SuperFish PondECO Plus RC 26000 Electronic Filter Pump with Remote Control User Manual
- June 2, 2024
- SuperFish
Table of Contents
- SuperFish PondECO Plus RC 26000 Electronic Filter Pump with Remote
- General instructions
- Meaning of symbols
- Use
- Safety
- Function
- Pond installation
- Inline installation
- General installation
- Usage of the remote control
- Maintenance
- Recycling
- Warranty
- Pick-up & Replace Waranty
- DECLARATION OF CONFORMITY
- Technical specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SuperFish PondECO Plus RC 26000 Electronic Filter Pump with Remote
Control
General instructions
Read this manual carefully before using this device. Keep this manual for future reference.
Meaning of symbols
The following warning symbols and/or signal words are used in this manual:
-
DANGER!
This means an imminent danger due to electric current. Failure to follow the safety instructions can result in serious or fatal injury and/or serious damage to the product or environment. -
WARNING!
This means a dangerous situation. Failure to follow the safety instructions can result in moderate or minor personal injury and/or damage to the product or environment. -
NOTICE!
This means caution, useful information or advice.
Fig. … This refers to the relevant drawing … on pages 2 and 3 of this manual. -
Meaning of the symbols on the device itself:
- This device (pump) is suitable for outdoor use and can be used underwater up to a 2 metre depth.
- This device (pump) is waterproof.
- This device (remote control) has protection class III.
- This device complies with all applicable EU standards.
- This device may not be disposed of with normal household waste but must be collected separately for recycling.
Use
Suitable for outdoor use, for pumping pond water within the pond and inline set-up.
- The temperature of the pond water being pumped should not exceed 35°C.
- Do not use for pumping salt water, sewage water, flammable, corrosive and/or explosive liquids (e.g. petroleum, petrol, solvents), fats, oils or foodstuffs.
- Never run the device without water.
- Do not use for swimming pools and do not connect to drinking water supplies.
Safety
Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.
- This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
- Ensure the voltage shown on the label matches the mains supply voltage.
- This device must be connected to a socket which is earthed.
- Protect the socket and plug against moisture. Use a drip loop to ensure water cannot reach the socket and plug connection of the receiver via the cord (see Fig. A).
- The receiver must be installed in a dry place, with a minimum 2 metre clearing from the pond.
- Don’t use the product if the device, cord or plug is damaged. Return the device to your dealer for repair or recycling. A damaged cord or plug cannot be replaced, the device should be recycled.
- Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
- Never use the device when there are people in the water.
- Always switch off all devices at the mains supply before maintenance.
- Do not move or lift the device out of the water by the cord, only lift the device by the handle.
- This device can be used by children aged from 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.
- Modifications to the device may affect the safety. The warranty will also expire.
Function
-
The PondECO Plus RC is an electronic pond pump for use with filters, skimmers, waterfalls and water ornaments. The pump is equipped with a remote control and receiver which regulate the pump capacity and stepped head.
-
Run Dry Protection
The pump is equipped with a dry-running safety device, which is especially important when used inline. It is important that water can always be pumped around. If there is no water flow for 10 seconds, the pump will automatically stop and then restart after 10 seconds. If there is still no water flow, the pump will stop and restart again. This cycle is repeated 5 times, after which the pump stops completely. You can restart the pump when the water supply is restored. Pull the plug out of the socket, wait 60 seconds and plug it in again. The pump will now start up and pump water around. -
Thermal overload protection
The pump has a thermal overload protection in case the motor overheats, the pump switches off automatically. After a cooling down time of 15 to 20 minutes, the pump automatically switches on again. In order to prevent damage to the pump, it is essential to investigate the cause of the overheating and resolve the issue. Damage caused by overheating is not covered by the warranty.
Pond installation
-
Fig. B The PondECO RC pump is suitable for pond hoses with diameters of 40 and 50 mm. Cut the Multi-step hose connector to the
desired diameter and fasten it on the pump. -
Connect the pond hose to the hose connector using a hose clamp (not included).
-
Fig. C Preferably install the pump in the deepest part of the pond (max. 2 metre depth), or at least 20 cm below the water surface.
-
Make sure that the pump stands horizontally and firmly on a flat surface so that it cannot fall over
Inline installation
-
Fig. D For inline use, the pump section must be taken out of the housing.
-
Fig. E Open the housing by pressing the latch at the front and back, which will release the upper shell.
-
Fig. F Remove the bracket that runs over the pump by unscrewing the 2 screws and take the pump out of the housing.
-
At the front of the pump is the inlet (suitable hose connector (Art. 07070309) not supplied). At the top is the outlet (for the
supplied hose connector (Art. 07070309)). -
Fig. B First, cut the hose connectors to the desired diameter and then fasten them to the pump.
-
Connect the pond hoses to the hose connectors using hose clamps (not included).
-
Install the pump horizontally and firmly on a flat surface outside the pond. Make sure that the pump cannot tip over, if necessary you can secure the pump with screws.
General installation
Fig. A Connect the plug of the pump to the receiver, make sure that the plug
connections are protected against moisture. Install the receiver in a dry
place, with a minimum 2 metre clearing from the pond.
• NOTICE! The receiver must not get wet, place it in the handy SuperFish
DriBox (Art. 06070035) available from your dealer. This prevents water damage
to your receiver.
• Plug the receiver into the socket and make sure there is a drip loop in the
cord.
• Make sure that no one can trip over the cord and that the cord cannot be
damaged.
Usage of the remote control
The PondECO RC pump is equipped with a remote control with which you can easily switch the pump on and off. You can set the pump capacity, stepped head, thus aiding with consumption.
- At its lowest settings the pump will consume less energy but will also have a reduced performance and will therefore pump less water around. This may cause the pump to come to a standstill (especially with a lot of head, the use of long pond hoses and many bends). In that case, increase the pump capacity by one or two steps.
- This Remote Control is dedicated to the SuperFish PondECO Plus RC 26000 and E 26000 pumps. When used on a different type
of pump, this pump will not work or will work incorrectly. Make sure the remote control does not get wet, store it in a dry place.
Settings PondECO Plus RC 26000 via remote control
Step | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
---|---|---|---|---|---|---|---|---|---|---|
Pump capacity | 15,800 l/h | 17,200 l/h | 18,000 l/h | 18,700 l/h | ||||||
19,400 l/h | 20,100 l/h | 21,900 l/h | 22,600 l/h | 23,400 l/h | 25,100 l/h | |||||
Head | 2,6 m | 3.0 m | 3.2 m | 3.6 m | 4.0 m | 4.6 m | 4.6 m | 5.0 m | 5.4 m | 8.2 |
m
Power| 90 Watt| 100 Watt| 115 Watt| 130 Watt| 145 Watt| 160 Watt| 180
Watt| 200 Watt| 220 Watt| 240 Watt
Maintenance
- The pump should be cleaned regularly (minimum twice a year) to ensure trouble free operation. Scale deposits, in particular, can cause your pump to cease. There is no warranty on failures due to dirty pumps and scale build up inside the pump caused by improper or lack of maintenance.
- Remove the plug from the socket before carrying out maintenance!
- Disconnect the pump from the pond hose and rinse the housing under the tap or garden hose.
- For proper cleaning and descaling, it is best to use SuperFish Pump & UVC Clean (Art. 07070500), which is available from your dealer.
- Mix SuperFish Pump & UVC Clean in a large bucket with clean tap water, according to the instructions on the bottle. Immerse the pump into it and leave it there for 24 hours.
- Take the pump out of the bucket and let it drain before disassembling it.
- Fig. E Open the housing by pressing the latch at the front and back, which will release the upper shell.
- Fig. F Remove the bracket that runs over the pump by unscrewing the 2 screws and take the pump out of the housing.
- Dismantle the rotor housing by loosening the 4 screws on the front of the pump and remove the rotor.
- Brush and clean all parts and the housing thoroughly. Rinse everything with clean tap water and reassemble.
- Depending on usage the rotor and rotor housing can get worn out and damaged, this is normal. A new rotor (Art. 07070303) and rotor housing (Art. 07070307) are separately available from your dealer.
- NOTICE! During periods of frost you should remove the pump from the pond. Clean and dry the pump well and store it frost free.
Recycling
This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste. Instead it must be handed in at an official collection centre (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products. Separate collection and recycling are better for the environment, public health and reduces waste.
Warranty
2 years manufacturer’s warranty on materials and construction defects. Devices
must be returned complete with all components, accompanied with an official
proof of purchase confirming a purchase date for any warranty claims.
Incomplete devices of which parts are missing, and devices without proof of
purchase are not eligible for warranty. After receiving and checking, we will
determine whether the device will be repaired or replaced. For a device
repaired or replaced under warranty, the remaining time of the original
warranty period applies. Carefully read the instructions on installation, use
and maintenance. Damage due to incorrect use, damage due to contamination or
not cleaning the device, wear and damage to the rotor and damage to the cord
are not covered by the warranty.
Always keep the proof of purchase, without proof of purchase the warranty will
be void!
Pick-up & Replace Waranty
This PondECO Plus E /RC pump comes with a unique 2 year warranty with 48 hour
on site Pick-up and Replace service. In the event of a defect, the pump is
picked up within 48 hours and immediately replaced free of charge by a new one
(from Monday to Friday, no deliveries on Saturday and Sunday). Subject to
proper use and maintenance (regularly descaled and cleaned, cord and rotor not
damaged).
To qualify for this 48 hours Pick-Up & Replace Warranty, you must register
register within 1 month after purchasing the PondECO Plus E or RC pump. To
register, simply fill out the enclosed registration form in full and return it
with copy of purchase to Aquadistri.
If you do not register by the aforementioned deadline, the 48 hour Pick-up and
Replace Warranty will not be valid. For any problems during the warranty
period, simply contact your dealer.
The Pick-Up & Replace Warranty is only applicable in the Netherlands, Belgium,
Luxembourg, Germany, France and the United Kingdom. For residents of other
countries the normal warranty applies, for this you need to contact the dealer
where the pump was purchased.
DECLARATION OF CONFORMITY
Aquadistri B.V
Vlietweg 8 4791 EZ, Klundert The Netherlands
Tel: +31 (0)168-408333
Fax: +31 (0)168-408334
Info@aquadistri.comn
www.aquadistri.com
Aquadistri B.V. is part of Aquatic Wholesale Group B.V.
Director R.J. van den Enden
Company registration mumber 23084659
VAT number NL8125.98.556.B.01
Technical specifications
- Pump: 220-240 V/50 Hz.
- RC-Receiver: 220-240 V/50 Hz.
- RC-Transmitter: DC 12 V, frequenty band: 433 MHz.
- Maximum Radiated Power <10 dBm = 10 mW.
Vlietweg 8, 4791 EZ Klundert, The Netherlands, info@aquadistri.com