COMMAX CDL-400M Durable Door lock User Manual

June 17, 2024
COMMAX

CDL-400M/410M/400MC/410MC
USER MANUAL

CDL-400M Durable Door lock

COMMAX CDL-400M Durable Door lock

Durable Door lock without worry about A/S
Durable body of metal
Auto lock/rewind/double lock function
Use of 3D touch and imaginary function to secure password
Password/Smart key can be registered multiple
Multi-level volume control / Selectable silence function
Light button that is visible even in dark places
Emergency power function (9V square battery)
High-voltage protection/Fire protection/Anti-hack system
Intuitive registration UI
COMMAX Co., Ltd.

Thank you for purchasing COMMAX products.
Before you use, please read this manual and use correctly. COMMAX is not responsible for any safety accident due to abnormal operation of the products.

**** Due to non-key door lock, it may cause destruction of digital door lock when it is in trouble.

Warning for Safety

These warnings are to secure user’s safety and prevent the possible loss of property.
Please read carefully below to use the product in a correct manner.

  • Do not disassemble, repair or modify the device by any unauthorized person.
  • This product is for indoor, we do not guarantee any operation at other environment.
  • Please use the product after reading User’s Manual.
  • Do not press the buttons with any tools(Ex. Awl, Pins..)
  • Change your access code from time to time for your safety.
  • Do not impact on the device.
  • Be careful that leakage or rupture may occur when inserting a battery in wrong direction.
  • Be careful that water should not seep into the device.
  • When replacing a battery, change all the batteries with new alkaline batteries.
  • Please wipe the product with soft, dry towels.
  • Please keep product warranty card for A/S.
  • Do not use this product with other purposes except digital door lock function.

Products specifications and components

Sort Specifications
Opening method Passw ord 4-12 digits (Up to 4 can be registered)
RF key It can register w ithin 30
Wallpad interlock CDL-400MC/410MC ONLY
Rated voltage DC 6V LR6 1.5V AA sized alkaline batteries 4
Emergency pow er DC 9V Alkaline batteries 8 (Separate purchase)
Type of product Temperature-sensitive form, Non-KEY, Primary keylock /

NF-T-NK-M)
High temperature sensing| Temperature sensor type| 60+-10 dgrees
Material| Out body| AL,ZN,ABS,PC
In body| AL,ZN,ABS,PC
Sort| Using frequency| Number of channels| Modulation format| Antenna power
---|---|---|---|---
RFID| 13.56Mhz| 1| ASK| 93.5dBu/under m@ 10m
Wireless devices for afety systems (optional)| 447.275Mhz| 1| FSK| 10mW/under

COMMAX CDL-400M Durable Door lock - Products specifications and
components

*The components of the product may change depending on the installation environment.

Outdoor Names and Functions

No Name Specifications
1 Name board Enter the number when registering or changing password.
2 Battery warning light Turns on with an audible alarm at low voltage.
3 Smart key input unit It is the place where smart keys are recognized to

open the door. You can open the door by registering the smart key or touching the registered smart key.
4| Outdoor handle| It is Used to open or close doors from outdoors.
5| Emergency power terminal| In case the battery is completely discharged, you can use 9V battery then, the power will be on.

COMMAX CDL-400M Durable Door lock - Outdoor Names and
Functions

Indoor Names and Functions

No Name Specifications
1 Battery cover This cover protects the batteries and the registration

button.
2| Registration button| It is used to register or change password or smart key
3| Mortise| It is attached to the side of the door and closes or locks the door.
4| Dead bolt (Square locking type)| It locks the door by locking it on the door frame.
5| Latch bolt| It serves to keep the door shaken
6| Alkalina AA battery| It is a power source that operates the door lock.
7| Double lock button| It can be used to lock the door so that it can not be opened outside,such as during nighttime hours that require attention.
8| Indoor handle| It is used to open or close the door indoors.

COMMAX CDL-400M Durable Door lock - Indoor Names and
Functions

How to register and change password

**** Be sure to register your password with the door open.

  1. Press [registration] button Open the battery cover and press [registration] button
  2. Press [1]button in the number plate of outdoor side
  3. Enter new password After entering the new password(4~12 digits), press button and the confirmation tone sounds and registration is completed. Press the button once more to end registration.

Reference

  1. When adding the password, repeat the above item 3 before the number plate lamp turns off.
  2. Up to 4 password can be registered

Cautions

  1. If you register a new password, the existing password will be automatically deleted.
  2. Do not use consecutive numbers when registering your password.

How to register Smart key

**** When registering or re-registering a smart key, you must register all the smart keys you have at once. Also registered smart keys are door lock only. It may not work when used with other products.

  1. Press [registration] button Open the battery cover and press [registration] button
  2. Press [2] button in the number plate of outdoor side
  3. Contact smart key to smart key input unitCOMMAX CDL-400M Durable Door lock - smart key input unitIf you touch the smart key to be registered one by one, you will hear a confirmation sound every time you touch it.
    Registration is completed by clicking the [Registration] button on the indoor side body.

Reference

  1. When adding the password, please repeat the above item 3 before the [License plate lamp] turns off.
  2. Up to 30 smart keys can be registered.

Cautions

  1. When registering a new smart key, the existing smart key is automatically deleted.

How to register the linker (CDL-400MC/410MC only)

  1. Press [registration] button Open the battery cover and press [registration] button
  2. Press [3]button in the number plate of outdoor side
  3. Press the [Register] or [OP / CL] button on the linker
    After pressing the front door button of the wall pad (video phone), press the [Registration] or [OP / CL] button of the interlocker when the standby mode is canceled.

Reference

  1. You can register up to 5 interlocks.
  2. Repeat step 3 when registering the linker.

How to delete Smart key, Linker

  1. Press [registration] button Open the battery cover and press [registration] button

  2. Press number in the number plate
    – Smart key deletion: No 7 button
    – Deleting the interlock: No 8 button

  3. Press # button Press and hold the [#] button for 5 seconds to delete the registered smart key or interlock.

How to set auto lock, manual lock

**** Make sure to turn off the Mortise Square Lock on the indoor body.

  1. Enter password Touch the outdoor license plate to turn on the LED and enter the registered password.
  2. Press [#] button Press the [#] button twice in succession
  3. Press [4] or [7] button and press registration button Auto lock setting: Press the [4] button and press the register button to set the auto lock function after a confirmation tone sounds. Manual lock setting: After pressing the [7] button and pressing the register button, the manual lock function is set after a tone is heard.

How to set and dismiss 3D touch

  1. Enter password
    Touch the outdoor license plate to turn on the LED and enter the registered password.

  2. Press the [#] button twice in succession, then press the 0 button.

  3. Press [Registration] button When you press the [Registration] button on the outdoor side body, the 3D touch function is turned on or off.
    – Set tone: Piriricic
    – Off sound: Piric
    Open the battery cover and press the [Registration] button.

Reference

  1. It is a function to strengthen the security of password and it is a function to set a virtual number instead of the original number when the password is registered and authenticated for more than 1 second.
    Ex) When 1 is long pressed: It is recognized as a virtual number other than 1.

  2. Combined with the imaginary function of this product, password security is further strengthened.

  3. You can set each number and you can check that the lamp blinks when you press for more than 1 second.

  4. 3D touch mode is turned off at the factory.

Cautions

  1. When the 3D touch mode is released, the password is reset to “1234”.
  2. In case of master registration / deletion, fire / accident, etc., it is recognized as normal number mode.

Open the door in outdoor

Method 1
Open the door by password

  1. Enter password Touch the outdoor license plate to turn on the LED and enter the registered password.
  2. Press [] button When you press the [] button, you will hear a confirmation tone and then open when you open the door.

Method 2
Open door with smart key

  1. Contact smart key to smart key input unit When the registered [Smart Key] is touched to the smart key input part, a confirmation tone is heard and it opens when you open the door.

Method 3
Open door by interlocking(CDL-400MC/410MC only)

  1. Press the [OP/CL] button on the interlock

Press the [OP / CL] button on the interlock to open the door.

Door locking in indoor and outdoor

Set lock Indoor Outdoor
Auto lock Automatically locked after 2 seconds after Locked automatically

after 2 seconds after door closes
Manual lock| Press the [double lock] button on the indoor side body| Touch the number plate during 2 secods

Reference

  1. When you press [double lock] button in manual lock mode, you will hear a “beep” buzzer sound when the door is locked and inform you that the door is lockedv.

Internal double lock setting

It is a function that can not open a door with a password or a smart key outside the door.

Setting

  1. While the door is locked, press and hold the [double lock] button for 3 seconds If you press and hold the [DUAL LOCK] button for 3 seconds, the setting is completed with “OK” sound.

How to release internal

  1. Open the door by releasing the knob inside and releasing it
  2. Press the [double lock] button inside and dismiss

Deactivation from outdoor unit

  1. Input Password Touch number plate. When LED lights on, input registered password
  2. Press [#], [9] button Press [#] then press [9], indoor dual lock is off with beep sound

Dual authentication / Registration authentication setting

  1. Input password Touch number plate. When LED lights on, input registered password

  2. Press [#] button twice, press [1] or [8] button. [1]: Dual authentication
    [8]: Registration authentication

  3. Press [Regist.] button. Open the battery cover and press [registration] button
    Once press [Regist.] button on outdoor body,
    Dual authentication or registration authentication mode is on or off.
    Active: Sound – Piriricic
    Deactive: Sound – Piric

Reference

  1. If dual authentication mode is activated, Password + Card should be confirmed to open to door. (door open by BLE keeps available.)
  2. If registration authentication mode is activated, first authentication by existing password should be done for the next step.
  • No dual authentication / registration authentication is activated if factory setting.
  • To deactivate dual authentication / registration authentication, repeat the same procedure for activation

Burglar Alert
If door to be opened by abnormal operation such as door gap break through, burglar alert rings with more than 80db noisy sound.

How to deactivate burglar or temperature alert

Remove batteries or [password + ] , [smartkey touch] If temperature is too high, no deactivation. COMMAX CDL-400M Durable Door lock - temperature
alert

Volume Adjustment

**** Deadbolt of indoor unit must be come out from mortise before setting

How to

  1. Input Password When LED lights on after touching number plate, input registered password
  2. Press [#] button
  3. Press [3] or [6] to adjust volume [3] for volume up
    [6] for volume down

Reference

  1. Available total 8 levels of volume sound
  2. If sound pause mode, numbers are only flicking without sound

Battery Replacement Alert

If battery alert light is on on number plate or beep sounds ring, battery has to be replaced. All batteries must be replaced with new one at once.

COMMAX CDL-400M Durable Door lock - Battery Replacement
Alert

Caution

  1. Lifetime of battery can be varied according to manufacturers, date of production, working condition. (Expected lifetime : 10 months assuming no wireless operation, AA type alkaline 4ea, 10 times per one day use)

  2. If battery liquid leaks out, product can be damaged.
    Regular checking is recommended – every 6 months.

  3. Battery lifetime might be shortened if wireless module is activated.

Sound Pause Mode

Temporary silence function (1 time) regardless latest volume setting

How to

  1. Touch number plate and press [#]
  2. Press [*] after password or, contact Card to open the door.

Reference
Sound is back to the original volume if pause mode is operated once

High Temperture Alarm

Once extremely high temperature is detected (60℃± 10℃), locker is automatically released to open the door with huge sound to secure user’s safety.COMMAX CDL-400M Durable Door lock - Temperture
Alarm

Emergency Power

When door can not be opened due to fully discharged battery.

  • Contact the terminals of 9V battery to emergency power outlet
    Press [Password] and [ * ] to open the door while contacting terminals of 9V battery to emergency power outlet.

COMMAX CDL-400M Durable Door lock - Emergency Power

Factory Reset Mode

  1. Press
    [Registration] button. Open the battery cover and press [Registration] button for 5 secs

  2. Input “123578951” when number plate lights on

  3. Press [#] button for 2 secs. Factory default mode is completed with beep sound.

Caution

  1. All settings back to the default after factory reset

Anti-mischief alert and 1 minute pause

If unregistered [password], [smartkey] keeps used more than 5 times continuously, freeze operation for 1 minute with alert sound. COMMAX CDL-
400M Durable Door lock - mischief alert and 1 minute
pause

Reference

  1. To deactivate alert sound, open the door from indoor body handle
  2. If mechanical key is available, deactivate alert sound by key

Deadbolt Jam alert

When deadbolt is jammed during door open/close, alert sound of bee bee bee bee” rings 3 times. COMMAX CDL-400M Durable Door lock - Deadbolt Jam
alert

Caution

  1. If no sound deactivation or door lock malfunction, product installed position has to be adjusted. Please contact your local installer or service provider.

Door Open Alert during automatic lock setting

To inform door open status during automatics lock setting, alert sound rings 2 times with each 15 seconds interval if door opened.

Self-Diagnosis Table by each LED number flicking
To see the status of product by means of checking flicking number

ACTION SELF-DIAGNOSIS
Flicking ALL LEDs -Anti-mischief alert and 1 minute pause
Flicking LED number 2 -Error on password, card set
Flicking LED number 3 – Full of registered password, card
Flicking LED number 4 – Deadbolt Jam
Flicking LED number 5 – Burglar Alert
Flicking LED number 6 – Unregistered password, card
Flicking LED number 7 – Already registered address
Flicking LED number 8 – Fire Alarm
Flicking LED number 9 – Dual lock from Indoor unit
Flicking LED number 0

Summary of how to use

Function| Default|
---|---|---
Password change| 1234| [Registration] button ⇒ [1] button ⇒ Password to register⇒ [] button⇒ [] button
Card registration| None| [Registration] button ⇒ [2] button ⇒ Card (tag) recognition
(Continuous registration) ⇒ [Registration] button
Delete all card| | [Registration] button ⇒ [7] button ⇒ [#] button More than 5 seconds
Interlocking registration| None| [Registration] button ⇒ [3] button ⇒ Remote control [OP / CL] ⇒ [Registration] button
Delete the all interlocking| | [Registration] button ⇒ [8] button ⇒ [#] button More than 5 seconds
Open the door indoors| | Door lock handle: Push the manual opening / closing device towards the door.
Close the door indoors| | Auto lock: Auto lock when the door is closed
| Manual Locking: Press the [Internal Dual Locking] button
Open the door outdoors| | Password: LED of window number LED ON ⇒ Enter password ⇒ Press [] button
| Card: Card contact with card recognition
| Emergency key: Rotate after inserting emergency key into Emergency key insertion part
Close the door outdoors| | Auto lock: Auto lock when the door is closed
| Manual locking: Touch the license plate of the window for 2seconods
Auto lock setting| Automatic locking| Enter the password ⇒ Press the [#] [#] button ⇒ Press the [4] button ⇒ Press the [Registration] button
Manual lock setting| Enter the password ⇒ Press the [#] [#] button ⇒ Press the [7] button ⇒ Press the [Registration] button
Set dual authenitication mode| Release| Enter the password ⇒ Press the [#] [#] button ⇒ Press the [1] button (Individual authentication / Dual authentication)
⇒ Click the [Registration] button
Set registration authenitication mode| Release| Enter the password ⇒ Press the [#] [#] button ⇒ Press the [8] button (General registration / double registration)
⇒ Click the [Registration] button
3D touch authenitication mode| Release| Enter the password ⇒ Press the [#] [#] button ⇒ Press the [0] button ⇒ Press the [Registration] button
Set sound (beep sound), release sound (beep sound)
Internal dual lock LED setting| Release| Enter the password ⇒ Press the [#] [#] button ⇒ Press the [5] button ⇒ Press the [Registration] (On/Off)
Internal force lock setting| | Press and hold the [Internal force lock] button for 3 seconds
Release internal force lock| | Indoors: manual opening and closing with door open and door closing
Outdoors: Enter the password ⇒ Press the [#] button ⇒ Press the [9] button
Etiquette mode function| Normal mode| Password: Press [#] button ⇒ Enter password ⇒ Press [
] button
Buzzer volume setting| | Treble: Enter password ⇒ Press [#] button ⇒ Press [3] button
Bass: Input password ⇒ Press [#] button ⇒ Press [6] button
Release alram sound| | Indoor: When battery is removed
Outdoors: Password, card authentication

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals