Product Information
Specifications
- Product Code: PRO-G-H Sensor and Housing
- Area of Use: Pavement
- Heater Hold-On Time: 1 hour
- Circuit Type: NEC Class 2
- Supply Voltage: Bus-wire type
- Lead Length Extension
- Operating Temperature
- Storage Temperature
Product Description
The PRO-G-H is a pavement-mounted sensor and housing that reliably detects snow and ice conditions on pavement surfaces. It ensures that deicing heaters operate only when needed, minimizing energy costs without sacrificing snow melting effectiveness. The built-in hold-on timer keeps heaters operating for an hour after snow stops to help ensure complete snow melting.
The PRO-G-H accurately measures pavement temperature by compensating for its internal heating, eliminating the need for a separate pavement temperature sensor. It mounts closely to the deicing heaters for improved efficiency, ensuring that the pavement and sensor become dry at about the same time.
The new mounting system helps align the PRO-G-H with the pavement surface, and it offers six available conduit locations for installation flexibility and simplicity. The sensor sub-assembly is field replaceable without disturbing the pavement. The PRO-G-H is a NEC Class 2 low-voltage device, simplifying installation.
Only brass, epoxy, and stainless steel are exposed to the pavement surface, giving the PRO-G-H a handsome appearance that will please building owners, engineers, and architects.
Product Assembly
The PRO-G-H consists of a pavement-mounted sensor and housing. Please refer to
the installation manual for detailed instructions on how to assemble the
product.
Warranty & Maintenance
When installed according to the installation manual, the PRO-G-H is covered by
Warmup’s 2-year manufacturer warranty.
Technical Support
Warmup provides 24/7/365 technical support. For quotes, layouts, and specific
technical information, please contact us:
-
Warmup USA
25 Francis J Clarke Cir., Suite A, Danbury, CT 06810
Tel.: 888-927-6333
Email: us@warmup.com -
Warmup CANADA
374 Wellington St W, Toronto, ON M5V 1E3
Tel.: 905-990-2075
Email: ca@warmup.com
Related Products
For more information on our related products, please visit our website:
FAQ
-
How does the PRO-G-H detect snow and ice conditions on pavement surfaces?
The PRO-G-H detects snow and ice conditions by accurately measuring pavement temperature and compensating for its internal heating. -
What is the purpose of the hold-on timer?
The hold-on timer keeps the deicing heaters operating for an hour after snow stops to ensure complete snow melting. -
Is the PRO-G-H easy to install?
Yes, the PRO-G-H is designed for easy installation with its new mounting system and six available conduit locations. -
What materials are exposed to the pavement surface?
Only brass, epoxy, and stainless steel are exposed to the pavement surface, giving the PRO-G-H a pleasing appearance.
PRODUCT CODE
PRO-G-H SENSOR AND HOUSING
PRODUCT DESCRIPTION
- The PRO-G-H, reliably detects snow and ice conditions on pavement surfaces. This ensures that deicing heaters operate only while needed which minimizes energy costs without sacrificing snow melting effectiveness.
- A built-in hold-on timer keeps heaters operating for an hour after snow stops to help ensure complete snow melting.
- The PRO-G-H senses snow as moisture detected between below 38°F (3.3°C). Operation in the 32° to 38°F (0°to 3.3°C) temperature range eliminates otherwise slow melting. The PRO-G-H accurately measures pavement temperature by compensating for its internal heating. This eliminates the cost and complexity of a separate pavement temperature sensor.
- For improved efficiency, the PRO-G-H mounts closely to the deicing heaters to ensure that pavement and sensor become dry at about the same time.
- The new mounting system helps align the PRO-G-H with the pavement surface. Six available conduit locations add to installation flexibility and simplicity. The sensor sub-assembly is field replaceable without disturbing the pavement. The PRO-G-H is a NEC Class 2 low voltage device which simplifies installation.
- Only brass, epoxy, and stainless steel are exposed to the pavement surface. Precision machining gives the PRO-G-H a handsome appearance that will please the building owner, engineer, and architect.
ADVANTAGES
- Control based upon pavement conditions
- Rugged construction
- Simple installation
- Low voltage operation
- Reliable snow melting
- Minimum energy cost
- Long trouble-free life
SPECIFICATION
- Area of Use Pavement
- Heater hold-on time 1 hour
- Activation Temperature 38˚F (3.37˚C)
- Circuit type NEC Class 2
- Supply voltage 24 VAC (Supplied by panel)
- Bus-wire type 3-wire jacketed cable
- Lead Length Extension
- Up to 2,000’ (609m) using 12 AWG 3-wire jacketed cable
- Up to 500’ (152m) using 18 AWG 3-wire jacketed cable
- Operating temperature −40°F to 160°F (−40°C to 71°C)
- Storage temperature −50°F to 180°F (−45°C to 82°C)
DIMENSION
PRODUCT ASSEMBLY
WARRANTY & MAINTENANCE
When installed according to the installation manual, the PRO-G-H is covered with Warmup’s 2-year manufacturer warranty.
TECHNICAL SUPPORT
Warmup is available 24/7/365 at
888-927-6333. For quotes, layouts and
specific technical information, contact us at:
Warmup USA
25 Francis J Clarke Cir., Suite A, Danbury, CT 06810
888-927-6333
us@warmup.com
Warmup CANADA
374 Wellington St W, Toronto, ON M5V 1E3
905-990-2075
ca@warmup.com
RELATED PRODUCTS
- PRO-A Aerial Snow Sensor
- PRO-R Gutter Sensor
WARMUP INC.
USA: us@warmup.com
Tel.: 1-888-927-6333
www.warmup.com
CANADA: ca@warmup.com
Tel.: 1-888-592-7687
www.warmup.ca
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>