COMMAX CDL-811P Durable Door Lock User Manual

June 17, 2024
COMMAX

COMMAX CDL-811P Durable Door Lock User Manual

CDL-811P/811R

Durable Door lock without worry about A/S
Durable body of metal
Auto lock/rewind/double lock function
Use of 3D touch and imaginary function to secure password
Password/Smart key/Fingerprint can be registered multiple
Multi-level volume control / Selectable silence function
Light button that is visible even in dark places
Emergency power function (9V square battery)
High-voltage protection/Fire protection/Anti-hack system

Intuitive registration UI
COMMAX Co., Ltd.
Thank you for purchasing COMMAX products.
Before you use, please read this manual and use correctly. COMMAX is not responsible for any safety accident due to abnormal operation of the products.

Warning Icon Due to non-key door lock, it may cause destruction of digital door lock when it is in trouble.

Warning for Safety

Warning Icon These warnings are to secure user’s safety and prevent the possible loss of property. Please read carefully below to use the product in a correct manner.

  • Do not disassemble, repair or modify the device by any unauthorized person.
  • This product is for indoor, we do not guarantee any operation at other environment.
  • Please use the product after reading User’s Manual.
  • Do not press the buttons with any tools(Ex. Awl, Pins..)
  • Change your access code from time to time for your safety.
  • Do not impact on the device.
  • Be careful that leakage or rupture may occur when inserting a battery in wrong direction.
  • Be careful that water should not seep into the device.
  • When replacing a battery, change all the batteries with new alkaline batteries.
  • Please wipe the product with soft, dry towels.
  • Please keep product warranty card for A/S.
  • Do not use this product with other purposes except digital door lock function.

Products specifications and components

FIG 1 Products specifications and components.JPG

FIG 2 Products specifications and components.JPG

*The components of the product may change depending on the installation environment.

Outdoor Names and Functions

FIG 3 Outdoor Names and Functions.JPG

FIG 4 Outdoor Names and Functions.JPG

Indoor Names and Functions

FIG 5 Indoor Names and Functions.JPG

FIG 6 Indoor Names and Functions.JPG

How to register fingerprint

FIG 7 How to register fingerprint.JPG

FIG 8 How to register fingerprint.JPG

How to register and change password

FIG 9 How to register and change password.JPG

FIG 10 How to register and change password.JPG

How to register Smart key

FIG 11 How to register Smart key.JPG

FIG 12 How to register Smart key.JPG

How to register the linker (optional)

FIG 13 How to register the linker.JPG

Reference

1. You can register up to 5 interlocks.
2. Repeat step 3 when registering the linker.

How to delete fingerprint, smart key, linker

FIG 14 How to delete fingerprint, smart key,
linker.JPG

How to set auto lock, manual lock

FIG 15 How to set auto lock, manual lock.JPG

How to set and dismiss 3D touch

FIG 16 How to set and dismiss 3D touch.JPG

Reference
1. It is a function to strengthen the security of password and it is a function to set a virtual number instead of the original number when the password is registered and authenticated for more than 1 second. Ex) When 1 is long pressed: It is recognized as a virtual number other than 1.
2. Combined with the imaginary function of this product, password security is further strengthened.
3. You can set each number and you can check that the lamp blinks when you press for more than 1 second.
4. 3D touch mode is turned off at the factory.

Cautions
1. When the 3D touch mode is released, the password is reset to “1234”.
2. In case of master registration / deletion, fire / accident, etc., it is recognized as normal number mode.

Open the door in outdoor

FIG 17 Open the door in outdoor.JPG

FIG 18 Open the door in outdoor.JPG

Door locking in indoor and outdoor

FIG 19 Door locking in indoor and outdoor.JPG

Reference
1. When you press [double lock] button in manual lock mode, you will hear a “beep” buzzer sound when the door is locked and inform you that the door is lockedv.

Internal double lock setting

It is a function that can not open a door with a password or a smart key outside the door.

FIG 20 Internal double lock setting.JPG

Dual authentication / Registration authentication setting

FIG 22 Dual authentication.JPG

Reference
1. If dual authentication mode is activated, Password + Card should be confirmed to open to door.
2. If registration authentication mode is activated, first authentication by existing password should be done for the next step.

  • No dual authentication is activated if factory setting.
  • Registration authentication is activated if factory setting.
  • To deactivate dual authentication / registration authentication, repeat the same procedure for activation

BURGLAR ALERT

FIG 23 BURGLAR ALERT.JPG

Volume Adjustment

FIG 24 Volume Adjustment.JPG

Reference

1. Available total 8 levels of volume sound
2. If sound pause mode, numbers are only flicking without sound

BATTERY REPLACEMENT ALERT

If battery alert light is on on number plate or beep sounds ring, battery has to be replaced. All batteries must be replaced with new one at once.

FIG 25 BATTERY REPLACEMENT ALERT.JPG

Caution

1. Lifetime of battery can be varied according to manufacturers, date of production, working condition. (Expected lifetime : 10 months assuming no wireless operation, AA type alkaline 8ea, 10 times per one day use)
2. If battery liquid leaks out, product can be damaged. Regular checking is recommended – every 6 months.
3. Battery lifetime might be shortened if wireless module is activated.

Sound Pause Mode

Temporary silence function (1 time) regardless latest volume setting

FIG 26 Sound Pause Mode.JPG

High Temperture Alarm

FIG 27 High Temperture Alarm.JPG

Emergency Power

When door can not be opened due to fully discharged battery.

1. Contact the terminals of 9V battery to emergency power outlet Press [Password] and [ * ] to open the door while contacting terminals of 9V battery to emergency power outlet.

FIG 28 Emergency Power.JPG

Emergency Key

When door is not opened due to malfunction.

FIG 29 Emergency Key.JPG

Caution

  1. Your mechanical key is recommended to be stored outside of the door for emergency use.

Factory Reset Mode

FIG 30 Factory Reset Mode.JPG

Anti-mischief alert and 1 minute pause

If unregistered [password], [smartkey], [fingerprint] keeps used more than 5 times continuously, freeze operation for 1 minute with alert sound.

FIG 31 Anti-mischief alert and 1 minute pause.JPG

Deadbolt Jam alert

FIG 32 Deadbolt Jam alert.JPG

FIG 33 Deadbolt Jam alert.JPG

FIG 34 Deadbolt Jam alert.JPG

Summary of how to use

FIG 35 Summary of how to use.JPG

FIG 36 Summary of how to use.JPG

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

COMMAX User Manuals

Related Manuals