ELKAY EZSTL8WSX3G Versatile Bottle Filling Stations and Coolers Instruction Manual
- June 17, 2024
- ELKAY
Table of Contents
ELKAY EZSTL8WSX3G Versatile Bottle Filling Stations and Coolers
Product Information
The product is a versatile bottle filling station and cooler from the EZ TM & LZTM Series. It comes in various models including EZSTLDWS1G, EZSTL8WS1G, EZSTL8WS2G, EZSTL8WS3G, LZSTLDWS1G, LZSTL8WS1G, LZSTL8WS2G, and LZSTL8WS3G.
The cooler design allows for alternate installations, with the option to install the unit either left-hand high and right-hand low or left-hand low and right-hand high. Please note that a basin change may be required for alternate installations. The refrigerated unit must always be installed on the right- hand side.
Specifications
- Model: EZSTLDWS1G, EZSTL8WS1G, EZSTL8WS2G, EZSTL8WS3G, LZSTLDWS1G, LZSTL8WS1G, LZSTL8WS2G, LZSTL8WS3G
- Installation: Versatile – can be installed left-hand high and right-hand low or left-hand low and right-hand high
- Refrigerated Unit Installation: Must be installed on the right-hand side
Product Usage Instructions
Standard Rough-in for Left-Hand High, Bottle Filler Low Models
To install the product in the standard configuration (left-hand high and bottle filler low), follow the rough-in measurements provided below:
Measurements
- Width: 18 3/8″ (467mm)
- Depth: 2″ (51mm)
- Height: 6 3/8″ (162mm)
- Basin Change: May be required. Refer to the desired rough-in and manual for instructions.
Important Notes
- It is highly recommended to have a dedicated circuit and load protection sized for 20 amps.
- The refrigerated unit must always be installed on the right-hand side.
FAQ
- Q: Can the product be installed in different configurations?
- A: Yes, the product can be installed either left-hand high and right-hand low or left-hand low and right-hand high. Please refer to the manual for detailed instructions on alternate installations.
- Q: Can I install an optional filter with this product?
- A: Yes, you can install an optional filter. The manual provides alternate locations (labelled A and D) for the filter installation.
- Q: What is the recommended circuit requirement for the product?
- A: It is highly recommended to have a dedicated circuit and load protection sized for 20 amps.
- Q: Can the product be used as a children’s ADA cooler?
- A: Yes, the product can be installed for use as a children’s ADA cooler. The height may need to be reduced by 3 inches for this installation.
EZ ™ & LZ™ Series Versatile Bottle Filling Stations & Coolers
- Versatile Cooler Model LZSTL8WSLK configuration as shipped
- Versatile Cooler Model LZSTL8WSLK alternate installations
Note : Danger! Electric shock hazard. Disconnect power before servicing unit
Uses HFC-134A refrigerant
STANDARD ROUGH-IN FOR LEFT-HAND HIGH, BOTTLE FILLER LOW MODELS
LEGEND
-
RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm)
MAXIMUM OUT FROM WALL -
RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
-
1-1/2” TRAP NOT FURNISHED
NOTE : IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS. -
ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET
-
INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
-
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
-
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI
THE REFRIGERATED UNIT MUST BE INSTALLED ON THE RIGHT-HAND SIDE.
ALTERNATE ROUGH-IN FOR RIGHT-HAND HIGH, BOTTLE FILLER LOW MODELS REQUIRES BASIN ASSY CHANGE. SEE PAGES 11-13 FOR INSTRUCTIONS
LEGEND
-
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
-
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
-
C = 1-1/2” TRAP NOT FURNISHED
NOTE : IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS -
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
-
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL
-
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI
THE REFRIGERATED UNIT MUST BE INSTALLED ON THE RIGHT-HAND SIDE.
ALTERNATE ROUGH-IN FOR RIGHT-HAND HIGH, BOTTLE FILLER HIGH MODELS
LEGEND
- A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
- B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
- C = 1-1/2” TRAP NOT FURNISHED
- D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
- E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL
- F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI
THE REFRIGERATED UNIT MUST BE INSTALLED ON THE RIGHT-HAND SIDE.
ALTERNATE ROUGH-IN FOR LEFT-HAND HIGH, BOTTLE FILLER HIGH MODELS REQUIRES BASIN ASSY CHANGE. SEE PAGES 11-13 FOR INSTRUCTIONS
LEGEND
- A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
- B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
- C = 1-1/2” TRAP NOT FURNISHED
- D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
- E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL
- F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI
REFRIGERATED UNIT MUST BE INSTALLED ON THE RIGHT-HAND SIDE
HANGER BRACKETS INSTALLATION
-
Remove the hanger brackets fastened to the back of the cooler by removing one (1) screw.
-
count the hanger brackets as shown in Figures 2, 3, 4 or 5.
NOTE: Hanger Bracket MUST be supported securely. Add a fixture support carrier if the wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes
INSTALLATION OF COOLER -
Hang the cooler on the hanger bracket. Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figures 2, 3, 4 or 5.
-
Remove the four (4) screws holding the lower front panel at the bottom of the cooler. Remove the front panel by pulling straight down and set aside.
-
Connect water inlet line–See Note 4 of General Instructions.
-
Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut and gasket to the trap and tighten securely.
IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove the tube, check for leaks after re-assembly. -
Install bottle filler per page (11).
-
Plug-in electrical power. The unit must have electrical power to have water flow
START UP Also See General Instructions -
Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw located on the right knee clearance area. CW adjustment will raise stream and CCW adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2” (165mm) from the bubbler on the downward slope of the basin.
NOTE : If continuous flow occurs at the end of the compressor cycle, turn the cold control counterclockwise 1/4 turn. -
Replace the front panel ensuring that the metal wrapper is secured inside of the upper shroud. Replace all four screws previously removed
CLEANING
Warm, soapy water or mild household cleaning products can be used to clean the
exterior panels of the EZ coolers. Extra caution should be used to clean the
mirror-finished stainless steel panels. They can be easily scratched and
should only be cleaned with mild soap and water or Windex glass cleaner and a
clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive
cleaners will void the warranty.
Service Instructions
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove four
screws from the bottom of cooler to remove the lower shroud. To remove the
upper shroud for access to the push bars, regulator, solenoid valve or other
components located in the top of the unit, remove the lower shroud, disconnect
the drain, remove four screws from tabs along the lower edge of upper shroud,
unplug two wires and water tube.
Bubbler
To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be reached through the access panel on the underside of the upper shroud. Remove the access panel by removing the retaining screw. To remove the bubbler, loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel and retaining screw.
Switches Behind the Push Bar
The regulator in an EZ cooler is always held fully open by the use of a single regulator nut (See Fig. 6 or 7). Water is not dispensed until the pushbar is depressed to activate a switch which then opens a solenoid valve. When installing the regulator nut, the regulator spring must be depressed while turning the nut. To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall side pushbars, the front of the pushbar is inserted first. While keeping the switch depressed, snap the rear of the pushbar into position.
Bottle Filler Installation Instructions
- Remove two (2) mounting screws with a 5/32” Allen wrench holding the top cover to Bottle Filler (See Fig. 9). Remove the top cover. Note do not discard mounting screws, they will be needed to reinstall the top cover.
- Remove the wall mounting plate from the Bottle Filler. Place the wall plate against the wall on top of the basin. Centre the wall plate side to side with the basin. Mark the six (6) mounting holes with a pencil (See Fig. 2, 3, 4 or 5).
- Remove wall mounting plate from the wall. NOTE: The mounting plate MUST be supported securely. Add a fixture support carrier if the wall will not provide adequate support.
- Install wall mounting plate to the wall using six (6) 7/16” obround mounting holes (mounting bolts not included) (See Fig. 8). Use appropriate fasteners for your wall type.
- Lay Bottle Filler on the water cooler basin and cut the insulation from tube even with bottom of gasket, remove this insulation from the 3/8” tube but do not discard it. Feed the power cord and waterline through the hole on top of water cooler. NOTE: To prevent scratching the basin place a towel or soft cloth over the entire basin when work-ing above it.
- Install a gasket on the bottom of the bottle filler tower with a gasket support bracket & (2) screws (See Fig 11).
- Feed power cord & 3/8” water line through hole in tower/basin gasket (See Fig 10).
- With the power cord , wire(s), and waterline through a hole on top of the water cooler place the Bottle Filler on the three (3) angled tabs protruding from the wall mounting plate installed on a wall. Make sure round boss in gasket fits in hole of basin. (See Fig. 18, p.17).
- Once the Bottle Filler is installed on wall plate tabs, water line, wire(s) and power cord are installed properly, push the top of Bottle Filler toward wall and line up top cover two (2) holes.
- Reinstall Top Cover on Bottle Filler (See Fig. 9) with two mounting screws from Step 1 above. Caution, do not over tighten screws.
- Install the remaining tube insulation to the water line from the bottle filler, and connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” water line to the tee.
- Install the filter cartridge , remove filter from a carton, remove the protective cap, attach the filter to filter head by firmly inserting into head and rotating filter clockwise.
- Turn water supply on and inspect for leaks. Fix all leaks before continuing.
- Once unit has been inspected for leaks and any leaks found corrected, plug Bottle Filler and unit into wall. Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the “ON” position.
- Once power is applied to Bottle Filler , the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter.
- Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. Note: the first initial dispenses might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line.
- Once unit tests out, install Lower Panel back on water cooler(s). Unit is now ready for use.
BF11 – BF12 PROGRAM SETTING THE CONTROL BOAR
VERIFY CONTROL BOARD SOFTWARE
- To verify the software program of the control board the unit will need to be shut down and restarted. The chiller (if present) does not need to be shut down and restarted.
- The unit’s lower panel must be open to access the power cord and wall outlet.
- Shut down the unit by unplugging the power cord from the wall outlet or switching off the circuit breaker to the unit.
- Restart the unit by plugging the power cord back into the wall outlet.
- Upon start up, the bottle count display will show the software designation of BF11 or BF12.
ACCESSING THE PROGRAMMING BUTTON
- To access the program button, remove the top cover of the bottle filler. Remove the two (2) screws holding top cover to the bottle filler with a 5/32” Allen wrench. Remove top cover. Do not discard mounting screws, they will be needed to reinstall the top cover after programming operations are completed. The programming button is located at the top right side of the unit on the control board. NOTE: When applicable, there is also an alternate reset button located on the lower part of the water cooler. After removing the bottom cover, the reset button will be located on the left side of the cooler, mounted on the side panel support.
RESET THE FILTER MONITOR
- Instructions apply to filtered units only.
- Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
- RST FLTR” – Reset Filter Monitor
- SETTINGS” – System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.
- When the display changes to “RST FLTR”, depress the button again. The display will change to show “FLTR =”. Depress the button again and the display will show “FLTR =0”
- The Green LED should be illuminated indicating that the visual filter monitor has been reset.
SETTING THE RANGE OF THE IR SENSOR WHERE APPLICABLE
- Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
- RST FLTR” – Reset Filter Status LED
- SETTINGS” – System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode. When the display changes to
- SETTINGS”, depress the button again. The display will change to show
- “RNG SET” – Range set for IR sensor.
- “UNIT TYP” – Type of unit (REFRIG or NON-RFRG)
- “FLT SIZE” – Select filter capacity
- “RST BCNT” – Reset bottle count
- When the display shows “RNG SET” push the program button once the display shows the current value (can be 1 – 10) e.g. “RNG = 3”.
- Once the display shows current value push the program button to scroll through values of 1 – 10. Select the desired range setting, “1” being closest to the sensor and “10” being farthest away.
- Once the range is selected allow approximately 4 seconds to pass and then the display will go back to the bottle counter and be in run mode.
- Test bottle filler by placing the bottle or hand in front of the sensor to make sure water is dispensed.
SETTING UNIT TYPE
-
Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
-
RST FLTR” – Reset Filter Status LED
-
SETTINGS” – System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default
back to bottle count and be back in run mode. Continued from below: -
When the display changes to “SETTINGS”, depress the button again. The display will change to show
-
“RNG SET” – Range set for IR sensor.
-
“UNIT TYP” – Type of unit (REFRIG or NON-RFRG)
-
“FLT SIZE” – Select filter capacity
-
“RST BCNT” – Reset bottle count
-
When the display shows “UNIT TYPE” push the program button once the display will show current value. Can be REFRIG or NON-RFRG
-
Push the button once to change the value. Once the value is selected the display will show the new value. (Can be REFRIG or NON-RFRG) “REFRIG“ – stands for refrigerated product. In this setting the flow rate is estimated at 1.0 gallon per minute. “NON-RFRG“ – stands for nonrefrigerated product. In this setting, the flow rate is estimated at 1.5 gallons per minute. Both “REFRIG“ and “NON-RFRG“ simulate 1 bottle equal to 20 oz.
-
Allow approximately 4 seconds to pass and the display will return to the bottle counter and be in run mode.
RESETTING BOTTLE COUNT
- Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
- RST FLTR” – Reset Filter Status LED
- SETTINGS” – System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.
- When the display changes to “SETTINGS”, depress the button again. The display will change to show:
- RNG SET”- Range set for IR sensor.
- “UNIT TYP” – Type of unit (REFRIG or NON-RFRG)
- “FLT SIZE” – Select filter capacity
- “RST BCNT” – Reset bottle count If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode.
- When the display shows the “RST BCNT” push the program button once the display shows current value, e.g. “0033183”.
- Once display shows current value push the program button once more to reset back to 0. The display will show BTLCT = 0 for approximately 2 seconds and then return to run mode showing 00000000 bottles. NOTE: Once the bottle count is reset to zero there is no way to return to the previous bottle count.
- Testing the bottle counter: REFRIG units: Place bottle or hand in front of the sensor for approximately 9 seconds to see bottle counter count 00000001, (This is based on filling a 20 oz. bottle). NON-RFRG units: Place bottle or hand in front of sensor for approximately 6 seconds to see bottle counter count 00000001, (This is based on filling a 20 oz bottle).
SETTING FILTER CAPACITY
- Depress the program button for approximately 2 seconds until the display changes then release. The display will change and scroll through two messages:
- “RST FLTR” – Reset Filter Status LED
- “SETTINGS” – System Settings Sub Menu If the program button is not pushed again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode.
- When the display changes to “SETTINGS”, depress the button again. The display will change to show:
- “RNG SET“- Range set for IR sensor.
- “UNIT TYP“ – Type of unit (REFRIG or NON-RFRG)
- “FLT SIZE” – Select filter capacity
- “RST BCNT“ – Reset bottle count If the button is not pushed again the display will scroll through the four messages above for three cycles and return to run mode.
- When display shows “FLT SIZE” push program button once. The display will show current value. Can be 3000GAL or 6000GAL.
- Push program button again to display the desired “FLT SIZE”.
- Allow approximately 4 seconds to pass and the display will return to bottle counter and be in run mode
INSTRUCTIONS TO MOVE THE BOTTLE FILLER & BASIN TO THE LEFT SIDE (NON- REFRIGERATED) FOR ALTERNATE MOUNTING VERSATILE BI-LEVEL
Refrigerated Cooler side:
Non-Refrigerated Cooler side:
INSTRUCTIONS CONTINUED.
Refrigerated Cooler side:
Non-Refrigerated Cooler side:
Precautions need to be taken when replacing the Basin/shroud assembly:
- Make sure all wires are inside frames so as not to become pinched.
- Water line coming from bottle fillter drain must be pulled down as not to interfere with the fan operation. The fan blade needs to spin freely.
INSTALL WRAPPERS & TRIM STRIPS PER PAGE 13 SEE PAGE 14 FOR PLUMBING DIAGRAMS
Versatile Wrapper and Trim Kit Installation Instructions
PLUMBING DIAGRAMS VERSATILE BI-LEVEL
PLUMBING DIAGRAMS FOR EZ BI-LEVEL COOLERS
220V PARTS LIST
WATERSENTRY® PLUS Filter Detail
BOTTLE FILLER REPLACEMENT PART KITS
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
ELKAY MANUFACTURING COMPANY
- 2222 CAMDEN COURT
- OAK BROOK, IL 60523
- 630.574.8484
- www.elkay.com