COMMAX CDL-811P Durable Door Lock User Manual
- June 17, 2024
- COMMAX
Table of Contents
- COMMAX CDL-811P Durable Door Lock User Manual
- Warning for Safety
- Products specifications and components
- Outdoor Names and Functions
- Indoor Names and Functions
- How to register fingerprint
- How to register and change password
- How to register Smart key
- How to register the linker (optional)
- How to delete fingerprint, smart key, linker
- How to set auto lock, manual lock
- How to set and dismiss 3D touch
- Open the door in outdoor
- Door locking in indoor and outdoor
- Internal double lock setting
- Dual authentication / Registration authentication setting
- BURGLAR ALERT
- Volume Adjustment
- BATTERY REPLACEMENT ALERT
- Sound Pause Mode
- High Temperture Alarm
- Emergency Power
- Emergency Key
- Factory Reset Mode
- Anti-mischief alert and 1 minute pause
- Deadbolt Jam alert
- Summary of how to use
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
COMMAX CDL-811P Durable Door Lock User Manual
CDL-811P/811R
Durable Door lock without worry about A/S
Durable body of metal
Auto lock/rewind/double lock function
Use of 3D touch and imaginary function to secure password
Password/Smart key/Fingerprint can be registered multiple
Multi-level volume control / Selectable silence function
Light button that is visible even in dark places
Emergency power function (9V square battery)
High-voltage protection/Fire protection/Anti-hack system
Intuitive registration UI
COMMAX Co., Ltd.
Thank you for purchasing COMMAX products.
Before you use, please read this manual and use correctly. COMMAX is not
responsible for any safety accident due to abnormal operation of the products.
Due to non-key door lock, it may cause destruction of digital door lock when it is in trouble.
Warning for Safety
These warnings are to secure user’s safety and prevent the possible loss of property. Please read carefully below to use the product in a correct manner.
- Do not disassemble, repair or modify the device by any unauthorized person.
- This product is for indoor, we do not guarantee any operation at other environment.
- Please use the product after reading User’s Manual.
- Do not press the buttons with any tools(Ex. Awl, Pins..)
- Change your access code from time to time for your safety.
- Do not impact on the device.
- Be careful that leakage or rupture may occur when inserting a battery in wrong direction.
- Be careful that water should not seep into the device.
- When replacing a battery, change all the batteries with new alkaline batteries.
- Please wipe the product with soft, dry towels.
- Please keep product warranty card for A/S.
- Do not use this product with other purposes except digital door lock function.
Products specifications and components
*The components of the product may change depending on the installation environment.
Outdoor Names and Functions
Indoor Names and Functions
How to register fingerprint
How to register and change password
How to register Smart key
How to register the linker (optional)
Reference
1. You can register up to 5 interlocks.
2. Repeat step 3 when registering the linker.
How to delete fingerprint, smart key, linker
How to set auto lock, manual lock
How to set and dismiss 3D touch
Reference
1. It is a function to strengthen the security of password and it is a
function to set a virtual number instead of the original number when the
password is registered and authenticated for more than 1 second. Ex) When 1 is
long pressed: It is recognized as a virtual number other than 1.
2. Combined with the imaginary function of this product, password security is
further strengthened.
3. You can set each number and you can check that the lamp blinks when you
press for more than 1 second.
4. 3D touch mode is turned off at the factory.
Cautions
1. When the 3D touch mode is released, the password is reset to “1234”.
2. In case of master registration / deletion, fire / accident, etc., it is
recognized as normal number mode.
Open the door in outdoor
Door locking in indoor and outdoor
Reference
1. When you press [double lock] button in manual lock mode, you will hear a
“beep” buzzer sound when the door is locked and inform you that the door is
lockedv.
Internal double lock setting
It is a function that can not open a door with a password or a smart key outside the door.
Dual authentication / Registration authentication setting
Reference
1. If dual authentication mode is activated, Password + Card should be
confirmed to open to door.
2. If registration authentication mode is activated, first authentication by
existing password should be done for the next step.
- No dual authentication is activated if factory setting.
- Registration authentication is activated if factory setting.
- To deactivate dual authentication / registration authentication, repeat the same procedure for activation
BURGLAR ALERT
Volume Adjustment
Reference
1. Available total 8 levels of volume sound
2. If sound pause mode, numbers are only flicking without sound
BATTERY REPLACEMENT ALERT
If battery alert light is on on number plate or beep sounds ring, battery has to be replaced. All batteries must be replaced with new one at once.
Caution
1. Lifetime of battery can be varied according to manufacturers, date of
production, working condition. (Expected lifetime : 10 months assuming no
wireless operation, AA type alkaline 8ea, 10 times per one day use)
2. If battery liquid leaks out, product can be damaged. Regular checking is
recommended – every 6 months.
3. Battery lifetime might be shortened if wireless module is activated.
Sound Pause Mode
Temporary silence function (1 time) regardless latest volume setting
High Temperture Alarm
Emergency Power
When door can not be opened due to fully discharged battery.
1. Contact the terminals of 9V battery to emergency power outlet Press [Password] and [ * ] to open the door while contacting terminals of 9V battery to emergency power outlet.
Emergency Key
When door is not opened due to malfunction.
Caution
- Your mechanical key is recommended to be stored outside of the door for emergency use.
Factory Reset Mode
Anti-mischief alert and 1 minute pause
If unregistered [password], [smartkey], [fingerprint] keeps used more than 5 times continuously, freeze operation for 1 minute with alert sound.
Deadbolt Jam alert
Summary of how to use