning the filter can be dangerous. Removal and maintenance
must be performed by a certified technician.
1. Pull the left and right handles of the front panel , pull the panel
outward, and open the panel.
2. Remove the air filter. Press the claws on the right and left sides of the
air filter down slightly, then pull upward.
3. Hold the tabs of the frame,and remove the 4 claws. (The special function
filter can be washed with water once every 6 months. It isrecommended that you
replace it once every 3 years.)
Air freshening filter
If using water, the inlet side should face down and away from the water stream.
If using a vacuum cleaner, the inlet side should face the vacuum.
Page 13
Care and Maintenance
CAUTION
Maintenance Long Periods of Non-Use
· Before changing the filter or cleaning, turn off the unit and disconnect its
power supply.
· When removing filter, do not touch metal parts in the unit. The sharp metal
edges can cut you.
· Do not use water to clean the inside of the indoor unit. This can destroy
insulation and cause electrical shock.
· Do not expose filter to direct sunlight when drying. This can shrink the
filter.
· Any maintenance and cleaning of outdoor
If you plan not to use your air conditioner for an extended period of time, do the following:
Clean all filters
Turn on FAN function until unit dries out completely
unit should be performed by an authorized
dealer or a licensed service provider.
· Any unit repairs should be performed by an
authorized dealer or a licensed service provider.
Replace internal parts
Turn off the unit and disconnect the power
Remove batteries from remote control
1. Pull the left and right handles of the front panel , pull the panel outward, and open the panel.
Maintenance Pre-Season Inspection
2. Remove the 7 screws on the face frame.
After long periods of non-use, or before periods of frequent use, do the following:
Check for damaged wires
Clean all filters
3. Buckle up the snap indicated by the arrow and remove the face frame.
Check for leaks
4. Replace internal parts. 5. Install the face frame and panel parts.
Replace batteries
Make sure nothing is blocking all air inlets and outlets
NOTE: Do not stretch or hang objects at the air outlet. Do not adjust the automatic air deflector by hand or extend your hand into the air duct. Do not cover the air inlet and outlet of the unit with objects.
Page 14
Troubleshooting
Troubleshooting
SAFETY PRECAUTIONS
If any of the following conditions occurs, turn off your unit immediately! ·
The power cord is damaged or abnormally warm · You smell a burning odor · The
unit emits loud or abnormal sounds · A power fuse blows or the circuit breaker
frequently trips · Water or other objects fall into or out of the unit DO NOT
ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER
IMMEDIATELY!
Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
Issue
Unit does not turn on when pressing ON/OFF button
Possible Causes
The Unit has a 3-minute protection feature that prevents the unit from
overloading. The unit cannot be restarted within three minutes of being turned
off.
Cooling and Heating Models: If the Operation light and PRE-DEF (Pre-heating/
Defrost) indicators are lit up, or the Operation light is lit up and the LCD
screen display “dF”, the outdoor temperature is too cold and the unit’s anti-
cold wind is activated in order to defrost the unit.
The unit changes from COOL mode to FAN mode
The indoor unit emits white mist Both the indoor and outdoor units emit white
mist
The indoor unit makes noises
Both the indoor unit and outdoor unit make noises
The unit may change its setting to prevent frost from forming on the unit.
Once the temperature increases, the unit will start operating in the
previously selected mode again. The set temperature has been reached, at which
point the unit turns off the compressor. The unit will continue operating when
the temperature fluctuates again.
In humid regions, a large temperature difference between the room’s air and
the conditioned air can cause white mist.
When the unit restarts in HEAT mode after defrosting, white mist may be
emitted due to moisture generated from the defrosting process.
A squeaking sound is heard when the system is OFF or in COOL mode. The noise
is also heard when the drain pump (optional) is in operation.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit’s plastic parts.
Low hissing sound during operation: This is normal and is caused by
refrigerant gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is
defrosting: This noise is normal and is caused by the refrigerant gas stopping
or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
Page 15
Troubleshooting
Issue The outdoor unit makes noises Dust is emitted from either the indoor or
outdoor unit
The unit emits a bad odor
The fan of the outdoor unit does not operate
Possible Causes
The unit will make different sounds based on its current operating mode.
The unit may accumulate dust during extended periods of non-use, which will be
emitted when the unit is turned on. This can be mitigated by covering the unit
during long periods of inactivity. The unit may absorb odors from the
environment (such as furniture, cooking, cigarettes, etc.) which will be
emitted during operations. The unit’s filters have become moldy and should be
cleaned.
During operation, the fan speed is controlled to optimize product operation.
NOTE: If problem persists, contact a local dealer or your nearest customer service center. Provide them with a detailed description of the unit malfunction as well as your model number.
Troubleshooting
When troubles occur, please check the following points before contacting a repair company.
Problem
Possible Causes
Solution
Temperature setting may be higher than ambient room temperature
Lower the temperature setting
Poor Cooling Performance
The heat exchanger on the indoor or outdoor unit is dirty
The air filter is dirty
The air inlet or outlet of either unit is blocked Doors and windows are open
Excessive heat is generated by sunlight
Too many sources of heat in the room (people, computers, electronics, etc.)
Low refrigerant due to leak or long-term use
Clean the affected heat exchanger
Remove the filter and clean it according to instructions Turn the unit off,
remove the obstruction and turn it back on Make sure that all doors and
windows are closed while operating the unit Close windows and curtains during
periods of high heat or bright sunshine
Reduce amount of heat sources
Check for leaks, re-seal if necessary and top off refrigerant
Page 16
Troubleshooting
Problem
The unit is not working
The unit starts and stops frequently
Poor heating performance
Indicator lamps continue flashing Error code appears and begins with the
letters as the following in the window display of indoor unit: · E(x), P(x),
F(x) · EH(xx), EL(xx), EC(xx) · PH(xx), PL(xx), PC(xx)
Possible Causes Power failure
Solution Wait for the power to be restored
The power is turned off
Turn on the power
The fuse is burned out
Replace the fuse
Remote control batteries are dead Replace batteries
The Unit’s 3-minute protection has been activated
Timer is activated
Wait three minutes after restarting the unit
Turn timer off
There’s too much or too little refrigerant in the system
Incompressible gas or moisture has entered the system.
System circuit is blocked
Check for leaks and recharge the system with refrigerant.
Evacuate and recharge the system with refrigerant
Determine which circuit is blocked and replace the malfunctioning piece of
equipment
The compressor is broken
The voltage is too high or too low
The outdoor temperature is extremely low
Cold air is entering through doors and windows
Low refrigerant due to leak or long-term use
Replace the compressor
Install a manostat to regulate the voltage Use auxiliary heating device
Make sure that all doors and windows are closed during use Check for leaks,
re-seal if necessary and top off refrigerant
The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself. If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists, disconnect the power and contact your nearest customer service center.
NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.
Page 17
Accessories
Accessories
The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air conditioner. Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail. The items are not included with the air conditioner must be purchased separately.
Name of Accessories Q`ty(pc)
Manual
2~4
Shape
Name of Accessories
Remote controller (some models)
Q`ty(pc) 1
Shape
Transfer connector
(12.7-15.9)
1
(some models)
Transfer connector
(6.35-9.52)
1
(some models)
Transfer connector
(9.52-12.7)
1
(some models)
Magnetic ring (wrap
the electric wires S1
& S2 ( P & Q & E )
1
around the magnetic
ring twice)
(some models)
Magnetic ring (Hitch
it on the connective
cable between indoor
1
unit and outdoor unit
after installation.)
(some models)
Wired remote
controller
1
(some models)
S1&S2(P&Q&E)
Battery (some models)
Soundproof / insulation sheath (some models) Heat insulation pipe
Anchor
Mounting plate fixing screw
Drain joint (some models) Seal ring (some models)
2
2
1
6 (depending on models)
6 (depending on models)
1
1
Copper nut
2
Red short connected wire (some models)
1
Air freshening filter
(some models)
2
Optional accessories
· There are two types of remote controls: wired and wireless. Select a remote
controller based on customer preferences and requirements and install in an
appropriate place. Refer to catalogues and technical literature for guidance
on selecting a suitable remote controller.
Name
Connecting pipe assembly
Shape
Liquid side
G as side
6.35( 1/4i n) 9.52( 3/8in) 12.7( 1/2in) 9.52( 3/8in) 12.7( 1/2in) 16( 5/8in) 19( 3/4in) 22( 7/8in)
Quantity(PC)
Parts you must purc hase separately. Consult the dealer about the proper pipe
size of the unit you purchased.
Page 18
Installation Summary
Installation Summary
1
2
3
Install the indoor unit
6
MC
MC
Install the drainpipe
5
Install the outdoor unit
4
Evacuate the refrigeration system
7
Connect the wires
Connect the refrigerant pipes
Perform a test run
Page 19
Unit Parts
NOTE: The installation must be performed in accordance with the requirement of
local and national standards. The installation may be slightly different in
different areas.
1
3 2 1
Unit Parts
1 Air flow louver (at air outlet) 2 Air inlet (with air filter in it) 3
Display panel 4 Drain pipe
6
5 Connecting pipe
6 Air inlet
7 Air outlet
7
5 4
6
NOTE ON ILLUSTRATIONS The piping can be connected from the left, right, rear
and lower sides of the unit. Please select the piping method according to the
actual demand. Illustrations in this manual are for explanatory purposes. The
actual shape of your indoor unit may be slightly different. The actual shape
shall prevail.
Page 20
Indoor Unit Installation
Installation Instructions Indoor unit
NOTE: Panel installation should be performed after piping and wiring have been completed.
Step 1: Select installation location Before installing the indoor unit, you
must choose an appropriate location. The following are standards that will
help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Enough room exists for installation and maintenance.
Enough room exists for the connecting the pipe and drainpipe.
The ceiling is horizontal and its structure can sustain the weight of the
indoor unit.
The air inlet and outlet are not blocked.
The airflow can fill the entire room.
There is no direct radiation from heaters.
DO NOT install unit in the following locations:
Areas with oil drilling or fracking
Coastal areas with high salt content in the air Areas with caustic gases in
the air, such as hot springs Areas that experience power fluctuations, such as
factories Enclosed spaces, such as cabinets
Kitchens that use natural gas
Areas with strong electromagnetic waves
Areas that store flammable materials or gas
Rooms with high humidity, such as bathrooms or laundry rooms
Recommended distances between the indoor unit The distance between the mounted indoor unit should meet the specifications illlustrated in the following diagram.
100mm
200mm
Indoor Unit Installation
621mm
150mm
794mm
150mm
1000mm
Page 21
Step 2: Installing the main body After loosening the screws, remove the
mounting plate from the unit.
Remove the mounting plate Loosen the screw
Loosen the screws(Only for left outlet pipe)
NOTE: If the pipe comes out on the left, it is necessary to loosen the screws
on the bottom mounting plate. If the pipe comes out in other directions, it is
not necessary.
Fix the mounting plate with a tapping screw onto the wall. NOTE: It is
recommended to fix it on the wall according to the hanging hole indicated by
the arrow on the mounting plate. Mounting plate must be installed
horizontally.
Hang the indoor unit on the mounting plate. (The bottom of body can touch the floor or remain suspended, but the body must be installed vertically.) NOTE: After installation, the unit shall be kept horizontal without tilting.
Mounting plate
Tapping screw Washer
6mm
Indoor Unit Installation
Page 22
Bottom mounting plate installation
Installation without skirting
The bottom mounting plate is fixed directly to the wall.
Installation with skirting line Knock the bottom mounting plate straight with a tool and fix it on the skirting line
Knock straight
Indoor Unit Installation
Step 3: Taking the indoor unit apart to connect the pipes
1. Open the bottom piping cover plate
Press and hold the bottom two buckles, and then rotate to open the piping
cover plate.
Refrigerant pipe
Drain-pipe Power cord NOTE: In order to drain smoothly, the position of the
drain pipe must refer to the above figure when discharging the right pipe.
Two buckles
Page 23
2. Remove the cover plate.
Remove the pipe cover plate and install the internal and external connecting
pipes.
Step 5: Drill wall hole for connective piping
1. Determine the location of the wall hole based on the location of the
outdoor unit.
2. Using a 65mm (2.5in) or 90mm(3.54in) (depending on models )core drill,
drill a hole in the wall. Make sure that the hole is drilled at a slight
downward angle, so that the outdoor end of the hole is lower than the indoor
end by about 12mm (0.5in). This will ensure proper water drainage.
3. Place the protective wall cuff in the hole. This protects the edges of the
hole and will help seal it when you finish the installation process.
NOTE: Install small-size piping first, and then large-size piping.
NOTE: All the figures in this manual are for demonstration purposes only. The
air conditioner you have purchased may be slightly different in design, though
similar in shape.
CAUTION When drilling the wall hole, make sure to avoid wires, plumbing, and
other sensitive
Wall
Outdoor
Indoor
Step 4: Network address set (some models)
(Only for the case of optional multi-function board with XYE interface.)
Every air-conditioner in network has only one network address to distinguish
each other. Address code of air-conditioner in LAN is set by code switches F1
& ENC3 on the multifunction board of the indoor unit, and the set range is
0-63. (Optional multi-function board)
12mm 0.5 inch
F1
ENC3
470mm
Indoor Unit Installation
Page 24
150mm
Recommended position and size of back outlet pipe through wall hole
Step 6: Connect drain hose
The drainpipe is used to drain water away from the unit. Improper installation
may cause unit and property damage.
CAUTION
· Insulate all piping to prevent condensation, which could lead to water
damage.
· If the drainpipe is bent or installed incorrectly, water may leak and cause
a water-level switch malfunction.
· In HEAT mode, the outdoor unit will discharge water. Ensure that the drain
hose is placed in an appropriate area to avoid water damage and slippage.
· DO NOT pull the drainpipe forcefully. This could disconnect it.
NOTE ON DRAINPIPE INSTALLATION
· When using an extended drainpipe, tighten the indoor connection with an
additional protection tube. This prevents it from pulling loose.
· The drainpipe should slope downward at a gradient of at least 1/100 to
prevent water from flowing back into the air conditioner.
· Incorrect installation could cause water to flow back into the unit and
flood.
NOTE: When connecting multiple drainpipes, install the pipes as illustrated.
NOTE ON PURCHASING PIPES Installation requires a polyethylene tube (exterior
diameter = 3.7-3.9cm, interior diameter = 3.2cm), which can be obtained at
your localhardware store or dealer.
1. Cover the drainpipe with heat insulation to prevent condensation and
leakage.
10cm (4″)
In order to ensure smooth drainage, the height difference between the wall
outlet and the hanging plate must be greater than 470mm.
2. Attach the mouth of the drain hose to the unit’s outlet pipe. Sheath the
mouth of the hose and clip it firmly with a pipe clasp.
Drain hose
470mm
Drainpipe
Pipe clasp
connecting port
Insulation
Recommended opening location of connecting pipe outlet
55
Drainage pipe fixing requirements When installing the drainage pipe (not provided ), please fix it with a tie or rope.
Indoor Unit Installation
Lean over 1/100
Page 25
Outdoor Unit Installation
Install the unit by following local codes and regulations , there may be differ slightly between different regions.
60cm (24in) above
30ocmn le(1ft2in) 200cmin (f7ro9nint)
3fr0ocmmb(1a2ciknw) all 60ocnmrig(2h4tin)
Installation Instructions Outdoor unit
Step 1: Select installation location Before installing the outdoor unit, you
must choose an appropriate location. The following are standards that will
help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Meets all spatial requirements shown in Installation Space Requirements above.
Good air circulation and ventilation
Firm and solid–the location can support the unit and will not vibrate
Noise from the unit will not disturb others
Protected from prolonged periods of direct sunlight or rain
Where snowfall is anticipated, take appropriate measures to prevent ice
buildup and coil damage.
DO NOT install unit in the following locations: Near an obstacle that will
block air inlets and outlets Near a public street, crowded areas, or where
noise from the unit will disturb others Near animals or plants that will be
harmed by hot air discharge Near any source of combustible gas In a location
that is exposed to large amounts of dust In a location exposed to a excessive
amounts of salty air
SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
If the unit is exposed to heavy wind: Install unit so that air outlet fan is
at a 90° angle to the direction of the wind. If needed, build a barrier in
front of the unit to protect it from extremely heavy winds. See Figures below.
Strong wind
Strong wind
Wind Baffle
Strong wind
If the unit is frequently exposed to heavy rain or snow: Build a shelter above
the unit to protect it from the rain or snow. Be careful not to obstruct air
flow around the unit. If the unit is frequently exposed to salty air
(seaside): Use outdoor unit that is specially designed to resist corrosion.
Outdoor Unit Installation
Page 26
Step 2: Install drain joint(Heat pump unit only) Before bolting the outdoor
unit in place, you must install the drain joint at the bottom of the unit.
Note that there are two different types of drain joints depending on the type
of outdoor unit.
If the drain joint comes with a rubber seal (see Fig. A ), do the following:
- Fit the rubber seal on the end of the drain joint
that will connect to the outdoor unit. 2. Insert the drain joint into the hole in the base
pan of the unit. 3. Rotate the drain joint 90° until it clicks in place
facing the front of the unit. 4. Connect a drain hose extension (not included)
to the drain joint to redirect water from the unit during heating mode.
If the drain joint doesn’t come with a rubber seal (see Fig. B ), do the following: 1. Insert the drain joint into the hole in the base
pan of the unit. The drain joint will click in place. 2. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during heating mode.
Step 3: Anchor outdoor unit The outdoor unit can be anchored to the ground or
to a wall-mounted bracket with bolt(M10). Prepare the installation base of the
unit according to the dimensions below. UNIT MOUNTING DIMENSIONS The following
is a list of different outdoor unit sizes and the distance between their
mounting feet. Prepare the installation base of the unit according to the
dimensions below.
Outdoor Unit Types and Specifications Split Type Outdoor Unit
H
W W
Base pan hole of outdoor unit Seal
Seal
Drain joint
(A)
(B)
IN COLD CLIMATES
In cold climates, make sure that the drain hose
D
is as vertical as possible to ensure swift water
drainage. If water drains too slowly, it can
freeze in the hose and flood the unit.
H
A B
IOnduotdooroUrnUitnit Installation
Page 27
Refrigerant Piping Connection
When connecting refrigerant piping, do not let substances or gases other than
the specified refrigerant enter the unit. The presence of other gases or
substances will lower the unit’s capacity, and can cause abnormally high
pressure in the refrigeration cycle. This can cause explosion and injury.
Note on Pipe Length
Ensure that the length of the refrigerant pipe, the number of bends, and the
drop height between the indoor and outdoor units meets the requirements shown
in the following table :
The Maximum Length And Drop Height Based on Models. (Unit: m/ft.)
Type of model
North America, Australiaand the eu frequency conversion Split
Type
Other Split Type
Capacity (Btu/h)
<15K 15K – <24K 24K – <36K 36K – 60K
12K 18K-24K 30K-36K 42K-60K
Length of piping
25/82 30/98.4 50/164 75/246 15/49 25/82 30/98.4 50/164
Maximum drop height
10/32.8 20/65.6 25/82 30/98.4
8/26 15/49 20/65.6 30/98.4
CAUTION
Mark the data plate with the Orifice installed(for some models).
Please purchase the fittings according to the requirements in the manual strictly. Refer the diagram when installing.
Indoor
Liquid side Outdoor
Indoor
Liquid side Outdoor
X
Indoor
Liquid side
Outdoor
X
Refrigerant piping Connection
Page 29
CAUTION
Oil traps If oil flows back into the outdoor unit’s compressor, this might
cause liquid compression or deterioration of oil return. Oil traps in the
rising gas piping can prevent this. An oil trap should be installed every
6m(20ft) of vertical suction line riser (36000Btu/h unit). An oil trap should
be installed every 10m(32.8ft) of vertical suction line riser (36000Btu/h
unit).
Indoor unit/ Outdoor unit
Indoor unit/ Outdoor unit
6m/20ft (36000Btu/h unit) 10m/32.8ft (36000Btu/h unit)
6m/20ft (36000Btu/h unit) 10m/32.8ft (36000Btu/h unit)
Connection Instructions Refrigerant Piping
CAUTION
· The branching pipe must be installed horizontally. An angle of more than 10°
may cause malfunction.
· DO NOT install the connecting pipe until both indoor and outdoor units have
been installed.
· Insulate both the gas and liquid piping to prevent water leakage.
Step 1: Cut pipes
When preparing refrigerant pipes, take extra care to cut and flare them
properly. This will ensure efficient operation and minimize the need for
future maintenance.
1. Measure the distance between the indoor and outdoor units.
2. Using a pipe cutter, cut the pipe a little longer than the measured
distance.
3. Make sure that the pipe is cut at a perfect 90° angle.
90°
Oblique Rough Warped
DO NOT DEFORM PIPE WHILE CUTTING
Be extra careful not to damage, dent, or deform the pipe while cutting. This
will drastically reduce the heating efficiency of the unit.
Step 2: Remove burrs. Burrs can affect the air-tight seal of refrigerant
piping connection. They must be completely removed.
1. Hold the pipe at a downward angle to prevent burrs from falling into the
pipe.
Refrigerant piping Connection
Page 30
2. Using a reamer or deburring tool, remove all burrs from the cut section of
the pipe.
Pipe Reamer
Point down
Step 3: Flare pipe ends Proper flaring is essential to achieve an airtight
seal. 1. After removing burrs from cut pipe, seal
the ends with PVC tape to prevent foreign materials from entering the pipe. 2.
Sheath the pipe with insulating material. 3. Place flare nuts on both ends of
pipe. Make sure they are facing in the right direction, because you can’t put
them on or change their direction after flaring.
Flare nut
Copper pipe
4. Remove PVC tape from ends of pipe when ready to perform flaring work.
5. Clamp flare form on the end of the pipe. The end of the pipe must extend
beyond the flare form.
Flare form
6. Place flaring tool onto the form.
7. Turn the handle of the flaring tool clockwise until the pipe is fully
flared. Flare the pipe in accordance with the dimensions.
PIPING EXTENSION BEYOND FLARE FORM
Pipe gauge
Ø 6.35 Ø 9.52 Ø 12.7 Ø 16 Ø 19 Ø 22
Tightening torque
18-20 N.m (180-200 kgf.cm)
32-39 N.m (320-390 kgf.cm)
49-59 N.m (490-590 kgf.cm)
57-71 N.m (570-710 kgf.cm)
67-101 N.m (670-1010 kgf.cm)
85-110N.m (850-1100 kgf.cm)
Flare dimension (A) (Unit: mm/Inch)
Min.
Max .
8.4/0.33 8.7/0.34
13.2/0.52 13.5/0.53
16.2/0.64 16.5/0.65
19.2/0.76 19.7/0.78
23.2/0.91 23.7/0.93
26.4/1.04 26.9/1.06
Flare shape
90 °± 4 45 °±2
A
R0.4~0.8
8. Remove the flaring tool and flare form, then inspect the end of the pipe for cracks and even flaring.
Step 4: Connect pipes
Connect the copper pipes to the indoor unit first, then connect it to the
outdoor unit. You should first connect the low-pressure pipe, then the
highpressure pipe.
1. When connecting the flare nuts, apply a thin coat of refrigeration oil to
the flared ends of the pipes.
2. Align the center of the two pipes that you will connect.
Indoor unit tubing
Flare nut
Pipe
3. Tighten the flare nut as tightly as possible by hand.
4. Using a spanner, grip the nut on the unit tubing.
Pipe
Refrigerant piping Connection
Page 31
5. While firmly gripping the nut, use a torque wrench to tighten the flare
nut according to the torque values in above table.
NOTE: Use both a spanner and a torque wrench when connecting or disconnecting
pipes to/from the unit.
6. After connecting the copper pipes to the indoor unit, wrap the power
cable, signal cable and the piping together with binding tape.
NOTE: DO NOT intertwine signal cable with other wires. While bundling these
items together, do not intertwine or cross the signal cable with any other
wiring.
7. Thread this pipeline through the wall and connect it to the outdoor unit.
8. Insulate all the piping, including the valves of the outdoor unit.
9. Open the stop valves of the outdoor unit to start the flow of the
refrigerant between the indoor and outdoor unit.
CAUTION
· Ensure to wrap insulation around the piping. Direct contact with the bare
piping may result in burns or frostbite.
· Make sure the pipe is properly connected. Over tightening may damage the
bell mouth and under tightening may lead to leakage.
C AUTION
Check to make sure there is no refrigerant leak after completing the
installation work. If there is a refrigerant leak, ventilate the area
immediately and evacuate the system (refer to the Air Evacuation section of
this manual).
NOTE: After connecting the piping, please wrap the connecting pipe head with
the insulation pipe in the accessory package
NOTE ON MINIMUM BEND RADIUS Carefully bend the tubing in the middle according to the diagram below. DO NOT bend the tubing more than 90° or more than 3 times.
Bend the pipe with thumb
min-radius 10cm (3.9″)
Refrigerant piping Connection
Page 32
Wiring
BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS
1. All wiring must comply with local and national electrical codes,
regulations and must be installed by a licensed electrician.
2. All electrical connections must be made according to the Electrical
Connection Diagram located on the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply, stop work
immediately. Explain your reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
4. Power voltage should be within 90-110% of rated voltage. Insufficient
power supply can cause malfunction, electrical shock, or fire.
5. If connecting power to fixed wiring, a surgeprotector and main power
switch should be installed.
6. If connecting power to fixed wiring, a switch or circuit breaker that
disconnects all poles and has a contact separation of at least 1/8in (3mm)
must be incorporated in the fixed wiring. The qualified technician must use an
approved circuit breaker or switch.
7. Only connect the unit to an individual branch circuit outlet. Do not
connect another appliance to that outlet.
8. Make sure to properly ground the air conditioner. 9. Every wire must be
firmly connected. Loose
wiring can cause the terminal to overheat, resulting in product malfunction
and possible fire. 10.Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts within the unit. 11.If the unit
has an auxiliary electric heater, it must be installed at least 1 meter (40in)
away from any combustible materials. 12.To avoid getting an electric shock,
never touch the electrical components soon after the power supply has been
turned off. After turning off the power, always wait 10 minutes or more before
you touch the electrical components.
13. Make sure that you do not cross your
electrical wiring with your signal wiring. This may cause distortion and
interference.
14. The unit must be connected to the
main outlet. Normally, the power supply must have a impedance of 32 ohms.
15. No other equipment should be
connected to the same power circuit.
16. Connect the outdoor wires before
connecting the indoor wires.
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO
THE SYSTEM.
NOTE ON AIR SWITCH When the maximum current of the air conditioner is more
than 16A, an air switch or leakage protection switch with protective device
shall be used(purchased seperately) . When the maximum current of the air
conditioner is less than 16A, the power cord of air conditioner shall be
equipped with plug (purchased seperately) . In North Americathe applicance
should be wired according to NEC and CEC requirements.
Air switch
(A)
(purchased seperately)
Outdoor unit power wires Indoor & Outdoor connective wires
(purchased seperately)
Outdoor unit
Indoor unit
Wiring
Page 33
(B) Indoor unit power wires
Air switch (purchased seperately)
Outdoor unit
Indoor & Outdoor connective wires (purchased seperately)
(C) Air switch (purchased seperately) Indoor unit power wires
Outdoor unit power wires
Indoor unit
Air switch (purchased seperately)
Outdoor unit
Indoor unit
Indoor & Outdoor connective wires (purchased seperately)
(D) (Only for the North American) Air switch (purchased seperately)
Outdoor unit power wires
Outdoor unit Air switch
(purchased seperately)
Indoor & Outdoor connective wires (purchased seperately)
Indoor unit
NOTE: The cographs are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail.
Outdoor Unit Wiring
WARNING
Before performing any electrical or wiring work, turn off the main power to
the system.
1. Prepare the cable for connection a. You must first choose the right cable
size. Be sure to use H07RN-F cables.
NOTE: In North America, choose the cable type according to the local electrical codes and regulations.
Minimum Cross-Sectional Area of Power and Signal Cables (For reference)
Rated Current of Appliance (A)
3 and 6 > 6 and 10 > 10 and 16 > 16 and 25 > 25 and 32 > 32 and 40
Nominal Cross-Sectional Area (mm²)
0.75 1 1.5 2.5 4 6
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable, fuse, and switch needed is
determined by the maximum current of the unit. The maximum current is
indicated on the nameplate located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse, or switch. NOTE: In North
America, please choose the right cable size according to the Minimum Circuit
Ampacity indicated on the nameplate of the unit.
b. Using wire strippers, strip the rubber jacketfrom both ends of the signal cable to reveal approximately 15cm (5.9″) of wire.
Wiring
Page 34
c. Strip the insulation from the ends. d. Using a wire crimper, crimp u-lugs
on the
ends.
NOTE: When connecting the wires, strictly follow the wiring diagram found
inside the electrical box cover.
3. Remove the electric control box Connect the u-lugs to the terminals. Match the wire colors/labels with the labels on the terminal block, Firmly screw the u-lug of each wire to its corresponding terminal. Refer to the Serial Number and Wiring Diagram located on the cover of the electric control box.
2. Remove the electric cover of the outdoor unit. If there is no cover on the
outdoor unit, take off the bolts from the maintenance board and remove the
protection board.
Cover
Electric control box
Screw
3. Connect the u-lugs to the terminals Match the wire colors/labels with the
labels on the terminal block. Firmly screw the u-lug of each wire to its
corresponding terminal.
4. Clamp down the cable with the cable clamp. 5. Insulate unused wires with
electrical tape.
Keep them away from any electrical or metal parts. 6. Reinstall the cover of
the electric control box.
Wiring diagram This wires is just for test.Please remove while installation.
NOTE: When taking out the electric control box, pay attention to loosen and
remove the terminal.
Magnetic ring (if supplied and packed with the accessories)
Pass the belt through the hole of the Magnetic ring to fix it on the cable
Indoor Unit Wiring
CAUTION
1. Prepare the cable for connection
· Illustrations in this manual are for
a. Using wire strippers, strip the rubber jacket
explanatory purposes. The actual shape
from both ends of the signal cable to reveal
shall prevail.
about 15cm (5.9″) of the wire.
· While connecting the wires, please
b. Strip the insulation from the ends of the wires. strictly follow the wiring diagram.
c. Using a wire crimper, crimp the u-lugs to the ends of the wires.
· The refrigerant circuit can become very hot. Keep the interconnection cable away from
2. Pull the left and right handles of the front panel , 5. the copper tube.
pull the panel outward, and open the panel.
4. Clamp down cable with the designated cable
clamp to secure it in place. The cable should
not be loose, and should not pull on the u-lugs.
Reinstall the electric box cover and the front panel of the indoor unit.
Wiring
Page 35
Air Evacuation
Preparations and Precautions
Air and foreign matter in the refrigerant circuit can cause abnormal rises in
pressure, which can damage the air conditioner, reduce its efficiency, and
cause injury. Use a vacuum pump and manifold gauge to evacuate the refrigerant
circuit, removing any non-condensable gas and moisture from the system.
Evacuation should be performed upon initial installation and when unit is
relocated.
BEFORE PERFORMING EVACUATION
Check to make sure the connective pipes between the indoor and outdoor units
are connected properly .
Check to make sure all wiring is connected properly.
8. If there is a change in system pressure, refer to Gas Leak Check section
for information on how to check for leaks. If there is no change in system
pressure, unscrew the cap
9. from the packed valve (high pressure valve). Insert hexagonal wrench into
the packed valve (high pressure valve) and open the valve by turning the
wrench in a 1/4 counterclockwise turn. Listen for gas to exit the system, then
close the valve after 5 seconds.
10. Watch the Pressure Gauge for one minute to make sure that there is no
change in pressure. The Pressure Gauge should read slightly higher than
atmospheric pressure.
11. Remove the charge hose from the service port.
Flare nut
Evacuation Instructions
1. Connect the charge hose of the manifold gauge to service port on the
outdoor unit’s low pressure valve.
2. Connect another charge hose from the manifold gauge to the vacuum pump.
3. Open the Low Pressure side of the manifold
gauge. Keep the High Pressure side closed. 4. Turn on the vacuum pump to
evacuate the
system. 5. Run the vacuum for at least 15 minutes, or
until the Compound Meter reads -76cmHG
(-105Pa).
Manifold Gauge
Compound gauge
Pressure gauge
-76cmHg
Low pressure valve Pressure hose /
Charge hose
High pressure valve
Charge hose Vacuum pump
Cap
valve body valve stem
12. Using hexagonal wrench, fully open both the high pressure and low
pressure valves.
13. Tighten valve caps on all three valves (service port, high pressure, low
pressure) by hand. You may tighten it further using a torque wrench if needed.
OPEN VALVE STEMS GENTLY
When opening valve stems, turn the hexagonal wrench until it hits against the
stopper. Do not try to force the valve to open further.
Low pressure valve
6. Close the Low Pressure side of the manifold gauge, and turn off the vacuum
pump.
7. Wait for 5 minutes, then check that there has been no change in system
pressure.
Air Evacuation
Page 37
Note on Adding Refrigerant
Some systems require additional charging depending on pipe lengths. The
standard pipe length varies according to local regulations. For example, in
North America, the standard pipe length is 7.5m (25′). In other areas, the
standard pipe length is 5m (16`). The refrigerant should be charged from the
service port on the outdoor unit’s low pressure valve. The additional
refrigerant to be charged can be calculated using the following formula:
Liquid Side Diameter
R22 (orifice tube in the indoor unit):
6.35(1/4″)
9.52(3/8″)
12.7(1/2″)
(Total pipe length standard pipe length)x 30g (0.32oZ)/m(ft)
(Total pipe length standard pipe length)x 65g(0.69oZ)/m(ft)
(Total pipe length standard pipe length)x 115g(1.23oZ)/m(ft)
R22 (orifice tube in the outdoor unit):
(Total pipe length standard pipe length) x15g(0.16oZ)/m(ft)
(Total pipe length standard pipe length) x30(0.32oZ)/m(ft)
(Total pipe length standard pipe length) x60g(0.64oZ)/m(ft)
R410A: (orifice tube in the indoor unit):
(Total pipe length standard pipe length) x30g(0.32oZ)/m(ft)
(Total pipe length standard pipe length) x65g(0.69oZ)/m(ft)
(Total pipe length standard pipe length) x115g(1.23oZ)/m(ft)
R410A: (orifice tube in the outdoor unit):
R32 :
(Total pipe length standard pipe length) x15g(0.16oZ)/m(ft)
(Total pipe length standard pipe length) x30g(0.32oZ)/m(ft)
(Total pipe length standard pipe length) x65g(0.69oZ)/m(ft)
(Total pipe length standard pipe length)x 12g(0.13oZ)/m(ft)
(Total pipe length standard pipe length)x 24g(0.26oZ)/m(ft)
(Total pipe length standard pipe length)x 40g(0.42oZ)/m(ft)
CAUTION DO NOT mix refrigerant types.
Only for Australia models : · This unit contains factory charged refrigerant
covering 20m of refrigerant piping and additional
refrigerant charge on the installation site is not required for an
installation with up to 20m refrigerant piping. When refrigerant piping
exceeds 20m, additionally charge an amount calculated from the pipe length and
the above table for the portion in excess of 20m. · If an existing pipe system
is used, a required refrigerant charge volume will vary depending on the
liquid pipe size. Formula to calculate the volume of additional refrigerant
required Additional charge volume (kg) = { Main length (m) Factory charged
volume 20(m) } × 0.03(kg/m) · Make sure to remove the additional refrigerant
amount according to the nameplate rated charge (under 5m refrigerant piping )
under market or government verification testing .
Air Evacuation
Page 38
Test Run
Before Test Run
A test run must be performed after the entire system has been completely
installed. Confirm the following points before performing the test:
a) Indoor and outdoor units are properly installed.
b) Piping and wiring are properly connected. c) No obstacles near the inlet
and outlet of
the unit that might cause poor performance or product malfunction. d)
Refrigeration system does not leak. e) Drainage system is unimpeded and
draining to a safe location. f) Heating insulation is properly installed. g)
Grounding wires are properly connected. h) Length of the piping and additional
refrigerant stow capacity have been recorded. i) Power voltage is the correct
voltage for the air conditioner.
CAUTION
Failure to perform the test run may result in unit damage, property damage, or
personal injury.
Test Run Instructions
1. Open both the liquid and gas stop valves. 2. Turn on the main power switch
and allow the
unit to warm up. 3. Set the air conditioner to COOL mode. 4. For the Indoor
Unit
a. Ensure the remote control and its buttons work properly.
b. Ensure the louvers move properly and can be changed using the remote
control.
c. Double check to see if the room temperature is being registered correctly.
d. Ensure the indicators on the remote control and the display panel on the
indoor unit work properly.
e. Ensure the manual buttons on the indoor unit works properly.
f. Check to see that the drainage system is unimpeded and draining smoothly.
g. Ensure there is no vibration or abnormal noise during operation.
5. For the Outdoor Unit
a. Check to see if the refrigeration system is leaking.
b. Make sure there is no vibration or abnormal noise during operation.
c. Ensure the wind, noise, and water generated by the unit do not disturb your
neighbors or pose a safety hazard.
6. Drainage Test
a. Ensure the drainpipe flows smoothly. New buildings should perform this test
before finishing the ceiling.
b. Remove the test cover. Add 2,000ml of water to the tank through the
attached tube.
c. Turn on the main power switch and run the air conditioner in COOL mode.
d. Listen to the sound of the drain pump to see if it makes any unusual
noises.
e. Check to see that the water is discharged. It may take up to one minute
before the unit begins to drain depending on the drainpipe.
f. Make sure that there are no leaks in any of the piping.
g. Stop the air conditioner. Turn off the main power switch and reinstall the
test cover.
NOTE: If the unit malfunctions or does not operate according to your
expectations, please refer to the Troubleshooting section of the Owner’s
Manual before calling customer service.
Test Run
Page 39
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>