Part Names.

COMMAX DRC-4PIP Color Door Camera - Fig 1※ During a camera call/talk, the LED (BLUE) on the call button lights up

Package contents

COMMAX DRC-4PIP Color Door Camera - Fig 2

Wiring and Installation

COMMAX DRC-4PIP Color Door Camera - Fig 3

  1. Match the fix the whole in the wall and the fixing bracket [FIG.1]
  2. Match and connect monitor line as shown below [FIG.2] (#1: Voice, #2: GND, #3: DC12V, #4: Video)
  3. Adjust camera location on the wall by checking the image on monitor screen and fix its location
  4. Connect the Door Release Connection Line as shown below [FIG.2] (#5: Open1, #6: Open2)
    ● You can adjust speaker volume using driver as shown below.
    ● After adjusting the volume, use the ‘SHEET VOLUME’ included in the accessory to close the hole before installing.

COMMAX DRC-4PIP Color Door Camera - Fig 4

Specification

Model No. DRC-4PIP
Rated Voltage 12V ****(Supplied from monitor)
Wiring 4 wires(polarity)to a monitor

2 wires(non-polarity)to a electric door lock
Video Transmission Standard| NTSC or PAL STANDARD.
Sensor Type| C-MOS (COLOR) – CVBS
Transmission| Simultaneous communication
Minimum Illumination| 0.1 Lux(within300mm)
LED| Embedded IR LED(Night working)
Effective Viewing Angle| 136° (D)
Operating Temperature| -30°C–+50°C
Dimension (mm)| 50(W) X 135(H) X 23(D)
Distance between a door camera and monitor| Diameter(pie)| Ø0.5| Ø0.65| Ø0.8| 1
Distance(meter)| 28m| 50m| 70m| 115m

※ IR LED operates in low light conditions.
In this case, the image may be displayed in black and white.
※ This product can be used for door lock systems that use DC power.
(Max. switching voltage and current : 2A 30V DC)

COMMAX logo 1513-11, Sangdaewon-dong,
Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
Int’l Business Dept.
: Tel.; +82-31-7393-540~550
Fax.; +82-31-745-2133
Web site : www.commax.com
Edited.2021.12.28

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals