SuperFish Dosing Pump One User Manual

June 4, 2024
SuperFish

SuperFish Dosing Pump One

General instructions

| Read this manual carefully before using this device. Keep this manual for future reference.
---|---

Meaning of the symbols on the device itself:

| This device complies with all applicable EU standards.
---|---
| This device may not be disposed of with normal household waste but must be collected separately for recycling.

Use

Suitable for indoor use, for automatic dosing of liquids.

|

  • The temperature of the liquids being pumped should not exceed 60°C.
  • Do not use for pumping sewage water, flammable, corrosive and/or explosive liquids (e.g. petroleum, petrol, solvents), fats, oils or foodstuffs.

---|---

Safety

Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.

  • This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.

  • Ensure the voltage shown on the label matches the mains supply voltage.

  • Protect the socket and plug against moisture. Use a drip loop to ensure water cannot reach the socket via the cord (see Fig. A).

  • Install the dosing pump in a dry place and prevent the dosing pump from falling into water. Do not use the device if water damaged. The warranty is invalidated in the event of improper use or water damage.

  • Always switch off all devices at the mains supply before maintenance.

  • This device can be used by children aged from 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.

  • Modifications to the device may affect the safety. The warranty will also expire.

Function

With this dosing pump you can automatically and precisely add a certain amount of liquid (between 1 and 9999 ml) to your aquarium, terrarium or pond at a time interval between 1 and 72 hours.

Installation

  • Place the dosing pump in a dry, accessible place near your aquarium, terrarium or pond. You can easily set the pump down or hang it up with the suspension eye on the back.
    Fig. B Attach a tube via the tube coupling to the inlet of the pump, this inlet tube goes into the reservoir with the liquid to be dosed. Make sure the end of this tube is at the bottom of the reservoir.

  • Attach a tube via the non-return valve to the outlet of the pump, this tube goes to the aquarium, sump, terrarium or pond.
    Fig. C NOTICE! The maximum head of the dosing pump is 1.5 metres, bear this in mind when installing the dosing pump and the reservoir.

  • Turn the dosing pump on by plugging it into the mains.

Calibration (before first use)

  • The pump must be calibrated before use. This requires a reservoir of water and a measuring cup of at least 100ml.
  • Put the inlet tube into the reservoir.
  • Start the pump ( See programming: Manual dosing ) so that the tubes are completely filled with water. Make sure that there is no air left in the tubing before calibrating the dosing pump.
  • Stop the pump.
  • Put the other tube into the empty measuring cup.
  • Now you can start the calibration ( See programming: Pump calibration ).

Control panel

The following settings can be programmed using the control panel on the dosing pump:

  • The current time (F1).
  • Manual dosing (F2).
  • Calibration (F3).
  • Reservoir content (F4), can be set to 9999 ml.
  • Dosing quantity (F5), can be set between 1 and 9999 ml.
  • Dosing interval (F6), can be set between 1 and 72 hours.
  • With the arrows and you can choose the settings.
  • The OK button allows you to programme the setting.
  • Use the arrows and to change the times and values.
  • The arrow saves the programmed setting.

Programming

Current time (F1) setting
Press OK
The display shows F1 and the hours will flash
Press or to set the hours
Press OK and the minutes will flash
Press or to set the minutes
Press to save the time or press to save and move on to manual dosing (F2).

Manual dosing (F2)
The display shows F2, press OK and the pump starts pumping.
The tube fills slowly with water and the water will flow out of the other tube.
Press OK to stop pumping.
Press to move on to the calibration of the pump (F3).

Calibrating the pump (F3)
Before calibrating, make sure there is no air in the tubes and that the measuring cup is empty.
The display shows F3, press OK to start the pump.
The display will show the calibration value incrementing
Press OK to stop the pump when the water level in the measuring cup reaches 100 ml.
Press to save the calibration value or press to save and proceed to setting the reservoir content (F4).
NOTICE! Repeat calibration regularly to ensure correct dosing.

Setting the content of the reservoir (F4)
The display shows F4, press OK
Press or to set the amount of dosing medium (1-9999 ml) in the reservoir
By pressing OK you can switch between
Press to save the setting or press to save and proceed to setting the dosing quantity (F5).
If the liquid in the reservoir is insufficient for the next dosage, the unit emits an alarm signal.
End the alarm signal by pressing OK. Refill the reservoir and set the reservoir content (F4) again.
If the alarm goes off during programming, switch the pump off and on again briefly and then press OK to stop the alarm.

Setting the dosing quantity (F5)
The display shows F5, press OK
Press or to set the required dosing quantity (1-9999 ml)
By pressing OK you can switch between
Press to save the setting or press to save and to continue with setting the dosing interval (F6).

Setting the dosing interval (F6)
The display shows F6, press OK
Press or to set the time between the doses (between 1 hour and 72 hours) F6 36
Press to save the setting. The pump will immediately dose the set quantity under F5. The next dose will follow according to the set interval time under F6.
NOTICE! If you do not want the pump to start dosing immediately, press first and then press .
The dosing interval set under F6 is saved and will not start dosing until after the time set.
The set interval time therefore starts immediately.

Maintenance

  • Clean the outside of the dosing pump with a damp cloth.
  • The pump head, pump motor and tubes are subject to wear and tear and, depending on their use, must be replaced after a while. This is normal and is not covered by the warranty.
  • Replacement parts are available from your dealer.
    _ ** N OTICE!**_ NEVER lubricate the pump

Recycle information

This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste. Instead it must be handed in at an official collection centre (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products. Separate collection and recycling are better for the environment, public health and reduces waste.

Date of purchase:: --_____

www.aquadistri.com
Vlietweg 8, NL-4791 EZ Klundert The Netherlands, [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SuperFish User Manuals

Related Manuals