COMMAX CDL-100WL Digital Lever Lock Biometric Fingerprint User Manual

June 13, 2024
COMMAX

COMMAX-LOGO

COMMAX CDL-100WL Digital Lever Lock Biometric Fingerprint

Product Information

  • Product Name: COMMAX CDL-100WL (Smart Key) and CDL-800WL (Fingerprint)
  • Manufacturer: COMMAX Co.Ltd.

Product Specifications:

  • Division: Normal wooden door (Thickness 35mm~55mm)
  • Password: 4~12 digit number (up to 4 passwords available)
  • Access methods:
    • Smart Key (CDL-100WL): Up to 30 smart keys available
    • Fingerprint (CDL-800WL): Up to 100 fingerprints available
  • Power Source: DC 6V
  • Batteries: LR6 1.5V AA Alkaline batteries (4ea)
  • Emergency Power: DC 9V Auxiliary battery or Alkaline battery (optional) MICRO USB 5PIN
  • Material:
    • Out body: AL, ZN, ABS, PC
    • In body: AL, ZN, ABS, PC
  • Type of product:
    • CDL-100WL: Smart Key, Anti-fireproof type, Non-key type, Master key door lock
    • CDL-800WL: Fingerprint, Anti-fireproof type, Non-key type,Master key door lock

Product Usage Instructions

Main Parts and Functions (Outside)

No. Name Feature
1 Outdoor handle and plate number Able to enter numbers when

registering/changing access code.
Use to open/close the door from outside. Input for smart key
(CDL-100WL) or fingerprints (CDL-800WL).
2| CDL-100WL with the registered smart keys / CDL-800WL with the
registered fingerprints| Able to register smart keys (CDL-100WL) or fingerprints
(CDL-800WL) and open the door.
3| Door open indicator| Able to check whether the door is opened (CDL-800WL).
4| [Start] button| Makes LED on the number plate turn on.
5| Emergency Power Terminal| Contact a 9V battery to the emergency power terminal when the
batteries run out completely.
6| Micro USB 5PIN| Contact an auxiliary battery to the emergency power terminal
when the batteries run out completely.

Main Parts and Functions (Inside)

No. Name Feature
1 Battery Cover Cover to protect the battery and [Registration] button.
2 [Registration] Button To register/change smart key, fingerprint, or access

code.
3| Double Lock Button| To lock the door and make it locked from the outside, such as
at night time.
4| Inner Handle| To open/close the door from inside.

How to Register Your Password

  1. Be sure to register your password with the door open.
  2. Press the [Register] button on the main parts (Outside).
  3. Open the battery cover inside the main part and press the [Register] button.
  4. Enter a new password (4~12 digits) and press the [] button.
    You will hear a beep sound, and the registration is done. Pressing the [
    ] button again will terminate the registration.

Note:

  1. You may repeat step 3 before the lamp on the [number plate] goes out.
  2. You can register up to 4 passwords.

Warning:

  1. By registering a new password, the existing password will be automatically deleted.
  2. Do not use consecutive numbers for your password.

COMMAX Co.Ltd.,
Thank you for purchasing COMMAX products.
Please carefully read this User’s Manual(in particular, precautions for safety) before using a product and follow instructions to use it correctly. The company is not responsible for any safety accidents caused by abnormal operation of the product.

Due to non-key door lock, it may cause destruction of digital door lock when it is in trouble.

Warning for Safety

These warnings are to secure user’s safety and prevent the possible loss of property. Please read carefully below to use the product in a correct manner.

  • Do not disassemble, repair or modify the device by any unauthorized person.
  • This product is for indoor, we do not guarantee any operation at other environment.
  • Please use the product after reading User’s Manual.
  • Do not press the buttons with any tools(Ex. Awl, Pins..)
  • Change your password from time to time for your safety.
  • Do not impact on the device.
  • Be careful that leakage or rupture may occur when inserting a battery in wrong direction.
  • Be careful that water should not seep into the device.
  • When replacing a battery, change all the batteries with new alkaline batteries.
  • Please wipe the product with soft, dry towels.
  • Do not use this product with other purposes except digital door lock function.

Product Specifications

Division Contents
Applicable Normal wooden door Thickness 35mm~55mm

Access methods

| Password| 4~12digit nember(up to 4 password available)
Smart Key(CDL-100WL)| Up to 30 smart keys available
Fingerprint (CDL-800WL)| Up to 100 fingerprints available
Power Source| DC 6V| LR6 1.5V AA Alkaline batteries(4ea)
Emergency Power| DC 9V| Alkaline battery(optional)
Auxiliary battery| MICRO USB 5PIN
Temperature Alarm| Temperature sensor| 60‘C ± 10’C
Material| Out body| AL,ZN,ABS,PC
In body| AL,ZN,ABS,PC
Type of product| CDL-100WL(Smart Key, Anti-fireproof type, Non-key type, Master key door lock)
CDL-800WL(Fingerprtint, Anti-fireproof type, Non-key type, Master key door lock)

COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-
Fingerprint-1

Components of the product may be changed depending on installation environment.

Main Parts and Functions

Main Parts and Functions (Outside)

No. Name Feature
1 Outdoor handle and number plate Able **to

enter numbers when registering/changing access code.**

Use to open/close the door from outside

2

| Input for smart key

(CDL- 100WL)

| Able to register smart keys and open the door

with the register smart keys

Input for fingerprints

(CDL- 800WL)

| Able to register fingerprints and open the door

with the register fingerprints

3| Door open indicator| Able to check whether the door is opened(CDL-

800WL)

4| [Start] button| Make Led on nember plate to be turned on.
5| Emergency Power Teminal| When the batteries run out comlpetely, please contact the 9v battery to emergency power

terminal and the power will be on

6| Micro USB 5PIN| When the batteries run out comlpetely, please contact the auxilliary battery to emergency power

terminal and the power will be on

Main Parts and Functions (Inside)

No. Name Feature
1 Battery Cover Cover to protect battery and [Registration] button
2 [Registration] Button To register/change smart key, fingerprint or

access code

3| Double Lock Button| To lock the door and make it locked from the

ouside such as at night time

4| Inner Handle| To open/close the door at inside

How to Register Your Password

Be sure to register your password with the door open.

  1. Press [Register] button.

  2. Press [1] on the main parts (Outside)
    Open the battery cover inside of the main part and press [Register] button.

  3. Enter new password
    After entering new password(4~12digits), press [] button. You will hear beep sound and registration is done.
    Once you press the [
    ] button again, registration will be terminated.

Note

  1. You may repeat step 3. before the lamp on [number plate] goes out.
  2. You can register up to 4 passwords.

Warning

  1. By registering a new password, the existing password will automatically deleted.
  2. Do not use consecutive number for your password.

How to Register Your Smart Key(CDL-100WL)

When registering or re-registering a smart key, you must register all your keys together. Other smart key or transportation card will not be registered. Also, registered smart keys are for digital door lock only. It may not operate to other products.

  1. Press [Register] button. Beep Open the battery cover inside of the main part and press [Register] button.
  2. Press [2] on the main parts (Outside)
  3. Tag smart key to smart key input section.
    Each time you tag the smart keys, you will hear a confirmation tone and be registered.
    Press the [Register] button on the indoor body to complete the registration.

Note

  1. You may repeat step 3. before the lamp on [number plate] goes out.
  2. You can register up to 30 smart keys.

Warning

  1. By registering a new password, the existing password will automatically deleted.

How to Delete Your Smart Key(CDL-100WL)

  1. Press [Register] button
    Open the battery cover inside of the main part and press [Register] button.

  2. Press [5] on the main parts

  3. Press [*] on the main parts for 5 sec. (Outside)

All the registered smart keys will be deleted with confirmation tone after you press [*] button for 5 seconds

How to Register Your Fingerprint(CDL-800WL)

  1. Press [Register] button

Open the battery cover inside of the main part and press [Register] button.

  1. Press [2] on the main parts (Outside)
  2. Register new fingerprint

After tagging your registering fingerprint 4 times, press [Register] button to complete registration.

NOTE

  1. You can register up to 100 fingerprints.
  2. During the registration, it will be terminated if there are no any inputs for 20 seconds.

How to Delete Your Fingerprint(CDL-800WL)

  1. Press [Register] button.

Open the battery cover inside of the main part and press [Register] button.

  1. Press [5] on the main parts (Outside)
  2. Press [*] on the main parts for 5 sec. (Outside)

All the registered fingerprints will be deleted with confirmation tone after you press [*] button for 5 seconds.

How to Unlock from Outside(password)

  1. Press [Start] button.
    COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-
Fingerprint-16
    Press [Start] button from the outdoor handle.

  2. Enter your password Enter registered password when LED light is on.

  3. Press [*] button

When you press the button, the door will be opened with confirmation tone.

Setting for Auto/Manual Lock

Set Auto/Manual mode by switching slide inside of the indoor product.

  • A: Automation Lock
  • M: Manual Lock

COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-
Fingerprint-15

How to Lock from Indoor

  1. When Auto lock is set
    The door will be locked after the door open state is maintained for 7 sec. with password/fingerprint.

  2. When Manual lock is set
    The door will be locked after you press [dual lock] button at indoor.

How to Lock from Outdoor

  1. When Auto lock is set
    The door will be locked after the door open state is maintained for 7 sec. with password/fingerprint.

  2. When Manual lock is set
    The door will be locked after you press [Start] button 2 seconds inside of the outdoor handle.

How to Set Dual Lock Function

This function is to prevent the door opening even with a password or fingerprint from outside the door.

  1. How to set dual lock function Press [Dual Lock] button for 3 seconds from inside while the door is locked. And setting is done with the confirmation tone.

Note

  1. When dual lock is set,5 buttons on number plate will be illuminated.

How to Delete Dual Lock Function

  1. Deleting from inside door
    Press [Dual Lock] button from inside door to delete dual lock function.

  2. Deleting from outside doorCOMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-Fingerprint-20COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-Fingerprint-21

  3. Beep
    Press [Start] button from outside door.

  4. Enter password

  5. Beep
    Press [Start] button from outside door.
    Press [0] to delete dual lock function.

Converting the directions of handle

  1. Press [Register] button.

Open the battery cover inside of the main part and press [Register] button.

  1. Press [Start] button.
    COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-
Fingerprint-16
    Press [Start] button from the outdoor handle.

  2. Press [Register] button.
    Open the battery cover of the indoor main part and press [Register] button, and directions of handle will be changed.

Note

  1. If the number plate on the outside handle is turned upside down after installation,change the setting as described above.

How to Register/Delete 3D Touch

  1. Press [Start] button.COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-Fingerprint-16
    Beep Press [Start] button from the outdoor handle.

  2. Enter password. Enter registered password when LED light is on.

  3. Press [Start] button.COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-Fingerprint-23
    Beep Press [start] button 2 times
    Press [Start] button twice in a row, press [0] and open the battery cover of the indoor main part and press [Register] button, and 3D touch setting/delete will be changed.

  4. Setting alarm : Beeeeeep

  5. Delete alarm : Beep

Note

  1. It is to strengthen the security of password.
    When registering/ authentication a password, pressing the number for a second or longer will set the number to a virtual number instead of the original number.
    (Ex. When you press [1] for a long time : it indicates virtual number, not 1.)

  2. Combined with the imaginary function of this product, password security will be much strengthened.

  3. You can set each number and check by the blinking of the lamp when you press the button more than a second. 4. 3D Touch mode is not set when it is in factory reset mode.

What is imaginary function?
Function to open a door even if random number is entered with the actual password.
Ex) Password “1234”
Enter imaginary and password – 5231234, 1234253, 45123402
Even entered as above, the door opens

Warning

  1. When 3D touch mode is deleted, the password is reset to ‘1234’.
  2. Recognized as normal number mode in case of master registration/deletion, fire/mischief.

Alarm Alert for Battery Replacement

When warning light is on the number plate after operation or if you hear ‘Beep, Beep, Beep’ sounds, you need to change the battery. At this time,you need to replace all the batteries for new one

Warning

  1. The battery life may vary depending on the manufacturer, date of manufacture, and usage environment.
    (Wireless interlock module not used,AA type alkaline batteries*4EA, 10 times a day basis of use can be used more than 10 months.)

  2. If battery leakage occurs, the product may be damaged. Please check it regularly (apporx. Every 6 months.)

To Register/Delete Multi-layered

  1. Press [Start] button.
    COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-
Fingerprint-16
    Press [Start] button from the outdoor handle.

  2. Enter password.
    Enter registered password when LED light is on.

  3. Press [Start] button 2 times
    COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-
Fingerprint-25
    Press [start] button 2 times
    Press [Start] button twice in a row, press [4] and open the battery cover of the indoor main part and press [Register] button, and multi-layered authentication setting/delete will be changed.

  4. Setting alarm : Beeeeeep

  5. Delete alarm : Beep

NOTE

  1. When Multi-layered Authentication mode is set,you can open the door after password + card/password + fingerprint authentication. *Multi-layered authentication mode is not set when it is in factory reset mode.
    Multi-layered authentication mode is deleted when you set in same way of registration.

Setting/Deleting Register Authentication

  1. Press [Start] button.COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-Fingerprint-16
  2. Enter password.
  3. Press [Start] button.COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-Fingerprint-26

Press [Start] button twice in a row, press [5] and open the battery cover of the indoor main part and press [Register] button, and 3D touch setting/delete will be changed.

  • Setting alarm : Beeeeeep
  • Delete alarm : Beep

NOTE

  1. When Register Authentication mode is set, you need to authenticate with existing password to use registration mode.
    • Register Authentication mode not set when it is in factory reset mode.
    • Register authentication mode is deleted when you set in same way of registration.

Sounds Control

  1. Press [Start] button.
  2. Enter password.
  3. After you press [start] button, change the volume with [1] and [3] buttons.

COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-
Fingerprint-27

Press [1] to decease the volume.
Press [3] to increase the volume

NOTE

  1. You can set the sound volume in 8 different stages.
  2. Under the temporary pause mode, the lamp on keypad will keep blinking when you push the buttons.

Setting the sound temporary pause

You can set the sound temporary pause at once whatever you have set the sound volume.

Settings

  1. Press [Start] button on outer body 2times
    After pressing password, press [*] button

  2. Press [Start] button on outer body 2times
    Contact [fingerprint] or [smart key] to unlock the door

Note
This is for only once, you will hear the operating sound afterwards.

High-Temperature Detection

If the high-temperature (60℃±10℃) is detected, it unlock the door automatically with warning sounds for safety.

Emergency Power

If you can’t open the door when the batteries run out completely,

  1. Contact 9V battery to terminal of outer body.
    While contacting 9V battery to terminal of outer body, press password + [*] and the door will be unlocked.

  2. Connect auxiliary battery to terminal of outer body.(Micro USB 5 pin) While contacting auxiliary battery(Micro USB 5 pin) to terminal of outer body, press password + [*] and the door will be unlocked.

Factory Reset Mode

  1. Press [Register] button for 5 sec.

Open the battery cover inside of the main part and press [Register] button for 5 sec.

  1. When all the lamp on [number plate] is on, enter “01234543210”.
  2. Press [Start] button on outer handle for 2 sec.COMMAX-CDL-100WL-Digital-Lever-Lock-Biometric-Fingerprint-16
    Factory reset mode is on with the confirmation tone when you press [start] button for 2 sec.

Warning

  1. All the setting goes default after the factory reset mode.

Note Settings for Factory Reset Mode

  • password : [1][2][3][4]
  • Sound setting : High
  • Multi-layered authentication mode : Off
  • Register authentication mode : Off
  • 3D Touch mode : Off
  • Direction of handle(left/right) : Right

Self-checking list

You can see the status of the door lock by checking the flashing number on the number plate.

Operation Self-Checking List
LED 1 ON FLASH None
LED 2 ON FLASH – Error on access code, fingerprint RF card registreation /

delete (duplicate registration)

–   Not registered password, fingerprint, RF card

LED 3 ON FLASH| Number of fingerprint/password registered is full.
LED 4 ON FLASH| Fire alarm
LED 5 ON FLASH| Duplicate lock inside
LED 0 ON FLASH| Trouble with fingerprint module
ALL NUMBERS ON FLASH| Trouble with deadbolt

Summary of how to use

Function| Default|
---|---|---
Password registration/change| 1234| [Registration] ⇒ [1] ⇒ Password to register ⇒ [] ⇒ []
Fingerprint registration(CDL-800WL)| | [Registration] ⇒ [2] ⇒ Fingerprint registration 4 time ⇒ [Registration]
Delete all fingerprints(CDL-800WL)| | [Registration] ⇒ [5] ⇒ [] button More than 5 seconds
Smart key registration(CDL-100WL)| | [Registration] ⇒ [2] ⇒ Contact Smart key
Delete allSmart key(CDL-100WL)| | [Registration] ⇒ [5] ⇒ [
] button More than 5 seconds
Open the door indoors| | Interior side handle operation
Close the door indoors| | Manual Locking: Press the [Internal Dual Locking] button
| Auto lock: Auto lock will be after 7seconds
Open the door outdoors| | Password : [Start] ⇒ LED ON ⇒ password ⇒ [*]
Close the door outdoors| | Auto lock: Auto lock will be after 7seconds
Manual lock : Push the [Start] button 2 seconds
Left/Right direction conversion function| Right| [Registration] ⇒ [Start] ⇒ [Registration]
Internal force lock setting| | Press and hold the [Internal force lock] button for 3 seconds

Release internal force lock

| | Indoors: manual opening and closing with door open and door

closing

Outdoors : [Start] ⇒ password ⇒ [Start] ⇒ [0]

Etiquette mode function

| | password : [Start] 2times ⇒ password ⇒ [*]
fingerprint, smart card : [Start] 2times ⇒ contact fingerprint,smart

key

Buzzer volume setting| | Treble :[Start] ⇒ password ⇒ [Start] ⇒ [1] ⇒ []
Bass : [Start] ⇒ password ⇒ [Start] ⇒[3] ⇒ [
]
Set dual authenitication mode| Release| [Start] ⇒ password ⇒ [Start] 2times ⇒ [4] ⇒ [Registration]
Set registration authenitication mode| Release| [Start] ⇒ password ⇒ [Start] 2times ⇒ [5] ⇒ [Registration]
3D touch enhanced| Release| [Start] ⇒ password ⇒ [Start] 2times ⇒ [0] ⇒ [Registration]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

COMMAX User Manuals

Related Manuals