Karibu 80414 Sauna Leona Instruction Manual

May 15, 2024
Karibu

Karibu-LOGO

Karibu 80414 Sauna Leona

Karibu-80414-Sauna-Leona-PRODUCT

Items supplied
(Subject to technical changes)
The control unit consists of the following components as supplied:

  1. Control unit with operation panel and integrated load unit
  2. Sensor with heater sensor and thermal fuse
  3. Sensor with temperature sensor/humidity sensor
  4. 2 sensor cases
  5. 1 silicone sensor cable, 3/4-stranded, with an approx. length of 5 meters
  6. Assembly bag (three 4 x 40 mm screws and four 3 x 30 mm screws)

Technical data

  • Housing dimensions: Width 235 mm – height 195 mm – Depth 75 mm
  • Operation: Touchpad – touch control
  • Display 4: sections of 15 mm x 30 mm each
  • Protection: IPX4
  • Rated voltage: 400 V ~ 3 N PE
  • Switching power in Finnish mode: Maximum 10.8 kW ohmic load (AC1 operation)
  • Switching power in humidity mode: Maximum 9.3 kW plus 1.5 kW for the bio evaporator unit
  • Control range for Finnish mode: 5° to 100° Celsius – 5° adjustment
  • Control range for bio mode: 5° to 70° Celsius – 5° adjustment units
  • Heater sensor limit: 125° Celsius (heater sensor no. 1)
  • Temperature limit: 140° Celsius (heater sensor no. 1)
  • Temperature indicator: Maximum 110° Celsius (RAL point sensor no. 2)
  • Humidity control: Measurement by humidity sensor – actual measurement
  • Heat cycle limit: 240 minutes or 4 hours
  • Lighting: Maximum 60 W – dimmable 10% adjustment units
  • Ambient temperatures: -15° to plus 40° Celsius
  • Our doors: Protective enclosure required (splashproof)

Explanation of symbols

Information!
This provides the user with useful information and tips about how to operate and use the sauna system (sauna cabin, sauna heater and sauna controller)!
Warning!
Danger!
Warnings about possible dangers or dangerous situations which could even lead to loss of life!
Caution!
Instructions or warnings that could lead to defects or damage to components if not observed.
Electrical voltage!
Warns about voltage and high voltage! Failure to observe this warning may result in an electric shock.

General information and instructions on sauna usage

Sauna cabin – sauna heater – sauna controller

  • The FIN and BIO control units are an integral part of a well-functioning sauna cabin, as long as all the necessary conditions are properly met.
  • A control unit can only work to optimum effect in combination with a suitable sauna heater if the electrical connections from the main distributor to the control unit and from the control unit to the sauna heater have been installed correctly and professionally under our circuit diagrams and specifications using the materials intended for the purpose.
  • Faults on the control unit may also be caused by insufficient incoming air or insufficient ventilation of the sauna heater, as well as by a lack of waste air vents or waste air vents that are too small when the sauna is used continuously. In this connection, please refer to and observe our “Information sheet” which is also included.
  • About the temperature and humidity settings, discrepancies between the set and displayed temperature and humidity are possible. This can be explained by the fact that the mechanical display units are generally installed on the inside wall of the sauna. The temperature of the sauna wall, however, is always lower than that of the actual air temperature in the cabin.
  • The displayed humidity levels can be incorrect at the start for as long as the cabin has not heated up enough to a sufficient temperature.

General safety instructions

Proper use

  • The FIN and BIO control units are designed only for use for the control of sauna heaters with a maximum output of up to 10.80 kW.
  • The FIN control unit is for sauna heaters with Finnish mode (temperature control only) and the BIO control unit can be used for bio mode (temperature and humidity).
  • The control unit is designed to be used in sauna cabins which are suitable for the purpose! The control unit is only suitable for the operation of approved sauna heaters and in sauna cabins which are suitable for the purpose.
  • The control units are designed for operation in private households only!
  • Any claims for compensation for damages arising out of or in connection with improper use are excluded.
  • The user or operator will be exclusively responsible for any damages resulting from such improper use.

Installation and electrical connection

The control units must be correctly installed under the supplied installation instructions and connected to the electricity supply under the enclosed circuit diagram. Only a qualified electrician or an electrical contractor may make the electrical connection from the main distributor in the residential building to the control unit and from the control unit to the sauna heater. The system must be fitted with a separate residual current device circuit breaker (earth leakage circuit breaker 40A 30mA). Refer to the safety actions required by VDE 100 Section 49 DA/6 and VDE 0100 Part 703/11.82 Section 4.

Dangers from electrical voltage
Contact with live parts may lead to potentially fatal injuries.
Before any work on the system or the installation is started, the power supply to the control unit must be disconnected and measures taken to secure it to prevent it from being switched on again.

Requirements to be met by the operator
Only people over the age of 18 are allowed to use and operate this control unit and the sauna heater connected to it. People with physical handicaps are only allowed to operate the control unit under supervision. Before starting, the person doing the operating must ensure that there are absolutely no combustible objects (towels, bathrobes, etc.) on or beneath the sauna heater, or stored in the vicinity of the sauna heater.

Alterations and modifications

Alterations and modifications to the control units and/or the wiring or to the electrical connections could lead to unforeseeable dangers! Alterations to any part of the complete system are prohibited!

Safety and dangers
Read the operating instructions carefully before starting the work of fitting and installation and observe all information and instructions on potential dangers. The safety instructions provided here and the additional instructions provided in the following chapters must be observed, in order to reduce health risks and avoid dangerous situations. Improper operation could lead to serious injuries.

General safety information

  • This equipment can be used by children of 8 years and older and by people with limited physical, sensory or mental capacities or those with no experience or knowledge if they are supervised or have received instruction in how to use the equipment safely and understand the dangers that result from such use.
  • Children are not allowed to play with the equipment.
  • Unless supervised, children are not allowed to clean the equipment or carry out user-level maintenance work.
  • If permanently installed equipment is not equipped with a power cable and a plug or other means of disconnecting from the mains power supply with a contact opening on each pole by the conditions of overvoltage category III for complete disconnection, it is a requirement that the instructions must specify that a disconnecting device of this type must be incorporated into the permanently installed electrical installation according to the installation regulations.
  • The instructions for permanently installed equipment must specify how the equipment has to be fastened to the surface to which it is to be fastened.
  • The method used must not involve the use of adhesives, because these are not considered to be a reliable means of fastening.
  • If the insulation is damaged, switch off the power supply immediately and arrange for it to be repaired by a specialist contractor.
  • Work on electrical equipment may only be carried out by a professional!
  • Never bypass any fuses or deactivate them.
  • Check the rating data whenever a fuse needs to be replaced.
  • Protect the control units against moisture.
  • The controller housing may only be opened by a professional.
  • Objects on the sauna heater or in the vicinity of the sauna heater could cause a fire and lead to injuries.
  • Keep children away from the controller and the sauna heater.
  • Covering over the temperature and humidity sensors or placing them in the wrong position could lead to higher temperatures and could therefore cause a fire.
  • Make sure that there is sufficient air circulation in and around the entire sauna cabin.

Mounting the control unit on a wall

Karibu-80414-Sauna-Leona-FIG-6

Control units – versions

  • Version for Finnish mode (temperature)

Karibu-80414-Sauna-Leona-FIG-7

  • Version for Finnish and BIO mode (temperature + humidity)

Karibu-80414-Sauna-Leona-FIG-8

Fitting the sensor

  • View from above – Sauna cabins up to approx. 7.99 m³ in size

Karibu-80414-Sauna-Leona-FIG-9

  • View from above – Sauna cabins larger than 8 m³ in size

Karibu-80414-Sauna-Leona-FIG-10

Sauna Control FIN connection diagram

Technical support: [email protected].

Karibu-80414-Sauna-Leona-FIG-11

Sauna Control BIO connection diagram

Karibu-80414-Sauna-Leona-FIG-12

Sauna Control FIN P&P connection diagram

Karibu-80414-Sauna-Leona-FIG-13

  1. illumination/light
  2. Mains connection
  3. Heater connection
  4. Sensor 1
  5. Sensor 2

Sauna Control BIO P &P connection diagram

Karibu-80414-Sauna-Leona-FIG-14

  1. illumination/light
  2. Mains connection
  3. Heater connection
  4. Sensor 1
  5. Sensor 2

Starting – operation – displays

Turning the control unit on with the main switch

Karibu-80414-Sauna-Leona-FIG-15

  • To preset the values you simply have to lightly tap the fi elds marked with the + and – symbols! Turn on the main switch!
  • Values can be adjusted in both directions (+ and -).

Karibu-80414-Sauna-Leona-FIG-16

Adjusting the lighting

Karibu-80414-Sauna-Leona-FIG-17

Adjusting the start/stop function Setting

Karibu-80414-Sauna-Leona-FIG-18

  • Actuate the + and – buttons at the same time with your index finger and middle finger

Karibu-80414-Sauna-Leona-FIG-19

Setting the temperature

Karibu-80414-Sauna-Leona-FIG-20

  • Setting higher than 70° – Humidity indicator “OFF”
  • Sauna temperature higher than 70° – Humidity indicator “OFF”

Karibu-80414-Sauna-Leona-FIG-21

Setting the humidity level

Karibu-80414-Sauna-Leona-FIG-22

  • Bio/humidity mode is only possible up to a temperature of 70° Celsius!

Karibu-80414-Sauna-Leona-FIG-23

  • A buzzing signal will sound if there is insufficient water.
  • The evaporator switches off automatically after 1 minute.
  • The indicator switches to 000 – a restart is required
  • When a function is active, the LED will be illuminated!
  • When a function is inactive, the LED will be dark!

Karibu-80414-Sauna-Leona-FIG-24

Display mode – Time / Temperature

Start

  • Indicator fl ashes – the control unit is in standby mode
  • LED illuminated – the control unit is in heating mode
  • Indicator fl ashes after heating mode – the control unit is in standby mode (switches off after 240 minutes)

Temperature

  • Temperature setting can be adjusted from 5° to 100° with the + or – button (5° steps)
  • Temperature preselection 85° – indicator flashes for 5 seconds
  • The indicator switches to the actual temperature in the cabin – LED illuminated /heating mode is active
  • The temperature reached – LED is off / heating mode is inactive

Display mode – Humidity / Lighting

Humidity

  • Indicator shows 000, evaporator is not in operation
  • The indicator flashes and switches to the actual value after 5 seconds, the LED is illuminated, and the evaporator is in heating mode!
  • Preset humidity reached, LED off, evaporator mode is in standby mode
  1. The temperature is set to over 70°, the evaporator will be switched off by the system
  2. The evaporator is switched off (insufficient water)

Lighting

  • Indicator “000”, lighting is switched off, LED off
  • The lighting can be adjusted in steps of 10%, from 50% to 100% luminosity
  • The indicator flashes for 5 seconds and then lights up
  • LED illuminated, lighting is switched on

Humidity – temperature diagram

Karibu-80414-Sauna-Leona-FIG-39

Error messages

  • The temperature sensor (sensor 1) on the heater has no contact or is not properly connected
  • The thermal fuse (sensor 1) on the heater has no contact or is not properly connected
  • Temperature sensor (sensor 2) at RAL point has no contact or is not properly connected (2 connections)
  • The humidity sensor (sensor 2) at the RAL point has no contact or is not properly connected (2 connections)
  •  When the evaporator is switched on, it is not possible to set any of the values and the indicator flashes and shows “OFF”!
  • The water shortage terminal (water shortage indicator) is not connected!

Explosionszeichnung Sauna Control FIN

Karibu-80414-Sauna-Leona-FIG-45

Stückliste Sauna Control FIN

Karibu-80414-Sauna-Leona-FIG-53

Explosionszeichnung Sauna Control BIO

Karibu-80414-Sauna-Leona-FIG-46

Stückliste Sauna Control BIO

Karibu-80414-Sauna-Leona-FIG-54

Explosionszeichnung Sauna Control FIN P &P

Karibu-80414-Sauna-Leona-FIG-47

– Stückliste Sauna Control FIN P &P

Karibu-80414-Sauna-Leona-FIG-55

Explosionszeichnung Sauna Control BIO P &P

Karibu-80414-Sauna-Leona-FIG-48

Stückliste Sauna Control BIO P &P

Karibu-80414-Sauna-Leona-FIG-56

ISC GmbH • Eschenstraße 6 • D-94405 Landau/Isar

  • explains the following conformity according to EU directives and norms for the following product

Karibu-80414-Sauna-Leona-FIG-50

For EU countries only

Never place any electric tools in your household refuse.
To comply with European Directive 2002/96/EC concerning old electric and electronic equipment and its implementation in national laws, old electric tools have to
be separated from other waste and disposed of in an environmentally friendly fashion, e.g. by taking to a recycling depot. Recycling alternative to the demand to return electrical devices: As an alternative to returning the electrical device, the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinquished. This can also be done by handing over the used device to a returns center, which will dispose of it under national commercial and industrial waste management legislation. This does not apply to the accessories and auxiliary equipment without any electrical components which are included with the used device.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH. Subject to technical changes.

GUARANTEE CERTIFICATE

Dear Customer,
All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. Of course, if you would prefer to call us then we are also happy to offer our assistance under the service number printed below. Please note the following terms under which guarantee claims can be made:

  1. These guarantee terms cover additional guarantee rights and do not affect your statutory warranty rights. We do not charge you for this guarantee.
  2. Our guarantee only covers problems caused by material or manufacturing defects, and it is restricted to the rectification of these defects or replacement of the device. Please note that our devices have not been designed for use in commercial, trade or industrial applications. Consequently, the guarantee is invalidated if the equipment is used in commercial, trade or industrial applications or for other equivalent activities. The following are also excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the operating instructions (e.g. connection to the wrong mains voltage or current type), misuse or inappropriate use (such as overloading of the device or use of nonapproved tools or accessories), failure to comply with the maintenance and safety regulations, ingress of foreign bodies into the device (e.g. sand, stones or dust), effects of force or external influences (e.g. damage caused by the device being dropped) and normal wear resulting from proper operation of the device. This applies in particular to rechargeable batteries for which we nevertheless issue a guarantee period of 12 months. The guarantee is rendered null and void if any attempt is made to tamper with the device.
  3. The guarantee is valid for 2 years starting from the purchase date of the device. Guarantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies when an on-site service is used.
  4. To assert your guarantee claim, please send your defective device postage-free to the address shown below. Please enclose either the original or a copy of your sales receipt or another dated proof of purchase. Please keep your sales receipt in a safe place, as it is your proof of purchase. It would help us if you could describe the nature of the problem in as much detail as possible. If the defect is covered by our guarantee then your device will either be repaired immediately and returned to you, or we will send you a new device.

Of course, we are also happy to offer a chargeable repair service for any defects that are not covered by the scope of this guarantee or for units that are no longer covered. To take advantage of this service, please send the device to our service address.Karibu-80414-Sauna-Leona-
FIG-52

[email protected].